LS802-GP standard User Manual Size100 x 140 mm Material (recommened): 80g/m² (80g) Color: black Customizable : Update your company contact information on back cover and Page 21 Transtek Logo → Customized Logo Please read the user manual carefully and thoroughtly so as to ensure the safe usage of this product, keep the manual well for further reference in case you have problems. version:1.0 User Manual Blood Pressure Monitor LS802-GP Guangdong Transtek Medical Electronics Co., Ltd. Zone A, No.105, Dongli Road, Torch Development District, Zhongshan, 528437, Guangdong, China CATALOGUE 1 INTRODUCTION...................................................................................................................2 General Description Indications for Use Contraindications Measurement Principle Safety Information Display and Symbols Name of Each Part Contents/Product Includes BEFORE YOU START.............................................................................................................9 The Choice of Power Supply Installing and Replacing the Batteries MEASUREMENT.................................................................................................................11 Applying the cuff Taking a measurement INFORMATION FOR USER..................................................................................................14 Tips for measurement Maintenances ABOUT BLOOD PRESSURE..................................................................................................16 What are systolic pressure and diastolic pressure? What is the standard blood pressure classification? Irregular heartbeat detector Why does my blood pressure fluctuate throughout the day? Why do I get a different blood pressure at home compared to the hospital? Is the result the same if measuring on the right arm? TROUBLESHOOTING..........................................................................................................19 SPECIFICATIONS................................................................................................................20 AUTHORIZED COMPONENT ..............................................................................................21 CONTACT INFORMATION..................................................................................................21 FCC STATEMENT................................................................................................................22 EMC GUIDANCE.................................................................................................................23 Table of Contents INTRODUCTIONINTRODUCTION 2 3 General Description Safety Information FEATURES: • 78 mm × 92 mm Digital LCD display • Systolic, Diastolic Blood Pressure & Pulse Display • Date / Time Indication • Irregular Heartbeat detection • Up-to-date measuring-during-inflation technology • E-MTC wireless communication Thank you for selecting this arm type blood pressure monitor (LS802-GP). The monitor features blood pressure measurement, pulse rate measurement and the result storage. The design provides you with two years of reliable service. The symbols below might be in the user manual, labeling or other component. They are the requirement of standard and using. Indications for Use Measurement Principle This Pro Cellular Blood Pressure Monitor LS802-GP is a digital monitor intended for use in measuring blood pressure and heartbeat rate with arm circumference ranging from 22 cm to 32 cm22 cm to 42 cm22 cm to 45 cm. The device can be used to detect irregular heartbeat. It is intended for adult, home use. 1.The device is not suitable for use on the women who are or may be pregnant. 2.The device is not suitable for use on patients with implanted,electrical devices, such as cardiac pacemakers, defibrillators. Contraindications This product uses the Oscillometric Measuring method to detect blood pressure. Before every measurement, the unit establishes a “zero pressure” equivalent to the atmospheric pressure. Then it starts inflating the arm cuff, meanwhile, the unit detects pressure oscillations generated by beat-to-beat pulsatile, which is used to determine the systolic and diastolic pressure, and also pulse rate. MR Unsafe To identify an item which poses unacceptable risks to the patient, medical staff or other persons within the MR environment. Manufacturer Serial Number Type BF applied part Direct Current The symbol indicates that the product should not be discarded as unsorted waste but must be sent to separate collection facilities for recovery and recycling. Recyclable Caution Indicates that caution is necessary when operating the device or control close to where the symbol is placed, or that the current situation needs operator awareness or operator action in order to avoid undesirable consequences. Humidity limitation Temperature limit Atmospheric pressure limitation Refer to instruction manual/booklet To signify that the instruction manual/ booklet must be read. Date and Country of manufacture For indoor use only Symbol for “Class II Equipment” CAUTION CAUTION * Warning: This device is not AP/APG equipment. Do not use the device where flammable anesthetic are present, or in environments mixture with air of with oxygen or nitrous oxide. * The device contains sensitive electronic components.To avoid measurement errors, avoid taking blood pressure measurements near a strong electromagnetic field radiated interference signal or electrical fast transient/burst signal. * Wireless communication equipment, such as wireless home network devices, mobile phones, cordless telephones and their base stations, walkie-talkies may cause interference that may affect the accuracy of measurements. A minimum distance of 1 foot (30 cm) should be kept from such devices during a measurement. * You can use this device to take your own measurement, no third-party operator is required. * Please use the device under the environment which is provided in the user manual. Othe…
Text truncated - open the document above for the full version.
Guangdong Transtek Medical Electronics Co.,Ltd Date: 2022/06/06 TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Regarding: FCC ID: OU9LS802GPM3 To whom it may concern: We, the undersigned, hereby authorize Compliance Certification Services (Kunshan) Inc and Kidd Yang in Compliance Certification Services (Kunshan) Inc to act on our behalf in all manners relating to application for equipment authorization with respect to the FCC ID above, including signing of all documents relating to these matters. Any and all acts carried out by the agent on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Where our agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by SGS North America, Inc., still resides with Guangdong Transtek Medical Electronics Co.,Ltd This authorization is valid until further written notice from the applicant. Print Name: Jerry Fan Title: RA Manager Signature: On behalf of Company: Guangdong Transtek Medical Electronics Co.,Ltd Telephone: +86-760-85166220 E-mail: [email protected]
Guangdong Transtek Medical Electronics Co.,Ltd TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Regarding: Confidentiality Request regarding application for FCC ID: OU9LS802GPM3 LONG TERM CONFIDENTIALITY Pursuant to 47 CFR Section 0.459 and 0.457 of the commission’s rules, the applicant hereby request confidential treatment of the documents listed below, associated with the certification application referenced above. Schematic(s) Block Diagrams Operational Descriptions Tune up procedure BOM The documents above contain proprietary information not released to the public. Public disclosure of this information may prove harmful to the business of the applicant. Sincerely, Print Name: Jerry Fan Title: RA Manager Signature: On behalf of Company: Guangdong Transtek Medical Electronics Co.,Ltd Telephone: +86-760-85166220 E-mail: [email protected]
Applicant Declaration Applicant Declaration Rev:0.0 SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia 30024 United States Applicant Legal Business Name Guangdong Transtek Medical Electronics Co.,Ltd Address Zone A, No.105,Dongli Road, Torch Development District, Zhongshan,528437, Guangdong, China Grantee Code OU9 FCC ID OU9LS802GPM3 Authorized Contact Name Jerry Fan Contact Email [email protected] Contact Phone +86-760-85166220 I, the undersigned, certify that I am an authorized signatory for the Applicant and therefore declare; a) in accordance with 47CFR2.911(d), all of the statements herein and the exhibits attached hereto are true and correct to the best of my knowledge and belief. b) in accepting a Grant of Equipment Authorization issued by a TCB, under the authority of the FCC, as a result of the representations made in this application, the Applicant is responsible for: (1) labeling the equipment with the exact FCC ID as specified in this application, (2) compliance statement labeling pursuant to the applicable rules, (3) compliance of the equipment with the applicable technical rules, c) if the Applicant is not the actual manufacturer of the equipment, appropriate arrangements have been made with the manufacturer to ensure that production units of this equipment will continue to comply with the FCC’s technical requirements. d) in accordance with 47 CFR 2.909 and KDB394321, the Applicant has read, understood and agrees to accept that they are the responsible party and agree to abide by their responsibilities as specified under 47 CFR 2.909 and KDB394321. e) in accordance with ISO17065, FCC KDB641163, FCC KDB610077, KDB394321 and RSP-100, the Applicant has read, understood, accepts and agrees to abide by the post market surveillance requirements. (1) the Applicant understands, accepts and agrees that a sample may be requested for surveillance testing. (2) the Applicant shall make provisions to always have a production sample available upon request by SGS, FCC and/or ISED. (3) the Applicant shall, upon request by SGS, at the Applicant’s expense, provide a production sample of the requested product to SGS, FCC and/or ISED as instructed. The sample shall include all support devices, cables, software, accessories or other hardware or software required for evaluation, review, certification and audit surveillance of products certified by SGS. f) neither the Applicant nor any party to the application is subject to a denial of Federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. §862 because of a conviction for possession or distribution of a controlled substance. See 47CFR 1.2002(b) for the definition of a “party” for these purposes. g) the Applicant has read, understood, accepts and agrees to abide by the SGS North America, Inc.(TCB) terms and conditions. Link to CFRs: https://www.fcc.gov/wireless/bureau-divisions/technologies-systems-and-innovation-division/rules-regulations-title-47 Link to KDBs: https://apps.fcc.gov/oetcf/kdb/index.cfm Link to RSP-100: https://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf01130.html Applicant Signature: Date: 2022/06/06 Print Name: Jerry Fan Title: RA Manager *NOTE: This declaration cannot be signed by an Agent, it shall be signed by an authorized person listed in the FCC database
Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 1 of 5 External Photos for FYCR2205000201ME Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 2 of 5 EUT Constructional Details (EUT Photos) Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 3 of 5 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 4 of 5 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 5 of 5
2021-05 IMEI: 860112041384475 (01)16932825325000 (21)101205600001 SN IP Degree: IP21 Guangdong Transtek Medical Electronics Co., Ltd. Zone A, No.105, Dongli Road, Torch Development District, Zhongshan, 528437, Guangdong, China Model: LS802-GP AC adapter powered mode: 6V 1A Rating: Battery powered mode: 4x AA batteries, 6V FCC ID: OU9LS802GPM3 (Please use the AC adapter authorized by the manufacturer!) Blood Pressure Monitor LS802-GP-rating label Colourblack text with white background & Pantone Reflex Blue C Symbol +Pantone 185 C + balck Symbol Dimension61.5 x 29.5mm Material50# PET Thermal paper 50# PET Location for Rating Label 1) Make sure the SN of the UDI on the rating label is consistent with the one on the gift box label. 2) Make sure the IMEI code on the rating label is consistent with the ones on the gift box label and carton box label. 注/Remakrs: 1)背贴上UDI中含有的SN流水号要与彩盒贴纸上UDI中含有的SN流水号一一对应! 2)背贴上IMEI号要与彩盒贴纸上的IMEI号 以及 卡通箱贴纸里的10个IMEI号一一相对应! Product code, "1"for bp unit, "2" for scale unit Customer code (hex assigned by Transtek) For the data "101202300001" above, it means the product is Blood Pressure Monitor, the customer code Transtek assigned is "01” and the Blood Pressure Monitor is produced on the 23th week of year 2020 and its serial number is “00001”. Important Notes: 1To be available and convenient to generated and printed the label on Transtek MES system, without permission, it is not allowed to change the coding rules of the 12-bit SN, the size/material/color of the label. 2) It is allowed to change the TRANTEK LOGO and model no. "LS802-GS" to your own, Transtek manufacuter information to “manufactured for “Distributed by:” + you company name & address under the FDA registration 3) Genenally, If you are going to customize, such as LOGO, model number, manufacuter info, please provide Transtek the Device Identifier (DI) Information to print the UDI ( GS1 datamatrix barcode) . To import the goods smoothly, It is kind remind to release the DI under the GUDID system timely. 4) If required, Transtek could apply for device Identifier (DI) Information for customer on behalf of the manufacturer. but there is some limit , such as need to use Transtek standard artworks, the authorization from customer to use the LOGO or other necessary information. Contact Transtek for more details. 产品代码 1-血压计;2-秤 客户代码(客户ID) (十六进制) 流水编号 (00001-99999) 生产年份生产周数 比如框中的 "101202300001" 代表Transtek为客户代码为01的客户在2020年第23周生产的第1台血压计产品,对应的流水号为“00001”。 Build Year YY / Calendar Build Week WW Calendar Serial numbers (00001-99999) 101202300001 Notice: The layout of highlighted pink part is fixed, pls do not make any changes. IMEI code (it come from the communication module on the device) 35*4mm 是模块上的IMEI号,生产的时候,产线用扫描枪扫描通讯模块屏蔽罩表面的二维码可以识别出IMEI号 YYYY-MM UDI (GS1 Datamatrix ) UDI=DI+PI, UDIDI+PI DI(01)+140114 PI(21)+12 () 1"1"2, 3ID21 3 4 Notice: Concerning the illustrate for the rating label, for customer, please refer to the content highlight in blue color only. The serial numbers following the serial number identifier (21) of the UDI is cosist of 12-bit datas. The code rules as below The data below is just an example to explain the serial number code rules. UDI的流水号标识符(21)后面的流水号是由12位数值构成, 相关的编码规则如下: FCC STATEMENT This device complies with Part 15 of the FCC Rules. Operation is subjectto the following two conditions: (1) this device may not cause harmfulinterference, and (2) this device must accept any interference received,including interference that may cause undesired operation.
Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 1 of 7 Internal Photos for FYCR2205000201ME Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 2 of 7 EUT Constructional Details (EUT Photos) Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 3 of 7 Antenna Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 4 of 7 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 5 of 7 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 6 of 7 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 7 of 7
Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Report No.: FYCR220500020104 Page: 1 of 7 EMC Technical Manager 1 Cover Page RF Exposure Report Application No.: FYCR2205000201ME Applicant: Guangdong Transtek Medical Electronics Co., Ltd Address of Applicant: Zone A, No.105, Dongli Road, Torch Development District, Zhongshan, 528437, Guangdong, China Manufacturer: Guangdong Transtek Medical Electronics Co., Ltd Address of Manufacturer: Zone A, No.105, Dongli Road, Torch Development District, Zhongshan, 528437, Guangdong, China Factory: Guangdong Transtek Medical Electronics Co., Ltd Address of Factory: Zone A, No.105, Dongli Road, Torch Development District, Zhongshan, 528437, Guangdong, China Equipment Under Test (EUT): EUT Name: Blood pressure monitor Model No.: LS802-GP FCC ID: OU9LS802GPM3 Standard(s) : 47 CFR Part 2.1091 47 CFR Part 1.1310 47 CFR Part 1.1307 Date of Receipt: 2022-05-30 Date of Test: 2022-06-01 to 2022-06-16 Date of Issue: 2022-06-20 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Report No.: FYCR220500020104 Page: 2 of 7 Revision Record Version Chapter Date Modifier Remark 01 2022-06-20 Original Authorized for issue by: Tree Zhan/Project Engineer Winkey Wang/Reviewer Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Report No.: FYCR220500020104 Page: 3 of 7 2 Contents Page 1 COVER PAGE .............................................................................................................................. 1 2 CONTENTS .................................................................................................................................. 3 3 GENERAL INFORMATION ........................................................................................................... 4 3.1 DETAILS OF E.U.T. .................................................................................................................. 4 3.2 TEST LOCATION ...................................................................................................................... 5 3.3 TEST FACILITY ........................................................................................................................ 5 4 RADIO SPECTRUM TECHNICAL REQUIREMENT ...................................................................... 6 4.1.1 RF Exposure .................................................................................................... 6 4.1.2 Requirement ..................................................................................................... 6 4.1.3 Method .............................................................................................................. 7 4.1.4 Conclusion ........................................................................................................ 7 4.2 EUT CONSTRUCTIONAL DETAILS .............................................................................................. 7 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Report No.: FYCR220500020104 Page: 4 of 7 3 General Information 3.1 Details of E.U.T. Power supply: AC Adapter Model: BLJ06L060100P-U Input: AC 100-240V, 50/60Hz, 0.2A Max Output: DC 6.0V, 1000mA DC 6V (4*AA batteries) Test voltage: AC 120V, 60Hz Note: Both nominal AC 120V, 60Hz and AC 240 V, 60Hz are required for testing in accordance with FCC KDB174176, this report only shows the results of the worst test result(AC 120V, 60Hz); Cable(s): DC cable:146cm unshielded Sample Type: Fixed production CatM Band Operation Frequency Band: CatM1 Band 2, 4, 12, 13, 25 Modulation Type: QPSK, 16QAM Antenna Type: PIFA Antenna Antenna Gain: CatM1 Band 2: 2.96dBi, CatM1 Band 4: 3.44dBi, CatM1 Band 12: 1.09dBi, CatM1 Band 13: 1.72dBi, CatM1 Band 25: 2.96dBi GSM Band Support Network: GPRS, EGPRS Operation Frequency Band: GSM850/GSM1900 Modulation Type: GMSK for GSM/GPRS/EGPRS 8PSK for EGPRS Supported Channel Bandwidth: 200KHz Antenna Type: PIFA Antenna Antenna Gain: GSM850: -0.58dBi GSM1900: 2.96dBi Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Report No.: FYCR220500020104 Page: 5 of 7 3.2 Test Location All tests were performed at: Compliance Certification Services(Kunshan)Inc. Shenzhen branch. Fuyong lab. Xinlong TechnoPark,Fengtang Road, Fuyong Subdistrict, Bao’an, Shenzhen, China Tel: +86 755 8866 3988 Fax: +86 755 2671 0594 No tests were sub-contracted. 3.3 Test Facility The test facility is recognized, certified, or accredited by the following organizations: • A2LA (Certificate No. 6606.01) Compliance Certification Services(Kunshan)Inc. Shenzhen branch is accredited by the American Association for Laboratory Accreditation(A2LA). Certificate No. 6606.01. • FCC –Designation Number: CN1322 Compliance Certification Services(Kunshan)Inc. Shenzhen branch has been recognized as an accredited testing laboratory. Designation Number: CN1322. Test Firm Registration Number: 718073 • Innovation, Science and Economic Development Canada Compliance Certification Services(Kunshan)Inc. Shenzhen branch has been recognized by ISED as an accredited testing laboratory. CAB identifier: CN0129. IC#: 28189. Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Report No.: FYCR220500020104 Page: 6 of 7 4 Radio Spectrum Technical Requirement 4.1.1 RF Exposure 4.1.2 Requirement In accordance with 47 CFR FCC Part 2.1091, this device has been defined as a mobile device whereby a distance of 0.2m normally can be maintained between the user and the device. According to 47 CFR FCC Part 1310, the criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in Part1.1307(b). T ABLE 1 TO §1.1310(E)(1) —L IMITS FOR M AXIMUM P ERMISSIBLE E XPOSURE (MPE) Frequency range (MHz) Electric field strength (V/m) Magnetic field strength (A/m) Power density (mW/cm 2 ) Averaging time (mi…
Text truncated - open the document above for the full version.
Frequency Error VS. Voltage Test Band Test mode Test Channel Test Temp. Test Volt. Freq. Error [Hz] Freq. vs. rated [ppm] Verdict CatM1 band2 QPSK/ 20MHz LCH TN VL -1.54 -0.00083 PASS VN 3.41 0.00183 PASS VH 0.29 0.00016 PASS MCH TN VL 4.45 0.00237 PASS VN 0.18 0.00010 PASS VH 1.85 0.00098 PASS HCH TN VL 1.43 0.00075 PASS VN 1.82 0.00096 PASS VH 2.24 0.00118 PASS 16QAM/ 20MHz LCH TN VL -2.32 -0.00125 PASS VN -1.03 -0.00055 PASS VH -1.16 -0.00062 PASS MCH TN VL 3.47 0.00185 PASS VN -0.9 -0.00048 PASS VH 2.53 0.00135 PASS HCH TN VL -1. 11 -0.00058 PASS VN -0.08 -0.00004 PASS VH 3.38 0.00178 PASS Test Band Test mode Test Channel Test Temp. Test Volt. Freq. Error [Hz] Freq. vs. rated [ppm] Verdict CatM1 band4 QPSK/ 20MHz LCH TN VL -1.61 -0.00094 PASS VN 3.38 0.00197 PASS VH 1.21 0.00070 PASS MCH TN VL 3.21 0.00185 PASS VN 0.1 0.00006 PASS VH 3.58 0.00207 PASS HCH TN VL 0.44 0.00025 PASS VN 1.79 0.00103 PASS VH 2.18 0.00125 PASS 16QAM/ 20MHz LCH TN VL -1.8 -0.00105 PASS VN -0.49 -0.00028 PASS VH 1.34 0.00078 PASS MCH TN VL 2.92 0.00169 PASS VN -0.38 -0.00022 PASS VH 3.01 0.00174 PASS HCH TN VL -0.6 -0.00034 PASS VN 0.43 0.00025 PASS VH 2.88 0.00165 PASS Test Band Test mode Test Channel Test Temp. Test Volt. Freq. Error [Hz] Freq. vs. rated [ppm] Verdict CatM1 band12 QPSK/ 10MHz LCH TN VL -1.49 -0.00212 PASS VN 2.8 0.00398 PASS VH 1.34 0.00190 PASS MCH TN VL 4.5 0.00636 PASS VN 0.25 0.00035 PASS VH 2.68 0.00379 PASS HCH TN VL 0.54 0.00076 PASS VN 1.9 0.00267 PASS VH 2.31 0.00325 PASS 16QAM/ 10MHz LCH TN VL -1.58 -0.00224 PASS VN -0.26 -0.00037 PASS VH 0.57 0.00081 PASS MCH TN VL 2.26 0.00319 PASS VN -0.17 -0.00024 PASS VH 2.26 0.00319 PASS HCH TN VL -0.39 -0.00055 PASS VN 1.66 0.00233 PASS VH 3.12 0.00439 PASS Test Band Test mode Test Channel Test Temp. Test Volt. Freq. Error [Hz] Freq. vs. rated [ppm] Verdict CatM1 band13 QPSK/ 10MHz LCH TN VL / / / VN / / / VH / / / MCH TN VL 2.87 0.00367 PASS VN -0.07 -0.00009 PASS VH 2.37 0.00303 PASS HCH TN VL / / / VN / / / VH / / / 16QAM/ LCH TN VL / / / 10MHz VN / / / VH / / / MCH TN VL 1.83 0.00234 PASS VN -0.53 -0.00068 PASS VH 1.89 0.00242 PASS HCH TN VL / / / VN / / / VH / / / Test Band Test mode Test Channel Test Volt. Test Temp. Freq. Error [Hz] Freq. vs. rated [ppm] Verdict CatM1 band2 QPSK/ 20MHz LCH VN -3 0 1.57 0.00084 PASS -20 1.58 0.00085 PASS -10 -0.27 -0.00015 PASS 0 1.36 0.00073 PASS 10 0.92 0.00049 PASS 20 0.98 0.00053 PASS 30 2.15 0.00116 PASS 40 1.94 0.00104 PASS 50 1.12 0.00060 PASS MCH VN -3 0 -1.21 -0.00064 PASS -20 -1.22 -0.00065 PASS -10 -3 -0.00160 PASS 0 -1.41 -0.00075 PASS 10 -2.54 -0.00135 PASS 20 1.34 0.00071 PASS 30 4.12 0.00219 PASS 40 -1.16 -0.00062 PASS 50 -0.44 -0.00023 PASS HCH VN -3 0 0.93 0.00049 PASS -20 0.92 0.00048 PASS -10 -0.07 -0.00004 PASS 0 0.97 0.00051 PASS 10 -1.05 -0.00055 PASS 20 1.06 0.00056 PASS 30 0.91 0.00048 PASS 40 -0.81 -0.00043 PASS 50 -2.05 -0.00108 PASS Test Band Test mode Test Channel Test Volt. Test Temp. Freq. Error [Hz] Freq. vs. rated [ppm] Verdict CatM1 band2 16QAM/ 20MHz LCH VN -3 0 1.19 0.00064 PASS -20 1.2 0.00065 PASS -10 -0.65 -0.00035 PASS 0 0.69 0.00037 PASS 10 1.05 0.00056 PASS 20 0.64 0.00034 PASS 30 1.77 0.00095 PASS 40 1.56 0.00084 PASS 50 1.6 0.00086 PASS MCH VN -3 0 -1.59 -0.00085 PASS -20 -1.6 -0.00085 PASS -10 -0.89 -0.00047 PASS 0 -1.79 -0.00095 PASS 10 -2.92 -0.00155 PASS 20 0.96 0.00051 PASS 30 0.97 0.00052 PASS 40 -1.54 -0.00082 PASS 50 -0.82 -0.00044 PASS HCH VN -3 0 0.8 0.00042 PASS -20 0.87 0.00046 PASS -10 -0.45 -0.00024 PASS 0 0.79 0.00042 PASS 10 -1.43 -0.00075 PASS 20 1.08 0.00057 PASS 30 0.53 0.00028 PASS 40 -1.19 -0.00063 PASS 50 -2.43 -0.00128 PASS Test Band Test mode Test Channel Test Volt. Test Temp. Freq. Error [Hz] Freq. vs. rated [ppm] Verdict CatM1 band4 QPSK/ 20MHz LCH VN -3 0 1.27 0.00074 PASS -20 1.28 0.00074 PASS -10 0.41 0.00024 PASS 0 1.1 0.00064 PASS 10 1.49 0.00087 PASS 20 1.36 0.00079 PASS 30 1.9 0.00110 PASS 40 1.41 0.00082 PASS 50 1.56 0.00091 PASS MCH VN -3 0 -2.1 -0.00121 PASS -20 -2.1 -0.00121 PASS -10 -1.24 -0.00072 PASS 0 -1.7 -0.00098 PASS 10 -0.94 -0.00054 PASS 20 -2.36 -0.00136 PASS 30 -1.24 -0.00072 PASS 40 -0.89 -0.00051 PASS 50 -0.94 -0.00054 PASS HCH VN -3 0 2.32 0.00133 PASS -20 2.31 0.00132 PASS -10 0.24 0.00014 PASS 0 1.25 0.00072 PASS 10 -1.16 -0.00066 PASS 20 0.36 0.00021 PASS 30 1.18 0.00068 PASS 40 -0.95 -0.00054 PASS 50 -0.69 -0.00040 PASS Test Band Test mode Test Channel Test Volt. Test Temp. Freq. Error [Hz] Freq. vs. rated [ppm] Verdict CatM1 band4 16QAM/ 20MHz LCH VN -3 0 2.29 0.00133 PASS -20 2.28 0.00133 PASS -10 0.43 0.00025 PASS 0 1.06 0.00062 PASS 10 1.62 0.00094 PASS 20 1.68 0.00098 PASS 30 0.85 0.00049 PASS 40 1.64 0.00095 PASS 50 1.82 0.00106 PASS MCH VN -3 0 -0.51 -0.00029 PASS -20 -0.52 -0.00030 PASS -10 -2.3 -0.00133 PASS 0 0.29 0.00017 PASS 10 -1.84 -0.00106 PASS 20 2.04 0.00118 PASS 30 0.82 0.00047 PASS 40 -0.46 -0.00027 PASS 50 0.26 0.00015 PASS HCH VN -3 0 1.61 0.00092 PASS -20 1.62 0.00093 PASS -10 0.63 0.00036 PASS 0 1.67 0.00096 PASS 10 -0.35 -0.00020 PASS 20 1.76 0.00101 PASS 30 1.61 0.00092 PASS 40 -0. 11 -0.00006 PASS 50 -1.35 -0.00077 PASS Test Band Test mode Test Channel Test Volt. Test Temp. Freq. Error [Hz] Freq. vs. rated [ppm] Verdict CatM1 band12 QPSK/ 10MHz LCH VN -3 0 1.6 0.00227 PASS -20 1.59 0.00226 PASS -10 0.72 0.00102 PASS 0 4.41 0.00626 PASS 10 3.8 0.00540 PASS 20 3.67 0.00521 PASS 30 2.21 0.00314 PASS 40 1.72 0.00244 PASS 50 1.87 0.00266 PASS MCH VN -3 0 -2.78 -0.00393 PASS -20 -2.79 -0.00394 PASS -10 -3.93 -0.00555 PASS 0 -0.39 -0.00055 PASS 10 -3.63 -0.00513 PASS 20 -2.05 -0.00290 PASS 30 -0.93 -0.00131 PASS 40 -3.58 -0.00506 PASS 50 -2.63 -0.00372 PASS HCH VN -3 0 2.63 0.00370 PASS -20 2.62 0.00368 PASS -10 0.55 0.00077 PASS 0 3.56 0.00501 PASS 10 -0.85 -0.00120 PASS 20 4.67 0.00657 PASS 30 1.49 0.00210 PASS 40 -0.64 -0.00090 PASS 50 -3.38 -0.00475 PASS Test Band Test mode Test Channel Test Volt. Test Temp. Freq. Error [Hz] Freq. vs. rated [ppm] Verdict CatM1 band12 16QAM/ 10MHz LC…
Text truncated - open the document above for the full version.
1. Effective (Isotropic) Radiated Power Output Data 1.1 Test Result Test Band: LTE CatM1 B2 _ 1.4MHz Bandwidth Modulation RB Allocation Conducted Power (dBm) Antenna gain EIRP(dBm) Limit (dBm) Verdict Size Offset LCH MCH HCH (dBd) (dBi) LCH MCH HCH QPSK 1 0 22.82 22.72 22.92 / 2.96 25.78 25.68 25.88 33.01 PASS 2 22.68 22.69 22.91 / 2.96 25.64 25.65 25.87 33.01 PASS 5 22.63 22.7 22.85 / 2.96 25.59 25.66 25.81 33.01 PASS 3 0 22.64 22.63 22.81 / 2.96 25.6 25.59 25.77 33.01 PASS 2 22.51 22.63 22.85 / 2.96 25.47 25.59 25.81 33.01 PASS 3 22.45 22.63 22.69 / 2.96 25.41 25.59 25.65 33.01 PASS 6 0 21.63 21.72 21.98 / 2.96 24.59 24.68 24.94 33.01 PASS 16QAM 1 21.77 21.91 22.24 / 2.96 24.73 24.87 25.2 33.01 PASS 2 21.61 21.91 22.41 / 2.96 24.57 24.87 25.37 33.01 PASS 5 21.43 21.8 22.44 / 2.96 24.39 24.76 25.4 33.01 PASS 3 0 21.4 21.84 21.73 / 2.96 24.36 24.8 24.69 33.01 PASS 2 21.57 21.86 21.8 / 2.96 24.53 24.82 24.76 33.01 PASS 3 21.53 21.78 21.8 / 2.96 24.49 24.74 24.76 33.01 PASS 6 0 21.14 20.87 20.89 / 2.96 24.1 23.83 23.85 33.01 PASS Test Band: LTE CatM1 B2 _ 3MHz Bandwidth Modulation RB Allocation Conducted Power (dBm) Antenna gain EIRP(dBm) Limit (dBm) Verdict Size Offset LCH MCH HCH (dBd) (dBi) LCH MCH HCH QPSK 1 0 22.98 22.85 22.99 / 2.96 25.94 25.81 25.95 33.01 PASS 2 22.74 22.86 22.8 / 2.96 25.7 25.82 25.76 33.01 PASS 5 22.79 22.75 22.78 / 2.96 25.75 25.71 25.74 33.01 PASS 3 0 21.63 21.65 21.85 / 2.96 24.59 24.61 24.81 33.01 PASS 2 21.41 21.68 21.87 / 2.96 24.37 24.64 24.83 33.01 PASS 3 21.38 21.6 21.71 / 2.96 24.34 24.56 24.67 33.01 PASS 6 0 21.58 21.71 22 / 2.96 24.54 24.67 24.96 33.01 PASS 16QAM 1 22.14 21.91 21.85 / 2.96 25.1 24.87 24.81 33.01 PASS 2 21.81 21.83 21…
Text truncated - open the document above for the full version.
Fuyong Lab Xinlong Techno Park Fengtang Road · Shenzhen · China
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 21 | 22H | 1.85 GHz - 1.91 GHz | 736.20 mW | 253KG7W | 2.5 ppm |
Body Fat Scale
Equipment Class
PCB - PCS Licensed TransmitterBlood Pressure monitor
Equipment Class
DTS - Digital Transmission System
Blood Pressure monitor
Equipment Class
PCB - PCS Licensed Transmitter
Blood pressure monitor
Equipment Class
PCB - PCS Licensed Transmitter
Blood pressure monitor
Equipment Class
DTS - Digital Transmission System