FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Identec Solutions AG/
  3. OO4-ILR-IQ350HHX

OO4-ILR-IQ350HHXRFID System

Identec Solutions AG
RFID System - FCC ID OO4-ILR-IQ350HHX - Identec Solutions AG
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Jan 30, 2012
Application Purpose
Original Equipment
Date of Application
Jan 30, 2012
Equipment Note
RFID System
Frequency Range
919.00000000 - 920.00000000
Company
Identec Solutions AG
Country
Austria

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

ILR 350 Series i-Q350 HHX, Hothead Tag Operation Manual PRELIMINARY VISIBILITY DELIVERED. PAGE 2 OF 13 Proprietary Notice This document contains confidential information proprietary to IDENTEC SOLUTIONS and may not be used or disclosed to other parties in whole or in part without prior written authorization from IDENTEC SOLUTIONS. Disclaimer and Limitation of Liability IDENTEC SOLUTIONS AG and its affiliates, subsidiaries, officers, directors, employees and agents do not make any express or implied warranties or representations with respect to such information including, without limitation, warranties as to non-infringement, reliability, suitability for a particular purpose and accuracy. IDENTEC SOLUTIONS shall not under any circumstances be liable to any person for any special, incidental, indirect or consequential damages, including without limitation, damages resulting from use of or reliance on information presented herein, or loss of profits or revenues or costs of replacement goods, even if informed in advance of the possibility of such damages. Trademarks ―IDENTEC SOLUTIONS‖, ―Intelligent Long Range‖, ―ILR‖ and the stylized ―i‖ are registered trademarks and ―i-Q‖, ―i-D‖, ―i-B‖, ―i-CARD‖, ―i-PORT‖, ―i-LINKS‖, ―Visibility Delivered‖ are trademarks of IDENTEC SOLUTIONS, Inc. and/or IDENTEC SOLUTIONS AG. Copyright Notice Copyright © 2011 IDENTEC SOLUTIONS. All rights reserved. No part of this document may be reproduced or transmitted in any form by any means, photographic, electronic, mechanical or otherwise, or used in any information storage and retrieval system, without the prior written permission of IDENTEC SOLUTIONS. Issue 1 / September 2011 – 29. September 2011 – IDENTEC SOLUTIONS AG, Millennium Park 2, 6890 Lustenau, Austria Phone: +43 5577 87387- 0, Fax: +43 5577 87387-15 E-Mail: [email protected] www.identecsolutions.com Subject to alteration without prior notice. VISIBILITY DELIVERED. PAGE 3 OF 13 © Copyright IDENTEC SOLUTIONS 2010 IDENTEC SOLUTIONS is the responsible party for the compliance of the following devices: MODELS: i-Q350 HHX Region/Country Organization Marking EUROPE: EC CE USA FCC FFC ID 004-ILR-IQ350HHX Canada Industry Canada IC: 3538A-IQ350HHX European Notification according R&TTE Directive This equipment complies to Art. 6.4 of R&TTE Directive (1999/5/EC). It is tested for compliance with the following standards: ETSI EN 300 220, ETSI EN 301 489, EN 60950 USA Notification This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The user(s) of these products are cautioned to only use accessories and peripherals approved, in advance, by IDENTEC SOLUTIONS. The use of accessories and peripherals, other than those approved by IDENTEC SOLUTIONS, or any changes or modifications not expressly approved by the party responsible for compliance could void the users’ authority to operate the equipment. The device has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Printed in Austria VISIBILITY DELIVERED. PAGE 4 OF 13 Contents 1 INTRODUCTION ............................................................................................................ 5 1.1 PREPARATIONS ............................................................................................................... 5 1.2 RECOMMENDED PROCEDURE .............................................................................................. 5 1.3 SCOPE OF THIS DOCUMENT ................................................................................................ 5 1.4 RESPONSIBILITY ............................................................................................................. 5 1.5 ASSOCIATED DOCUMENTS ................................................................................................. 5 1.6 SCOPE OF DELIVERY—VISUAL INSPECTION ............................................................................ 5 2 SAFETY PRECAUTIONS ................................................................................................. 6 3 GENERAL ....................................................................................................................... 8 3.1 OPTICAL IDENTIFICATION OF THE TAG ................................................................................. 8 4 CONFIGURATION OF THE TAG ...................................................................................... 9 4.1 PING RATE .................................................................................................................. 10 5 MAINTENANCE ............................................................................................................ 11 5.1 GENERAL .................................................................................................................... 11 5.2 REGULAR CLEANING OF THE SURFACE ................................................................................ 11 5.3 PRECAUTIONARY MAINTENANCE ........................................................................................ 11 5.4 RETURNS .................................................................................................................... 11 6 TECHNICAL DATA .............................…

Text truncated - open the document above for the full version.

Cover Letter(s)

Request for Confidentiality PHOENIX TESTLAB GmbH Date: 12 December 2011 Product Certification Königswinkel 10 D 32825 Blomberg RE: Certification Application FCC ID: OO4-ILR-IQ350HHX Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the Commission’s Rule, the applicant hereby requests confidential treatment of information accompanying this application as outlined below:  Schematics  Block Diagram  Technical Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to rule 0.457, disclosure od this application and all accompanying documentation will not be made before the date of the GRANT for this application ́. Thank you for your attention in this matter. Applicant’s Company : TÜV SÜD SENTON GmbH address : Auessere Fruehlingstrasse 45, D-94315 Straubing Signature : Johann Roidt Job Title and Dept. : Technical Director

External Photos

i-Q350 HHX External Photographs

ID Label/Location Info

i-Q350 HHX Label Information

Internal Photos

i-Q350 HHX Internal Photographs

Test Report

Note: The test data of this report is related only to the individual item which has been tested. This report shall not be reproduced except in full extent without the written approval of the testing laboratory. Trade Register Straubing HRB 9302 V.A.T. DE 131457658 Information pursuant to Section 2(1) DL-InfoV (Germany) at www.tuev-sued.com/imprint Managing Director: Johann Roidt Phone: +49 9421 55 22-0 Fax: +49 9421 55 22-99 www.tuev-sued.de/senton TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Prüfbericht / Test Report Nr. / No. 69861-04040-1 (Edition 1) Applicant: IDENTEC Solutions AG Type of equipment: Active Transponder Tag Type designation: i-Q350 HHX Hothead Order No.: 1130378 Test standards: FCC Code of Federal Regulations, CFR 47, Part 15, Sections 15.107, 15.109, 15.205, 15.207, 15.215 and 15.249 Industry Canada Radio Standards Specifications RSS-GEN Issue 3, Sections 6.2, 7.2.2, 7.2.4 and RSS-210 Issue 8, Section A2.9 (Category I Equipment) November 10, 2011 Page 1 of 82 TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.de/senton Test Report No. 69861-04040-1 (Edition 1) Page 2 of 82 Pages Table of Contents 1 Description of the Equipment Under Test (EUT) ............................................................ 3 2 Administrative Data ........................................................................................................ 4 3 Identification of the Test Laboratory ............................................................................... 5 4 Summary ........................................................................................................................ 6 5 Operation Mode and Configuration of EUT .................................................................... 7 6 Measurement Procedures .............................................................................................. 8 6.1 Bandwidth Measurements ....................................................................................... 8 6.2 Radiated Emission Measurement 9 kHz to 30 MHz ................................................. 9 6.3 Radiated Emission in Fully or Semi Anechoic Room ............................................. 11 6.4 Radiated Emission at Alternative Test Site ............................................................ 13 7 Photographs Taken During Testing .............................................................................. 15 8 Test Results for Transmitter ......................................................................................... 20 8.1 Occupied Bandwidth .............................................................................................. 22 8.2 Bandwidth of the Emission..................................................................................... 28 8.3 Designation of Emissions ....................................................................................... 32 8.4 Restricted Bands of Operation ............................................................................... 33 8.5 Radiated Emission Measurement 9 kHz to 30 MHz .............................................. 36 8.6 Radiated Emission Measurement 30 MHz to 10 GHz ........................................... 38 8.7 Exposure of Humans to RF Fields ......................................................................... 41 9 Test Results for Receiver ............................................................................................. 43 9.1 Radiated Emission Measurement 30 MHz to 5 GHz ............................................. 44 10 Referenced Regulations ............................................................................................... 45 11 Test Equipment List with Calibration Data ................................................................... 47 12 Revision History ........................................................................................................... 48 Annex A Charts taken during testing .............................................................................. 49 TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.de/senton Test Report No. 69861-04040-1 (Edition 1) Page 3 of 82 Pages 1 Description of the Equipment Under Test (EUT) General data of EUT Type designation 1 : i-Q350 HHX Hothead Parts 2 : Serial number(s): 111.002 Manufacturer: IDENTEC Solutions AG Type of equipment: Active Transponder Tag Version: As received FCC ID: Additional parts/accessories: Technical data of EUT Application frequency range: 902 - 928 MHz Frequency range: 919 MHz, 920 MHz Operating frequency: 919 MHz, 920 MHz Type of modulation: FSK Pulse train: --- Pulse width: --- Number of RF-channels: 2 Channel spacing: 1 MHz Designation of emissions 3 : 72K0F1D Type of antenna: Integrated on printed board Size/length of antenna: 2 x 1 cm Connection of antenna: detachable not detachable Type of power supply: Battery supply Specifications for power supply: nominal voltage: 3.00 V V 1 Type designation of the system if EUT consists of more than one part. 2 Type designations of the parts of the system, if applicable. 3 Also known as "Class of Emission". TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.de/senton Test Report No. 69861-04040-1 (Edition 1) Page 4 of 82 Pages 2 Administrative Data Application details Applicant (full address): IDENTEC Solutions AG Millennium Park 2 A-6890 Lustenau Österreich Contact person: Herr Simon Prior Order number: 1130378 Receipt of EUT: Date(s) of test: Note(s): Report details Report number: 69861-04040-1 Edition: 1 Issue date: 10.11.2011 TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.de/senton Test Report No. 69861-04040-1 (Edition 1)…

Text truncated - open the document above for the full version.

Test Setup Photos

Note: The test data of this report is related only to the individual item which has been tested. This report shall not be reproduced except in full extent without the written approval of the testing laboratory. Trade Register Straubing HRB 9302 V.A.T. DE 131457658 Information pursuant to Section 2(1) DL-InfoV (Germany) at www.tuev-sued.com/imprint Managing Director: Johann Roidt Phone: +49 9421 55 22-0 Fax: +49 9421 55 22-99 www.tuev-sued.de/senton TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Prüfbericht / Test Report Nr. / No. 69861-04040-1 (Edition 1) Applicant: IDENTEC Solutions AG Type of equipment: Active Transponder Tag Type designation: i-Q350 HHX Hothead Order No.: 1130378 Test standards: FCC Code of Federal Regulations, CFR 47, Part 15, Sections 15.107, 15.109, 15.205, 15.207, 15.215 and 15.249 Industry Canada Radio Standards Specifications RSS-GEN Issue 3, Sections 6.2, 7.2.2, 7.2.4 and RSS-210 Issue 8, Section A2.9 (Category I Equipment) November 10, 2011 Page 1 of 82 TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.de/senton Test Report No. 69861-04040-1 (Edition 1) Page 2 of 82 Pages Table of Contents 1 Description of the Equipment Under Test (EUT) ............................................................ 3 2 Administrative Data ........................................................................................................ 4 3 Identification of the Test Laboratory ............................................................................... 5 4 Summary ........................................................................................................................ 6 5 Operation Mode and Configuration of EUT .................................................................... 7 6 Measurement Procedures .............................................................................................. 8 6.1 Bandwidth Measurements ....................................................................................... 8 6.2 Radiated Emission Measurement 9 kHz to 30 MHz ................................................. 9 6.3 Radiated Emission in Fully or Semi Anechoic Room ............................................. 11 6.4 Radiated Emission at Alternative Test Site ............................................................ 13 7 Photographs Taken During Testing .............................................................................. 15 8 Test Results for Transmitter ......................................................................................... 20 8.1 Occupied Bandwidth .............................................................................................. 22 8.2 Bandwidth of the Emission..................................................................................... 28 8.3 Designation of Emissions ....................................................................................... 32 8.4 Restricted Bands of Operation ............................................................................... 33 8.5 Radiated Emission Measurement 9 kHz to 30 MHz .............................................. 36 8.6 Radiated Emission Measurement 30 MHz to 10 GHz ........................................... 38 8.7 Exposure of Humans to RF Fields ......................................................................... 41 9 Test Results for Receiver ............................................................................................. 43 9.1 Radiated Emission Measurement 30 MHz to 5 GHz ............................................. 44 10 Referenced Regulations ............................................................................................... 45 11 Test Equipment List with Calibration Data ................................................................... 47 12 Revision History ........................................................................................................... 48 Annex A Charts taken during testing .............................................................................. 49 TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.de/senton Test Report No. 69861-04040-1 (Edition 1) Page 3 of 82 Pages 1 Description of the Equipment Under Test (EUT) General data of EUT Type designation 1 : i-Q350 HHX Hothead Parts 2 : Serial number(s): 111.002 Manufacturer: IDENTEC Solutions AG Type of equipment: Active Transponder Tag Version: As received FCC ID: Additional parts/accessories: Technical data of EUT Application frequency range: 902 - 928 MHz Frequency range: 919 MHz, 920 MHz Operating frequency: 919 MHz, 920 MHz Type of modulation: FSK Pulse train: --- Pulse width: --- Number of RF-channels: 2 Channel spacing: 1 MHz Designation of emissions 3 : 72K0F1D Type of antenna: Integrated on printed board Size/length of antenna: 2 x 1 cm Connection of antenna: detachable not detachable Type of power supply: Battery supply Specifications for power supply: nominal voltage: 3.00 V V 1 Type designation of the system if EUT consists of more than one part. 2 Type designations of the parts of the system, if applicable. 3 Also known as "Class of Emission". TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.de/senton Test Report No. 69861-04040-1 (Edition 1) Page 4 of 82 Pages 2 Administrative Data Application details Applicant (full address): IDENTEC Solutions AG Millennium Park 2 A-6890 Lustenau Österreich Contact person: Herr Simon Prior Order number: 1130378 Receipt of EUT: Date(s) of test: Note(s): Report details Report number: 69861-04040-1 Edition: 1 Issue date: 10.11.2011 TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.de/senton Test Report No. 69861-04040-1 (Edition 1)…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Karl Heinz Feierle(VP Hardware Development)
[email protected]43-5577-87387Fax: 43-5577-87387-15

Test Firm

TUV SUD Product Service GmbH PS-EMC-STRRainer Heller
[email protected]49-09421-5522-20Fax: 49-09421-5522-99

Technical Specifications

#Rule PartsFrequency RangePower Output
115C919 MHz - 920 MHz-
Confidentiality
Long Term

Other Applications from Identec Solutions AG

iMARK EC and iMARK IC - FCC ID OO4-IDS1014 - Identec Solutions AG
OO4-IDS1014

iMARK EC and iMARK IC

Sep 26, 2024

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
iQ350 RNB tag - FCC ID OO4-IDS1009 - Identec Solutions AG
OO4-IDS1009

iQ350 RNB tag

Mar 24, 2024

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
iPOINT Si UHF / NFC / LF reader - FCC ID OO4-IDS1001 - Identec Solutions AG
OO4-IDS1001

iPOINT Si UHF / NFC / LF reader

Dec 17, 2020

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
iPoint X (ATEX) UHF / NFC / LF reader - FCC ID OO4-IDS1002 - Identec Solutions AG
OO4-IDS1002

iPoint X (ATEX) UHF / NFC / LF reader

Oct 08, 2020

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
iQ355 (X)P Personal Tag - FCC ID OO4-IDS1000 - Identec Solutions AG
OO4-IDS1000

iQ355 (X)P Personal Tag

May 03, 2020

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter