FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Identec Solutions AG/
  3. OO4-ILR-IPM350N

OO4-ILR-IPM350NRFID Reader

Identec Solutions AG
RFID Reader - FCC ID OO4-ILR-IPM350N - Identec Solutions AG
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Apr 18, 2010
Application Purpose
Original Equipment
Date of Application
Apr 18, 2010
Equipment Note
RFID Reader
Frequency Range
902.20000000 - 927.50000000
Company
Identec Solutions AG
Country
Austria

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

ILR 350 Series i-PORT M 350, i-SAT 300 RTLS, i-PORT M 350 RTLS Installation and Operation Manual RTLS Hardware and Installation Manual Page 2 of 30 Proprietary Notice This document contains confidential information proprietary to IDENTEC SOLUTIONS and may not be used or disclosed to other parties in whole or in part without prior written authorization from IDENTEC SOLUTIONS. Disclaimer and Limitation of Liability IDENTEC SOLUTIONS AG and its affiliates, subsidiaries, officers, directors, employees and agents provide the information contained in this Manual on an “as-is” basis and do not make any express or implied warranties or representations with respect to such information including, without limitation, warranties as to non-infringement, reliability, fitness for a particular purpose, usefulness, completeness, accuracy or up-to-dateness. IDENTEC SOLUTIONS shall not in any circumstances be liable to any person for any special, incidental, indirect or consequential damages, including without limitation, damages resulting from use of or reliance on information presented herein, or loss of profits or revenues or costs of replacement goods, even if informed in advance of the possibility of such damages. Trademarks “IDENTEC SOLUTIONS”, “Intelligent Long Range”, “ILR” and the stylized “i” are registered trademarks and “i-Q”, “i-D”, “i-B”, “i-CARD”, “i-PORT”, “i-LINKS”, “Solutions. It’s in our name.”, “Smarten up your assets” are trademarks of IDENTEC SOLUTIONS, Inc. and/or IDENTEC SOLUTIONS AG. Copyright Notice Copyright © 2007 IDENTEC SOLUTIONS. All rights reserved. No part of this document may be reproduced or transmitted in any form by any means, photographic, electronic, mechanical or otherwise, or used in any information storage and retrieval system, without the prior written permission of IDENTEC SOLUTIONS. Issue 0 / March 2010 – 17. March 2010 – IDENTEC SOLUTIONS AG, Millennium Park 2, 6890 Lustenau, Austria Phone +43 5577 87387-0, Fax +43 5577 87387-15 [email protected] www.identecsolutions.com Subject to alteration without prior notice. © Copyright IDENTEC SOLUTIONS 2008 Printed in Germany i-PORT M 350, i-SAT 300 RTLS, i-PORT M 350 RTLS Page 3 of 30 Radio Frequency Compliance Statement IDENTEC SOLUTIONS is the responsible party for the compliance of the following devices: MODEL: i-PORT M 350 Region/Country Organization Marking EUROPE: EC CE USA: FCC FCC ID OO4-ILR-IPM350N Canada: Industry Canada IC:3538A-IPM350N MODEL: i-SAT 300 RTLS Region/Country Organization Marking EUROPE: EC CE USA: FCC FCC ID OO4-ILR-ISAT300 Canada: Industry Canada IC:3538A-ISAT300 MODEL: i-PORT M 350 RTLS Region/Country Organization Marking EUROPE: EC CE USA: FCC FCC ID OO4-ILR-IPM350RT Canada: Industry Canada IC:3538A-IPM350RT The user(s) of these products are cautioned to only use accessories and peripherals approved, in advance, by IDENTEC SOLUTIONS. The use of accessories and peripherals, other than those approved by IDENTEC SOLUTIONS, or any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Warning: This product requires professional installation. Any frequency and RF-power setting not expressly authorized by Identec Solutions is prohibited and will void the users authority to operate the equipment. RTLS Hardware and Installation Manual Page 4 of 30 European Notification according R&TTE Directive This equipment complies to Art. 6.4 of R&TTE Directive (1999/5/EC). It is tested for compliance with the following standards: ETSI EN 300 220, ETSI EN 300 440, ETSI EN 301 489, EN 60950. USA Notification This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The user(s) of these products are cautioned to only use accessories and peripherals approved, in advance, by IDENTEC SOLUTIONS. The use of accessories and peripherals, other than those approved by IDENTEC SOLUTIONS, or any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. The device has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Canada Certification To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted for successful communication. 2.4 GHz: This device has been designed to operate with the antennas listed below, and having a maximum gain of 6.0 dBi. Antennas not included in this list or having a gain greater than 6.0 dBi are strictly prohibited for use with this device. The required antenna impedance is 50 ohms. 916 MHz: This device has been designed to operate with the antennas listed below, and having a maximum gain of 2.0 dBi. Antennas not included in this list or having a gain greater than 2.0 dBi are strictly prohibited for use with this device. The required antenna impedance is 50 ohms. List of antennas: 2.4 GHz: Huber & Suhner 90A-2400/360/6/0/V: 6.0 dBi, 50 ohms 916 MHz: Kathrein K751161: 2.0 dBi, 50 ohms i-PORT M 350, i-SAT 300 RTLS, i-PORT M 350 RTLS Page 5 of 30 This product contains components that are sens…

Text truncated - open the document above for the full version.

Cover Letter(s)

Request for Confidentiality PHOENIX TESTLAB GmbH Date: February 24, 2010 Product Certification Königswinkel 10 D 32825 Blomberg RE: Certification Application FCC ID: OO4-ILR-IPM350N Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the Commission’s Rule, the applicant hereby requests confidential treatment of information accompanying this application as outlined below: • Schematics • Block Diagram • Technical Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to rule 0.457, disclosure od this application and all accompanying documentation will not be made before the date of the GRANT for this application ́. Thank you for your attention in this matter. Applicant’s Company : TÜV SÜD SENTON GmbH address : Auessere Fruehlingstrasse 45, D-94315 Straubing Signature : Johann Roidt Job Title and Dept. : Technical Director

External Photos

FCC ID OO4-ILR-IPM350RT FCC ID OO4-ILR-IPM350RT FCC ID OO4-ILR-IPM350RT FCC ID OO4-ILR-IPM350RT FCC ID OO4-ILR-IPM350RT FCC ID OO4-ILR-IPM350RT

Internal Photos

FCC ID OO4-ILR-IPM350N FCC ID OO4-ILR-IPM350N FCC ID OO4-ILR-IPM350N FCC ID OO4-ILR-IPM350N FCC ID OO4-ILR-IPM350N FCC ID OO4-ILR-IPM350N FCC ID OO4-ILR-IPM350N

Test Report

TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton Test Report No. 69861-00626-4 (Edition 4) Page 1 of 57 Page(s) Prüfbericht / Test Report Nr. / No. 69861-00626-4 (Edition 4) Applicant: Identec Solutions AG Type of equipment: RFID Reader Type designation: i-PORT M350 RTLS Order No.: 1930298 Test standards: FCC Code of Federal Regulations, CFR 47, Part 15, Sections 15.107, 15.109, 15.205, 15.207, 15.215 and 15.249 Industry Canada Radio Standards Specifications RSS-Gen Issue 2, Sections 7.2.2, 7.2.3 and RSS-210 Issue 7, Sections 2.2, A2.9 (Category I Equipment) 02 April 2010 TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton Test Report No. 69861-00626-4 (Edition 4) Page 2 of 57 Page(s) Table of Contents 1 Description of the Equipment Under Test (EUT) ............................................................3 2 Administrative Data.........................................................................................................4 3 Identification of the Test Laboratory ...............................................................................5 4 Summary ........................................................................................................................6 5 Operation Mode and Configuration of EUT ....................................................................7 6 Measurement Procedures ..............................................................................................8 6.1 Conducted Output Power .........................................................................................8 6.2 Bandwidth Measurements ......................................................................................10 6.3 Conducted AC Powerline Emission........................................................................12 6.4 Radiated Emission Measurement 9 kHz to 30 MHz ...............................................14 6.5 Radiated Emission in Fully or Semi Anechoic Room .............................................16 6.6 Radiated Emission at Open Field Test Site............................................................18 7 Photographs Taken During Testing ..............................................................................20 8 Test Results for Transmitter .........................................................................................24 8.1 Occupied Bandwidth ..............................................................................................26 8.2 Bandwidth of the Emission .....................................................................................29 8.3 Designation of Emissions .......................................................................................32 8.4 Restricted Bands of Operation and Band Edge Compliance..................................33 8.5 Conducted Powerline Emission Measurement 150 kHz to 30 MHz ......................35 8.6 Radiated Emission Measurement 9 kHz to 30 MHz ..............................................38 8.7 Radiated Emission Measurement 30 MHz to 10 GHz ...........................................40 8.8 Exposure of Humans to RF Fields..........................................................................48 9 Test Results for Receiver .............................................................................................50 9.1 Radiated Emission Measurement 30 MHz to 5 GHz .............................................51 10 Referenced Regulations ...............................................................................................55 11 Revision History ............................................................................................................57 TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton Test Report No. 69861-00626-4 (Edition 4) Page 3 of 57 Page(s) 1 Description of the Equipment Under Test (EUT) General data of EUT Type designation 1 : i-PORT M350 RTLS Parts 2 : Serial number(s): 09255M0101 Manufacturer: Identec Solutions AG Type of equipment: RFID Reader Version: As delivered FCC ID: OO4-ILR-XXX Additional parts/accessories: Technical data of EUT Application frequency range: 902 - 928 MHz Frequency range: Operating frequency: 902.2 - 927.5.0 MHz Type of modulation: F1D Pulse train: N/A Pulse width: N/A Number of RF-channels: 1 Channel spacing: N/A Designation of emissions 3 : 100K0F1D Type of antenna: External Type of antenna: Kathrein K751161: 2.0 dBi, 50 ohms 806 – 960 MHz Connection of antenna: detachable not detachable Type of power supply: DC supply Specifications for power supply: nominal voltage: 24 V minimum voltage: 18 V maximum voltage: 30 V nominal frequency: DC Hz 1 Type designation of the system if EUT consists of more than one part. 2 Type designations of the parts of the system, if applicable. 3 Also known as "Class of Emission". TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton Test Report No. 69861-00626-4 (Edition 4) Page 4 of 57 Page(s) 2 Administrative Data Application details Applicant (full address): Identec Solutions AG Millenium Park 2 A-6890 Lustenau - Austria Contact person: Hans-Guenther Meuthen Order number: 1930298 Receipt of EUT: 21 July 2009 Date(s) of test: August 2009 Note(s): Mr Meuthen attended testing on 21 and 22 July 2009 Report details Report number: 69861-00626-4 Edition: 3 Issue date: April 2, 2010 TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton Test Report No. 69861-00626-4 (Edition 4) Page 5 of 57 Page(s) 3 Identification of the Test Laboratory Details of the Test Laboratory Company name: TÜV SÜD SENTON GmbH Address: Aeussere Fruehlin…

Text truncated - open the document above for the full version.

Test Report

Test Equipment List with Calibration Data Seite 1 von 2 Test report number(s): Date of test: 69861-0626-2/-4 08/2009 Date of Calibration Type Inv.-No. Type Designation Serial Number Manufacturer Calibration Organization Last Next Test receiver 1025 ESVP 881120/024 Rohde & Schwarz Rohde & Schwarz 03/2008 09/2009 Test receiver 1028 ESHS10 860043/016 Rohde & Schwarz Rohde & Schwarz 02/2009 08/2010 EMI Test receiver 1569 ESMI 839379/013 Rohde & Schwarz Rohde & Schwarz 04/2007 10/2009 EMI test receiver 1711 ESPI7 836914/0002 Rohde & Schwarz Rohde & Schwarz 10/2008 04/2010 EMI test receiver 1863 ESCI 100008 Rohde & Schwarz Rohde & Schwarz 06/2008 06/2010 EMI test receiver 2010 ESPI7 101018 Rohde & Schwarz Rohde & Schwarz 03/2008 03/2010 Test receiver 2031 ESVP 891846/003 Rohde & Schwarz Rohde & Schwarz 10/2008 04/2010 Spectrum analyser 1666 FSP30 100063 Rohde & Schwarz Rohde & Schwarz 10/2007 10/2009 Preamplifier 1142 R14601 13120026 Advantest TÜV SÜD SENTON 04/2008 04/2010 Preamplifier 1484 ACO/180-3530 32641 CTT TÜV SÜD SENTON 05/2008 11/2009 Preamplifier 1651 CPA9231A 3393 Schaffner Electrotest TÜV SÜD SENTON 05/2008 11/2009 Preamplifier 1684 AFS3-00100800-32-LN 847743 MITEQ TÜV SÜD SENTON 05/2008 11/2009 V-network 1059 ESH3-Z5 894785/005 Rohde & Schwarz Rohde & Schwarz 05/2009 05/2012 V-network 1060 ESH3-Z5 862770/021 Rohde & Schwarz Rohde & Schwarz 01/2007 01/2010 V-network 1218 ESH3-Z5 830952/025 Rohde & Schwarz Rohde & Schwarz 07/2008 07/2011 Loop antenna 1016 HFH2-Z2 882964/0001 Rohde & Schwarz Rohde & Schwarz 12/2007 12/2009 Double ridged waveguide horn antenna 1516 3115 9508-4553 EMCO Elektronik ARC 05/2008 05/2011 Biconical Antenna 1518 HK116 842204/01 Rohde & Schwarz Rohde & Schwarz 06/2008 12/2009 Logarithmic-periodic antenna 1519 HL223 841516/23 Rohde & Schwarz Rohde & Schwarz 06/2008 12/2009 TRILOG broadband antenna 1722 VULB 9163 9163-188 Schwarzbeck Schwarzbeck 04/2008 10/2009 TRILOG Broadband Antenna 1802 VULB 9163 9163-214 Schwarzbeck Schwarzbeck 03/2008 09/2009 Note: Date of next calibration contains maximum tolerance if applicable. Test Equipment List with Calibration Data Seite 2 von 2 Test report number(s): Date of test: 69861-0626-2/-4 08/2009 Date of Calibration Type Inv.-No. Type Designation Serial Number Manufacturer Calibration Organization Last Next Multimeter 1653 21 III 76530546 Fluke ZMK 05/2008 02/2011 Multimeter 1654 21 III 76381229 Fluke ZMK 03/2008 12/2010 Multimeter 1975 Fluke 77 III 92370108 Fluke ZMK 09/2008 06/2011 Multimeter 1976 Fluke 77 IV 93090238 Fluke ZMK 09/2008 06/2011 Digital multimeter 2025 Fluke 177 96720024 Fluke ZMK 09/2008 06/2011 Digital multimeter 2026 Fluke 177 96720025 Fluke ZMK 09/2008 06/2011 Power meter 1264 NRVS 836856/015 Rohde & Schwarz Rohde & Schwarz 05/2008 05/2011 Power sensor 1034 NRV-Z4 863828/015 Rohde & Schwarz Rohde & Schwarz 04/2008 07/2010 Attenuator 1638 4776-10 9412 Narda Narda 04/2008 10/2009 Horn antenna 3160-03 9112-1003 EMCO Elektronik Note 2 Horn antenna 3160-04 9112-1001 EMCO Elektronik Note 2 Horn antenna 1012 3160-05 9112-1001 EMCO Elektronik Note 2 Horn antenna 1013 3160-06 9112-1001 EMCO Elektronik Note 2 Horn antenna 1014 3160-07 9112-1008 EMCO Elektronik Note 2 Horn antenna 3160-08 9112-1002 EMCO Elektronik Note 2 Horn antenna 3160-09 9403-1025 EMCO Elektronik Note 2 Horn antenna 3160-10 399185 EMCO Elektronik Note 2 Note 1: Date of next calibration contains maximum tolerance if applicable. Note 2: According to manufacturer's specifications no calibration is required but mechanical check only. This check is performed before every test sequence. Note: Date of next calibration contains maximum tolerance if applicable.

Test Setup Photos

TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: w ww.tuev-sued.com/senton Test Report No. 69861-00626-4 Page 21 of 55 Page(s) Test setup for conducted AC powerline emission measurement TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton Test Report No. 69861-00626-4 Page 22 of 63 Pages Test setup for radiated emission measurement 9 kHz – 30 MHz TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: w ww.tuev-sued.com/senton Test Report No. 69861-00626-4 Page 23 of 55 Page(s) Test setup for radiated emission measurement (fully anechoic room)

Contact Information

Applicant

Karl Heinz Feierle(VP Hardware Development)
[email protected]43-5577-87387Fax: 43-5577-87387-15

Test Firm

TUV SUD Product Service GmbH PS-EMC-STRRainer Heller
[email protected]49-09421-5522-20Fax: 49-09421-5522-99

Technical Specifications

#Rule PartsFrequency RangePower Output
115C902.2 MHz - 927.5 MHz-
Confidentiality
Long Term

Other Applications from Identec Solutions AG

iMARK EC and iMARK IC - FCC ID OO4-IDS1014 - Identec Solutions AG
OO4-IDS1014

iMARK EC and iMARK IC

Sep 26, 2024

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
iQ350 RNB tag - FCC ID OO4-IDS1009 - Identec Solutions AG
OO4-IDS1009

iQ350 RNB tag

Mar 24, 2024

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
iPOINT Si UHF / NFC / LF reader - FCC ID OO4-IDS1001 - Identec Solutions AG
OO4-IDS1001

iPOINT Si UHF / NFC / LF reader

Dec 17, 2020

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
iPoint X (ATEX) UHF / NFC / LF reader - FCC ID OO4-IDS1002 - Identec Solutions AG
OO4-IDS1002

iPoint X (ATEX) UHF / NFC / LF reader

Oct 08, 2020

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
iQ355 (X)P Personal Tag - FCC ID OO4-IDS1000 - Identec Solutions AG
OO4-IDS1000

iQ355 (X)P Personal Tag

May 03, 2020

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter