Thank you very much for selecting TRANSTEK Blood Pressure Monit or TMB-2288-BT. Please read the user manual carefully and thoroughtly so as to ensure the safe usage of this product, keep the manual well for further re ference in case you have problems. User Manual Version: A/0 Guangdong Transtek Medical Electronics Co., Ltd.Zone A, No.105, Dongli Road, Torch Development District, 528437 Zhongshan, Guangdong, China Blood pressure monitor Model: TMB-2288-BT FCC STATEMENT.................................................. ............................................................36 INTRODUCTION................................................... ............................................................... 2 General Description Indications for Use Measurement Principle Receiving and Inspecting your Monitor Safety Information Display and Symbols Name of Each Part Contents/Product IncludesBEFORE YOU START............................................... ...........................................................9 Choice of Power Supply Installing and Replacing the Batteries Setting the Date, Time and Voice Setting a user ID Pair a smart device with the monitorMEASUREMENT.................................................... ............................................................16 Applying the cuff Start a measurementDATA MANAGEMENT................................................ ........................................................20 Recall the Records Delete the RecordsINFORMATION FOR USER........................................... .....................................................25 Tips for measurement MaintenancesABOUT BLOOD PRESSURE........................................... ..................................................27 What are systolic pressure and diastolic pressure? What is the standard blood pressure classification? Irregular heartbeat detector Why does my blood pressure fluctuate throughout the day? Why do I get a different blood pressure at home compared to the hospital? Is the result the same if measuring on the right arm? TROUBLESHOOTING................................................ ........................................................30 SPECIFICATIONS................................................. .............................................................31 AUTHORIZED COMPONENT .......................................... .................................................32 CONTACT INFORMATION............................................ ....................................................32 EMC GUIDANCE................................................... .............................................................33 FCC STATEMENT.................................................. ............................................................36 ID ISED........................................................ ............................................................... ........37 Table of Contents CATALOGUE General Description INTRODUCTION INTRODUCTION Indications for Use Safety Information Measurement Principle FEATURES:• 124 mm × 76 mm Digital LCD display• Systolic, Diastolic Blood Pressure & Pulse Display• Date / Time Indication• Irregular Heartbeat detection• 2 × 250 memory storage, Guest mode available• Up-to-date measuring-during-inflation technology Check that the device packaging has not been tampered with and make sure that all contents are present. Before use, ensure that there is no visible damage to the device or accessories and that all packaging mate rial has been removed. If you have any doubts, do not use the device and contact your retailer or the specified Customer Services address. Receiving and Inspecting your Monitor This Blood Pressure Monitor is a digital monitor intended for u se in measuring blood pressure and pulse rate with arm circumference ranging fr om FPWRFP DERXWôÝòÝ FPWRFP DERXWôÝòÝ FPWRFP DERXWôÝôÝ It is intended for adult, home use.The device can be used to detect irregular pulse rate.2QO\WKHPDWFKHGFXIIRIFPWRFP DERXWôÝôÝ LVDSSOL FDEOHWR SUHJQDQWZRPDQ LQFOXGLQJSUHHFODPSVLDSDWLHQWV DQGGLDEHWLF SDWLHQWV The symbols below might be in the user manual, labeling or othe r component. They are the requirement of standard and using. Thank you for selecting TRANSTEK arm type blood pressure monito r 70%%7 7KHPRQLWRUIHDWXUHVEORRGSUHVVXUHPHDVXUHPHQW SXOVH rate measurement and the result storage. The design provides you with two years of reliable service. This product uses the Oscillometric Measuring method to detect blood pressure. Before every measurement, the unit establishes a “zer o pressure” equivalent to the atmospheric pressure. Then it start s inflating the arm cuff, meanwhile, the unit detects pressure oscillations generated E\EHDWWREHDWSXOVDWLOHZKLFKLVXVHGWRGHWHUPLQHWKHV\VWR OLFDQG diastolic pressure, and also pulse rate. Manufacturer Serial Number Type BF applied part Direct Current The symbol indicates that the product should not be discarded as unsorted waste but must be sent to separate collection facilities for recovery and recycling. Recyclable CautionIndicates that caution is necessary when operating the device o r control close to where the symbol is placed, or that the curren t situation needs operator awareness or operator action in order to avoid undesirable consequences. Date of manufacture For indoor use only Class II Equipment MD Medical Device Refer to instruction manual/bookletTo signify that the instruction manual/ booklet must be read.Note: The background color of the symbol is blue. MR UnsafeTo identify an item which poses unacceptable risks to the patie nt, medical staff or other persons within the MR environment. INTRODUCTION INTRODUCTION Precaution 7KLVGHYLFHLVLQWHQGHGIRULQGRRUKRPHXVHDQGLVQRWLQWHQ GHGIRUVHOIXVHLQSXEOLFDUHDV * This device is portable, but it is not intended for …
Text truncated - open the document above for the full version.
ApplicantDeclaration QSF27-14-04Rev1.0Rev.Feb6,2023Page 1 of 2 OriginalIssue:Jan.4,2021 SGSNorthAmericaInc. 620OldPeachtreeRoad SUITE100 Suwanee,Georgia30024 UnitedStates ApplicantLegalBusinessName GuangdongTranstekMedicalElectronicsCo.,Ltd Address ZoneA,No.105,DongliRoadTorchDevelopmentDistrictZhongshan,Guangdong,528437, China GranteeCode OU9 FCCID OU9TMB2273BT AuthorizedContactName JerryFan ContactEmail [email protected] ContactPhone +86-760-85166220 I,theundersigned,certifythatIamanauthorizedsignatoryfortheApplicantandthereforedeclare; a)inaccordancewith47CFR2.911(d),allofthestatementshereinandtheexhibitsattachedheretoaretrueandcorrecttothebestofmy knowledgeandbelief. b)inacceptingaGrantofEquipmentAuthorizationissuedbyaTCB,undertheauthorityoftheFCC,asaresultoftherepresentationsmadein thisapplication,theApplicantisresponsiblefor: (1)labelingtheequipmentwiththeexactFCCIDasspecifiedinthisapplication, (2)compliancestatementlabelingpursuanttotheapplicablerules, (3)complianceoftheequipmentwiththeapplicabletechnicalrules, c)iftheApplicantisnottheactualmanufactureroftheequipment,appropriatearrangementshavebeenmadewiththemanufacturertoensure thatproductionunitsofthisequipmentwillcontinuetocomplywiththeFCC’stechnicalrequirements. d)inaccordancewith47CFR2.909andKDB394321,theApplicanthasread,understoodandagreestoacceptthattheyaretheresponsible partyandagreetoabidebytheirresponsibilitiesasspecifiedunder47CFR2.909andKDB394321. e)inaccordancewithISO17065,FCCKDB641163,FCCKDB610077,KDB394321andRSP-100,theApplicanthasread,understood,accepts andagreestoabidebythepostmarketsurveillancerequirements. (1)theApplicantunderstands,acceptsandagreesthatasamplemayberequestedforsurveillancetesting. (2)theApplicantshallmakeprovisionstoalwayshaveaproductionsampleavailableuponrequestbySGS,FCCand/orISED. (3)theApplicantshall,uponrequestbySGS,attheApplicant’sexpense,provideaproductionsampleoftherequestedproducttoSGS, FCCand/orISEDasinstructed.Thesampleshallincludeallsupportdevices,cables,software,accessoriesorotherhardwareor softwarerequiredforevaluation,review,certificationandauditsurveillanceofproductscertifiedbySGS. f)neithertheApplicantnoranypartytotheapplicationissubjecttoadenialofFederalbenefits,thatincludesFCCbenefits,pursuanttoSection 5301oftheAnti-DrugAbuseActof1988,21U.S.C.§862becauseofaconvictionforpossessionordistributionofacontrolledsubstance.See 47CFR1.2002(b)forthedefinitionofa“party”forthesepurposes. g)theApplicanthasread,understood,acceptsandagreestoabidebytheSGSNorthAmerica,Inc.(TCB)termsandconditions. LinktoCFRs:https://www.fcc.gov/wireless/bureau-divisions/technologies-systems-and-innovation-division/rules-regulations-title-47 LinktoKDBs:https://apps.fcc.gov/oetcf/kdb/index.cfm LinktoRSP-100:https://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf01130.html LinktotheCoveredList:CoveredList [GuangdongTranstekMedicalElectronicsCo.,Ltd](“theapplicant”)certifiesthattheequipmentforwhichauthorizationissoughtisnot “covered”equipmentprohibitedfromreceivinganequipmentauthorizationpursuanttosection2.903oftheFCCrules. [GuangdongTranstekMedicalElectronicsCo.,Ltd](“theapplicant”)certifiesthat,asofthedateofthefilingoftheapplication,the applicant[isnot]identifiedontheCoveredlist,establishedpursuantto§1.50002,asanentityproducing“covered”equipment. ApplicantSignature: Date:2023-06-30 PrintName: JerryFan Title: RAManager *NOTE:ThisdeclarationcannotbesignedbyanAgent,itshallbesignedbyanauthorizedpersonlistedintheFCCdatabase ApplicantDeclaration QSF27-14-04Rev1.0Rev.Feb6,2023Page 2 of 2 OriginalIssue:Jan.4,2021 SGSNorthAmericaInc. 620OldPeachtreeRoad SUITE100 Suwanee,Georgia30024 UnitedStates
UNITED STATES DESIGNATED AGENT LETTER Date:20230630 TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 ApplicantU.S. designated agent Company Name:Guangdong Transtek Medical Electronics Co.,Ltd Company Name: MIO LABS INC. Grantee Code:OU9FRN: Contact Name: 0032569972 Contact Name:Jerry FanAddress: 4500 Great America Pkwy Suite 1023 Address:Zone A, No.105 ,Dongli Road Torch Development District Zhongshan , Guangdong/528437 Telephone: 157 286 6685 ext. 28(301- 910-0529) Telephone:+86-760-85166220 Email: [email protected] Email:[email protected] Applicable Equipment: FCC ID: < OU9TMB2273BT> ATTN: Director of Certification: We, < Guangdong Transtek Medical Electronics Co.,Ltd > and < MIO LABS INC. > understand and acknowledge the applicants consent and the designated agent’s obligation to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and e- mail of the designated agent listed above. We, < Guangdong Transtek Medical Electronics Co.,Ltd > and < MIO LABS INC. > acknowledge the applicant’s acceptance of its obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. ApplicantU.S. designated agent Name (Printed): Jerry FanName(Printed):Chengcen Su Title: RA Manager Title: Sales Manager Signature: Signature:
GuangdongTranstekMedicalElectronicsCo.,Ltd Date:2023-06-30 TO:FederalCommunicationCommission EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MID21046 Regarding:FCCID:OU9TMB2273BT Towhomitmayconcern: We,theundersigned,herebyauthorizeSGS-CSTCStandardsTechnicalServicesCo.,Ltd.toactonour behalfinallmannersrelatingtoapplicationforequipmentauthorizationwithrespecttotheFCCIDabove, includingsigningofalldocumentsrelatingtothesematters.Anyandallactscarriedoutbytheagenton ourbehalfshallhavethesameeffectasactsofourown. We,theundersigned,herebycertifythatwearenotsubjecttoadenialoffederalbenefits,thatincludes FCCbenefits,pursuanttoSection5301oftheAnti-DrugAbuseActof1988,21U.S.C.853(a). Whereouragentsignstheapplicationforcertificationonourbehalf,Iacknowledgethatallresponsibility forcomplyingwiththetermsandconditionsforCertification,asspecifiedbySGSNorthAmerica,Inc.,still resideswithGuangdongTranstekMedicalElectronicsCo.,Ltd. Thisauthorizationisvaliduntilfurtherwrittennoticefromtheapplicant. Sincerely, PrintName:JerryFanTitle:RAManager Signature: OnbehalfofCompany:GuangdongTranstekMedicalElectronicsCo.,Ltd Telephone:+86-760-85166220 E-mail:[email protected]
GuangdongTranstekMedicalElectronicsCo.,Ltd TO:FederalCommunicationCommission EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MID21046 Regarding:ConfidentialityRequestregardingapplicationforFCCID:OU9TMB2273BT LONGTERMCONFIDENTIALITY Pursuantto47CFRSection0.459and0.457ofthecommission’srules,theapplicantherebyrequest confidentialtreatmentofthedocumentslistedbelow,associatedwiththecertificationapplication referencedabove. Schematic(s) BlockDiagrams OperationalDescriptions Thedocumentsabovecontainproprietaryinformationnotreleasedtothepublic.Publicdisclosureofthis informationmayproveharmfultothebusinessoftheapplicant. SHORTTERMCONFIDENTIALITY Additionally,theapplicantrequeststhefollowingdocumentsbeheldconfidentialuntilthedeviceis marketedor180daysfromthegrantdate,whicheverisless.Ifthedeviceismarketedwithin aforementioneddaysoftheGrantDate,theapplicantwillnotifytheTCBperFCCKDB726920D01 ConfidentialityRequestProcedures. ExternalPhotos InternalPhotos TestSetupPhotos Usermanual(s) Sincerely, PrintName:JerryFanTitle:RAManager Signature: OnbehalfofCompany:GuangdongTranstekMedicalElectronicsCo.,Ltd Telephone:+86-760-85166220 E-mail:[email protected]
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A02 Rev.A/0 Page: 1 of 9 Appendix External Photos for SZCR2305001549ME FCC ID: OU9TMB2273BT SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A02 Rev.A/0 Page: 2 of 9 EUT Constructional Details (EUT Photos) Model No.: TMB-2273-BT SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A02 Rev.A/0 Page: 3 of 9 Label location SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A02 Rev.A/0 Page: 4 of 9 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A02 Rev.A/0 Page: 5 of 9 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A02 Rev.A/0 Page: 6 of 9 Model No.: TMB-2288-BT SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A02 Rev.A/0 Page: 7 of 9 Label location SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A02 Rev.A/0 Page: 8 of 9 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A02 Rev.A/0 Page: 9 of 9 - End of the Appendix -
TMB-2273-BT label SN:2EB1290230300001-2EB1290230300120 Dimension:50.5 x 19.6 mm Colour: 单黑 + Pantone Reflex Blue C Material:60# paper with white background 60#珠光特制胶水+哑膜 (白底) 50.5 19. 6 50.5 19. 6 PO#2BEB1290 Model: TMB-2273-BT IP Classification: IP21 Made in China Blood Pressure Monitor Guangdong Transtek Medical Electronics Co., Ltd. Zone A, No.105, Dongli Road, Torch Development District, 528437 Zhongshan, Guangdong, China AC adapter powered mode: 5V 1A (Please use the AC adapter authorized by the manufacturer!) 2023-03 Optional! Rating: 3.7V/1000mAh built-in rechargeable li-polymer battery (21)2EB1290230300001 (01)XXXXXXXXXXXXXX GS1 Datamatrix (UDI) SN FCC ID: OU9TMB2273BT IC 12725A-TMB2273BT
零件图号 TMB-2088-AC -0 2 61.5±0.2 22.0±0. 2 1 2 R2 .0 Model: TMB-2288-BT IP Classification: IP21 Made in China Blood Pressure Monitor Guangdong Transtek Medical Electronics Co., Ltd. Zone A, No.105, Dongli Road, Torch Development District, 528437Zhongshan, Guangdong, China Rating: Battery powered mode: 4x AA batteries, 6V AC adapter powered mode: 5V 1A (Please use the AC adapter authorized by the manufacturer!) SN (21)2EB1196221200001 Colour:单黑 + Pantone Reflex Blue C + Pantone 185C Dimension:61.5 x 22 mm Material:60# paper with white background 2022-12 (01)XXXXXXXXXXXXXX GS1 Datamatrix (UDI) 注:当前材质为白底! 如果想换银底,请换成下述材质: 50#哑银咪钠不干胶+哑膜 (Optional!) (Optional!) FCC ID: OU9TMB2273BT IC 12725A-TMB2273BT
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A03 Rev.A/0 Page: 1 of 7 Appendix Internal Photos for SZCR2305001549ME FCC ID:OU9TMB2273BT SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A03 Rev.A/0 Page: 2 of 7 EUT Constructional Details (EUT Photos) Model No.: TMB-2273-BT SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A03 Rev.A/0 Page: 3 of 7 Antenna SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A03 Rev.A/0 Page: 4 of 7 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A03 Rev.A/0 Page: 5 of 7 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A03 Rev.A/0 Page: 6 of 7 Model No.: TMB-2288-BT SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A03 Rev.A/0 Page: 7 of 7 - End of the Appendix - Antenna
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230500154903 Page: 1 of 10 Keny Xu EMC Laboratory Manager 1 Cover page RF Exposure Report Application No.: SZCR2305001549ME Applicant: Guangdong Transtek Medical Electronics Co., Ltd Address of Applicant: Zone A, No.105, Dongli Road, Torch Development District, 528437 Zhongshan, Guangdong, China. Manufacturer: Guangdong Transtek Medical Electronics Co., Ltd Address of Manufacturer: Zone A, No.105, Dongli Road, Torch Development District, 528437 Zhongshan, Guangdong, China. Factory: Guangdong Transtek Medical Electronics Co., Ltd Address of Factory: Zone A, No.105, Dongli Road, Torch Development District, 528437 Zhongshan, Guangdong, China. Equipment Under Test (EUT): EUT Name: Blood pressure monitor Model No.: TMB-2273-BT, TMB-2273-B, TMB-2288-BT, TMB-2288-B, TMB-2288-C ♣ ♣ Please refer to section 4.1 of this report which indicates which model was actually tested and which were electrically identical. FCC ID: OU9TMB2273BT Standards: FCC Rules 47 CFR §2.1093 KDB 447498 D04 interim General RF Exposure Guidance v01 Date of Receipt: 2023-05-22 Date of Test: 2023-05-26 to 2023-05-31 Date of Issue: 2023-06-02 Test Result : Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230500154903 Page: 2 of 10 2 Version Revision Record Version Chapter Date Modifier Remark 01 2023-06-02 Original Authorized for issue by: Edison Li/Project Engineer Eric Fu/Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230500154903 Page: 3 of 10 3 Contents Page 1 COVER PAGE .............................................................................................................................................. 1 2 VERSION ...................................................................................................................................................... 2 3 CONTENTS .................................................................................................................................................. 3 4 GENERAL INFORMATION .......................................................................................................................... 4 4.1 GENERAL DESCRIPTION OF E.U.T. .......................................................................................................... 4 4.2 DETAILS OF EUT .................................................................................................................................... 5 4.3 SEPARATION DISTANCE .......................................................................................................................... 5 4.4 TEST LOCATION ...................................................................................................................................... 6 4.5 TEST FACILITY ........................................................................................................................................ 6 4.6 DEVIATION FROM STANDARDS ................................................................................................................. 6 4.7 ABNORMALITIES FROM STANDARD CONDITIONS ....................................................................................... 6 4.8 OTHER INFORMATION REQUESTED BY THE CUSTOMER ............................................................................. 6 5 FCC RADIOFREQUENCY RADIATION EXPOSURE LIMITS .................................................................... 7 5.1 BLANKET 1 MW BLANKET EXEMPTION ..................................................................................................... 7 5.2 MPE-BASED EXEMPTION ........................................................................................................................ 7 5.3 SAR-BASED EXEMPTION ......................................................................................................................... 8 6 MEASUREMENT AND CALCULATION .................................................................................................... 10 6.1 MAXIMUM TRANSMIT POWER ................................................................................................................. 10 6.2 RF EXPOSURE CALCULATION ................................................................................................................ 10 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230500154903 Page: 4 of 10 4 General Information 4.1 General Description of E.U.T. Product Type: Portable device Mobile device Fixed device Remark: Model No.: TMB-2273-BT, TMB-2273-B, TMB-2288-BT, TMB-2288-B, TMB-2288-C The model TMB-2273-BT and TMB-2288-BT were fully tested, since according to the declaration from the applicant, the electrical circuit design, layout, components used, internal wiring and functions were identical for all the above models, with only difference on model No., appearance, keypads, power supply and software. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230500154903 Page: 5 of 10 4.2 Details of EUT Power supply: TMB-2273-BT AC Adapter Model: BLJ06L050100U-U Input: AC 100-240V, 50/60Hz, 0.2A Max Output: DC 5.0V, 1.0A, 5.0W 3.7V, 1000mAh built-in rechargeable li-polymer battery TMB-2288-BT AC Adapter Model: BLJ06L050100U-U Input: AC 100-240V, 50/60Hz, 0.2A Max Output: DC 5.0V, 1.0A, 5.0W DC 6V(4 x AAA batteries) Cable(s): Type-C cable:100cm unshielded Operation Frequency: 2402MHz to 2480MHz Bluetooth Version: V5.0 Modulation Type: GFSK Number of Channels: 40 Channel Spacing: 2MHz Antenna Type: PCB Antenna Antenna Gain: -2dBi Remark:The information in this section is provided by the applicant or manufacturer, SGS is not …
Text truncated - open the document above for the full version.
Testing Report Product Name: TMB-2273-BT/ TMB-2288-BT Issue Date: 2023.7. 4 Engineer: Date 2023.7.4 Auditor: Date 2023.7.4 Approve Date 2023.7.4 Content 1. General Information 1.1 General information of testing institutions 1.2 Test equipment 1.3 Test environment 1.4 Statement 2. Sample Information 2.1 Client information 2.2 Description of EUT(S) 2.3 EUT appearance 2.4 DUT setup photo of free space OTA testing 3. Test Result 3.1 Test standard 3.2 Test uncertainty 3.3 Test data 3.3.1 S1l parameters 3.3.2 VSWR 3.3.3 Typical free space efficiency and gain 3.3.4 Typical free space radiation patter 1. General Information 1. 1 General information of testing institutions Name Shenzhen DBT Communication Device Co., Ltd Address Rm505, 8th building, Yungu 2nd period, pingshan No.1 Road, Xili Town,Nanshan District, ShenZhen , China Tel 0755-83763273 E-mail [email protected] Equipment 1. RayZone 1800 2. Keysight E5071C 1.2 Test equipment Satimo E5071C Cmw500 8960 Model No. Manufacturer Calibration date Next calibration date Satimo RFI-LAB-RF-A00 2022.11 13 2023.11 13 Cmw500 ROHDE&SCHWAR 8960 Agilent E5071C Agilent 1.3 Test environment Temperature 25. 0*C Humidity 59%RH Pressure 100.12kPa 1.4 Statement (1) The test results in the report are only applicable to the tested samples and the tested samples work under the environment described in the report (2) Any objection to this report shall be raised 30 days after formal confirmation of the report. (3) The report is invalid without the signature of the auditor and approver. 2.Sample Information 2.1 Client information Name Guangdong Transtek Medical Electronics Co., Ltd. Address Zone A, No. 105 , Dong Li Road, Torch Development District, zhongShan, Guangdong,China Contacts Tel E-mail 2.2 Description of EUT(S) Product Name 2.4 GHz Antenna Antenna Size 13.5*7.5mm Antenna Type PCB Test Item VSWR; Gain; Efficiency; Radiation pattern Frequency Range 2402-2480MHz Received Date 2023.7.4 Test Date 2023.7.4 Remark i 2.3 EUT appearance See test report 2.4 DUT setup photo of free space OTA testing Zenith is at Theta » 0° 3.Test Results 3.1 Test standard Name Parameter Method Standard no. Mobile Communication antenna VSWR Generic specification for antennas used in the mobile communications GB/T 9410-2008 Antenna gain Radiation pattern Antenna Radiation efficiency IEEE Standard Test Procedures for Antennas ANSI/IEEE Std 149-1979 3.2 Test uncertainty The uncertainty was calculated on the basis of the GUM published by ISO.using the inclusion factor of K=2 and the 95% confidence level to express the extended uncertainty. Item Uncertainty VSWR ±0.3 Antenna gain + ldB Radiation efficiency ±10% 3.3 Test data 3.3.1 S1l parameters 3.3.2 VSWR Frequency/MHz 2400 2450 2500 VSWR 1.819 1.97 2.205 3.3.3 Typical free space efficiency and gain Frequency MHz 2400 2410 2420 2430 2440 2450 2460 2470 2480 2490 2500 Peak Gain dBi -2.01 -2.36 -2.14 -2.74 -2.7 -3.34 -2.87 -3.45 -2.3 -3.47 -2 Efficiency % 27.25 24.49 24.52 21.8 23.11 19.98 22.51 19.97 25.64 19.86 27.06 3.3.4 Typical free space radiation p atter
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230500154902 Page: 1 of 59 Keny Xu EMC Laboratory Manager TEST REPORT Application No.: SZCR2305001549ME Applicant: Guangdong Transtek Medical Electronics Co., Ltd Address of Applicant: Zone A, No.105, Dongli Road, Torch Development District, 528437 Zhongshan, Guangdong, China. Manufacturer: Guangdong Transtek Medical Electronics Co., Ltd Address of Manufacturer: Zone A, No.105, Dongli Road, Torch Development District, 528437 Zhongshan, Guangdong, China. Factory: Guangdong Transtek Medical Electronics Co., Ltd Address of Factory: Zone A, No.105, Dongli Road, Torch Development District, 528437 Zhongshan, Guangdong, China. Equipment Under Test (EUT): EUT Name: Blood pressure monitor Model No.: TMB-2273-BT, TMB-2273-B, TMB-2288-BT, TMB-2288-B, TMB-2288-C ♣ ♣ Please refer to section 2 of this report which indicates which model was actually tested and which were electrically identical. FCC ID: OU9TMB2273BT Standard(s) : 47 CFR Part 15, Subpart C 15.247 Date of Receipt: 2023-05-22 Date of Test: 2023-05-26 to 2023-05-31 Date of Issue: 2023-06-02 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230500154902 Page: 2 of 59 Revision Record Version Chapter Date Modifier Remark 01 2023-06-02 Original Authorized for issue by: Edison Li/Project Engineer Eric Fu/Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230500154902 Page: 3 of 59 2 Test Summary Radio Spectrum Technical Requirement Item Standard Method Requirement Result Antenna Requirement 47 CFR Part 15, Subpart C 15.247 N/A 47 CFR Part 15, Subpart C 15.203 & 15.247(b)(4) Pass Radio Spectrum Matter Part Item Standard Method Requirement Result Conducted Emissions at AC Power Line (150kHz-30MHz) 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 6.2 47 CFR Part 15, Subpart C 15.207 Pass Conducted Peak Output Power ANSI C63.10 (2013) Section 11.9.1 47 CFR Part 15, Subpart C 15.247(b)(3) Pass Minimum 6dB Bandwidth ANSI C63.10 (2013) Section 11.8.1 47 CFR Part 15, Subpart C 15.247a(2) Pass Power Spectrum Density ANSI C63.10 (2013) Section 11.10.2 47 CFR Part 15, Subpart C 15.247(e) Pass Conducted Band Edges Measurement ANSI C63.10 (2013) Section 11.13.3.2 47 CFR Part 15, Subpart C 15.247(d) Pass Conducted Spurious Emissions ANSI C63.10 (2013) Section 11.11 47 CFR Part 15, Subpart C 15.247(d) Pass Radiated Emissions which fall in the restricted bands ANSI C63.10 (2013) Section 6.10.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions Below 1GHz ANSI C63.10 (2013) Section 6.4,6.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions Above 1GHz ANSI C63.10 (2013) Section 6.6 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Remark: Model No.: TMB-2273-BT, TMB-2273-B, TMB-2288-BT, TMB-2288-B, TMB-2288-C The model TMB-2273-BT was fully tested, since according to the declaration from the applicant, the electrical circuit design, layout, components used, internal wiring and functions were identical for all the above models, with only difference on model No., appearance, keypads, power supply and software. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230500154902 Page: 4 of 59 3 Contents Page 1 Cover Page ................................................................................................................................................ 1 2 Test Summary ........................................................................................................................................... 3 3 Contents ........................…
Text truncated - open the document above for the full version.
No.1 Workshop, M-10, Middle Section Science & Tech · Shenzhen · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 600.00 µW |
Body Fat Scale
Equipment Class
PCB - PCS Licensed TransmitterBlood Pressure monitor
Equipment Class
DTS - Digital Transmission System
Blood Pressure monitor
Equipment Class
PCB - PCS Licensed Transmitter
Blood pressure monitor
Equipment Class
PCB - PCS Licensed Transmitter
Blood pressure monitor
Equipment Class
DTS - Digital Transmission System