FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Hi-G-Tek Ltd/
  3. OB6-IGMA125IS

OB6-IGMA125ISIS Micro Reader

Hi-G-Tek Ltd
IS Micro Reader - FCC ID OB6-IGMA125IS - Hi-G-Tek Ltd
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Feb 26, 2008
Application Purpose
Original Equipment
Date of Application
Feb 25, 2008
Equipment Note
IS Micro Reader
Frequency Range
0.12500000 - 0.12500000
Company
Hi-G-Tek Ltd
Country
Israel

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Operational Description

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Hi-G-Tek I.S Micro-Reader User Manual UM47xx Date: 12, Oct. 2007 Rev: 1.0 1. Introduction The Hi-G-Tek I.S Micro Reader is a component of Hi-G-Tek’s wireless monitoring system designed to withstand hazardous locations such as fuel-atmosphere interactions and other harsh outdoor applications. The Micro Reader is an ergonomic handheld sized RFID reader (Radio Frequency Identification) used for short-range wireless communication (up to 10cm) The Micro Reader communicates over the low-frequency channel (125 KHz) with the Hi-G- Tek's RFID sensors (electronic lock/seal/ tag that provides automatic processing and real- time monitoring of secured cargoes/assets in transit and in storage) It contains two command buttons and two-colored LED as well as a beeper for status indication. 2. Safety Precautions The only maintenance required, is to replace the battery when necessary. To replace the battery, open the battery compartment using medium size screwdriver Take out the old battery and put a new one (Note polarity) NOTE: Use 3V Lithium type CR2032 battery only. Close properly cover after installing the fresh bat ATTENTION • Hi-G-Tek's IS Micro Reader is distributed to a commercial/industrial use only, and should only be handled by personnel authorized by Hi-G-Tek representatives. • Installation must be performed according to this User Guide. • Using only certified antennas: It is the responsibility of the installer to ensure that when using the outdoor antenna kits in the United States (or where FCC rules apply), only those antennas certified with the product are used. • The use of any antenna other than those certified with the product is expressly forbidden in accordance with FCC rules CFR47 part 15.204 and part 15.203. The FCC Wants You to Know This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: a) Reorient or relocate the receiving antenna. b) Increase the separation between the equipment and receiver. c) Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. d) Consult the dealer or an experienced radio/TV technician. FCC Warning Modifications not expressly approved by the manufacturer could void the user authority to operate the equipment under FCC Rules. Instructions concerning human exposure to radio frequency electromagnetic fields: A distance of at least 20cm. between the equipment and all persons should be maintained during the operation of the equipment. 3. Using the Micro Reader The Micro Reader performs two basic functions (depending on the application): 1) It verifies the lock/seal/tag status and provides the user with an indication as to whether the device has been tampered with since being set. 2) It can also reset the lock/seal/tag for a new use. It also leaves a “footprint” in the lock/seal/tag memory with the Micro Reader’s ID, identifying the specific Micro Reader that performed a command or interrogation. 3.1 Read Command • Approach the Data Seal / Tag as to a distance of 3-8cm and press the R button. o In the event that the seal status is OK, Green LED will turn on and a corresponding “beep” will sound o In the event that the seal status has changed (opened or tampered) the Red LED will turn on and a corresponding “beep” will sound. NOTE: In the event that the communication between the Micro Reader and the Data Seal/Tag failed, the Micro Reader will pause for two seconds and the Red LED will flash three times with corresponding three fast “beeps”. Make sure to keep a distance up to 8cm! Blinking Red: Comm. Fail Continuous Red: (1) After READ: Seal /Tag has tampered or opened. (2) After SET: SET failed. READ Command Button SET Command Button Continuous Green: (1) After READ: OK Status - Seal /Tag remained secured. (2) After SET: SET confirmed 3.2 SET Command • Approach the Data Seal / Tag as to a distance of 3-8cm and press the S button. o In the event that the seal / Tag is properly secured, Green LED will turn on and a corresponding “beep” will sound indicating the SET command has been succeeded. NOTE: In the event that the SET command failed, the Micro Reader will pause for two seconds and the Red LED will turn on with a corresponding beep sound, make sure that the seal /tag is properly closed and locked. SET modes Depending on the application, you can choose* to perform either "soft set" or normal set: • “SOFT SET”: Setting the seal without erasing the events logged in seal’s memory. • "SET": Setting the seal and erasing the events logged in seal’s memory (refreshed start) * This feature can be programmed in advance before use. For detailed information please contact Hi-G-Tek's applications tech. support. 4. Technical spec. RF Characteristics LF Tx/Rx Channel 125KHz Modulation Amplitude Modulation (OOK) Range Up to 10cm Data rate 4KHz data rate Power Power supply type: 3V Replaceable battery powered Physical Characteristics Dimensions 90x40x25mm Weight 150gr Environmental Operating Temperature -10°C to +50°C Storage Temperature -20°C to +60°C Protection Class IP 54 (with product's pouch)

Block Diagram

IS Micro Reader, model: IGMA125IS 2. Block Diagram – IS Micro Reader Y1 8MHz LF Ant.125KHz μ P Rx Tx KEYPAD LED 1 LED 2 BUZZER 3V Lithium BAT. UL Recognized File no. mh14002

Cover Letter(s)

Feb 16, 2008 Attn: Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: OB6-IGMA125IS Dear Sir or Ma'am, Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: • Conf IG-MA-IS125 Assembly Schem.pdf • Conf IG-MA-IS125 PartsLst.pdf • Conf IG-MA-IS125 Schem.pdf The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Hi-G-Tek Ltd. understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application.

Cover Letter(s)

February 14, 2008 Attn: Timco Engineering Inc. To Whom It May Concern, Letter of Authorization We hereby authorize Shaike Raz of ITL to act on the behalf of Hi-G-Tek Ltd, regarding the FCC ID Certification process for the following application: IS Micro Reader, Model IG-MA-31, FCC ID: OB6-IGMA125IS

External Photos

Bottom of Unit Top of Unit

ID Label/Location Info

Product Labeling for IG-MA-125IS

ID Label/Location Info

7. Product Labeling for IG-MA-125IS Figure 1 : Example of Product label with FCC ID

Internal Photos

Internal circuit board bottom Internal circuit board Top Internal Circuit board Top Bottom Plastic cover Bottom

Operational Description

IS Micro Reader, model: IGMA125IS Hi-G-Tek's FRN Number: 0006699334 Handheld Data Terminal: IG-MA-31, FCC ID Number: OB6-IGMA125IS Sections for Technical Compliance Report 1. General description The Hi-G-Tek I.S Micro Reader is a component of Hi-G-Tek’s wireless monitoring system designed to withstand hazardous locations such as fuel-atmosphere interactions and other harsh outdoor applications. The Micro Reader is an ergonomic handheld sized RFID reader (Radio Frequency Identification) used for short-range wireless communication (up to 10cm) The Micro Reader communicates over the low-frequency channel (125 KHz) with the Hi-G-Tek's RFID sensors (electronic lock/seal/ tag that provides automatic processing and real-time monitoring of secured cargoes/assets in transit and in storage) It contains two command buttons used for two basic LF interrogation commands and two-colored LED as well as a beeper for status indication. The Micro Reader performs two basic functions: 1) It verifies the lock/seal/tag status and provides the user with an indication as to whether the device has been tampered with since being set. 2) It can also reset the lock/seal/tag for a new use. It also leaves a “footprint” in the lock/seal/tag memory with the Micro Reader’s ID, identifying the specific Micro Reader that performed a command or interrogation. Description μP : The μP(U1) is a Texas Instruments ultralow-power microcontroller (MSP430 family) with a 8MHz clock (piezoelectric ceramic resonator) is the heart of the Micro Reader, it generates the 125KHz carrier wave for the LF transceiver, synchronizes and manages the short range data communication. LF Transceiver : This analog transmitter/receiver utilized for short range communication on-off keying modulation (OOK) based on 125KHz carrier wave with 4KHz data rate. The Tx interface modulates the data from the μP together with the 125Khz carrier wave, the modulated signal is transmitted through a SMT ferrite rod LF antenna .The Rx interface receive the data from the ferrite antenna, detect it and transfer it to the μP. Buzzer: Standard piezo buzzer for audible notifications and alarms. Keypad: Lexan keypad with two push buttons. Antenna: Surface mount (SMD) ferrite 1.8mH inductor Power: 3V replaceable Lithium battery (button cell) with rated capacity of 235mAH Resonator(Y1) : 8MHz Piezoelectric ceramic resonator (manufactured by Murata) used for time base oscillator of the microcontroller. 3. Technical spec. RF Characteristics LF Tx/Rx Channel 125KHz Modulation Amplitude Modulation (OOK) Range Up to 10cm Data rate 4KHz data rate Power Power supply type: 3V Replaceable battery powered Physical Characteristics Dimensions 90x40x25mm Weight 150gr Environmental Operating Temperature -10°C to +50°C Storage Temperature -20°C to +60°C Protection Class IP 54 3. System Test Configuration Justification To be determine with the test engineer (Ella Pitt) 4. EUT Exercise Software Normally, the EUT transmits short messages in short periods. Therefore, in order to enable measurements of the transmitted signals, the EUT exercise program used during the RF testing was designed to transmit continuously random data or carrier wave (cw) according to test procedures. 5. Special Accessories No special accessories were needed to achieved compliance 6. Equipment Modifications Section No special modification of EUT were needed to achieved compliance

Test Report

Cert. No. 1152.01 Electrical (EMC) Test Report E76251.01 Hi-G-Tek Ltd. Page 1 of 32 DATE: 24 February 2008 I.T.L. (PRODUCT TESTING) LTD. FCC EMC/Radio Test Report for Hi-G-Tek Ltd. Equipment under test: IS Micro Reader IG-MA-125IS Written by: _____________________________ D. Shidlowsky, Documentation Approved by: _____________________________ E. Pitt, Test Engineer Approved by: _____________________________ I. Raz, EMC Laboratory Manager This report must not be reproduced, except in full, without the written permission of I.T.L. (Product Testing) Ltd. This report relates only to items tested. ITL FCCMASVE 1.25 26 March 2003 Cert. No. 1152.01 Electrical (EMC) Test Report E76251.01 Hi-G-Tek Ltd. Page 2 of 32 Measurement/Technical Report for Hi-G-Tek Ltd. Equipment under test: IS Micro Reader FCC ID: OB6-IGMA125IS DATE: 24 February 2008 This report concerns: Original Grant x Class II change ___ Class B verification Class A verification Class I change ____ Equipment type: Low Power Transmitter Below 1705 kHz Request Issue of Grant: x Immediately upon completion of review Limits used: CISPR 22 Part 15 x Measurement procedure used is ANSI C63.4-2003. Application for Certification Applicant for this device: prepared by: (different from "prepared by") Ishaiahou Raz Yossi Hershko ITL (Product Testing) Ltd. Hi-G-Tek Ltd. Kfar Bin Nun 16 Hacharoshet St. D.N. Shimshon 99780 Or Yehuda 60375 Israel Israel Tel: +972-8-979-7010 Tel: +972-3-533-9359 Fax: +972-8-979-7702 Fax: +972-3-533-8225 Email: [email protected] Email: [email protected] ITL FCCMASVE 1.25 26 March 2003 TABLE OF CONTENTS 1. GENERAL INFORMATION -------------------------------------------------------------------------------4 1.1 Administrative Information.................................................................................4 1.2 List of Accreditations.........................................................................................5 1.3 Product Description...........................................................................................6 1.4 Test Methodology..............................................................................................6 1.5 Test Facility.......................................................................................................7 1.6 Measurement Uncertainty.................................................................................7 2. PRODUCT LABELING-------------------------------------------------------------------------------------8 3. SYSTEM TEST CONFIGURATION---------------------------------------------------------------------9 3.1 Justification........................................................................................................9 3.2 EUT Exercise Software.....................................................................................9 3.3 Special Accessories..........................................................................................9 3.4 Equipment Modifications...................................................................................9 3.5 Configuration of Tested System........................................................................9 4. BLOCK DIAGRAM-----------------------------------------------------------------------------------------10 4.1 Schematic Block/Connection Diagram............................................................10 4.2 Theory of Operation ........................................................................................11 5. FIELD STRENGTH OF FUNDAMENTAL ------------------------------------------------------------12 5.1 Test Specification............................................................................................12 5.2 Test Procedure................................................................................................12 5.3 Measured Data................................................................................................12 5.4 Test Instrumentation Used, Field Strength of Fundamental ...........................14 6. RADIATED MEASUREMENT PHOTO ---------------------------------------------------------------15 7. SPURIOUS RADIATED EMISSION 9KHZ-30 MHZ -----------------------------------------------16 7.1 Measured Data................................................................................................16 7.2 Test Instrumentation Used, Radiated Measurements.....................................17 7.3 Field Strength Calculation...............................................................................18 8. RADIATED EMISSION TEST DATA PER FCC PART 15, SUB-PART B-------------------19 8.1 Test Specification............................................................................................19 8.2 Test Procedure................................................................................................19 8.3 Test Data.........................................................................................................20 8.4 Test Instrumentation Used, Radiated Measurements.....................................25 9. PHOTOGRAPHS OF TESTED E.U.T.----------------------------------------------------------------26 10. APPENDIX A - CORRECTION FACTORS ----------------------------------------------------------29 10.1 Correction factors for CABLE.........................................................................29 12.6 Correction factors for LOG PERIODIC ANTENNA........................................30 10.2 Correction factors for BICONICAL ANTENNA...............................................31 10.3 Correction factors for ACTIVE LOOP ANTENNA...........................................32 Test Report E76251.00 Hi-G-Tek Ltd. Page 3 of 32 ITL FCCMASVE 1.25 26 March 2003 1. General Information 1.1 Administrative Information Manufacturer: Hi-G-Tek Ltd. Manufacturer's Address: 16 Hacharoshet St. Or-Yehuda 60375 Israel Tel: +972-3-533-9359 Fax: +972-3-533-9225 Manufacturer's Representative: Yossi Hershko Arkady Genin Equipment Under Test (E…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Roni Cohen(Hardware Department Manager)
[email protected]+972-3533-9359Fax: +972-3533-9225

Test Firm

Israel Testing LaboratoriesIIan Cohen
[email protected]972-3-5339022Fax: 972-3-5339019

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.125 MHz - 0.125 MHz-
Confidentiality
Long Term

Other Applications from Hi-G-Tek Ltd

SPDS SEAL - FCC ID OB6-IGSV40916 - Hi-G-Tek Ltd
OB6-IGSV40916

SPDS SEAL

Dec 25, 2013

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
ISO 18000-7 SENSOR TRANSPONDER - FCC ID OB6-IGST51433 - Hi-G-Tek Ltd
OB6-IGST51433

ISO 18000-7 SENSOR TRANSPONDER

Jan 18, 2010

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
ISO 18000-7 SECURITY TRANSPONDER - FCC ID OB6-IGST50433 - Hi-G-Tek Ltd
OB6-IGST50433

ISO 18000-7 SECURITY TRANSPONDER

Jan 18, 2010

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
ISO-18000- FIXED RFID INTERROGATOR - FCC ID OB6-IGRF97433 - Hi-G-Tek Ltd
OB6-IGRF97433

ISO-18000- FIXED RFID INTERROGATOR

Jan 03, 2010

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
COMPACT READER AND POWER SUPLY AND COMMUNICATION - FCC ID OB6-IGCR46D916 - Hi-G-Tek Ltd
OB6-IGCR46D916

COMPACT READER AND POWER SUPLY AND COMMUNICATION

Jul 17, 2007

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter