FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Identec Solutions AG/
  3. OO4-ILR-IQ350TL

OO4-ILR-IQ350TLRFID System

Identec Solutions AG
RFID System - FCC ID OO4-ILR-IQ350TL - Identec Solutions AG
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Dec 28, 2009
Application Purpose
Original Equipment
Date of Application
Dec 28, 2009
Equipment Note
RFID System
Frequency Range
919.00000000 - 920.00000000
Company
Identec Solutions AG
Country
Austria

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗
↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

ILR 350 Series Installation and Operation Manual for Tag Models i-Q350, i-Q350T, i-Q350L, i-Q350TL Installation and Operation Manual Page 2 of 11 Proprietary Notice This document contains confidential information proprietary to IDENTEC SOLUTIONS and may not be used or disclosed to other parties in whole or in part without prior written authorization from IDENTEC SOLUTIONS. Disclaimer and Limitation of Liability IDENTEC SOLUTIONS AG and its affiliates, subsidiaries, officers, directors, employees and agents provide the information contained in this Manual on an “as-is” basis and do not make any express or implied warranties or representations with respect to such information including, without limitation, warranties as to non- infringement, reliability, fitness for a particular purpose, usefulness, completeness, accuracy or up-to- dateness. IDENTEC SOLUTIONS shall not in any circumstances be liable to any person for any special, incidental, indirect or consequential damages, including without limitation, damages resulting from use of or reliance on information presented herein, or loss of profits or revenues or costs of replacement goods, even if informed in advance of the possibility of such damages. Trademarks “IDENTEC SOLUTIONS”, “Intelligent Long Range”, “ILR” and the stylized “i” are registered trademarks and “i-Q”, “i-D”, “i-B”, “i-CARD”, “i-PORT”, “i-LINKS”, “Solutions. It’s in our name.”, “Smarten up your assets” are trademarks of IDENTEC SOLUTIONS, Inc. and/or IDENTEC SOLUTIONS AG. Copyright Notice Copyright © 2007 IDENTEC SOLUTIONS. All rights reserved. No part of this document may be reproduced or transmitted in any form by any means, photographic, electronic, mechanical or otherwise, or used in any information storage and retrieval system, without the prior written permission of IDENTEC SOLUTIONS. Reg.-No. IM.0761.EN Issue 0 / September 2009 – 22. September 2009 – IDENTEC SOLUTIONS AG, Millenium Park 2, 6890 Lustenau, Österreich Phone: +43 5577 87387- 0, Fax: +43 5577 87387-15 E-Mail: [email protected] www.identecsolutions.com Subject to alteration without prior notice. © Copyright IDENTEC SOLUTIONS 2009 Printed in Germany i-Q350TL Tag Manual Page 3 of 11 Radio Frequency Compliance Statement IDENTEC SOLUTIONS is the responsible party for the compliance of the following devices: MODELS: i-Q350, i-Q350L, i-Q350T, i-Q350TL Region/CountryOrganization Marking EUROPE: EC CE USA FCC FFC ID IQ350TL Canada Industry Canada IC:3538A-IQ350TL The user(s) of these products are cautioned to only use accessories and peripherals approved, in advance, by IDENTEC SOLUTIONS. The use of accessories and peripherals, other than those approved by IDENTEC SOLUTIONS, or any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. European Notification according R&TTE Directive This equipment complies to Art. 6.4 of R&TTE Directive (1999/5/EC). It is tested for compliance with the following standards: ETSI EN 300 220, ETSI EN 301 489, EN 60950 USA Notification This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The user(s) of these products are cautioned to only use accessories and peripherals approved, in advance, by IDENTEC SOLUTIONS. The use of accessories and peripherals, other than those approved by IDENTEC SOLUTIONS, or any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Installation and Operation Manual Page 4 of 11 Contents 1 INTRODUCTION ...........................................................................................................5 1.1 PREPARATIONS............................................................................................................ 5 1.2 RECOMMENDED PROCEDURE............................................................................................ 5 1.3 SCOPE OF THIS DOCUMENT............................................................................................. 5 1.4 RESPONSIBILITY........................................................................................................... 5 1.5 ASSOCIATED DOCUMENTS............................................................................................... 5 1.6 SCOPE OF DELIVERY—VISUAL INSPECTION.......................................................................... 5 2 SAFETY PRECAUTIONS .................................................................................................6 3 TAG MOUNTING TECHNIQUES .....................................................................................7 3.1 RIVETS...................................................................................................................... 7 3.2 SCREWS..................................................................................................................... 8 4 MAINTENANCE .............................................................................................................9 4.1 GENERAL................................................................................................................... 9 4.2 PRECAUTIONARY MAINTENANCE........................................................................................ 9 4.3 RETURNS................................................................................................................... 9 5 TECHNICAL DATA .......................................................................................................10 i-Q350TL Tag Manual Page 5 of 11 1 Introduction 1.1 Preparations This installation manual must be read carefully prior to starting the installation. The described installation works assume that installation materials like cab…

Text truncated - open the document above for the full version.

Cover Letter(s)

Request for Confidentiality PHOENIX TESTLAB GmbH Date: November 17, 2009 Product Certification Königswinkel 10 D 32825 Blomberg RE: Certification Application FCC ID: OO4-ILR-IQ350TL Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the Commission’s Rule, the applicant hereby requests confidential treatment of information accompanying this application as outlined below: • Schematics • Block Diagram • Technical Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to rule 0.457, disclosure od this application and all accompanying documentation will not be made before the date of the GRANT for this application ́. Thank you for your attention in this matter. Applicant’s Company : TÜV SÜD SENTON GmbH address : Auessere Fruehlingstrasse 45, D-94315 Straubing Signature : Johann Roidt Job Title and Dept. : Technical Director

Cover Letter(s)

i-Q350 optional configuration Hans-Günter Meuthen 08.07.09 The tag i-Q350 is offered with following options Type Description i-Q350TL Equipped with Temperatur sensor and LF Receiver i-Q350T Equipped with Temperatur sensor i-Q350L Equipped LF Receiver i-Q350 Low cost Because the i-Q350TL is a superset of the other tags, only this type is tested. More details you will find in the functional description and block diagram. All four tags have common transponder board, enclosure, battery and antenna. These four tags have the same FCC ID OO4-ILR-IQ350TL and for Canada the marking is IC:3538A-IQ350TL.

External Photos

FCC ID OO4-ILR-IQ350TL FCC ID OO4-ILR-IQ350TL FCC ID OO4-ILR-IQ350TL FCC ID OO4-ILR-IQ350TL

ID Label/Location Info

Label / Label Location i-Q350 9/21/2009 i-Q350-Label and Label Location.doc Simon Prior Page 1/4 1.1 Label, Label Location and Label Package i-Q350T SL/NA Label / Label Location i-Q350 9/21/2009 i-Q350-Label and Label Location.doc Simon Prior Page 2/4 1.2 Label, Label Location and Label Package i-Q350L SL/NA Label / Label Location i-Q350 9/21/2009 i-Q350-Label and Label Location.doc Simon Prior Page 3/4 1.3 Label, Label Location and Label Package i-Q350TL SL/NA Label / Label Location i-Q350 9/21/2009 i-Q350-Label and Label Location.doc Simon Prior Page 4/4 1.4 Label, Label Location and Label Package i-Q350 SL/NA

Internal Photos

FCC ID OO4-ILR-IQ350TL FCC ID OO4-ILR-IQ350TL FCC ID OO4-ILR-IQ350TL FCC ID OO4-ILR-IQ350TL

Internal Photos

FCC ID OO4-ILR-IQ350TL FCC ID OO4-ILR-IQ350TL FCC ID OO4-ILR-IQ350TL FCC ID OO4-ILR-IQ350TL

Test Report

Note: The test data of this report is related only to the individual item which has been tested. This report shall not be reproduced except in full extent without the written approval of the testing laboratory. Test Report No. 69861-00627-4 (Edition 3) Page 1 of 66 Pages Prüfbericht / Test Report Nr. / No. 69861-00627-4 (Edition 3) Applicant: IDENTEC Solutions AG Type of equipment: Active UHF Transponder Tag Type designation: i-Q350TL Order No.: 1930298 Test standards: FCC Code of Federal Regulations, CFR 47, Part 15, Sections 15.107, 15.109, 15.111(a), 15.205, 15.207, 15.215 and 15.249 Industry Canada Radio Standards Specifications RSS-Gen Issue 2, Sections 7.2.2, 7.2.3 and RSS-210 Issue 7, Sections 2.2, A2.9 (Category I Equipment) Dezember 18, 2009 TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected] Test Report No. 69861-00627-4 (Edition 3) Page 2 of 66 Pages Table of Contents 1 Description of the Equipment Under Test (EUT)............................................................ 3 2 Administrative Data ........................................................................................................ 4 3 Identification of the Test Laboratory............................................................................... 5 4 Summary........................................................................................................................6 5 Operation Mode and Configuration of EUT .................................................................... 7 6 Measurement Procedures .............................................................................................. 8 6.1 Bandwidth Measurements ....................................................................................... 9 6.2 Radiated Emission Measurement 9 kHz to 30 MHz............................................... 10 6.3 Radiated Emission in Fully or Semi Anechoic Room ............................................. 12 6.4 Radiated Emission at Open Field Test Site ........................................................... 14 7 Photographs Taken During Testing.............................................................................. 16 8 Test Results for Transmitter ......................................................................................... 21 8.1 Occupied Bandwidth .............................................................................................. 23 8.2 Bandwidth of the Emission..................................................................................... 29 8.3 Designation of Emissions....................................................................................... 32 8.4 Restricted Bands of Operation............................................................................... 33 8.5 Radiated Emission Measurement 9 kHz to 30 MHz.............................................. 35 8.6 Radiated Emission Measurement 30 MHz to 10 GHz........................................... 36 8.7 Exposure of Humans to RF Fields ......................................................................... 39 9 Referenced Regulations............................................................................................... 41 10 Revision History ........................................................................................................... 43 11 Charts taken during testing .......................................................................................... 44 TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected] Test Report No. 69861-00627-4 (Edition 3) Page 3 of 66 Pages 1 Description of the Equipment Under Test (EUT) General data of EUT Type designation 1 : i-Q350TL Parts 2 : Serial number(s): 0.400.000.006 Manufacturer: IDENTEC Solutions AG Type of equipment: Active UHF Transponder Tag Version: As received FCC ID: Additional parts/accessories: Technical data of EUT Application frequency range: 902 - 928 MHz Frequency range: 920 - 919 MHz Operating frequency: 919 MHz Type of modulation: FSK Pulse train: --- Pulse width: --- Number of RF-channels: 2 Channel spacing: 1 MHz Designation of emissions 3 : 80K0F1D Type of antenna: Integrated Size/length of antenna: 6.5 cm Connection of antenna: detachable not detachable Type of power supply: Battery supply Specifications for power supply: nominal voltage: 3.60 V minimum voltage: 3.06 V maximum voltage: 3.60 V 1 Type designation of the system if EUT consists of more than one part. 2 Type designations of the parts of the system, if applicable. 3 Also known as "Class of Emission". TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected] Test Report No. 69861-00627-4 (Edition 3) Page 4 of 66 Pages 2 Administrative Data Application details Applicant (full address): IDENTEC Solutions AG Millennium Park 2 6890 Lustenau AUSTRIA Contact person: Mr. Simon Prior Order number: 1930298 Receipt of EUT: July 21, 2009 Date(s) of test: September - October 2009 December 2009 Note(s): Report details Report number: 69861-00627-4 Edition: 3 Issue date: December 18, 2009 TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected] Test Report No. 69861-00627-4 (Edition 3) Page 5 of 66 Pages 3 Identification of the Test Laboratory Details of the Test Laboratory Company name: TÜV SÜD SENTON GmbH Address: Aeussere Fruehlingstrasse 45 D-94315 Straubing Germany Laboratory accreditation: DAR-Registration No. DAT-PL-171/94-03 FCC test site registration number 90926 Industry Canada test site registration: 3050A-1 Contact person: Mr. Johann Roidt Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 TÜV S…

Text truncated - open the document above for the full version.

Test Report

Note 1: Date of next calibration contains maximum tolerance if applicable. Note 2: According to manufacturer's specifications no calibration is required but mechanical check only. This check is perform ed before every test sequence. Test Equipment List with Calibration Data Seite 1 von 2 Test report number(s): Date of test: 69861-00627-4 September/October 2009 Date of Calibration Type Inv.-No. Type Designation Serial Number Manufacturer Calibration Organization Last Next Test receiver 1028 ESHS10 860043/016 Rohde & Schwarz Rohde & Schwarz 02/2009 08/2010 EMI Test receiver 1569 ESMI 839379/013 Rohde & Schwarz Rohde & Schwarz 10/2009 01/2012 EMI test receiver 1711 ESPI7 836914/0002 Rohde & Schwarz Rohde & Schwarz 09/2009 03/2011 EMI test receiver 1863 ESCI 1166.5950K03 100008 Rohde & Schwarz Rohde & Schwarz 06/2008 12/2009 Test receiver 2031 ESVP 891846/003 Rohde & Schwarz Rohde & Schwarz 10/2008 04/2010 Spectrum analyser 1666 FSP30 100063 Rohde & Schwarz Rohde & Schwarz 10/2007 10/2009 Preamplifier 1142 R14601 13120026 Advantest TÜV SÜD SENTON 04/2008 04/2010 Preamplifier 1484 ACO/180-3530 32641 CTT TÜV SÜD SENTON 05/2008 11/2009 Preamplifier 1651 CPA9231A 3393 Schaffner Electrotest TÜV SÜD SENTON 05/2008 11/2009 Preamplifier 1684 AFS3-00100800-32-LN 847743 MITEQ TÜV SÜD SENTON 05/2008 11/2009 V-network 1059 ESH3-Z5 894785/005 Rohde & Schwarz Rohde & Schwarz 05/2009 05/2012 V-network 1060 ESH3-Z5 862770/021 Rohde & Schwarz Rohde & Schwarz 01/2007 01/2010 V-network 1218 ESH3-Z5 830952/025 Rohde & Schwarz Rohde & Schwarz 07/2008 07/2011 Loop antenna 1016 HFH2-Z2 882964/0001 Rohde & Schwarz Rohde & Schwarz 09/2009 03/2011 Double ridged waveguide horn antenna 1516 3115 9508-4553 EMCO Elektronik ARC 05/2008 05/2011 Biconical Antenna 1518 HK116 842204/01 Rohde & Schwarz Rohde & Schwarz 06/2008 12/2009 Logarithmic-periodic antenna 1519 HL223 841516/23 Rohde & Schwarz Rohde & Schwarz 06/2008 12/2009 TRILOG broadband antenna 1722 VULB 9163 9163-188 Schwarzbeck Schwarzbeck 04/2008 10/2009 Multimeter 1653 21 III 76530546 Fluke ZMK 05/2008 02/2011 Note 1: Date of next calibration contains maximum tolerance if applicable. Note 2: According to manufacturer's specifications no calibration is required but mechanical check only. This check is perform ed before every test sequence. Test Equipment List with Calibration Data Seite 2 von 2 Test report number(s): Date of test: 69861-00627-4 September/October 2009 Date of Calibration Type Inv.-No. Type Designation Serial Number Manufacturer Calibration Organization Last Next Multimeter 1654 21 III 76381229 Fluke ZMK 03/2008 12/2010 Multimeter 1975 Fluke 77 III 92370108 Fluke ZMK 09/2008 06/2011 Multimeter 1976 Fluke 77 IV 93090238 Fluke ZMK 09/2008 06/2011 Digital multimeter 2025 Fluke 177 96720024 Fluke ZMK 09/2008 06/2011 Digital multimeter 2026 Fluke 177 96720025 Fluke ZMK 09/2008 06/2011 Horn antenna 3160-03 9112-1003 EMCO Elektronik Note 2 Horn antenna 3160-04 9112-1001 EMCO Elektronik Note 2 Horn antenna 1012 3160-05 9112-1001 EMCO Elektronik Note 2 Horn antenna 1013 3160-06 9112-1001 EMCO Elektronik Note 2 Horn antenna 1014 3160-07 9112-1008 EMCO Elektronik Note 2 Horn antenna 3160-08 9112-1002 EMCO Elektronik Note 2 Horn antenna 3160-09 9403-1025 EMCO Elektronik Note 2 Horn antenna 3160-10 399185 EMCO Elektronik Note 2 Horn antenna 1516 3115 9508-4553 EMCO Elekronik 05/2008 05/2011 Note 1: Date of next calibration contains maximum tolerance if applicable. Note 2: According to manufacturer's specifications no calibration is required but mechanical check only. This check is perform ed before every test sequence. Note: Date of next calibration contains maximum tolerance if applicable.

Test Setup Photos

TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected] Test Report No. 69861-00627-4 (Edition 2) Page 17 of 50 Pages Test setup for radiated emission measurement 9 kHz – 30 MHz TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected] Test Report No. 69861-00627-4 (Edition 2) Page 18 of 50 Pages Test setup for radiated emission measurement (fully anechoic room) TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected] Test Report No. 69861-00627-4 (Edition 2) Page 19 of 50 Pages Test setup for radiated emission measurement (open field test site) TÜV SÜD SENTON GmbH Äußere Frühlingstraße 45 94315 Straubing Germany Phone: +49 9421 5522-0 Fax: +49 9421 5522-99 Web: www.tuev-sued.com/senton eMail: [email protected] Test Report No. 69861-00627-4 (Edition 2) Page 20 of 50 Pages Test setup for radiated emission measurement (open field test site) - continued -

Contact Information

Applicant

Karl Heinz Feierle(VP Hardware Development)
[email protected]43-5577-87387Fax: 43-5577-87387-15

Test Firm

TUV SUD Product Service GmbH PS-EMC-STRRainer Heller
[email protected]49-09421-5522-20Fax: 49-09421-5522-99

Technical Specifications

#Rule PartsFrequency RangePower Output
115C919 MHz - 920 MHz-
Confidentiality
Long Term

Other Applications from Identec Solutions AG

iMARK EC and iMARK IC - FCC ID OO4-IDS1014 - Identec Solutions AG
OO4-IDS1014

iMARK EC and iMARK IC

Sep 26, 2024

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
iQ350 RNB tag - FCC ID OO4-IDS1009 - Identec Solutions AG
OO4-IDS1009

iQ350 RNB tag

Mar 24, 2024

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
iPOINT Si UHF / NFC / LF reader - FCC ID OO4-IDS1001 - Identec Solutions AG
OO4-IDS1001

iPOINT Si UHF / NFC / LF reader

Dec 17, 2020

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
iPoint X (ATEX) UHF / NFC / LF reader - FCC ID OO4-IDS1002 - Identec Solutions AG
OO4-IDS1002

iPoint X (ATEX) UHF / NFC / LF reader

Oct 08, 2020

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
iQ355 (X)P Personal Tag - FCC ID OO4-IDS1000 - Identec Solutions AG
OO4-IDS1000

iQ355 (X)P Personal Tag

May 03, 2020

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter