
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Portable Beacon System Normal Usage 1. Install the Light Posts along the desired route using the Hook & Loop Tape provided. 2. The maximum distance between each Light Post is approximately 300 feet(90 meters), based on an unobstructed view. Recommended to posting higher up on the tree trunk. 3. Remember to switch the Light Posts on before setting to desire positions. 4. Press the“On” button on key Fob, the Light Posts in range will light up 5. Light Posts will remain on for 10 minutes once activated without further FOB control input 6. Light Posts can be turned off manually at any time with the“Off” button on Key Fob and remain ready for signal receiving. 7. The “PULSE” button located on the Key FOB will transmit the signal every 1 minute for 40 minutes and then turn off. 8. After 40 minutes the last signal is sent, Light Posts will remain on for 10 minutes and then turn off light. The “PULSE” button allows a user to walk along the route activating lights without the need to continuously press the “On” button to activate the Light Posts. 9. Light Posts can be turned off manually at any time with “Off” button on Key Fob. Learning Mode While the Light Post is switched on. Function and Responses in the following situations: 1. Press and hold Program Button for 3 seconds on the Light Post then the device will enter the Learning Mode; Indication: the Light Posts will flash 3 times (rapid flashing), and then keep light on for 10 seconds 2. During the 10 seconds the Light Post is on, press the “On” button on the Key Fob while in range of the Light Post and the signal will be recorded a. If the signal is recevied: the Light Post LEDs will flash 3 times b. If no signals are detected in 10 seconds the light Post turns off and is back to normal (ready) status c. Light Post “OFF” Button is pressed The device will be switched off, user has to switch it on again to operate 3. Once procedure (2a) is completed properly, the Light Post will be able to work with the registered Key Fob. FCC STATEMENT 1. This device complies with Part 15 or the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. 2. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Swiss Tech Acquisitions, LLC June 27, 2013 To: SIEMIC, INC. 775 Montague Expressway Milpitas , CA 95035 USA Dear Sir/Madam, Re: Project and Product Certification Representative Authorization Letter We , Swiss Tech Acquisitions, LLC hereby authorize SIEMIC, INC. to act as a Certification Body for certifying for the following project(s): Product Description: Portable Beacon System Model name: 50125R FCC ID: ORH50125R We affirm that between SIEMIC and Swiss Tech Acquisitions, LLC , any difference in understanding, including test plan, measurement methods, applicable standards and relevant procedures and processes have been resolved prior to commencement of testing activities. Sincerely, Client’s signature: Client’s name / title: Bennett Rubin / Vice President Contact information / address: 30725 Solon Industrial Parkway, Solon, Ohio, United States, 44139
SCS-F19: Confidentiality Request Letter Page 1 of 1 Rev 2.0 Swiss Tech Acquisitions, LLC June 27, 2013 To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD Confidentiality Request regarding application for certification of FCC ID: ORH50125R We hereby request confidential treatment of information accompanying this application as outlined below: - Block Diagram - Operational Description - Schematic The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 & 0.459 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Client’s signature: Client’s name / title: Bennett Rubin / Vice President Contact information / address: 30725 Solon Industrial Parkway, Solon, Ohio, United States, 44139
FCC Certification label location Sample Label location
FCC Certification label Sample FCC ID: ORH50125R This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
Antenna
FCC ID: ORH50125R ACCURATE TECHNOLOGY CO., LTD REPORT NO.: ATE20131230 APPLICATION CERTIFICATION On Behalf of Swiss Tech Acquisitions, LLC Portable Beacon System Model No.: 50125R FCC ID: ORH50125R Prepared for : Swiss Tech Acquisitions, LLC Address : 30725 Solon Industrial Parkway, Solon, Ohio, United States, 44139 Prepared by : Accurate Technology Co., Ltd. Address : F1, Bldg. A&D, Changyuan New Material Port, Keyuan Rd., Science & Industry Park, Nanshan District, Shenzhen 518057, P.R. China Tel: +86-755-26503290 Fax: +86-755-26503396 Report No. : ATE20131230 Date of Test : June 18, 2013 Date of Report : June 26, 2013 FCC ID: ORH50125R ACCURATE TECHNOLOGY CO., LTD REPORT NO.: ATE20131230 TABLE OF CONTENTS Description Page Test Report 1. TEST RESULTS SUMMARY................................................................................................... 4 2. GENERAL INFORMATION...................................................................................................... 5 2.1. Description of Device (EUT)..........................................................................................................5 2.2. Description of Test Facility.............................................................................................................6 2.3. Measurement Uncertainty..............................................................................................................6 3. MEASURING DEVICE AND TEST EQUIPMENT................................................................ 7 3.1. For Radiated Emission Measurement..........................................................................................7 4. RADIATED EMISSION MEASUREMENT............................................................................. 8 4.1. Block Diagram of Test.....................................................................................................................8 4.2. Radiated Emission Limit (Class B)................................................................................................9 4.3. EUT Configuration on Test.............................................................................................................9 4.4. Operating Condition of EUT...........................................................................................................9 4.5. Test Procedure.................................................................................................................................9 4.6. The Field Strength of Radiation Emission.................................................................................10 5. ANTENNA REQUIREMENT ................................................................................................. 11 5.1. The Requirement ..............................................................................................................................11 5.2. Antenna Construction.......................................................................................................................11 FCC ID: ORH50125R ACCURATE TECHNOLOGY CO., LTD REPORT NO.: ATE20131230 Test Report Certification Applicant : Swiss Tech Acquisitions, LLC Manufacturer : Provide Ltd. EUT Description : Portable Beacon System (A) MODEL NO.: 50125R (B) SERIAL NO.: N/A (C) POWER SUPPLY: DC 6V (lithium battery 3V×2) Measurement Procedure Used: FCC Rules and Regulations Part 15 Subpart B Class B ANSI C63.4: 2009 The device described above is tested by Accurate Technology Co., Ltd. to determine the maximum emission levels emanating from the device. The maximum emission levels are compared to the FCC Part 15 Subpart B Class B limits both radiated and conducted emissions. The measurement results are contained in this test report and Accurate Technology Co., Ltd. is assumed full responsibility for the accuracy and completeness of these measurements. Also, this report shows that the Equipment Under Test (EUT) is to be technically compliant with the FCC requirements. This report applies to above tested sample only. This report shall not be reproduced in part without written approval of Accurate Technology Co., Ltd. Date of Test : June 18, 2013 Prepared by : (Kelly Cheng, Engineer ) Approved & Authorized Signer : (Sean Liu, Manager) FCC ID: ORH50125R ACCURATE TECHNOLOGY CO., LTD REPORT NO.: ATE20131230 1. TEST RESULTS SUMMARY Test Items Test Standard Test Results Power Line Conducted Emission FCC Part 15 Subpart B N/A Radiated Emission FCC Part 15 Subpart B Pass Remark: “N/A” means “Not applicable” FCC ID: ORH50125R ACCURATE TECHNOLOGY CO., LTD REPORT NO.: ATE20131230 2. GENERAL INFORMATION 2.1.Description of Device (EUT) EUT : Portable Beacon System Model Number : 50125R Power Supply : DC 6V (lithium battery 3V×2) Operation Frequency : 315MHz Trade Name : Applicant : Swiss Tech Acquisitions, LLC Address : 30725 Solon Industrial Parkway, Solon, Ohio, United States, 44139 Manufacturer : Provide Ltd. Address : 3D, Florida Mansion, 9-11 Cleveland Street, Causeway Bay, Hong Kong Date of sample received : June 13, 2013 Date of Test : June 18, 2013 FCC ID: ORH50125R ACCURATE TECHNOLOGY CO., LTD REPORT NO.: ATE20131230 2.2.Description of Test Facility EMC Lab : Accredited by TUV Rheinland Shenzhen Listed by FCC The Registration Number is 253065 Listed by FCC The Registration Number is 752051 Listed by Industry Canada The Registration Number is 5077A-1 Listed by Industry Canada The Registration Number is 5077A-2 Accredited by China National Accreditation Committee for Laboratories The Certificate Registration Number is L3193 Name of Firm : Accurate Technology Co., Ltd. Site Location : F1, Bldg. A&D, Changyuan New Material Port, Keyuan Rd. Science & Industry Park, Nanshan District, Shenzhen 518057, P.R. China 2.3.Measurement Uncertainty Conducted Emission Expanded Uncertainty = 2.23dB, k=2 Power Disturbance Expanded Uncertainty = 2.92 dB, k=2 Radiated emission expanded uncertainty (9kHz-30MHz) = 3.08dB, k=2 Radiated emission expanded uncertainty (30MHz-1…
Text truncated - open the document above for the full version.
Radiated emissions test 30MHz- 1GHz Radiated emissions test > 1GHz
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | 315 MHz - 315 MHz | - |

Personal Recorder
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
Personal Recorder
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Portable Beacon System
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Talking Dog Collar
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
Talking Dog Collar
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter