Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
i-PORT MB Manual Version 1.1 IDENTECSOLUTIONSAG MillenniumPark2 6890Lustenau Austria Tel.:+43557787387'0 Fax:+43557787387'15 [email protected] www.identecsolutions.com i'PORTMB–Manual Version1.102.02.2007Page2/ 37 Proprietary Notice ThisdocumentcontainsconfidentialinformationproprietarytoIDENTECSOLUTIONSandmaynotbeusedor disclosedtootherpartiesinwholeorinpartwithoutpriorwrittenauthorizationfromIDENTECSOLUTIONS. Disclaimer and Limitation of Liability IDENTECSOLUTIONSAGanditsaffiliates,subsidiaries,officers,directors,employeesandagentsprovidethe informationcontainedinthisManualonan“as'is”basisanddonotmakeanyexpressorimpliedwarrantiesor representationswithrespecttosuchinformationincluding,withoutlimitation,warrantiesastonon'infringement, reliability,fitnessforaparticularpurpose,usefulness,completeness,accuracyorup'to'dateness.IDENTEC SOLUTIONSshallnotinanycircumstancesbeliabletoanypersonforanyspecial,incidental,indirector consequentialdamages,includingwithoutlimitation,damagesresultingfromuseoforrelianceoninformation presentedherein,orlossofprofitsorrevenuesorcostsofreplacementgoods,evenifinformedinadvanceofthe possibilityofsuchdamages. Trademarks “IDENTECSOLUTIONS”,“IntelligentLongRange”,“ILR”andthestylized“i”areregisteredtrademarksand“i'Q”, “i'D”,“i'B”,“i'CARD”,“i'PORT”,“i'LINKS”,“Solutions.It’sinourname.”,“Smartenupyourassets”aretrademarks ofIDENTECSOLUTIONS,Inc.and/orIDENTECSOLUTIONSAG. Copyright Notice Copyright © 2006IDENTECSOLUTIONS.Allrightsreserved. Nopartofthisdocumentmaybereproducedortransmittedinanyformbyanymeans,photographic,electronic, mechanicalorotherwise,orusedinanyinformationstorageandretrievalsystem,withoutthepriorwritten permissionofIDENTECSOLUTIONS. i'PORTMB–Manual Version1.102.02.2007Page3/37 RadioFrequencyComplianceStatement IDENTECSOLUTIONSistheresponsiblepartyforthecomplianceofthefollowingdevices: MODEL: i'PORTMB i'CARDCF i'BTags EUROPE: CE CE CE Theuser(s)oftheseproductsarecautionedtoonlyuseaccessoriesandperipheralsapproved,inadvance,by IDENTECSOLUTIONS.Theuseofaccessoriesandperipherals,otherthanthoseapprovedbyIDENTEC SOLUTIONS,orunauthorizedchangestoapprovedproducts,mayvoidthecomplianceoftheseproductsandmay resultinthelossoftheuser(s)authoritytooperatetheequipment. Operationissubjecttothefollowingconditions:(1)thesedevicesmaynotcauseharmfulinterference,and(2) thesedevicesmustacceptanyinterference,includinginterferencethatmaycauseundesiredoperationofthe device. EuropeanNotificationaccordingR&TTEDirective(i'CARD3/EU) ThisequipmentcompliestoArt.6.4ofR&TTEDirective(1999/5/EC).Itistestedforcompliancewiththe followingstandards: EN300220'1V1.3.1(2000'09),EN300220'3V1.3.1(2000'09),ETSIEN301489V1.4.1(2002'08),ETSIEN 301489V1.4.1(2002'08) USANotification Thisdevicecomplieswithpart15oftheFCCRules.Operationissubjecttothefollowingtwoconditions:(1) Thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemustacceptanyinterferencereceived, includinginterferencethatmaycauseundesiredoperation. i'PORTMB–Manual Version1.102.02.2007Page4/ 37 Table of Contents 1 INTRODUCTION..........................................................................................................................5 1.1 FUNDAMENTALS............................................................................................................................ 5 1.2 SYSTEMOVERVIEW....................................................................................................................... 5 2.0 COMPONENTS .............................................................................................................................7 2.1 I'PORTMB ................................................................................................................................ 7 2.2 ANTENNAS.................................................................................................................................. 7 2.3. I'BTAG..................................................................................................................................... 9 3.0 INSTALLATION AND SET-UP.................................................................................................... 10 3.1 MOUNTINGTHEI'PORTMB ......................................................................................................... 12 3.2 INTERFACESANDLEDDISPLAYS..................................................................................................... 15 4.0 COMMUNICATION PROTOCOL................................................................................................. 17 4.1 TELEGRAMSTRUCTURE,ESCAPINGANDCRC ..................................................................................... 17 4.2 GETVERSIONCOMMAND............................................................................................................... 19 4.3 GETTAGSCOMMAND................................................................................................................... 20 4.4 GETTAGEXTENDEDCOMMAND....................................................................................................... 22 4.5 GETTAGFULLCOMMAND.............................................................................................................. 24 4.6 SETPARAMETERCOMMAND............................................................................................................ 26 4.7 GETPARA…
Text truncated - open the document above for the full version.
i-PORT Mx Professional Installation Declaration IDENTEC SOLUTIONS AG; Millennium Park 2; 6890 Lustenau; Austria Page 1 of 1 The objective of this document is to explain why an installation of the equipment needs to be carried out by professional personal only 1) Marketing Due to the complexity of the RFID technology the equipment is not an of the shelf product as it is a part of a solution and therefore is not possible to sell it in retail. 2) Requires Professional Installation - The installation will be controlled - The installation will be carried out by specially trained personal to ensure the functionality - The RF environment will be evaluated before installing the equipment in order to reach best performance. - Due to the connection to PC systems a Software programming/Installation is required. 3) Application The intended use of the RFID equipment is in mainly to optimise Logistic/ production processes but can also be used in unnamed other applications. However, it is generally for industrial/commercial use.
Ersteller: U. Rodemeier Revision: 03 Erstelldatum: 03.08.01 Datum: 4.10.2006 Seite 1 von 1 Request for Confidentiality PHOENIX TESTLAB GmbH Date: 19 March 2007 Product Certification Königswinkel 10 D 32825 Blomberg RE: Certification Application FCC ID: 004-ILR-IPM Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the Commission’s Rule, the applicant hereby requests confidential treatment of information accompanying this application as outlined below: • Schematics • Block Diagram • Technical Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to rule 0.457, disclosure od this application and all accompanying documentation will not be made before the date of the GRANT for this application ́. Thank you for your attention in this matter. Applicant’s Company : Senton GmbH address : Auessere Fruehlingstrasse 45, D-94315 Straubing Signature : Johann Roidt Job Title and Dept. : Technical Director
FCC ID OO4-ILR-IPM FCC ID OO4-ILR-IPM FCC ID OO4-ILR-IPM FCC ID OO4-ILR-IPM FCC ID OO4-ILR-IPM
FCC ID OO4-ILR-IPM FCC ID OO4-ILR-IPM FCC ID OO4-ILR-IPM FCC ID OO4-ILR-IPM FCC ID OO4-ILR-IPM
Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 55456-060996-2 (Edition 2) Page 1 of 49 Page(s) Straubing, 26 March 2007 T E S T - R E P O R T No. 55456-060996-2 (Edition 2) for i-Port M Tag Reader for Active Tags Applicant: IDENTEC SOLUTIONS AG Test Specifications: FCC Code of Federal Regulations, CFR 47, Part 15, Sections 15.107, 15.109, 15.111(a), 15.205, 15.207, 15.215 and 15.249 Industry Canada Radio Standards Specifications RSS-Gen Issue 1, Sections 7.2.2, 7.2.3 and RSS-210 Issue 6, Sections 2.2, A2.9 (Category I Equipment) Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 55456-060996-2 (Edition 2) Page 2 of 49 Page(s) Table of Contents 1 Description of the Equipment Under Test (EUT) ........................................................ 3 2 Administrative Data..................................................................................................... 4 3 Identification of the Test Laboratory ........................................................................... 5 4 Summary .................................................................................................................... 6 5 Operation Mode and Configuration of EUT ................................................................ 7 6 Measurement Procedures .......................................................................................... 8 6.1 Conducted Output Power ..................................................................................... 8 6.2 Bandwidth Measurements .................................................................................. 10 6.3 Conducted AC Powerline Emission.................................................................... 12 6.4 Radiated Emission in Fully or Semi Anechoic Room ......................................... 14 6.5 Radiated Emission at Open Field Test Site........................................................ 16 6.6 Antenna Power Conduction Emission of Receivers ........................................... 18 7 Photographs Taken During Testing .......................................................................... 20 8 Test Results for Transmitter ..................................................................................... 25 8.1 Conducted Output Power ................................................................................... 27 8.2 Occupied Bandwidth .......................................................................................... 28 8.3 Bandwidth of the Emission ................................................................................. 32 8.4 Designation of Emissions ................................................................................... 34 8.5 Restricted Bands of Operation ........................................................................... 35 8.6 Conducted Powerline Emission Measurement 150 kHz to 30 MHz .................. 37 8.7 Radiated Emission Measurement 30 MHz to 25 GHz ....................................... 39 8.8 Exposure of Humans to RF Fields...................................................................... 41 9 Test Results for Receiver ......................................................................................... 43 9.1 Radiated Emission Measurement 30 MHz to 5 GHz ......................................... 44 9.2 Antenna Power Conduction Emission of Receivers 9 kHz to 5 GHz ................. 45 10 Referenced Regulations ........................................................................................... 47 11 Charts taken during testing ....................................................................................... 49 Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 55456-060996-2 (Edition 2) Page 3 of 49 Page(s) 1 Description of the Equipment Under Test (EUT) General data of EUT Type designation 1 : i-Port M Parts 2 : Serial number(s): 096471M0043 Manufacturer: IDENTEC SOLUTIONS AG Type of equipment: Tag Reader for Active Tags Version: As delivered (with conductive lacquer) FCC ID: Additional parts/accessories: Technical data of EUT Application frequency range: 902 MHz - 928 MHz Frequency range: 916 MHz Operating frequency: 916 MHz Type of modulation: ASK Pulse train: Pulse width: Number of RF-channels: 1 Channel spacing: Not applicable Designation of emissions 3 : 184kA1D Type of antenna: Rod antenna RADIAL/LARSEN, Model: SPDA24832 Dipole Size/length of antenna: 20 cm Connection of antenna: detachable not detachable Type of power supply: DC supply Specifications for power supply: nominal voltage: 12.0 V 1 Type designation of the system if EUT consists of more than one part. 2 Type designations of the parts of the system, if applicable. 3 Also known as "Class of Emission". Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 55456-060996-2 (Edition 2) Page 4 of 49 Page(s) 2 Administrative Data Application details Applicant (full address): IDENTEC SOLUTIONS AG Millenniumspark 2 A-6890 Lustenau Contact person: Mr. Josef Vogel Contract identification: Order no. 46600490 Receipt of EUT: 15 December 2006 Date(s) of test: January 2007 Note(s): Report details Report number: 55456-060996-2 Edition: 2 Issue date: 26 March 2007 Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 55456-060996-2 (Edition 2) Page 5 of 49 Page(s) 3 Identification of the Test Laboratory Details of the Test Laboratory Company name: Senton GmbH EMI/EMC Test Center Address: Aeussere Fruehlingstrasse 45 D-94315 Straubing Germany Laboratory accreditation: DAR-Registration No. DAT-P-171/94-02 FCC test site registration number 90926 Industry Canada test site registration: IC 3050 Contact person: Mr. Johann Roidt Phone: (+49) (0)9421 5522-0 Fax: (+49) (0)9421 5522-99 Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 55456-060996-2 (Edition 2) Page 6 of 49 Page(s) 4 Summary Summary of test results The tested sample complies with t…
Text truncated - open the document above for the full version.
Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 55456-060996-2 (Edition 1) Page 20 of 47 Pages Test setup for conducted AC powerline emission measurement Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 55456-060996-2 (Edition 1) Page 21 of 47 Pages Test setup for radiated emission measurement (fully anechoic room) Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 55456-060996-2 (Edition 1) Page 22 of 47 Pages Test setup for radiated emission measurement (open field test site) Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 55456-060996-2 (Edition 1) Page 23 of 47 Pages Test setup for radiated emission measurement (open field test site) - continued -
Aeussere Fruehlingstrasse 45 · Straubing · Germany
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 916.5 MHz - 916.5 MHz | - |

iMARK EC and iMARK IC
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
iQ350 RNB tag
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
iPOINT Si UHF / NFC / LF reader
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
iPoint X (ATEX) UHF / NFC / LF reader
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
iQ355 (X)P Personal Tag
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter