Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Jun 26, 2011
Application Purpose
Original Equipment
Date of Application
Jun 26, 2011
Equipment Note
LOW POWER TRANSMITTER (2400-2483.5 MHz)
Frequency Range
2402.00000000 - 2480.00000000
Company
Garmin Canada Inc.
Country
Canada

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Parts List/Tune Up Info

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Note: information below must appear in User Documentation and/or Packaging. Dynastream Innovations Foot Pod 01715 Quick Reference Guide FCC Compliance Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. This device complies with part 15 of the FCC Rules. Operation is subject to the following two (2) conditions: (1) This device may not cause harmful interference and (2) this device must accept any interference received including interference that may cause undesired operation. CAUTION: Unauthorized changes or modification may void your authorization to operate this device under Part 15 Regulations. Industry Canada Compliance Category I radiocommunication devices comply with Industry Canada Standard RSS-210. Category II radiocommunication devices comply with Industry Canada Standard RSS-310. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Declaration of Conformity Hereby, Garmin (or BRAND NAME, if applicable) declares that this product is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. To view the full Declaration of Conformity, see the Garmin Web site for your product: www.garmin.com/declaration-of-conformity (or alternate). Markings Required: ANT+ Logo CE Logo FCC logo Russia GOST Logo with code Australia / New Zealand C-Tick logo with code N20233 Dynastream Technology logo WEEE Wheelie Bin Optional Information: Battery Information WARNING: Do not use a sharp object to remove user replaceable batteries. Contact your local waste disposal department to properly recycle the batteries. When the battery is low, a message appears on your receiver. Approximately five hours of foot pod battery life remain. Technical Specifications Physical size: L × W × H: 35 mm × 25 mm × 7.5 mm (excluding clip) Weight: 10 g (including battery) Water Resistance: 10 m Transmission range: Minimum 3 m (9.8 ft.) Battery: User-replaceable CR2032 (3 volts) Perchlorate Material – special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate. Battery life: 400 hours run time Operating temperature: From -10°C to 60°C (From 14°F to 140°F) Sensor Accuracy Range: From 0°C to 40°C (From 32°F to 104°F) Radio frequency/protocol: 2.4 GHz ANT ™ System Compatibility: ANT+™

Cover Letter(s)

June 24, 2011 Timco Engineering Inc. 849 NW State Road 45 Newberry, FL 32669 Applicant: Dynastream Innovations, Inc. #201, 100 Grand Blvd Cochrane, Alberta Canada T4C OS4 Re: Confidentiality for submittal information regarding FCC ID number O6R01715 PRODUCT: Low power Transmitters operated under part 15.249. Dear Sirs: Dynastream Innovations, Inc. requests that the material in the Schematics, Operational Description, block diagram, and parts list be withheld from public disclosure in accordance with Section 0.459 of the Commissions Rules, 47 C.F.R. 0.459, following grant of the application. In support of this request, Dynastream Innovations, Inc. submits the following: CONFIDENTIAL FILES Conf BlkDia 01715.pdf Conf OpDes 01715.pdf Conf Schem 01715.pdf 1. Identification of the specific information for which confidential treatment is sought: The materials set fourth in the Operational Description, block diagram, parts list, and Schematics, which are segregated, from the non-confidential exhibits of the application, are those for which confidentiality is sought. 2. Identification of the Commission proceeding in which the information was submitted or a description of the circumstances giving rise to the submission: The proceeding is that involving the application for equipment authorization (certification) under FCC ID No: O6R01715 3. Explanation of the degree to which the information is commercial or financial, or contains a trade secret or is privileged: This material includes a detailed theory of operation, circuit diagrams, and schematic. As such, this material is treated as highly confidential business information. ROGERS LABS, INC. 4405 West 259 th Terrace Louisburg, KS 66053 4. Explanation of the degree to which the information concerns a service that is subject to competition: The material for which confidentiality is sought is employed in the design and manufacture of this transmitting equipment that is offered on a highly competitive basis. Customers for this equipment have a variety of competing sources. 5. Explanation of how disclosure of the information could result in substantial competitive harm: Disclosure would, in effect, give away the fruits of the labors of Dynastream Innovations, Inc.’s engineering personnel, who have designed the equipment and the manufacturing process. Disclosure would also offer competitors additional unwarranted insight into the state of the product development, thereby allowing competitors an advantage, not available to Dynastream Innovations, Inc. 6. Identification of any measures taken by the submitting party to prevent unauthorized disclosure: The information for which confidential treatment is sought is kept confidential by Dynastream Innovations, Inc. and not made available to third parties except pursuant to non-disclosure agreements. 7. Identification of whether the information is available to the public and the extent of any previous disclosure of the information to third parties: To the knowledge of those preparing this application, the information has not been disclosed publicly heretofore. While the general theory of operation of this equipment has been the subject of numerous disclosures in industry and standards groups as well as in rule making proceedings of the FCC, the protection sought is narrowly drawn and pertains to certain specific implementations of this radio technology. 8. Justification of the period during which the submitting party asserts that the material should not be available for public disclosure: This material should not be disclosed for at least 25 years. While improvements in design are made relatively frequently, disclosure of the design information would lead to insights into both design and manufacturing techniques that could have an adverse competitive effect for many years to come. As such, it is important that the design not be made available to unauthorized persons who might attempt to use knowledge of the design to compromise the applications for which the equipment will be employed. Should you require any further information, please contact the undersigned. Thank you for your consideration in this matter. Sincerely, Scot Rogers

Cover Letter(s)

June 24, 2011 Timco Engineering Inc. Federal Communications Commission 849 NW State Road 45 Equipment Approval Services Newberry, FL 32669 P.O. Box 35815, Pittsburgh, PA 15251-3315 Applicant: Dynastream Innovations, Inc. Equipment: FCC ID: O6R01715 #201, 100 Grand Blvd CORES number: 0008-0335-57 Cochrane, Alberta FCC Rules: Parts 2 and 15.249 Canada T4C OS4 Men: The form 731 and application have been electronically submitted and any attachments will be up loaded to your web site to be used in obtaining a grant of certification. Confidentiality is requested as outlined below. Permanent Dynastream Innovations, Inc. requests that the material in the Parts List, Schematics, block diagram, and Operational Description be withheld from public disclosure in accordance with Section 0.459 of the Commissions Rules, 47 C.F.R. 0.459, following grant of the application. It is requested that the information contained in the operational description, block diagram, parts list, and schematics of the application be held confidential per Section 0.459. A statement of confidentiality will be attached with the application at the time of submittal. Schematics Conf Schem 01715.pdf Block diagram Conf BlkDia 01715.pdf Operational Description Conf OpDes SDM4A.pdf Should you require any further information, please contact the undersigned. Thank you for your consideration in this matter. Sincerely, Scot Rogers Rogers Labs, Inc. Enclosures ROGERS LABS, INC. 4405 West 259 th Terrace Louisburg, KS 66053 Phone / Fax (913) 837-3214

External Photos

Rogers Labs, Inc. Dynastream Innovations, Inc. FCC ID: O6R01715 4405 West 259 th Terrace Model: 01715 IC: 3797A-01715 Louisburg, KS 66053 Test #:110526 SN: 2624933 Phone/Fax: (913) 837-3214 Test to: CFR47 Parts 2, 15.249, RSS-210 Date: June 21, 2011 Revision 1 File: ExtPho 01715 Page 1 of 1 External photographs of equipment under test

ID Label/Location Info

Rogers Labs, Inc. Dynastream Innovations, Inc. FCC ID: O6R01715 4405 West 259 th Terrace Model: 01715 IC: 3797A-01715 Louisburg, KS 66053 Test #:110526 SN: 2624933 Phone/Fax: (913) 837-3214 Test to: CFR47 Parts 2, 15.249, RSS-210 Date: June 21, 2011 Revision 1 File: LabelSmp 01715 Page 1 of 1 FCC/IC ID label and location

Internal Photos

Rogers Labs, Inc. Dynastream Innovations, Inc. FCC ID: O6R01715 4405 West 259 th Terrace Model: 01715 IC: 3797A-01715 Louisburg, KS 66053 Test #:110526 SN: 2624933 Phone/Fax: (913) 837-3214 Test to: CFR47 Parts 2, 15.249, RSS-210 Date: June 24, 2011 Revision 1 File: IntPho 01715 Page 1 of 1 Internal Photographs PCB Front PCB Back

Parts List/Tune Up Info

Rogers Labs, Inc. Dynastream Innovations, Inc. FCC ID: O6R01715 4405 West 259 th Terrace Model: 01715 IC: 3797A-01715 Louisburg, KS 66053 Test #:110526 SN: 2624933 Phone/Fax: (913) 837-3214 Test to: CFR47 Parts 2, 15.249, RSS-210 Date: June 24, 2011 Revision 1 File: TunPro 01715 Page 1 of 1 Each units TX and RX functionality is tested and judged with a pass/fail criteria during production. Units meeting the criteria continue through production and others are returned for diagnostics.

RF Exposure Info

Rogers Labs, Inc. Dynastream Innovations, Inc. FCC ID: O6R01715 4405 West 259 th Terrace Model: 01715 IC: 3797A-01715 Louisburg, KS 66053 Test #:110526 SN: 2624933 Phone/Fax: (913) 837-3214 Test to: CFR47 Parts 2, 15.249, RSS-210 Date: June 22, 2011 Revision 1 File: RFExp 01715 Page 1 of 1 MPE Calculation page Dynastream Mo del: 01715Tes t Number:110526 MPE CalculatorMPE uses EIRP for calculation. EIRP is based on TX power added to the antenna gain in dBi. dBi = dB gain compared to an isotropic radiator. S = power density in mW/cm^2 Antenna Gain (dBi)1 Output PowerdBd + 2.17 = dBidBi to dBd2.2 Tx Freq uency (MHz)2457Maximum (W atts )0.000559A n ten na Gain (dBd)-1.17 Cable Loss (dB)0.0(dBm)-2.53Antenna minus cable (dBi)1.00 Calcu lat ed ERP (mw) 0.427EIRP = Po (d BM ) + Gain (d B) Calcu lated EIRP (mw) 0.703Rad iated (EIRP) d Bm-1.529 ERP = EIRP - 2.17 d B Occupational Limit Radiated (ERP) dBm-3.699 5.00000 mW /cm 2 50.00000 W /m 2 General Public Limit 1.00000 mW /cm 2 10.00000 W /m 2 Frequency (MHz)Occupational LimitPublic Limit 300-1,500f/300f/1500 1,500-10,00051 Frequency (MHz) Occupational Limit @ Tx Freq Public Limit @ Tx Freq 300-1,500 (mW /cm2)8.191.638 300-1,500 (W /m2)81.916.38 1,500-10,000 (mW /cm2)51 1,500-10,000 (W /m2)5010 EIRPSSDistanceDistanceDistanceDistance milliwat tsmW /cm 2 W/m 2 cmmeterinchesFeet 0.7030.000560.0056010.000.103.940.01 0.7030.000690.006919.000.093.540.01 0.7030.000870.008748.000.083.150.01 0.7030.001140.011427.000.072.760.01 0.7030.001550.015556.000.062.360.01 0.7030.002240.022395.000.051.970.00 0.7030.003500.034984.000.041.570.00 0.7030.006220.062183.000.031.180.00 0.7030.013990.139912.000.020.790.00 0.7030.055960.559641.000.010.390.00 0.7030.069090.690920.900.0090.350.001 0.7030.087440.874440.800.0080.310.001 0.7030.114211.142130.700.0070.280.001 0.7030.155461.554570.600.0060.240.001 0.7030.223862.238570.500.0050.200.000 0.7030.349783.497770.400.0040.160.000 0.7030.621836.218260.300.0030.120.000 Frequency (MHz) Occupational Limit min imu m Dis t a n c e (meters) Occupational Limit min imu m Dis t a n c e (cm / inches) Pu b lic Limit min imu m distance (meters) Pu b lic Limit min imu m distance (cm / inches) 300-1,500N/AN/AN/AN/A 1,500-10,000N/AN/AN/AN/A FCC radio frequ en cy radiatio n exp os ure limits per 1.1310 FCC radio frequ en cy radiatio n exp os ure limits per 1.1310 Power density (S) EIRP -------= m W/cm ^2 4 pr^2 r (cm ) EIRP (m W)

Test Report

NVLAP Lab Code 200087-0 Rogers Labs, Inc. Dynastream Innovations, Inc. 4405 West 259 th Terrace Model: 01715 FCC ID: O6R01715 Louisburg, KS 66053 Test #:110526 SN: 2624933 IC: 3797A-01715 Phone/Fax: (913) 837-3214 Test to: FCC Parts 2 and 15.249, RSS-210 Date: June 21, 2011 Revision 1 File: Dynastream 01715 TstRpt 110526 Page 1 of 33 Application Submittal Report For FCC And Industry Canada Grant Of Certification FOR Model: 01715 2402 - 2480 MHz Transmitter FCC ID: O6R01715 IC: 3797A-01715 FOR Dynastream Innovations, Inc. #201, 100 Grand Blvd. Cochrane, Alberta T4C 0S4, Canada Test Report Number: 110526 Authorized Signatory: Scot D. Rogers NVLAP Lab Code 200087-0 Rogers Labs, Inc. Dynastream Innovations, Inc. 4405 West 259 th Terrace Model: 01715 FCC ID: O6R01715 Louisburg, KS 66053 Test #:110526 SN: 2624933 IC: 3797A-01715 Phone/Fax: (913) 837-3214 Test to: FCC Parts 2 and 15.249, RSS-210 Date: June 21, 2011 Revision 1 File: Dynastream 01715 TstRpt 110526 Page 2 of 33 Engineering Test Report For Grant Of Certification Application Submittal CFR47, Part 15C - Intentional Radiators Paragraph 15.249, Industry Canada, RSS-210 Low Power Transmitter For Dynastream Innovations, Inc. #201, 100 Grand Blvd. Cochrane, Alberta T4C 0S4, Canada Phone: (913) 397-8200 Mr. Jim Rooney President Model: 01715 Frequency 2402 - 2480 MHz FCC ID#: O6R01715 IC: 3797A-01715 Test Date: May 26, 2011 Certifying Engineer: Scot D. Rogers Rogers Labs, Inc. 4405 West 259 th Terrace Louisburg, KS 66053 Telephone: (913) 837-3214 This report shall not be reproduced except in full, without the written approval of the laboratory. This report must not be used by the client to claim product endorsement by NVLAP, NIST, or any agency of the U.S. Government. ROGERS LABS, INC. 4405 West 259 th Terrace Louisburg, KS 66053 Phone / Fax (913) 837-3214 NVLAP Lab Code 200087-0 Rogers Labs, Inc. Dynastream Innovations, Inc. 4405 West 259 th Terrace Model: 01715 FCC ID: O6R01715 Louisburg, KS 66053 Test #:110526 SN: 2624933 IC: 3797A-01715 Phone/Fax: (913) 837-3214 Test to: FCC Parts 2 and 15.249, RSS-210 Date: June 21, 2011 Revision 1 File: Dynastream 01715 TstRpt 110526 Page 3 of 33 Table of Contents TABLE OF CONTENTS .................................................................................................. 3 FORWARD ..................................................................................................................... 5 APPLICABLE STANDARDS & PROCEDURES ............................................................ 5 OPINION / INTERPRETATION OF RESULTS ............................................................... 5 APPLICATION FOR CERTIFICATION ........................................................................... 6 STATEMENT OF MODIFICATIONS AND DEVIATIONS ............................................... 6 EQUIPMENT TESTED .................................................................................................... 7 EQUIPMENT FUNCTION AND TESTING PROCEDURES ............................................ 7 Test Setup .............................................................................................................................................................. 7 EQUIPMENT CONFIGURATIONS FOR 01715 .............................................................. 7 AC Line Conducted Emission Test Procedure .................................................................................................. 8 Radiated Emission Test Procedure ..................................................................................................................... 8 ENVIRONMENTAL CONDITIONS.................................................................................. 8 UNITS OF MEASUREMENTS ........................................................................................ 8 TEST SITE LOCATIONS ................................................................................................ 9 LIST OF TEST EQUIPMENT .......................................................................................... 9 GENERAL EMISSIONS (UNINTENTIONAL RADIATORS) ......................................... 10 AC Line Conducted EMI Procedure ................................................................................................................ 10 Summary of Results for AC Line Conducted Emissions ................................................................................ 10 Radiated EMI ..................................................................................................................................................... 10 Figure One Plot of General Radiated Emissions ............................................................................................... 11 Figure Two Plot of General Radiated Emissions ............................................................................................... 11 Figure Three Plot of General Radiated Emissions ............................................................................................. 12 Figure Four Plot of General Radiated Emissions .............................................................................................. 12 Figure Five Plot of General Radiated Emissions ............................................................................................... 13 Figure Six Plot of General Radiated Emissions ................................................................................................. 13 Figure Seven Plot of General Radiated Emissions ............................................................................................ 14 General Radiated Emissions Data from EUT .................................................................................................. 14 Summary of Results for Radiated Emissions ................................................................................................... 14 INTENTIONAL RADIATORS EMISSIONS ........................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Rogers Labs, Inc. Dynastream Innovations, Inc. FCC ID: O6R01715 4405 West 259 th Terrace Model: 01715 IC: 3797A-01715 Louisburg, KS 66053 Test #:110526 SN: 2624933 Phone/Fax: (913) 837-3214 Test to: CFR47 Parts 2, 15.249, RSS-210 Date: June 21, 2011 Revision 1 File: TSup 01715 Page 1 of 1 Test setup photographs

Contact Information

Applicant

Jim Rooney(President)
[email protected](403)932-9292Fax: (403)932-6521

Test Firm

Rogers Labs, Inc.Scot Rogers
[email protected]913-837-3214Fax: 913-837-3214

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz-
Confidentiality
Long Term

Other Applications from Garmin Canada Inc.

N5 - FCC ID O6R2398 - Garmin Canada Inc.
O6R2398

N5

Mar 04, 2014

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
LOW POWER TRANSMITTER (2400-2483.5) - FCC ID O6R02162 - Garmin Canada Inc.
O6R02162

LOW POWER TRANSMITTER (2400-2483.5)

Jun 19, 2013

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
LOW POWER TRANSMITTER (2400-2483.5 MHz) - FCC ID O6R2021 - Garmin Canada Inc.
O6R2021

LOW POWER TRANSMITTER (2400-2483.5 MHz)

Jan 08, 2013

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
LOW POWER TRANSMITTER (2400-2483.5 MHz) - FCC ID O6R1823 - Garmin Canada Inc.
O6R1823

LOW POWER TRANSMITTER (2400-2483.5 MHz)

Sep 20, 2011

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
USB2 - FCC ID O6RUSB2 - Garmin Canada Inc.
O6RUSB2

USB2

May 10, 2010

Equipment Class