FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. PAC International Limited/
  3. OQL-PAC-D-DT

OQL-PAC-D-DTLow range proximity reader

PAC International Limited
Low range proximity reader - FCC ID OQL-PAC-D-DT - PAC International Limited
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
May 06, 2001
Application Purpose
Original Equipment
Date of Application
Dec 13, 2000
Equipment Note
Low range proximity reader
Frequency Range
0.13330000 - 0.13330000
Company
PAC International Limited
Country
United Kingdom

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

INTERNATIONAL Data Sheet November 200017384 DRAFT 20462, 20453 DualTech Desktop Reader Installation Instructions Description The DualTech PC Desktop Reader is an accessory for use with a PAC Adminstration interface unit. This system is used for direct PC to controller communications (fig. 1). Note: This Desktop Reader will read KeyPAC and PAC ID-devices. Note: It is unlikely that you will need an Interface Kit at a PC that already has a CNC attached. CNCs have either front panel or external readers for administration purposes. WARNING: The Interface Unit contains mains voltages. This procedure should only be carried out by a suitably qualified and experienced person. If you have any doubts as to your suitability contact PAC for advice. Failure to do so may result in injury or death by electric shock. WARNING: If, at any time, the interface kit or its wiring appear damaged then immediately disconnect it from the mains and contact PAC for advice. Failure to do so can result in electric shock and/or further damage to equipment. DualTech Desktop Reader17384 DRAFT Page 3 DRAFT ©2000 PAC International Ltd. Installation Opening the Interface Unit WARNING: This Interface Unit contains mains voltages. Before opening ensure that it is disconnected from the mains. Failure to do so can result in injury or death by electric shock. Make sure that the Interface Unit is not connected to the mains then remove the lid by removing the 4 screws recessed in the base. There are removable terminal blocks fitted to the circuit board as shown below: Connecting the Desktop reader The Desktop reader supplied with the kit is complete with cable and terminal block. Fit the terminal block with the screw heads facing the centre of the interface unit, and route the cable through the grommet provided. Wiring for provided cables - for information only DualTech Desktop Reader17384 DRAFT Page 4 DRAFT ©2000 PAC International Ltd. Desktop Reader to Interface 56 inch cable supplied. PC InterfaceDesktop Reader 4-pole Terminal BlockDesktop reader -V ———— -VGreen VCA ———— VCA Yellow SIG ———— SIGWhite +V ———— +VBrown Specification Dimensions 5.12in x 3.54in x 1.25in Voltage 10.5v DC to 20v DC (Supplied by Administration Interface Unit) Current Less than 85mA Temperature Operating: -10°C to +55°C (14°F to 130°F) Storage:-30°C to +80°C (-20°F to 175°F) Humidity Operating: 0-90% RH at 30°C ±2°C (85°F±5°F) for 24 hours Reading Range KeyPAC: Up to 4 inches PAC: Up to 2 inches Lead Length 56 inches This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC ID OQL-PAC-D-DT

Cover Letter(s)

Covering letter for FCC Form 731 Attachments 0.459 Request that submitted material be withheld from Public Inspection FCC ID OQL-PAC-D-DTConfirmation number EA99514 It is requested that the following exhibits be withheld from Public Inspection: • Operational Description • Schematic Diagram • Block Diagram This information is considered to be PAC International proprietary and confidential. The unit is supplied fully encapsulated in hard potting - the design features are not evident from inspection hence reverse engineering is extremely problematic. This unit is believed to have a performance advantage over our competition – revealing details of the design to our competitors would put us at a disadvantage. We therefore request that the above-listed items are withheld from public inspection. Shaun Byr ne Controller Team Leader PAC International Ltd

External Photos

Exhibit 2: External Photos ©2000 PAC1 2. External Photos Rear View Exhibit 2: External Photos ©2000 PAC2 Front View

ID Label/Location Info

Exhibit 1: ID Label and Location Information ©2000 PAC1 1. Labels The labels below are fitted to the rear of the unit The model number is written in block capitals using a permanent pen next to the ‘Model No.:’ text. The model number is 20462.

Internal Photos

Exhibit 8: Internal Photos ©2000 PAC1 8. Internal Photos PCB Assembly (Component Side) Exhibit 8: Internal Photos ©2000 PAC2 PCB Assembly (Solder side)

Test Report

Page 1 of 19 Member of the SGS Group (Société Générale de Surveillance) Registered in England No. 1193985. Registered Office: SGS Hous e, 217-221 London Road, Camberley, Surrey, GU15 3EY SGS United Kingdom Ltd. EMC Services αβχ South Industrial Estate Bowburn Co. Durham DH6 5AD United Kingdom Telephone: +44 (0) 191 377 2000 Fax: +44 (0) 191 377 2020 [email protected] Electromagnetic Compatibility Test Report Test of: Desktop Dual-Tech Reader Model Number: 20462 Applicant: PAC International LTD Test Type: Compliance Test Specification: FCC CFR47, parts 15.109 for unintentional radiators, parts 15.207 and 15.209 for Intentional Radiators. SGS Serial Number: DUR22522B/EMC/LS/00 Date of Receipt: 12 th September 2000 Date of Test(s): 20 th to 29 th September 2000 Date of Issue: 3 rd October 2000 Issue Number: 1 Test EngineerAuthorised Signatory L. SteelA. H. Reynard αβχ TEST REPORT Page 2 of 19 Issue Date: 3 rd October 2000 SGS Serial Number: DUR22522B/EMC/LS/00 Issue Number: 1 αβχ TEST REPORT Page 3 of 19 Issue Date: 3 rd October 2000 SGS Serial Number: DUR22522B/EMC/LS/00 Issue Number: 1 CONTENTS Page Number 1. Client Information.................................................................................................................. 4 2. Details Of Test Laboratory ....................................................................................................4 3. Equipment Under Test (EUT)................................................................................................. 5 3.1Identification Of EUT..................................................................................................................5 4. Test Specification, Methods and Procedures........................................................................ 5 4.1Test Specification(s)..................................................................................................................5 4.2Purpose Of Test .........................................................................................................................5 4.3Methods and Procedures..........................................................................................................6 5. Deviations or Exclusions from the Test Specifications ......................................................... 7 6. Support Equipment............................................................................................................... 8 7. Operation of the EUT During Testing / Configuration and Peripherals................................ 11 7.1Operation of EUT during testing. ...........................................................................................11 7.2Configuration and Peripherals ...............................................................................................11 8. Test Results ........................................................................................................................ 12 8.1General Comments .................................................................................................................12 8.2Modifications Made to the EUT...............................................................................................12 8.3 Summary of Test Results .......................................................................................................13 8.4Radiated Emissions Test Results- Unintentional Radiator .................................................14 8.5AC Power Line Conducted Emissions Test Results ...........................................................16 8.6Radiated Emissions Test Results- Intentional Radiator......................................................19 αβχ TEST REPORT Page 4 of 19 Issue Date: 3 rd October 2000 SGS Serial Number: DUR22522B/EMC/LS/00 Issue Number: 1 1. Client Information Company Name: PAC International LTD. Address :1 Park Gate Close, Bredbury, Stockport, SK6 2SZ, United Kingdom. Contact Person: Mr Shaun Byrne Telephone: +44 161 406 3400 Facsimile: +44 161 430 8658 2. Details Of Test Laboratory Company Name: SGS EMC Services LTD. UKAS Accreditation Number: 1116 Address :Unit 10, Bow burn South Industrial Estate, Bow burn, County Durham, DH6 5AD, United Kingdom. Contact Persons: Mr Alan Reynard / Mr Fred Huggins Telephone: +44 191 377 2000 Facsimile: +44 191 377 2020 αβχ TEST REPORT Page 5 of 19 Issue Date: 3 rd October 2000 SGS Serial Number: DUR22522B/EMC/LS/00 Issue Number: 1 3. Equipment Under Test (EUT) 3.1Identification Of EUT Model Number: 20462 Unique Identifier: Unique Identifier Not Supplied Description of EUT: The EUT is an R.F. card entry reader, designed to prevent access to restricted areas by unauthorised persons. Fundamental (Carrier) Frequency 133 kHz Single Channel Internal Clock Frequencies: 16 MHz Supply Voltage: 18V DC (Via central controller) Classification: Intentional radiator, incorporating digital device. Environment Class: Commercial / Class A Ports present: One port comprising six wires. Refer to configuration/peripherals section of this report for details. Accessories Supplied: Central Controller (refer to section 6 for full details) 4. Test Specification, Methods and Procedures 4.1Test Specification(s) Specification(s)Title FCC CFR 47 : October 1999 Parts 15.109, 15.207 and 15.209 Code Of Federal Regulations ANSI C63.4 : 1992 American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9kHz to 40GHz. 4.2Purpose Of Test To perform the relevant tests and assess the product for compliance with the above specification (s), so that the manufacturer (PAC International Limited) can verify compliance with the specified limits. αβχ TEST REPORT Page 6 of 19 Issue Date: 3 rd October 2000 SGS Serial Number: DUR22522B/EMC/LS/00 Issue Number: 1 4.3Methods and Procedures The standards listed on the previous page refer to the following tests: CFR 47 ClauseTest 15.109 Radiated Emissions (Unintentio…

Text truncated - open the document above for the full version.

Test Report

Derivation of Field Strengths 1. For the detection method peak measurements were taken. 2. Actual readings and corrections: |-----------+-----------+-----------+-----------+-----------+-----------| |Frequency |Peak |Antenna |Field at 3 |Correction |Corrected | |kHz |Spectrum |Factor K |m |factor to |field | | |Analyser | |E dBuV/m |convert |strength | | |Reading | | |from 3m to |for 300m | | |dBuV | | |300m |dBuV/m | | |V | | Note 1 | Note 2 | | |-----------+-----------+-----------+-----------+-----------+-----------| |133.502 |87.00 |-41.3 |97.2 |-80 |17.2 | |-----------+-----------+-----------+-----------+-----------+-----------| |400.71 |45.00 |-41.4 |55.1 |-80 |-24.9 | |-----------+-----------+-----------+-----------+-----------+-----------| |534 |38 |-41.5 |48 |-80 |-32 | |-----------+-----------+-----------+-----------+-----------+-----------| |667 |44 |-41.5 |54 |-80 |-26 | |-----------+-----------+-----------+-----------+-----------+-----------| |934 |45 |-41.5 |55 |-80 |-25 | |-----------+-----------+-----------+-----------+-----------+-----------| |1068 |42 |-41.5 |52 |-80 |-28 | |-----------+-----------+-----------+-----------+-----------+-----------| |1201 |40 |-41.5 |50 |-80 |-30 | |-----------+-----------+-----------+-----------+-----------+-----------| Note 1: Formula used to obtain field E at 3 m E (dBuV/m) = V (dBuV) + K (dB S/m) + 51.5 This formula is taken from the National Physical Laboratory calibration report for the antenna (copied on the following page). Note 2: The correction factor of –80dB to convert from field measured at 3m to field at 300m is taken from 47 CFR 15.31 f (2) (page 661, 10-1-99 edition) which states that an inverse linear distance extrapolation factor of 40dB/decade can be used. There are 2 decades of distance from 3m to 300m, therefore the extrapolation factor is –2x40 = -80dB

Test Setup Photos

Exhibit 6: Test Setup Photos ©2000 PAC1 6. Test Setup Photos. Please refer to pages 14, 16 and18 of the test report exhibit 'fccreport.doc'

Contact Information

Applicant

Shaun C Byrne(Controller Team Leader)
[email protected]+44 161 4063440Fax: +44 161 430 8658

Technical Contact

PAC International LimitedShaun C Byrne
[email protected]+44 161 406 3400

1 Park Gate Close · Stockport, Cheshire · United Kingdom

Non-Technical Contact

PAC International LimitedShaun C Byrne
[email protected]++44 161 406 3400

Test Firm

SGS United Kingdom Ltd.Stephen Thompson
[email protected]44-0-191-377-2000Fax: 44-0-191-377-2020

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.1333 MHz - 0.1333 MHz-
Confidentiality
Long Term

Other Applications from PAC International Limited

Panel LF Reader GS3 OneProx - FCC ID OQLGS3LFP - PAC International Limited
OQLGS3LFP

Panel LF Reader GS3 OneProx

Aug 01, 2013

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Standard LF Reader GS3 OneProx - FCC ID OQLGS3LFS - PAC International Limited
OQLGS3LFS

Standard LF Reader GS3 OneProx

Aug 01, 2013

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Vandal LF Reader GS3 OneProx - FCC ID OQLGS3LFV - PAC International Limited
OQLGS3LFV

Vandal LF Reader GS3 OneProx

Aug 01, 2013

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Admin MT Reader GS3 OneProx - FCC ID OQLGS3MTA - PAC International Limited
OQLGS3MTA

Admin MT Reader GS3 OneProx

Jul 31, 2013

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
PIN MT Reader GS3 OneProx - FCC ID OQLGS3PIN - PAC International Limited
OQLGS3PIN

PIN MT Reader GS3 OneProx

Jul 30, 2013

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter