FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shinko Electric Co Ltd/
  3. OPO199909010003

OPO199909010003CMC

Shinko Electric Co Ltd
CMC - FCC ID OPO199909010003 - Shinko Electric Co Ltd
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Feb 06, 2001
Application Purpose
Original Equipment
Date of Application
Nov 21, 2000
Equipment Note
CMC
Frequency Range
0.31580000 - 0.31580000
Company
Shinko Electric Co Ltd
Country
Japan

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Block Diagram

↗

External Photos

↗
↗
↗
↗
↗

ID Label/Location Info

↗
↗
↗
↗

Internal Photos

↗
↗
↗
↗

Operational Description

↗
↗

Schematics

↗
↗

Test Report

↗
↗
↗
↗
↗

Test Setup Photos

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FCC ID: OPO199909010003  SHINKO ELECTRIC CO.,LTD K44-2127  Rev.0  Communication unit CMC Operation Manual  i System Operation Manual of SHINKO Communication unit CMC K44-2127 Revision 0 Nov. 2, 2000 The information furnished herein by SHINKO ELECTRIC CO., LTD. is proprietary and confidential to SHINKO ELECTRIC CO., LTD. personnel and is not to be duplicated, published, or disclosed to any third party in whole or in part without permission from SHINKO ELECTRIC CO., LTD. FCC ID: OPO199909010003  SHINKO ELECTRIC CO.,LTD K44-2127  Rev.0  Communication unit CMC Operation Manual  ii Copyright © 2000 SHINKO ELECTRIC CO., LTD. ALL RIGHTS RESERVED. Unpublished rights reserved under the copyright laws of the United States. The information contained herein is provided pursuant to the terms of a License, Non- disclosure and/or Confidentiality Agreement and constitutes and contains valuable proprietary information and trade secrets of SHINKO ELECTRIC CO., LTD . , embodying substantial creative efforts and confidential information, ideas, and expressions. Accordingly, strict compliance with the terms and conditions of the governing Agreement, including, without limitation, all restrictions on use and disclosure, is required as a condition to the use of the information contained herein. Except as may be permitted in the applicable agreement, the information herein may not be reproduced or disclosed in whole or in part. Restricted Rights Legend Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph <c> (1) (ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.277-7013. SHINKO ELECTRIC CO., LTD. 100 Takegahana, Ise city, Mie prefecture, 516-8550, Japan Telephone: +81-596-36-2335 Facsimile: +81-596-36-2162 FCC ID: OPO199909010003  SHINKO ELECTRIC CO.,LTD K44-2127  Rev.0  Communication unit CMC Operation Manual  iii Revision Note #RevisionMonth/Day/YearContentsAuthor #1Rev.0 November. 2, 2000 The first editionMitsuyoshi KURODA FCC ID: OPO199909010003  SHINKO ELECTRIC CO.,LTD K44-2127  Rev.0  Communication unit CMC Operation Manual  iv Contents 1.Introduction________________________________ ________________________________________________________________ ______________________________________________________________ ____________________________________________________________ ______________________________1 11 1 1.1.Construction of the documents ________________________________ ________________________________________________________________ _____________________________________________ __________________________ _____________ 1 11 1 1.2.Application ________________________________ ________________________________________________________________ _______________________________________________________________ ______________________________________________________________ _______________________________ 1 11 1 1.3.Related Rules, Laws ________________________________ ________________________________________________________________ _______________________________________________________ ______________________________________________ _______________________ 1 11 1 1.4.Abbreviations ________________________________ ________________________________________________________________ _____________________________________________________________ __________________________________________________________ _____________________________ 1 11 1 2.Safety________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ __________________________________ ____ __2 22 2 2.1.Alert Boxes ________________________________ ________________________________________________________________ _______________________________________________________________ ______________________________________________________________ _______________________________ 2 22 2 2.1.1. General ___________________________________________________________________________ 2 2.1.2. Definitions of DANGER, WARNING and CAUTION _____________________________________ 2 2.1.3. Precautions on use _________________________________________________________________ 3 2.1.4. Storage ___________________________________________________________________________ 4 2.1.5. Installation ________________________________________________________________________ 4 2.1.6. Maintenance and Inspection _________________________________________________________ 5 3.Outline of Communication Unit CMC________________________________ ________________________________________________________________ _________________________________________ __________________ _________6 66 6 3.1.Overview ________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ _________________________________ __ _6 66 6 3.2.CMC configuration ________________________________ ________________________________________________________________ ________________________________________________________ ________________________________________________ ________________________ 6 66 6 3.3.Function of each unit ________________________________ ________________________________________________________________ ______________________________________________________ ____________________________________________ ______________________ 9 99 9 3.3.1. CMC-BC ( C ommunication M odem C ontroller B ase C ontroller) _________________________ 9 3.3.2. CMC-BM( C ommunication M odem C ontroller B ase M odem) ___________________________ 9 3.3.3. CMC-TR( C ommunication M odem C ontroller TR ansformer) ____________________________ 9 3.4.FCC standard ________________________________ ________________________________________________________________ ___…

Text truncated - open the document above for the full version.

Block Diagram

CMC-TR (Communication Modem Controller-TRansfoemer) CMC-BM (Communication Modem Controller-Base Modem) CMC-BC (Communication Modem Controller-Base Controller) BV-BM2 PCB Demodulater NBV-BC PCB TX Amp RX Amp RX filter Modulater Control logic Line driver Line receiver Indicate LED Master/Slave I/F Resonance circuit 350KHz Line receiver Line driver Serial I/F RS232C / RS485 Power Supply DC5V Power Supply DC5,P12,N12,24V Switch circuit Control logic Block diagram Power Line Reset circuit Reset circuit X'tal OSC 24MHz 300KHz +5V P12V +5V 0V N12V +24V 0V HOST Controller From 8.66KHz power supply To track Squelch Host I/F FCC ID:OPO199909010003 Max 8Port Line transciver RX transformer TX transformer CMC-BC (Slave)

Operational Description

FCC ID: OPO199909010003 11/02/00 1 K44-2128 Modifications of CMC Unit Configuration SHINKO ELECTRICTRIC CO., LTD. Research & Development Laboratory Mitsuyoshi KURODA 1. Backgrounds The communication unit CMC (Communication M odem Controller) is used for the communication between the ground Vehicle Controller and several vehicles in the conveyance system SELOHT made by Shinko Electric Co., Ltd. The communication signals are overlaid onto the power line for non-conductive power supply to the vehicles. The CMC unit is installed in the Power Supply Panel of the non conductive power supply system due to the layout conveniences. CMC as well as the vehicle (OHT) communication unit COM (COmmunication Modem) meet the requirements of FCC Part15 Subpart C. Their FCC ID’s are as follows. CMCOPO199909010001 COMOPO199909010002 Some modifications to the CMC configuration are planned to raise the communication accuracy as well as adopt the CMC units to other conveyance systems than SELOHT (e.g. OHSOHT). The modified CMC configuration will be notified for FCC Part15 Subpart C. This report describes the above modifications to the CMC configuration. 2. Current CMC configuration(Already compliant to FCC Part 15 Subpart C) Figure 1 shows the current CMC configuration. CMC consists of the following units. Printed circuit BV-BCBV-BM2 Communication transformer (transmission, reception) DC power supply (24V DC5V12V CMC overlays the signals onto the non-conductive power line. The CMC unit is located inside the Power supply panel. It modulates the signals from the Vehicle controller and sends them to the vehicles. It also demodulates the signals from the vehicles and sends them to the Vehicle controller. The communication method is FSK (frequency shift keying method). The communication frequencies in use are as follows. FromToFrequency (1)Vehicle controller Vehicles 285.7 kHz and 315.8 kHz (2)VehiclesVehicle controller 342.9 kHz and 363.6 kHz The main clock frequency used internally in the print circuit BV-BC is 24 MHz. FCC ID: OPO199909010003 11/02/00 2 K44-2128 3. Modified CMC configuration Figures 2 to 4 show the modified CMC configuration. However, the modified CMC adopts the current specifications in the digital circuits, communication method, and communication frequencies. Only the configuration is modified. FCC ID of CMC is as follows. FCC ID of CMCOPO199909010003 The major modifications are as follows. The CMC unit is located outside the Power Supply Panel. The CMC unit is divided into the following three units. ÿ CMC-BCInterface for signals from Vehicle Controller. Multiplexer between CMC and BM ÿ CMC-BMSignal modulation/demodulation between Vehicle Controller and several vehicles ÿ CMC-TRTransformers overlaying signals onto the power or signal line and picking up the signals The print circuit board BV-BC is replaced with NBV-BC. However, these two have the same digital circuits. Only the number of output ports has been changed as follows. ÿ BV-BC (current):6 output ports ÿ NBV-BC (new):8 output ports The unit now allows the user to transmit communication signals through a separate signal line instead of the current method, i.e. overlaying signals onto the non-conductive power line. Figure 2 shows the basic CMC configuration. Figure 3 shows one example of CMC configuration. In this configuration, one NBV-BC board handles the outputs to several BV-BM2 boards. Figure 4 shows another example of CMC configuration. Also in this configuration, one NBV-BC board handles the outputs to several BV-BM2 boards. The NBV-BC boards can serve either as the master or as a slave. The number of NBV-BC boards is determined by the system scale. Each separated unit of CMC (CMC-BCCMC-BMCMC-TR) are composed of the following components. CMC-BC (Communication Modem Controller Base Controller) ÿ Print circuit NBV-BC ÿ DC power supply (5V) ÿ Case CMC-BM (Communication Modem Controller Base Modem) ÿ Print circuit BV-BM2 ÿ DC power supply (24V5V12V) ÿ Case FCC ID: OPO199909010003 11/02/00 3 K44-2128 CMC-TR (Communication Modem Controller TRansformer) ÿ Communication transformer (transmission, reception) ÿ Case Vehicle Controller Power Supply Panel CMC(Communication Modem Controller) TX RX Modem CPU TX RX Vehicle Power Supply Unit Power Supply Line Parallel Wire PCB BV-BM2 PCB BV-BC Track Transformer Fig. 1 Current CMC configuration (Already compliant to FCC Part 15 Subpart C) Vehicle Controller Power Supply Panel CMC-BC Power Supply Unit Power Supply Line Parallel Wire PCB NBV-BC PCB BV-BM2 TX RX CMCBM CMC-TR Digital Signal line with shield Digital Signal line with shield Analog Signal line with shield Modem CPU TX RX Vehicle Track Fig. 2 Modified base CMC configuration FCC ID: OPO199909010003 11/02/00 4 K44-2128 Power Supply Panel CMC-BC Power Supply Unit Power Supply Line Parallel Wire CMCBM TX RX CMC-TR Digital Signal line with shield Digital Signal line with shield Analog Signal line with shield Modem CPU TX RX Vehicle Track PCB BV-BM2 CMCBM TX RX CMC-TR Digital Signal line with shield Analog Signal line with shield Output: 8-Port maximum PCB NBV-BC Vehicle Controller PCB BV-BM2 Fig. 3 Modified CMC configuration Example 1 FCC ID: OPO199909010003 11/02/00 5 K44-2128 Power Supply Panel Power Supply Unit Power Supply Line Parallel Wire Digital Signal line with shield Digital Signal line with shield Modem CPU TX RX Vehicle Track Digital Signal line with shield Output: 8-Port maximum CMC-BC PCB NBV-BC Vehicle Controller CMC-BM TX RX CMC-TR Analog Signal line with shield PCB BV-BM2 CMC-BM TX RX CMC-TR Analog Signal line with shield PCB BV-BM2 CMC-BM TX RX CMC-TR PCB BV-BM2 CMCBM TX RX CMC-TR PCB BV-BM2 CMC-BC PCB NBV-BC Output: 8-Port maximum Digital Signal line with shield Fig. 4 Modified CMC configuration Example 2

Schematics

1234 A B C D 4321 D C B A Title NumberRevisionSize A4 Date:9-Nov-2000 Sheet of File:D:\DATA\..\BVBM2.PRJDrawn By:S.SAKAKI Y37A19302 1 2 3 4 Communication Modem Controller (CMC) [BV_BM2] SHINKO ELECTRIC CO.,LTD FCC ID:OPO199909010003 1 / 10 1.0 RF BM2RAMP(2 / 10) BM2RAMP.SCH R_DATARF BM2PLL(3 / 10) BM2PLL.SCH SW RESET SWGATE SWGND BM2SW(8 / 10) BM2SW.SCH RESET BM2PWR(10 / 10) BM2PWR.SCH AHO AHS BHO BHS ALO BLO BLS ALS SWGATE SWGND BM2DRV(9 / 10) BM2DRV.SCH F_BHI F_BLI F_ALI F_AHI BHO BHS BLO BLS ALS ALO AHS AHO BM2GDRV(7 / 10) BM2GDRV.SCH SQRTRF BM2SQT(4 /10) BM2SQT.SCH FN IRES FP SWI F_BHI F_ALI F_AHI SW F_BLI RD ORES R_DATA M_RD ORES3 RESET SQRT S_RD BM2PLD(6 / 10) BM2PLD.SCH FP FN SW IRES RD ORES M_RD ORES3 S_RD BM2BCIF(5 / 10) BM2BCIF.SCH CMC [BV-BM2] Block Diagram 1234 A B C D 4321 D C B A Title NumberRevisionSize A4 Date:9-Nov-2000 Sheet of File:D:\DATA\..\BM2RAMP.SCHDrawn By:S.SAKAKI Y37A19302 1 2 3 4 Communication Modem Controller (CMC) [BV_BM2] SHINKO ELECTRIC CO.,LTD FCC ID:OPO199909010003 C1 150p C2 22p C5 22p C4 12p C7 150p RFC1 0.775mH RFC2 0.775mH AG AG CH9 PLL_IN AGAG P12A N12A CP4 0.1u CP5 0.1u AG AG CH8 IF C8 1p C9 1p CT1 3:100 1,2,3 5,6,78,9,10 12,13,14 VR2 50K VR1 5K C3 100p C6 100p 13 2 1 2 3 CH7 F_OUT 1 2 CN2 RX 1 R7 100 R8 100K R13 1K R10 100 R11 1K R9 100 R14 10K R12 1K R15 1K BVBM2_RAMP RF 1 2 CN3 RX 2 2 / 10 1.0 CP21 100u AG CP20 100u AG LP1 220uH LP2 220uH N12 P12 P12A N12A 2 3 1 8 4 IC4 AD827JN(1/2) 6 5 7 IC4 AD827JN(2/2) 3-1C 4-1C 1 2 CN7 RX 1 1 2 CN8 RX 2 1234 A B C D 4321 D C B A Title NumberRevisionSize A4 Date:9-Nov-2000 Sheet of File:D:\DATA\..\BM2PLL.SCHDrawn By:S.SAKAKI Y37A19302 1 2 3 4 Communication Modem Controller (CMC) [BV_BM2] SHINKO ELECTRIC CO.,LTD FCC ID:OPO199909010003 CH10 MOD_OUT 1 2 3 4 5 6 78 10 11 12 13 14 9 NJM2211 IC6 NJM2211 P12A P5 CP8 0.1u C10 0.1u AG AG R_DATA R17 470K R24 3.3K R16 100 R22 1M R23 1M C11 820p R_DATA BVBM2_PLL RF R19 330K R21 100K C15 0.1u C18 100p AG AG AG C16 33p C12 100p R18 15K C13 22p C17 3p VR3 5K C19 56p 13 2 C14 22p R20 10K 3 / 10 1.0 2-4C 6-1C 1234 A B C D 4321 D C B A Title NumberRevisionSize A4 Date:9-Nov-2000 Sheet of File:D:\DATA\..\BM2SQT.SCHDrawn By:S.SAKAKI Y37A19302 1 2 3 4 Communication Modem Controller (CMC) [BV_BM2] SHINKO ELECTRIC CO.,LTD FCC ID:OPO199909010003 S.SAKAKI CH201 CMP IN AGAG P12A N12A CP202 0.1u CP203 0.1u AG AG CH203 SQRT C202 220p 1.0 VR201 50K VR202 5K Y37A19302 4 / 10 1 2 3 4 1 3 2 1 2 3 R208 10K R204 10K R206 10K R203 10K R209 47K R207 4.7K R210 3.3K BVBM2_SQT SQRT D200 MA165 D201 MA165 CH200 S_IN AG P12A N12A CP200 0.1u CP201 0.1u AG AG C200 1p VR200 10K 1 2 3 R201 1K R202 12K R200 1K C201 1n R205 10K RF 2 3 7 65 1 8 4 IC202 UPC271C P12A CP204 0.1u AG N12A CP205 0.1u AG AG P12A R211 2.2K R212 3.3K R213 100k R214 3.3K P5 2 3 1 8 4 IC201 AD827JN(1/2) 6 5 7 IC201 AD827JN(2/2) 2-4C6-1C CH202 TH_L 2 3 1 8 4 IC200 AD827JN(1/2) 6 5 7 IC200 AD827JN(2/2) AG 1234 A B C D 4321 D C B A Title NumberRevisionSize A4 Date:9-Nov-2000 Sheet of File:D:\DATA\..\BM2BCIF.SCHDrawn By:S.SAKAKI Y37A19302 1 2 3 4 Communication Modem Controller (CMC) [BV_BM2] SHINKO ELECTRIC CO.,LTD FCC ID:OPO199909010003 CH3 SW CH2 FN CH1 FP DG R4 1K DG R1 1K R2 1K R3 1K 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 CN1 BCIF EN1 4 EN2 12 1A 2 1B 1 1Y 3 2A 6 2B 7 2Y 5 3A 10 3B 9 3Y 11 4A 14 4B 15 4Y 13 IC1 SN75ALS175N EN1 4 EN2 12 1A 1 1Y 2 1Z 3 2A 7 2Y 6 2Z 5 3A 9 3Y 10 3Z 11 4A 15 4Y 14 4Z 13 IC2 SN75ALS174N P5 P5 CH5 M_RD CH4 RD FP FN SW IRES RD ORES FPA FPB FNA FNB SWA SWB IRESA IRESB RDA RDB ORESA ORESB FPA FPB FNA FNB SWA SWB IRESA IRESB FPAFPB FNAFNB SWASWB IRESAIRESB RDA RDB ORESA ORESB M_RD ORES3 P5 DG CP1 0.1u CP2 0.1u 5 / 10 1.0 HOST I/F BVBM2_HSTI/F 6-1C 6-1C 6-1B 6-1B 6-1C 6-1C 6-1C 6-1C DE 3 RE 2 D 4 A 6 B 7 R 1 IC203 SN75176B DG DG P5 R215 33K R216 33K R217 3.3K R218 3.3K R219 100 1 2 3 4 5 6 7 8 9 10 CN9 MS I/F FPA FPB FNA FNB SWA SWB S_RD CH204 S_RD CP206 0.1u 6-1C 1234 A B C D 4321 D C B A Title NumberRevisionSize A4 Date:9-Nov-2000 Sheet of File:D:\DATA\..\BM2PLD.SCHDrawn By:S.SAKAKI Y37A19302 1 2 3 4 Communication Modem Controller (CMC) [BV_BM2] SHINKO ELECTRIC CO.,LTD FCC ID:OPO199909010003 DG P5 CP3 0.1u FN IRES FP SWI F_BHI F_ALI F_AHI SW F_BLI RD ORES R_DATA BVBM2_PLD M_RD ORES3 1 2 3 4 8 7 6 5 SW1 SW DIP-4 2345 1 RA1 2.2K P5 DG RESET R51 3.3K AG Q9 2SC1815 R52 10K R53 470 P5 LED1 EN 6 / 10 1.0 FN 2 F_BLI 33 F_ALI 32 F_AHI 31 SWI 44 VCC 3,15,23,35 GND 10,22,30,42 M_RD 39 F_BHI 34 BVBM2 (BVB2M.POF) IRES 43 FP 4 RD 41 ORES 40 SW 29 R_DATA 18 ORES3 38 M/S 13 EN 11 SLFC 12 RES2 14 RESET 1 ENO 27 SWOS 28 SQRT 21 S_RD 37 RD_LED 19 IC3 BM2_EPM7032 SQRT 10-4B 4-4C 3-3A 5-4C 5-4C 5-4C 5-4C 5-4B 5-4B 5-4B 5-4B 7-1C 7-1C 7-1C 7-1C 8-1C S_RD R220 3.3K AG Q10 2SC1815 R221 10K R222 470 P5 LED3 RD 5-4A 1234 A B C D 4321 D C B A Title NumberRevisionSize A4 Date:9-Nov-2000 Sheet of File:D:\DATA\..\BM2GDRV.SCHDrawn By:S.SAKAKI Y37A19302 1 2 3 4 Communication Modem Controller (CMC) [BV_BM2] SHINKO ELECTRIC CO.,LTD FCC ID:OPO199909010003 D2 ERB91-02 D1 ERB91-02 C20 0.1u C21 0.1u AG AG CP9 1u AHB 10 DIS 3 BLI 5 VCC 15 ALS 14 ALO 13 BHI 2 AHS 12 AHO 11 BHB 1 VSS 4 ALI 6 AHI 7 HDEL 8 LDEL 9 VDD 16 BLS 17 BLO 18 BHS 19 BHO 20 IC7 HIP4081AIP P12 R32 150K R25 150K F_BHI F_BLI F_ALI F_AHI BVBM2_GDRV BHO BHS BLO BLS ALS ALO AHS AHO 7 / 10 1.0 6-1C 6-1C 6-1C 6-1C 9-1C 9-1C 9-1C 9-1C 9-1B 9-1B 9-1B 9-1B 1234 A B C D 4321 D C B A Title NumberRevisionSize A4 Date:9-Nov-2000 Sheet of File:D:\DATA\..\BM2SW.SCHDrawn By:S.SAKAKI Y37A19302 1 2 3 4 Communication Modem Controller (CMC) [BV_BM2] SHINKO ELECTRIC CO.,LTD FCC ID:OPO199909010003 BVBM2_SW R30 3.3K P5 AG Q7 2SC1815 2 3 1 4 VCC 8 7 Vo 6 GND 5 PC1 TLP251 R28 330 P5 AG +Vin 1 0V 2 +Vout 6 -Vout 5 DC1 DCP010512P CP11 1u Q8 2SA1015 R26 3.3K R27 10K R31 10K CP13 0.1u CP12 1u SW RESET SWGATE SWGND R29 10K 8 / 10 1.0 R56 1.2K 6-4C 10-4B 9-3B 9-3A 1234 A B C D 4321 D C B A Title NumberRevisionSize A4 Date:9-Nov-2000 Sheet of File:D:\DATA\..\BM2DRV.SCHDrawn By:S.SAKAKI Y37A19302 1 2 3 4 Communi…

Text truncated - open the document above for the full version.

Schematics

1234 A B C D 4321 D C B A Title NumberRevisionSize A4 Date:9-Nov-2000 Sheet of File:D:\DATA\..\NBVBC.PRJDrawn By: Communication Modem Controller (CMC) [NBV_BC] S.SAKAKI SHINKO ELECTRIC CO.,LTD 1 2 3 4 FCC ID:OPO199909010003 3CX113B001200 RESET NBVLVCBCPWR NBVBCPWR.SCH 1.0 1 / 11 LED-CS LED-RS LED-TD LED-RD MASTER SLAVE RES1 RD1 RD2 232/485 RD3 RD4 RD5 RD6 RD7 RD8 FPM FNM SWM RXDS NBVBCLED NBVBCLED.SCH FPS ORS SWS FNS IR[1..8] RD[1..8] FNM ORM FPM SWM RESET SBCLK CLK FP1 FN2 FN1 FP2 SW1 OR2 OR1 SW2 IO2[1..8] IO1[1..8] TDO TDI TCLK TMS NBVPLD2 NBVPLD2.SCH TXD485 RTS485 RXD485 CTS485 485HIF 485HIF.SCH RD1 IR1 RD2 IR2 FP1 FN1 SW1 OR1 FP1 FN1 SW1 OR1 RD3 IR3 RD4 IR4 FP1 FN1 SW1 OR1 FP1 FN1 SW1 OR1 NBVBMIF1 NBVBMIF1.SCH RD5 IR5 RD6 IR6 FP2 FN2 SW2 OR2 FP2 FN2 SW2 OR2 RD7 IR7 RD8 IR8 FP2 FN2 SW2 OR2 FP2 FN2 SW2 OR2 NBVBMIF2 NBVBMIF2.SCH RXDM IR1M IR2M IR3MFPM FNM SWM ORM MS I/FM_EN NBVMIF NBVMIF.SCH RXDS IR1S IR2S IR3S FPS FNS SWS ORSMS I/F S_EN NBVSIF NBVSIF.SCH TXD232 RTS232 RXD232 CTS232 NBVBCHIF NBVBCHIF.SCH TCLK TMS RXDM IR3M IR2M LED-CS IR1M LED-RS LED-TD LED-RD MASTER SLAVE IO1[0..8] RTS485 CTS485 TXD485 RXD485 RTS232 CTS232 TXD232 RXD232 232/485 RES1 RESET RXDS IR3S IR2S IR1S SBCLK CLK IO2[1..8] TDO TDI S-EN M-EN NBVPLD1 NBVPLD1.SCH RD1 RD2 RD3 RD4 IR1 IR2 IR3 IR4 RD5 RD6 RD7 RD8 IR5 IR6 IR7 IR8 LED-RS LED-CS LED-TD LED-RD MASTER SLAVE 232/485 RES1 RD1 RD2 RD3 RD4 RD5 RD6 RD7 RD8 LED-RS LED-CS LED-TD LED-RD MASTER SLAVE 232/485 RES1 1234 A B C D 4321 D C B A Title NumberRevisionSize A4 Date:9-Nov-2000 Sheet of File:D:\DATA\..\NBVBCHIF.SCHDrawn By: Communication Modem Controller (CMC) [NBV_BC] S.SAKAKI SHINKO ELECTRIC CO.,LTD 1 2 3 4 FCC ID:OPO199909010003 3CX113B001200 CH9 TXD CH11 RXD TXD232 RTS232 RXD232 CTS232 DG P5 DG P5 CP22 0.1u DG CH10 RTS CH12 CTS 1.0 2 / 11 NBVBCHIF.SCH(HST I/F) R2OUT 20 R2IN 19 T2OUT 18 V- 17 C2- 16 C2+ 15 C2+ 11 C2- 10 T2IN 1 T1IN 2 R1OUT 3 R1IN 4 T1OUT 5 GND 6 Vcc 7 GND 9 V- 12 IC21 MAX233 1 6 2 7 3 8 4 9 5 CN12 232HST I/F 1234 A B C D 4321 D C B A Title NumberRevisionSize A4 Date:9-Nov-2000 Sheet of File:D:\DATA\..\485HIF.SCHDrawn By: Communication Modem Controller (CMC) [NBV_BC] S.SAKAKI SHINKO ELECTRIC CO.,LTD 1 2 3 4 FCC ID:OPO199909010003 3CX113B001200 P5 1 2 3 4 5 6 7 8 9 10 CN13 485HST I/F CH13 TXD CH15 RXD TXD485 RTS485 RXD485 CTS485 DG DG EN1 4 EN2 12 1A 1 1Y 2 1Z 3 2A 7 2Y 6 2Z 5 3A 9 3Y 10 3Z 11 4A 15 4Y 14 4Z 13 IC24 SN75ALS174N EN1 4 EN2 12 1A 2 1B 1 1Y 3 2A 6 2B 7 2Y 5 3A 10 3B 9 3Y 11 4A 14 4B 15 4Y 13 IC23 SN75ALS175N R5 100 R7 100 R8 100 R6 100 92345678 1 DA2 D9-1A 92345678 1 DA1 D9-1C 2345 1 RA24 10K 2345 1 RA25 10K P5P5 P5 DGDG CP25 0.1u P5 CP24 0.1u DG DG CH14 RTS CH16 CTS 1.0 3 / 11 485HIF.SCH(485HST I/F) 1234 A B C D 4321 D C B A Title NumberRevisionSize A4 Date:9-Nov-2000 Sheet of File:D:\DATA\..\NBVPLD1.SCHDrawn By: Communication Modem Controller (CMC) [NBV_BC] S.SAKAKI SHINKO ELECTRIC CO.,LTD 1 2 3 4 FCC ID:OPO199909010003 3CX113B001200 DG P5 CP1 0.1u 5V DG ST 3 D 2 F 1 VSS 4 A 5 B 6 C 7 VDD 8 X1 EXO-3C(24M) DG TCLK TMS RXDM IR3M IR2M LED-CS IR1M LED-RS LED-TD LED-RD MASTER SLAVE CP3 0.1u 1 2 3 4 8 7 6 5 SW1 DSS704 2345 1 RA1 2.2K P5 DG IO1[0..8] RTS485 CTS485 TXD485 RXD485 RTS232 CTS232 TXD232 RXD232 232/485 RES1 RESET 1.0 4 / 11 NBVPLD1.SCH(PLD1) CLK 83 I7 73 RTS485 41 M-EN 28 RXD485 44 VCC 3,13,26,38 GND 47,59,72,82 I6 74 S-EN 27 NBVBC1 (NBVBC1.POF) CTS485 45 TXD485 40 I4 76 I5 75 LED-TD 64 LED-RD 65 TXD232 49 RTS232 50 RXD232 51 CTS232 52 LED-RS 63 LED-CS 61 RES1 69 RES2 70 VCC 43,53,66,78 GND 7,19,32,42 MSET 33 SSET 34 232/485 35 SET1 36 I0 81 I1 80 I2 79 I3 77 MASTER 67 SLAVE 68 SBCLK 2 RESET 1 O2 10 O3 9 O1 11 O0 12 O6 5 O7 4 O4 8 O5 6 IR2M 21 IR3M 20 IR1M 22 RXDM 24 IR2S 16 IR3S 15 RXDS 18 IR1S 17 TCK 62 TDO 71 TMS 23 TDI 14 ECLK 37 IC1 NBVBC1 RXDS IR3S IR2S IR1S SBCLK CLK IO2[1..8] IO2-0 IO2-1 IO2-2 IO2-3 IO2-4 IO2-5 IO2-6 IO2-7 IO1-0 IO1-1 IO1-2 IO1-3 IO1-4 IO1-5 IO1-6 IO1-7 TDO TDI S-EN M-EN CH22 RXDM CH23 RXDS 5V DG ST 3 D 2 F 1 VSS 4 A 5 B 6 C 7 VDD 8 X2 EXO-3C(14.74M) DG CP27 0.1u 1234 A B C D 4321 D C B A Title NumberRevisionSize A4 Date:9-Nov-2000 Sheet of File:D:\DATA\..\NBVPLD2.SCHDrawn By: Communication Modem Controller (CMC) [NBV_BC] S.SAKAKI SHINKO ELECTRIC CO.,LTD 1 2 3 4 FCC ID:OPO199909010003 3CX113B001200 DG P5 CP2 0.1u CH3 RD3 CH4 RD4 FPS ORS SWS FNS 2345 1 RA28 2.2K DG IR[1..8] RD[1..8] FNM ORM FPM SWM CH5 RD5 CH6 RD6 CH1 RD1 CH2 RD2 RESET 1.0 5 / 11 NBVPLD2.SCH(PLD2) CH7 RD7 CH8 RD8 SBCLK CLKCLK 83 O1 80 SWS 63 O2 79 VCC 3,13,26,38 GND 47,59,72,82 FNS 64 NBVBC2 (NBVBC2.POF) O3 77 O0 81 IR1 24 IR2 22 O4 76 O5 75 O6 74 O7 73 OR2 50 SW2 52 IR5 18 IR6 17 VCC 43,53,66,78 GND 7,19,32,42 TCK 62 TDO 71 TMS 23 TDI 14 FPM 70 FNM 69 SWM 68 ORM 67 IR3 21 IR4 20 SBCLK 2 RESET 1 RD3 33 RD4 31 RD2 34 RD1 35 RD7 28 RD8 27 RD5 30 RD6 29 FP1 58 FN1 56 FPS 65 ORS 61 FN2 55 FP2 57 SW1 54 OR1 51 IR7 16 IR8 15 I7 4 I6 5 I4 8 I5 6 I0 12 I1 11 I2 10 I3 9 IC2 NBVBC2 RD1 RD2 RD3 RD4 RD5 RD6 RD7 RD8 IR1 IR2 IR3 IR4 IR5 IR6 IR7 IR8 RD1RD2RD3RD4RD5RD6RD7RD8 FP1 FN2 FN1 FP2 SW1 OR2 OR1 SW2 IO2[1..8] IO1[1..8] IO2-0 IO2-1 IO2-2 IO2-3 IO2-4 IO2-5 IO2-6 IO2-7 IO1-0 IO1-1 IO1-2 IO1-3 IO1-4 IO1-5 IO1-6 IO1-7 1 2 3 4 5 6 7 8 9 10 CN15 ISP P5 P5 CP26 0.1u TDO TDI TCLK TMS 81 1234 A B C D 4321 D C B A Title NumberRevisionSize A4 Date:9-Nov-2000 Sheet of File:D:\DATA\..\NBVBMIF1.SCHDrawn By: Communication Modem Controller (CMC) [NBV_BC] S.SAKAKI SHINKO ELECTRIC CO.,LTD 1 2 3 4 FCC ID:OPO199909010003 3CX113B001200 EN1 4 EN2 12 1A 2 1B 1 1Y 3 2A 6 2B 7 2Y 5 3A 10 3B 9 3Y 11 4A 14 4B 15 4Y 13 IC9 SN75ALS175N EN1 4 EN2 12 1A 1 1Y 2 1Z 3 2A 7 2Y 6 2Z 5 3A 9 3Y 10 3Z 11 4A 15 4Y 14 4Z 13 IC7 SN75ALS174N 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 CN1 CH1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 CN2 CH2 FP1A FP1B FN1A FN1B SW1A SW1B OR1A OR1B RD1A IR2B IR1A IR1B RD1ARD1B DG DG IR1AIR1B RD2ARD2B IR2AIR2B RD2A RD2B IR2A RD1B IR2B RD2A RD2B IR2A P5 RD1 IR1 RD2 IR2 FP1 FN1 SW1 OR1 CP8 0.1u CP9 0.1u CP10 0.1u CP11 0.1u P5 DG NBVBMIF1.SCH(BVBM I/F_1) EN1 4 EN2 12 …

Text truncated - open the document above for the full version.

Test Report

Applicant:SHINKO ELECTRIC CO., LTD. Type of Equipment:CMC (CMCBC, CMCBM, CMCTR) Model No.:CMC (CMCBC, CMCBM, CMCTR) Test standard:FCC Part 15 Subpart C Test Result:Complies This report may not be reproduced in full, partial reproduction may only be made with the written consent of the laboratory. The results in this report apply only to the sample tested. Date of test: October 20, 2000 Tested by: Hiroya Tabata Approve d by: Issued date: October 31, 2000 Kazutoyo Nakanishi Section Manager of EMC section •• Testing Laboratory A-pex International Co., Ltd. Telephone:int +81 596 39 1485 108 Yokowa-cho, Ise-shi, Mie-ken 516-1106 JAPANFacsimile:int +81 596 39 0232 EMISSION TEST REPORT Test Report No. : 21CE0032-YW-1 Test report No. : 21CE0032-YW-1 Page: 2 of 13 Issued date: October 31, 2000 Testing Laboratory A-pex International Co., Ltd. Telephone:+81 596 39 1485 108 Yokowa-cho, Ise-shi, Mie-ken, 516-1106 JAPANFacsimile:+81 596 39 0232 Table of Contents Page 1 GENERAL INFORMATION3 1.1 Product Description4 1.2 Tested System Details4 1.3 Tested Methodology4 1.4 Test Facility4 2 SYSTEM TEST CONFIGURATION5 2. 1 Operation Environment 5 2.2 Justification5 2. 3 EUT Exercise Software5 2.4 Test Procedure5 Figure 2.1 Configuration of Tested System6 3 RADIATED MEASUREMENT PHOTOS7 Figure 3.1 Radiated Measurement Photos7 4 RADIATED EMISSION DATA9 4.1 Field Strength Calculation10 5 TEST EQUIPMENT USED11 APPENDIX12 Test Data A1 – A4 Test report No. : 21CE0032-YW-1 Page: 3 of 13 Issued date: October 31, 2000 Testing Laboratory A-pex International Co., Ltd. Telephone:+81 596 39 1485 108 Yokowa-cho, Ise-shi, Mie-ken, 516-1106 JAPANFacsimile:+81 596 39 0232 1 GENERAL INFORMATION APPLICANT: SHINKO ELECTRIC CO., LTD. TRADE NAME: SHINKO ADDRESS: 100 Takegahana-cho, Ise-shi, Mie-ken 516-8550 Japan Tel: +81-596-36-3180 Fax: +81-596-36-3974 REGULATION(S): FCC Part 15 Subpart C MODEL NUMBER: CMC (CMCBC, CMCBM, CMCTR) SERIAL NUMBER: - KIND OF EQUIPMENT: CMC (CMCBC, CMCBM, CMCTR) TESTED DATE: October 20, 2000 RECEIPT DATE OF SAMPLE: October 20, 2000 TEST REPORT NUMBER: 21CE0032-YW-1 TEST SITE: A-PEX Yokowa NO. 2 Open Test Site Test report No. : 21CE0032-YW-1 Page: 4 of 13 Issued date: October 31, 2000 Testing Laboratory A-pex International Co., Ltd. Telephone:+81 596 39 1485 108 Yokowa-cho, Ise-shi, Mie-ken, 516-1106 JAPANFacsimile:+81 596 39 0232 1.1 Product Description Model: CMC (CMCBC, CMCBM, CMCTR), reffered to as the EUT in this report, is a communication between vehicles and the ground side vehicle controller, that is realized by power line communication. About 300kHz-350kHz signals are superposed on the power line of non-contact power supply or communication line. The clock frequency used in the EUT is 24 MHz. (Printed circuit board: NBV-BC) Power Supply: DC 24V, 5V, ± 12V FSK modulation (285.7kHz, 315.8kHz) 1.2 Tested System Details The FCC IDs for all equipment, plus description of all cables used in the tested system are: Model DoC or FCC ID Description Cable description Backshe ll Mate rial (1) SHINKON/ACMCBCShielded Interconnection CableP.V.C. M/N: CMCBC (EUT) (2) SHINKON/ACMCBMShielded Interconnection CableP.V.C. M/N: CMCBM (EUT) (3) SHINKON/A CMCTRShielded Interconnection CableP.V.C. M/N: CMCTR (EUT) (4) SHINKON/AHOSTShielded Interconnection CableP.V.C. (Vehicle Controller) (5) TAKASAGON/ADC Power SupplyShielded DC Power CableP.V.C. M/N:GPT322 (DC5V) S/N:30290006 (6) KIKUSUIN/ADC Power SupplyShielded DC Power CableP.V.C. M/N:PAB25-1TR (DC24V) S/N:30081818 (7) TAKASAGON/ADC Power SupplyShielded DC Power CableP.V.C M/N:GPT601 (DC ± 12V) S/N:25183147 1.3 Tested Methodology Radiated testing were performed according to the procedures in FCC/ANSI C63.4 (1992). 1.4 Test Facility The open area test site and conducted measurement facility used to collect the radiated data is located on 108 Yokowa-cho, Ise-shi, Mie-ken 516-1106 Japan. This site has been fully described in a report submitted to FCC office, and listed on May 15, 2000(Registration number: 90411). 2 SYSTEM TEST CONFIGURATION Test report No. : 21CE0032-YW-1 Page: 5 of 13 Issued date: October 31, 2000 Testing Laboratory A-pex International Co., Ltd. Telephone:+81 596 39 1485 108 Yokowa-cho, Ise-shi, Mie-ken, 516-1106 JAPANFacsimile:+81 596 39 0232 2.1 Operation Environment Temperature : 21 • Humidity: 78% Power supply : DC 24V, 5V, ± 12V 2.2 Justification The system was configured in typical fashion (as a customer would normally use it) for testing. 2.3 EUT Exercise Software The EUT exercise program used during radiated testing was designed to exercise the various system components in a manner similar to typical use. The sequence is used: Operation Mode : Communication Communication between vehicle and vehicle controller is realized by power line communication. About 300kHz – 350kHz signals are superposed on the power line. 2.4 Test Procedure Tabletop Equipment Radiated Emissions EUT was placed on a platform of nominal size, 1m by 1.5m, raised 80cm above the conducting ground plane. Test was made with the antenna positioned in both the horizontal and vertical planes of polarization. The measurement antenna was varied in height above the conducting ground plane to obtain the maximum signal strength. The measurement distance was 3m. Test report No. : 21CE0032-YW-1 Page: 6 of 13 Issued date: October 31, 2000 Testing Laboratory A-pex International Co., Ltd. Telephone:+81 596 39 1485 108 Yokowa-cho, Ise-shi, Mie-ken, 516-1106 JAPANFacsimile:+81 596 39 0232 Figure2.1 Configurat…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Hiroshi Fujii(General Manager, Quality Assurance Dept.)
[email protected]81-596-36-4600Fax: 81-596-36-4328

Technical Contact

A-PEX International Co., Ltd.Hidekazu Takata
[email protected]81454501515

1-1-32 Shinurashima-cho · Yokohama-city, Kanagawa pref. · Japan

Non-Technical Contact

A-pex International Co., Ltd.Akemi Aikawa
[email protected]81454501515

Test Firm

UL Japan, Inc.Kazunori Nishimura
[email protected]81-596-24-6717Fax: 82-596-24-8020

Technical Specifications

#Rule PartsFrequency RangePower OutputTolerance
2-0.3158 MHz - 0.3158 MHz20.00 mW100 ppm

Other Applications from Shinko Electric Co Ltd

OHT Vehicle - FCC ID OPOSSOHT300VHTCOM - Shinko Electric Co Ltd
OPOSSOHT300VHTCOM

OHT Vehicle

May 26, 2002

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
OPO199909010002

DCD - Part 15 Low Power Transmitter Below 1705 kHz

Feb 22, 2000

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Communication Modem Controller - FCC ID OPO199909010001 - Shinko Electric Co Ltd
OPO199909010001

Communication Modem Controller

Dec 09, 1999

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz