FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Guangdong Transtek Medical Electronics Co.,Ltd/
  3. OU9-TMB2287B

OU9-TMB2287BBlood pressure monitor

Guangdong Transtek Medical Electronics Co.,Ltd
Blood pressure monitor - FCC ID OU9-TMB2287B - Guangdong Transtek Medical Electronics Co.,Ltd
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Oct 15, 2023
Application Purpose
Original Equipment
Date of Application
Oct 15, 2023
Equipment Note
Blood pressure monitor
Frequency Range
2402.00000000 - 2480.00000000
Company
Guangdong Transtek Medical Electronics Co.,Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

User Manual Blood Pressure Monitor Model:TMB-2287-B Arm Type Thank you very much for selecting TRANSTEK Blood Pressure Monit or TMB-2287-B.Please do read the user manual carefully and thoroughtly so as to ensure the safe usage of this product, and keep the manual well for fu rther reference in case you have problems. Guangdong Transtek Medical Electronics Co., Ltd.Zone A, No.105 ,Dongli Road, Torch Development District, 528437 Zhongshan,Guangdong,China TIME / DATE P ul / min M EM O R Y Version:A/0 INTRODUCTION................................................... ............................................................... 2 General DescriptionIndications for UseMeasurement Principle Receiving and Inspecting your MonitorSafety InformationLCD Display SignalMonitor ComponentsList BEFORE YOU START............................................... ...........................................................8 Choice of Power SupplyInstalling and Replacing the BatteriesSetting Date and TimePair a smart device with the monitorSetting a user ID MEASUREMENT.................................................... ............................................................15 Applying the cuffStart the Measurement DATA MANAGEMENT................................................ ........................................................19 Recall the RecordsDelete the Records INFORMATION FOR USER........................................... ....................................................22 Tips for measurementMaintenances ABOUT BLOOD PRESSURE........................................... ..................................................24 What are systolic pressure and diastolic pressure?What is the standard blood pressure classification?Irregular pulse rate detectorWhy does my blood pressure fluctuate throughout the day?Why do I get a different blood pressure at home compared to the hospital? Is the result the same if measuring on the right arm? TROUBLESHOOTING................................................ .......................................................26 SPECIFICATIONS................................................. .............................................................27 AUTHORIZED COMPONENT .......................................... .................................................28 CONTACT INFORMATION............................................ .....................................................28 EMC GUIDANCE................................................... .............................................................29 FCC STATEMENT.................................................. .............................................................33  Table of Contents CATALOGUE   Thank you for selecting TRANSTEK blood pressure Monitor (TM B-2287-B). The monitor features blood pressure measurement, pulse rate mea surement and the result storage. The warranty period is two years. Readings taken by the TMB-2287-B are equivalent to those ob tained by a trained observer using the cuff and stethoscope auscultation me thod. This manual contains important safety and care information, and provides step by step instructions for using the product. Read the manual thoroughly before using the product. Features: Maximum 199 records per user General Description Measuring-during-inflation technology 60.5 mm×92.5 mm Digital LCD display INTRODUCTION INTRODUCTION Safety Information The signs below might be in the user manual, labeling or other component. They are the requirement of standard and using. Indications for Use Measurement Principle This product uses the Oscillometric Measuring method to det ect blood pressure. Before every measurement, the unit establishes a “zero pressure ” equivalent to the airpressure. Then it starts inflating the arm cuff, meanwhile, the unit detects pressure oscillations generated by beat-to-beat pulsatile, which is used to determine the systolic and diastolic pressure, and also pulse rate. This Blood Pressure Monitor is a digital monitor intended f or use in measuring blood pressure and pulse rate with arm circumference ranging fr om FPWRFP DERXWôÝòÝ FPWRFP DERXWôÝòÝ FPWRFP DERXWôÝôÝ RUFPWRFP DERXWôÝòÝ  It is intended for adult indoor use only. Check that the device packaging has not been tampered with and make sure that all contents are present. Before use, ensure that there is no visible damage to the device or accessories and that all packaging material ha s been removed. If you have any doubts, do not use the device and contact your retailer or the specified Customer Services address. Receiving and Inspecting your Monitor MR UnsafeTo identify an item which poses unacceptable risks to the patie nt, medical staff or other persons within the MR environment. Manufacturer Serial Number Type BF applied part Direct Current The symbol indicates that the product should not be discarded as unsorted waste but must be sent to separate collection facilities for recovery and recycling. Recyclable CautionIndicates that caution is necessary when operating the device o r control close to where the symbol is placed, or that the curren t situation needs operator awareness or operator action in order to avoid undesirable consequences. Refer to instruction manual/bookletTo signify that the instruction manual/ booklet must be read.Note: The background color of the symbol is blue Date of manufacture For indoor use only Class II Equipment Consult instructions for use or consult electronic instructions for use Batch code   INTRODUCTION INTRODUCTION Precaution * This device is intended for indoor, home use and is not inten ded for self-use in public areas. * This device is portable, but it is not intended for use durin g patient transport. * This device is not suitable for continuous monitoring during medical emergencies or operations. * This device is intended for non-invasive measuring and monito ring of arterial blood pressure. It…

Text truncated - open the document above for the full version.

Attestation Statements

ApplicantDeclaration QSF27-14-04Rev1.0Rev.Feb6,2023Page 1 of 1 OriginalIssue:Jan.4,2021 SGSNorthAmericaInc. 620OldPeachtreeRoad SUITE100 Suwanee,Georgia30024 UnitedStates ApplicantLegalBusinessName GuangdongTranstekMedicalElectronicsCo.,Ltd Address ZoneA,No.105,DongliRoadTorchDevelopmentDistrictZhongshan,Guangdong,528437, China GranteeCode OU9 FCCID OU9-TMB2287B AuthorizedContactName JerryFan ContactEmail [email protected] ContactPhone +86-760-85166220 I,theundersigned,certifythatIamanauthorizedsignatoryfortheApplicantandthereforedeclare; a)inaccordancewith47CFR2.911(d),allofthestatementshereinandtheexhibitsattachedheretoaretrueandcorrecttothebestofmy knowledgeandbelief. b)inacceptingaGrantofEquipmentAuthorizationissuedbyaTCB,undertheauthorityoftheFCC,asaresultoftherepresentationsmadein thisapplication,theApplicantisresponsiblefor: (1)labelingtheequipmentwiththeexactFCCIDasspecifiedinthisapplication, (2)compliancestatementlabelingpursuanttotheapplicablerules, (3)complianceoftheequipmentwiththeapplicabletechnicalrules, c)iftheApplicantisnottheactualmanufactureroftheequipment,appropriatearrangementshavebeenmadewiththemanufacturertoensure thatproductionunitsofthisequipmentwillcontinuetocomplywiththeFCC’stechnicalrequirements. d)inaccordancewith47CFR2.909andKDB394321,theApplicanthasread,understoodandagreestoacceptthattheyaretheresponsible partyandagreetoabidebytheirresponsibilitiesasspecifiedunder47CFR2.909andKDB394321. e)inaccordancewithISO17065,FCCKDB641163,FCCKDB610077,KDB394321andRSP-100,theApplicanthasread,understood,accepts andagreestoabidebythepostmarketsurveillancerequirements. (1)theApplicantunderstands,acceptsandagreesthatasamplemayberequestedforsurveillancetesting. (2)theApplicantshallmakeprovisionstoalwayshaveaproductionsampleavailableuponrequestbySGS,FCCand/orISED. (3)theApplicantshall,uponrequestbySGS,attheApplicant’sexpense,provideaproductionsampleoftherequestedproducttoSGS, FCCand/orISEDasinstructed.Thesampleshallincludeallsupportdevices,cables,software,accessoriesorotherhardwareor softwarerequiredforevaluation,review,certificationandauditsurveillanceofproductscertifiedbySGS. f)neithertheApplicantnoranypartytotheapplicationissubjecttoadenialofFederalbenefits,thatincludesFCCbenefits,pursuanttoSection 5301oftheAnti-DrugAbuseActof1988,21U.S.C.§862becauseofaconvictionforpossessionordistributionofacontrolledsubstance.See 47CFR1.2002(b)forthedefinitionofa“party”forthesepurposes. g)theApplicanthasread,understood,acceptsandagreestoabidebytheSGSNorthAmerica,Inc.(TCB)termsandconditions. LinktoCFRs:https://www.fcc.gov/wireless/bureau-divisions/technologies-systems-and-innovation-division/rules-regulations-title-47 LinktoKDBs:https://apps.fcc.gov/oetcf/kdb/index.cfm LinktoRSP-100:https://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf01130.html LinktotheCoveredList:CoveredList [GuangdongTranstekMedicalElectronicsCo.,Ltd](“theapplicant”)certifiesthattheequipmentforwhichauthorizationissoughtisnot “covered”equipmentprohibitedfromreceivinganequipmentauthorizationpursuanttosection2.903oftheFCCrules. [GuangdongTranstekMedicalElectronicsCo.,Ltd](“theapplicant”)certifiesthat,asofthedateofthefilingoftheapplication,the applicant[isnot]identifiedontheCoveredlist,establishedpursuantto§1.50002,asanentityproducing“covered”equipment. ApplicantSignature: Date:2023/09/05 PrintName: JerryFan Title: RAManager *NOTE:ThisdeclarationcannotbesignedbyanAgent,itshallbesignedbyanauthorizedpersonlistedintheFCCdatabase

Attestation Statements

UNITED STATES DESIGNATED AGENT LETTER Date: 20230905 TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Applicant U.S. designated agent Company Name: Guangdong Transtek Medical Electronics Co.,Ltd Company Name: MIO LABS INC. Grantee Code: OU9 FRN: Contact Name: 0032569972 Chengcen Su Contact Name: Jerry Fan Address: 4500 Great America Pkwy Suite 1023 Address: Zone A, No.105 ,Dongli Road Torch Development District City/Province/Zip: 95054 City/Province/Zip: Zhongshan , Guangdong/528437 Telephone: 157 286 6685 ext. 28(301- 910-0529) Telephone: +86-760-85166220 Fax: / Fax: +86-760-86742877 Email: [email protected] Email: [email protected] Applicable Equipment: FCC ID: <OU9-TMB2287B> ATTN: Director of Certification: We, < Guangdong Transtek Medical Electronics Co.,Ltd > and <MIO LABS INC.> understand and acknowledge the applicants consent and the designated agent’s obligation to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and e- mail of the designated agent listed above. We, < Guangdong Transtek Medical Electronics Co.,Ltd > and <MIO LABS INC.> acknowledge the applicant’s acceptance of its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. Applicant U.S. designated agent Name (Printed): Jerry Fan Name (Printed):Chengcen Su Title: RA Manager Title:Sales Manager Signature: Signature:

Cover Letter(s)

GuangdongTranstekMedicalElectronicsCo.,Ltd Date:2023/09/05 TO:FederalCommunicationCommission EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MID21046 Regarding:FCCID:OU9-TMB2287B Towhomitmayconcern: We,theundersigned,herebyauthorizeSGS-CSTCStandardsTechnicalServicesCo.,Ltd.toactonour behalfinallmannersrelatingtoapplicationforequipmentauthorizationwithrespecttotheFCCIDabove, includingsigningofalldocumentsrelatingtothesematters.Anyandallactscarriedoutbytheagenton ourbehalfshallhavethesameeffectasactsofourown. We,theundersigned,herebycertifythatwearenotsubjecttoadenialoffederalbenefits,thatincludes FCCbenefits,pursuanttoSection5301oftheAnti-DrugAbuseActof1988,21U.S.C.853(a). Whereouragentsignstheapplicationforcertificationonourbehalf,Iacknowledgethatallresponsibility forcomplyingwiththetermsandconditionsforCertification,asspecifiedbySGSNorthAmerica,Inc.,still resideswithGuangdongTranstekMedicalElectronicsCo.,Ltd. Thisauthorizationisvaliduntilfurtherwrittennoticefromtheapplicant. Sincerely, PrintName:JerryFanTitle:RAManager Signature: OnbehalfofCompany:GuangdongTranstekMedicalElectronicsCo.,Ltd Telephone:+86-760-85166220 E-mail:[email protected]

Cover Letter(s)

GuangdongTranstekMedicalElectronicsCo.,Ltd TO:FederalCommunicationCommission EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MID21046 Regarding:ConfidentialityRequestregardingapplicationforFCCID:OU9-TMB2287B LONGTERMCONFIDENTIALITY Pursuantto47CFRSection0.459and0.457ofthecommission’srules,theapplicantherebyrequest confidentialtreatmentofthedocumentslistedbelow,associatedwiththecertificationapplication referencedabove. Schematic(s) BlockDiagrams OperationalDescriptions Thedocumentsabovecontainproprietaryinformationnotreleasedtothepublic.Publicdisclosureofthis informationmayproveharmfultothebusinessoftheapplicant. SHORTTERMCONFIDENTIALITY Additionally,theapplicantrequeststhefollowingdocumentsbeheldconfidentialuntilthedeviceis marketedor180daysfromthegrantdate,whicheverisless.Ifthedeviceismarketedwithin aforementioneddaysoftheGrantDate,theapplicantwillnotifytheTCBperFCCKDB726920D01 ConfidentialityRequestProcedures. ExternalPhotos InternalPhotos TestSetupPhotos Usermanual(s) Sincerely, PrintName:JerryFanTitle:RAManager Signature: OnbehalfofCompany:GuangdongTranstekMedicalElectronicsCo.,Ltd Telephone:+86-760-85166220 E-mail:[email protected]

External Photos

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A02 Rev.A/0 Page: 1 of 7 Appendix External Photos for SZCR2308002788ME FCC ID: OU9-TMB2287B SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A02 Rev.A/0 Page: 2 of 7 EUT Constructional Details (EUT Photos) Model No.: TMB-2287-B Label Location SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A02 Rev.A/0 Page: 3 of 7 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A02 Rev.A/0 Page: 4 of 7 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A02 Rev.A/0 Page: 5 of 7 Model No.: TMB-2287-BK Label Location SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A02 Rev.A/0 Page: 6 of 7 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A02 Rev.A/0 Page: 7 of 7 - End of the Appendix -

ID Label/Location Info

Dimension:50X15mm,Thickness:0.05mm label TMB-2287-B Colour:黑色+Pantone Reflex Blue C+底877c Material:adhesive label with water proof 材质:60#珠光特制胶水+光胶 SN:2EB1267230300001--2EB1267230300050 TMB-2287-B Model IP Classification: IP21 Rating: 4×AAA batteries, 6V AC adaptor powered mode: 5V 1AOptional! (Please use the AC adaptor which authorized by the manufacturer!) Guangdong Transtek Medical Electronics Co., Ltd. Zone A, No.105 ,Dongli Road, Torch Development District, 528437 Zhongshan,Guangdong,China 2023-03 SN (21)2EB1267230300001 (01)XXXXXXXXXXXXXX GS1 Datamatrix (UDI) MADE IN CHINA PO#2BEB1267 FCC ID: OU9-TMB2287B

Internal Photos

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A03 Rev.A/0 Page: 1 of 5 Appendix Internal Photos for SZCR2308002788ME FCC ID: OU9-TMB2287B SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A03 Rev.A/0 Page: 2 of 5 EUT Constructional Details (EUT Photos) Model No.: TMB-2287-B Antenna SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A03 Rev.A/0 Page: 3 of 5 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A03 Rev.A/0 Page: 4 of 5 Model No.: TMB-2287-BK Antenna SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A03 Rev.A/0 Page: 5 of 5 - End of the Appendix -

RF Exposure Info

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230800278803 Page: 1 of 10 Keny Xu EMC Laboratory Manager 1 Cover page RF Exposure Report Application No.: SZCR2308002788ME Applicant: Guangdong Transtek Medical Electronics Co., Ltd. Address of Applicant: Zone A, No.105, Dongli Road, Torch Development District, 528437 Zhongshan, Guangdong, China Manufacturer: Guangdong Transtek Medical Electronics Co., Ltd. Address of Manufacturer: Zone A, No.105, Dongli Road, Torch Development District, 528437 Zhongshan, Guangdong, China Factory: Guangdong Transtek Medical Electronics Co., Ltd. Address of Factory: Zone A, No.105, Dongli Road, Torch Development District, 528437 Zhongshan, Guangdong, China Equipment Under Test (EUT): EUT Name: Blood pressure monitor Model No.: TMB-2287-BK, TMB-2287-B   Please refer to section 4.2 of this report which indicates which model was actually tested and which were electrically identical. FCC ID: OU9-TMB2287B Standards: FCC Rules 47 CFR §2.1093 KDB 447498 D04 interim General RF Exposure Guidance v01 Date of Receipt: 2023-08-30 Date of Test: 2023-09-01 to 2023-09-12 Date of Issue: 2023-09-15 Test Result : Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230800278803 Page: 2 of 10 2 Version Revision Record Version Chapter Date Modifier Remark 01 2023-09-15 Original Authorized for issue by: Edison Li/Project Engineer Eric Fu/Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230800278803 Page: 3 of 10 3 Contents Page 1 COVER PAGE ........................................................................................................................................ 1 2 VERSION ................................................................................................................................................ 2 3 CONTENTS ............................................................................................................................................ 3 4 GENERAL INFORMATION ..................................................................................................................... 4 4.1 GENERAL DESCRIPTION OF E.U.T. ...................................................................................................... 4 4.2 DETAILS OF EUT ............................................................................................................................... 4 4.3 SEPARATION DISTANCE...................................................................................................................... 5 4.4 TEST LOCATION ................................................................................................................................ 6 4.5 TEST FACILITY .................................................................................................................................. 6 4.6 DEVIATION FROM STANDARDS ............................................................................................................ 6 4.7 ABNORMALITIES FROM STANDARD CONDITIONS .................................................................................... 6 4.8 OTHER INFORMATION REQUESTED BY THE CUSTOMER .......................................................................... 6 5 FCC RADIOFREQUENCY RADIATION EXPOSURE LIMITS .................................................................. 7 5.1 BLANKET 1 MW BLANKET EXEMPTION.................................................................................................. 7 5.2 MPE-BASED EXEMPTION.................................................................................................................... 7 5.3 SAR-BASED EXEMPTION .................................................................................................................... 8 6 MEASUREMENT AND CALCULATION ................................................................................................ 10 6.1 MAXIMUM TRANSMIT POWER ............................................................................................................. 10 6.2 RF EXPOSURE CALCULATION ........................................................................................................... 10 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230800278803 Page: 4 of 10 4 General Information 4.1 General Description of E.U.T. Product Type: Portable device Mobile device Fixed device 4.2 Details of EUT Power supply: TMB-2287-B AC Adapter Model: BLJ06L050100U-U Input: AC 100-240V, 50/60Hz, 0.2A max Output: DC 5.0V, 1.0A DC 6V(4*AAA batteries) TMB-2287-BK DC 6V(4*AAA batteries) Operation Frequency: 2402MHz to 2480MHz Bluetooth Version: V5.0 Modulation Type: GFSK Number of Channels: 40 Channel Spacing: 2MHz Antenna Type: PCB Antenna Antenna Gain: 0.27dBi Remark:The information in this section is provided by the applicant or manufacturer, SGS is not liable to the accuracy, suitability, reliability or/and integrity of the information. Remark: Model No.: TMB-2287-BK, TMB-2287-B Only the model TMB-2287-B was tested, since according to the declaration from the applicant, the electrical circuit design, layout, components used, internal wiring and functions were identical for all the above models, with only difference on model No., power supply, shape of enclosure and software. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230800278803 Page: 5 of 10 4.3 Separation Distance Minimum test separation distance: 5mm Remark: This minimum test separation distance is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions …

Text truncated - open the document above for the full version.

Test Report

Antenna Specification Product Name: TMB-2287-BK, TMB-2287-B Issue Date: 2023.6.28 Content 1.General Information 1.1 General information of testing institutions 1.2 Test equipment 1.3 Test environment 1.4 Statement 2.Sample Information 2.1 Client information 2.2 Description of EUT(S) 2.3 EUT appearance 2.4 DUT setup photo of free space OTA testing 3.Test Result 3.1 Test standard 3.2 Test uncertainty 3.3 Test data 3.3.1 S1l parameters 3.3.2 VSWR 3.3.3 Typical free space efficiency and gain 3.3.4 Typical free space radiation patter 1. General Information 1. 1 General information of testing institutions Name Shenzhen DBT Communication Device Co., Ltd Address Rm505, 8th building, Yungu 2nd period, pingshan No.1 Road, Xili Town,Nanshan District, ShenZhen , China Tel 0755-83763273 E- mail [email protected] Equipment 1. RayZone 1800 2. Keysight E5071C 1.3 Test environment Temperature 25. 0*C Humidity 59%RH Pressure 100.12kPa 1.4 Statement (1) The test results in the report are only applicable to the tested samples and the tested samples work under the environment described in the report (2) Any objection to this report shall be raised 30 days after formal confirmation of the report. (3) The report is invalid without the signature of the auditor and approver. 2.Sample Information 2.1 Client information Name Guangdong Transtek Medical Electronics Co., Ltd. Address Zone A, No. 105 , Dong Li Road, Torch Development District, zhongShan, Guangdong, China 2.2 Description of EUT(S) Product Name 2.4 GHz Antenna Antenna Size 13.5*7.5mm Antenna Type PCB Test Item VSWR; Gain; Efficiency; Radiation pattern Frequency Range 2402- 2480MHz Received Date 2023.8.25 Test Date 2023.8.25 Remark 2.3 EUT appearance See test report 2.4 DUT setup photo of free space OTA testing Zenith is at Theta » 0° 3.Test Results 3.1 Test standard Name Parameter Method Standard no. Mobile Communication antenna VSWR Generic specification for antennas used in the mobile communications GB/T 9410-2008 Antenna gain Radiation pattern Antenna Radiation efficiency IEEE Standard Test Procedures for Antennas ANSI/IEEE Std 149-1979 3.2 Test uncertainty The uncertainty was calculated on the basis of the GUM published by ISO.using the inclusion factor of K=2 and the 95% confidence level to express the extended uncertainty. Item Uncertainty VSWR ±0.3 Antenna gain + ldB Radiation efficiency ±10% 3.3 Test data 3.3.1 S1l parameters 3.3.2 V SWR Frequency/MHz 2400 2450 2500 VSWR 1.4975 1.6486 2.2626 3.3.3 Typical free space efficiency and gain Frequency MHz 2400 2410 2420 2430 2440 2450 2460 2470 2480 2490 2500 Peak Gain dBi 0.27 0.02 -0.38 -0.05 -0.4 0.02 -0.6 -0.28 -0.34 -0.75 -0.6 Efficiency % 46.29 45.54 42.95 46.76 43.21 46.53 41.35 46.14 46.96 45.04 47.86 3.3.4 Typical free space radiation p atter

Test Report

SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230800278802 Page: 1 of 59 Keny Xu EMC Laboratory Manager TEST REPORT Application No.: SZCR2308002788ME Applicant: Guangdong Transtek Medical Electronics Co., Ltd. Address of Applicant: Zone A, No.105, Dongli Road, Torch Development District, 528437 Zhongshan, Guangdong, China Manufacturer: Guangdong Transtek Medical Electronics Co., Ltd. Address of Manufacturer: Zone A, No.105, Dongli Road, Torch Development District, 528437 Zhongshan, Guangdong, China Factory: Guangdong Transtek Medical Electronics Co., Ltd. Address of Factory: Zone A, No.105, Dongli Road, Torch Development District, 528437 Zhongshan, Guangdong, China Equipment Under Test (EUT): EUT Name: Blood pressure monitor Model No.: TMB-2287-BK, TMB-2287-B   Please refer to section 2 of this report which indicates which model was actually tested and which were electrically identical. FCC ID: OU9-TMB2287B Standard(s) : 47 CFR Part 15, Subpart C 15.247 Date of Receipt: 2023-08-30 Date of Test: 2023-09-01 to 2023-09-12 Date of Issue: 2023-09-15 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230800278802 Page: 2 of 59 Revision Record Version Chapter Date Modifier Remark 01 2023-09-15 Original Authorized for issue by: Edison Li/Project Engineer Eric Fu/Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230800278802 Page: 3 of 59 2 Test Summary Radio Spectrum Technical Requirement Item Standard Method Requirement Result Antenna Requirement 47 CFR Part 15, Subpart C 15.247 N/A 47 CFR Part 15, Subpart C 15.203 & 15.247(b)(4) Pass Radio Spectrum Matter Part Item Standard Method Requirement Result Conducted Emissions at AC Power Line (150kHz-30MHz) 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 6.2 47 CFR Part 15, Subpart C 15.207 Pass Conducted Peak Output Power ANSI C63.10 (2013) Section 11.9.1 47 CFR Part 15, Subpart C 15.247(b)(3) Pass Minimum 6dB Bandwidth ANSI C63.10 (2013) Section 11.8.1 47 CFR Part 15, Subpart C 15.247a(2) Pass Power Spectrum Density ANSI C63.10 (2013) Section 11.10.2 47 CFR Part 15, Subpart C 15.247(e) Pass Conducted Band Edges Measurement ANSI C63.10 (2013) Section 11.13.3.2 47 CFR Part 15, Subpart C 15.247(d) Pass Conducted Spurious Emissions ANSI C63.10 (2013) Section 11.11 47 CFR Part 15, Subpart C 15.247(d) Pass Radiated Emissions which fall in the restricted bands ANSI C63.10 (2013) Section 6.10.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions Below 1GHz ANSI C63.10 (2013) Section 6.4,6.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions Above 1GHz ANSI C63.10 (2013) Section 6.6 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Remark: Model No.: TMB-2287-BK, TMB-2287-B Only the model TMB-2287-B was tested, since according to the declaration from the applicant, the electrical circuit design, layout, components used, internal wiring and functions were identical for all the above models, with only difference on model No., power supply, shape of enclosure and software. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230800278802 Page: 4 of 59 3 Contents Page 1 Cover Page ......................................................................................................................................... 1 2 Test Summary ..................................................................................................................................... 3 3 Contents ............................................................................................................................................. 4 4 General Information............................................................................................................................ 6 4.1 Details of E.U.T. ........................................................................................................................... 6 4.2 Description of Support Units ......................................................................................................... 6 4.3 Measurement Uncertainty ............................................................................................................ 7 4.4 Test Location ............................................................................................................................... 8 4.5 Test Facility .................................................................................................................................. 8 4.6 Deviation from Standards ............................................................................................................. 8 4.7 Abnormalities from Standard Conditions ....................................................................................... 8 5 Equipment List ................................................................................................................................... 9 6 Radio Spectrum Technical Requirement ..........................................................................................11 6.1 Antenna Requirement ........................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Jerry Fan(RA Manager)
[email protected]+86-760-85166220Fax: +86-760-86742877

Technical Contact

SGS-CSTC Standards Technical Services Co., Ltd.Keny Xu
[email protected]+8675525328629

No.1 Workshop, M-10, Middle Section, · Shenzhen · China

Non-Technical Contact

SGS-CSTC Standards Technical Services Co., Ltd.Keny Xu
[email protected]+8675525328629

Test Firm

SGS-CSTC Standards Technical Services Co., Ltd. ShKeny Xu
[email protected]+86 (0)755 2532 8629

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz700.00 µW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted.

Other Applications from Guangdong Transtek Medical Electronics Co.,Ltd

OU9SFX66AA01

Body Fat Scale

Aug 24, 2026

Equipment Class

PCB - PCS Licensed Transmitter
OU9BB2284-AE01

Blood Pressure monitor

Sep 02, 2024

Equipment Class

DTS - Digital Transmission System
Blood Pressure monitor - FCC ID OU9BB-1597-G - Guangdong Transtek Medical Electronics Co.,Ltd
OU9BB-1597-G

Blood Pressure monitor

Aug 08, 2024

Equipment Class

PCB - PCS Licensed Transmitter
Blood pressure monitor - FCC ID OU9LS802GAM2 - Guangdong Transtek Medical Electronics Co.,Ltd
OU9LS802GAM2

Blood pressure monitor

Jun 16, 2024

Equipment Class

PCB - PCS Licensed Transmitter
Blood pressure monitor - FCC ID OU9TMB2273BT - Guangdong Transtek Medical Electronics Co.,Ltd
OU9TMB2273BT

Blood pressure monitor

Jul 20, 2023

Equipment Class

DTS - Digital Transmission System