FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. PAC International Limited/
  3. OQL-P-CNC

OQL-P-CNCNetwork controller with low range proximity reader

PAC International Limited
Network controller with low range proximity reader - FCC ID OQL-P-CNC - PAC International Limited
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Jan 09, 2003
Application Purpose
Original Equipment
Date of Application
Jan 09, 2003
Equipment Note
Network controller with low range proximity reader
Frequency Range
0.15360000 - 0.15360000
Company
PAC International Limited
Country
United Kingdom

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Installation Guide January 200315162 Ver 2.8 DRAFT E PAC Portico Portico, 1 Lower Ragsdale Drive, Building 3, Suite 800, Monterey, California 93940 USA www.PACPortico.com This document is correct at the time of going to press. However, as part of our ongoing product enhancement program we reserve the right to make changes to the product and/or literature at any time without prior notice. Central Network Controller Copyright and Protective Notices 1. The copyright of this document and the associated drawings is the property of PAC Portico (Blick USA, Inc.), and is issued on condition that it is not copied, reprinted or reproduced, nor its contents disclosed, either wholly or in part, without the consent in writing of, or in accordance with the conditions of a contract with of PAC Portico (Blick USA, Inc.). 2. The publication of information in this document does not imply freedom from patent or other protective rights of PAC Portico (Blick USA, Inc.), or others. 3. Performance figures and data quoted in this document are typical, and must be specifically confirmed by of PAC Portico (Blick USA, Inc.) before they become applicable to any tender, order or contract. Training and Technical Support Training courses covering the installation and use of all PAC Portico products are regularly held at Blick USA in Monterey California. It is strongly recommended that any persons installing or programming PAC Portico products attend a suitable training course beforehand. Technical Support for all PAC Portico products is available during normal office hours. This service is provided primarily for the use of trained installers. End users of PAC Portico products should first contact their installation or maintenance company before contacting PAC Portico. Literature. If you have any comments on this or any other PAC Portico literature, then you can either write to ‘Technical Writing’ at the address below or you can email us at: manuals@PAC Portico.com 15162 Ver 2.8 DRAFT ECentral Network Controller Installation Guide Page 2© 2002 Blick USA, Inc. IMPORTANT: When installing the PAC Portico equipment the following should be noted: HEALTH AND SAFETY Installation must wired in accordance with National Wiring Regulations (BS7671, IEE National Wiring Regulations in the UK). Failure to do so can result in injury or death by electric shock. It must also comply with any local Fire, Health and Safety regulations. A secured door that may be part of an escape route from an area must be installed with: •A Fail-Safe lock (A). So that the door will be released if the power fails. Ideally a magnetic lock should be used as these are less likely to jam or seize. •A normally-closed Break-Glass or Manual Pull (B) in the lock supply wiring. So that in an emergency the fail-safe lock can be immediately depowered. B A The controller must be connected to Earth Ground. Isolate the controller supply before working on the controller. CABLING The cabling used in the PAC Portico access control systems (six wire bus, reader cables, etc.) are not prone to electrical interference. However, you should avoid routing cable close to heavy load switching cables and equipment. If this is unavoidable then cross the cable at right angles every 1- 2m (3 to 6 ft) to reduce the interference. RFID Devices As similar RFID technology is now widely used in a number of other industries, for example automotive immobilisers, it is possible that interaction between your access control credential and other devices may cause one or the other to function incorrectly. Should you suspect that you have experienced such a problem the solution is to separate your access control credential from other RFID devices. FCC Notice This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. KeyPAC CNCFCC ID OQL-PAC-CNC PAC CNCFCC ID OQL-P-CNC Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Central Network Controller Installation Guide15162 Ver 2.8 DRAFT E © 2002 Blick USA, Inc.Page 3 Table of Contents HEALTH AND SAFETY ............................................................................................................. 2 CABLING ................................................................................................................................... 2 RFID Devices............................................................................................................................. 2 FCC Notice ................................................................................................................................ 2 Table of Figures ........................................................................................................................... 4 Abbreviations Used in this Document ...................................................................................... 5 1. About this Document .............................................................................................................. 6 1.1 MKI and MKII CNC Hardware .........................................…

Text truncated - open the document above for the full version.

Cover Letter(s)

Covering letter for FCC Form 731 Attachments 0.459 Request that submitted material be withheld from Public Inspection FCC ID OQL-P-CNC It is requested that the following exhibits be withheld from Public Inspection: • Operational Description • Schematic Diagram • Block Diagram This information is considered to be PAC International proprietary and confidential. This unit is believed to have a commercial advantage over our competition – revealing details of the design to our competitors would put us at a disadvantage. We therefore request that the above-listed items are withheld from public inspection. Shaun Byrne Principal Engineer PAC International Ltd

External Photos

EXTERNAL PHOTOS

ID Label/Location Info

IDENTIFICATION LABELS The labels below are fitted as shown in the photo. The unit is marketed under the model numbers 6100-CNC, K6100-CNC, 25542, 20542, 25511, 21511, 21511/2, 21512, 21512/2, 21513, 21513/2, 21514 and 21514/2. The labels are made of polycarbonate. The adhesive is 3M468 (or equivalent). The label quality and adhesion satisfies UL requirements. WARNING! ATTENTION! ACHTUNG! 651/2 Access System Unit Also suitable for use as Misc. Signal Appliance For Canada and Access Control Unit for US 72SK Control 1463/3 INTERNATIONAL LTD US LISTEDC Disconnect the main AC power before removing this cover. Voltage: 13.8VDC Current: 450mA MAX Model No. 6100-CNC Multi Site FCC ID: OQL-P-CNC This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. WARNING INTERNATIONAL LTD FIX BARCODE HERE X DATE CODE Made in UK1640/1 LABEL LOCATIONS

Internal Photos

INTERNAL PHOTOS

Test Report

Page 1 of 15 Member of the SGS Group (Société Générale de Surveillance) Registered in England No. 1193985. Registered Office: Inward Way, Rossmore Business Park, Ellesmere Port, Cheshire, CH65 3EN. SGS United Kingdom Ltd. International Electrical Approvals abc South Industrial Estate Bowburn Co. Durham DH6 5AD United Kingdom Tel: +44 (0) 191 377 2000 Fax: +44 (0) 191 377 2020 email: [email protected] Electromagnetic Compatibility Test of: Central Network Controller (CNC), including power supply Model Number: 25511 (Central Network Controller), Model no. not supplied for Power Supply Applicant: PAC International Ltd Test Type: Compliance Test Specification: Test Result: FCC CFR47, parts 15.107/15.207, 15.109 and 15.209. Complied SGS Serial Number: DUR 24097.1/EMC/LS/02 Date of Receipt: 20 th May 2002 Date of Test(s): 27 th May 2002 – 29 th May 2002 Date of Issue: 10 th January 2003 Issue Number: 3 This report refers only to the sample submitted for test. This report shall not be reproduced except in full without the written approval of the testing laboratory. Test EngineerAuthorised Signatory L.SteelA. Reynard Technical Manager abc TEST REPORT Page 2 of 15 Issue Date:10 th January 2003 SGS Serial Number:DUR24097.1/EMC/LS/02 Issue Number: 3 CONTENTSPage Number 1. Client Information ........................................................................................................................... 3 2. Details Of Test Laboratory............................................................................................................. 3 3. Equipment Under Test (EUT) ........................................................................................................ 4 3.1 Identification Of EUT...................................................................................................................................................... 4 4. Test Specification, Methods and Procedures ............................................................................. 5 4.1 Test Specification(s) ...................................................................................................................................................... 5 4.2 Purpose Of Test............................................................................................................................................................. 5 4.3 Methods and Procedures............................................................................................................................................... 5 5. Deviations or Exclusions from the Test Specifications ............................................................. 6 6. Operation of the EUT During Testing / Configuration and Peripherals .................................... 6 6.1 Operation of EUT during testing. ................................................................................................................................... 6 6.2 Configuration and Peripherals ........................................................................................................................................ 6 7. Test Results .................................................................................................................................... 7 7.1 General Comments........................................................................................................................................................ 7 7.2 Modifications Made to the EUT...................................................................................................................................... 7 7.3 Summary of Test Results .............................................................................................................................................. 7 7.4Conducted Emissions Test Results – 15.107/15.207 ............................................................. 8 7.5Radiated Emissions Test Results – 15.109.......................................................................... 12 7.6Radiated Emissions Test Results – 15.209.......................................................................... 14 abc TEST REPORT Page 3 of 15 Issue Date:10 th January 2003 SGS Serial Number:DUR24097.1/EMC/LS/02 Issue Number: 3 1. Client Information Company Name: PAC International Ltd Address: 1 Park Gate Close, Bredbury, Stockport, SK6 2SZ. Contact Person: Shaun Byrne Telephone: 0161 406 3400 Facsimile: 0161 430 8658 2. Details Of Test Laboratory Company Name: SGS International Electrical Approvals UKAS Accreditation Number: 1116 Address: South Industrial Estate, Bowburn, Co. Durham, DH6 5AD. Contact Persons: Mr Alan Reynard Telephone: 0191 377 2000 Facsimile: 0191 377 2020 abc TEST REPORT Page 4 of 15 Issue Date:10 th January 2003 SGS Serial Number:DUR24097.1/EMC/LS/02 Issue Number: 3 3. Equipment Under Test (EUT) 3.1Identification Of EUT Model Number: 25511 (Central Network Controller / CNC), Model no. not supplied for Power Supply Unique Identifier: 1984493 (CNC), 1984493 (Power Supply) Description of EUT: Central Network Controller, including Power Supply Internal Clock Frequencies: (Maximum) 32 MHz – CNC <108 MHz (Power Supply) Supply Voltage: 120v ac, 60 Hz Classification: Intentional and Unintentional Radiator (CNC), Unintentional Radiator (Power Supply) Accessories Supplied: None abc TEST REPORT Page 5 of 15 Issue Date:10 th January 2003 SGS Serial Number:DUR24097.1/EMC/LS/02 Issue Number: 3 4. Test Specification, Methods and Procedures 4.1Test Specification(s) Specification(s)Title FCC CFR 47 : October 1999 Parts 15.107/15.207, 15.109 and 15.209 Code Of Federal Regulations 4.2Purpose Of Test To perform the relevant tests and assess the product for compliance with the above specification. 4.3Methods and Procedures The standards listed on the previous page refer to the following tests: - CFR 47 ClauseTest 15.107/15.207Conducted Emissions (Intentional and Unintentional Radiator) 15.109 (30-1000 MHz) Radiated Emissions (Intentional and …

Text truncated - open the document above for the full version.

Test Setup Photos

abc TEST REPORT Page 10 of 14 Issue Date:28th November 2002 SGS Serial Number:DUR24097.1/EMC/LS/02 Issue Number: 1 Conducted Emissions Test Configuration Conducted Emissions Environmental Conditions Power Supply (to controller) 120V, 60Hz Temperature 19.5°C Relative Humidity 52% Barometric Pressure 1001mb Conducted Emissions Measurement Uncertainties Frequency ± 200kHz Amplitude ± 3.0dB The uncertainties stated are calculated in accordance with the requirements of UKAS with a confidence level of 95%. Test Equipment Used Equipment TypeModel Number LISN (50Ω) Thurlby Thandar TTi 1600 Chase ReceiverLHR7000 SoftwareVersion 6.00b SGS Screened Room- Spectrum AnalyserHP8563E Check Equip.PLC 1C abc TEST REPORT Page 12 of 14 Issue Date:28 th November 02 SGS Serial Number:DUR24097.1/EMC/LS/02 Issue Number: 1 Radiated Emissions Test Configuration Radiated Emissions Environmental Conditions Power Supply (to controller) 120V AC, 60Hz Temperature 9°C Relative Humidity 67% Barometric Pressure 986mb Radiated Emissions Measurement Uncertainties Frequency ± 200kHz Amplitude ± 4.6dB The uncertainties stated are calculated in accordance with the requirements of UKAS with a confidence level of 95%. Test Equipment Used Equipment TypeModel Number Receiver SystemHP 8573B Biconical AntennaEMCO 3110 Log Periodic AntennaEMCO 3146 Pre-amplifierZHL 1042J Check Equip.York CNE III SoftwareOpen Site HP85879 abc TEST REPORT Page 14 of 14 Issue Date:28 th November 02 SGS Serial Number:DUR24097.1/EMC/LS/02 Issue Number: 1 Radiated Emissions Test Configuration Radiated Emissions Environmental Conditions Power Supply (to controller) 120V AC, 60Hz Temperature 9.5°C Relative Humidity 63% Barometric Pressure 982mb Radiated Emissions Measurement Uncertainties Frequency ± 200kHz Amplitude ± 4.6dB The uncertainties stated are calculated in accordance with the requirements of UKAS with a confidence level of 95%. Test Equipment Used Equipment TypeModel Number Loop AntennaEMCO 6502 Spectrum AnalyserHP8563E

Contact Information

Applicant

Shaun C Byrne(Controller Team Leader)
[email protected]+44 161 4063440Fax: +44 161 430 8658

Technical Contact

PAC INTERNATIONAL LTDMike Cook
[email protected]44 161 4063400

1 PARK GATE CLOSE, BREDBURY · STOCKPORT, CHESHIRE · United Kingdom

Non-Technical Contact

PAC INTERNATIONAL LTDRobert W Harvey
[email protected]44 161 4063400

Test Firm

SGS United Kingdom Ltd.Stephen Thompson
[email protected]44-0-191-377-2000Fax: 44-0-191-377-2020

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.1536 MHz - 0.1536 MHz-
Confidentiality
Long Term

Other Applications from PAC International Limited

Panel LF Reader GS3 OneProx - FCC ID OQLGS3LFP - PAC International Limited
OQLGS3LFP

Panel LF Reader GS3 OneProx

Aug 01, 2013

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Standard LF Reader GS3 OneProx - FCC ID OQLGS3LFS - PAC International Limited
OQLGS3LFS

Standard LF Reader GS3 OneProx

Aug 01, 2013

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Vandal LF Reader GS3 OneProx - FCC ID OQLGS3LFV - PAC International Limited
OQLGS3LFV

Vandal LF Reader GS3 OneProx

Aug 01, 2013

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Admin MT Reader GS3 OneProx - FCC ID OQLGS3MTA - PAC International Limited
OQLGS3MTA

Admin MT Reader GS3 OneProx

Jul 31, 2013

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
PIN MT Reader GS3 OneProx - FCC ID OQLGS3PIN - PAC International Limited
OQLGS3PIN

PIN MT Reader GS3 OneProx

Jul 30, 2013

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter