User Manual Version:A/0 Blood Pressure Monitor Model: TMB-2276-BT Arm Type Thank you very much for selecting TRANSTEK Blood Pressure Monitor TMB-2276-BT. Please read the user manual carefully and thoroughtly so as to ensure the safe usage of this product, Keep the manual well for further reference in case you have problems. Guangdong Transtek Medical Electronics Co., Ltd. Zone A, No.105 ,Dongli Road, Torch Development District, 528437 Zhongshan,Guangdong,China 1 Table of Contents CATALOGUE INTRODUCTION...................................................................................................................2 General Description Indications for Use Measurement Principle Receiving and Inspecting your Monitor Safety Information LCD Display Signal Monitor Components List BEFORE YOU START...........................................................................................................8 Choice of Power Supply Installing and Replacing the Batteries Setting Date, Time and Voice Pair a smart device with the monitor Select the User MEASUREMENT..................................................................................................................15 Applying the cuff Start the Measurement DATA MANAGEMENT..........................................................................................................19 Recall the Records Delete the Records INFORMATION FOR USER................................................................................................22 Tips for measurement Maintenances ABOUT BLOOD PRESSURE..............................................................................................24 What are systolic pressure and diastolic pressure? What is the standard blood pressure classification? Irregular pulse rate detector Why does my blood pressure fluctuate throughout the day? Why do I get a different blood pressure at home compared to the hospital? Is the result the same if measuring on the right arm? TROUBLESHOOTING........................................................................................................26 SPECIFICATIONS..............................................................................................................27 AUTHORIZED COMPONENTS .........................................................................................28 CONTACT INFORMATION.................................................................................................28 EMC GUIDANCE................................................................................................................29 FCC STATEMENT...............................................................................................................33 INTRODUCTIONINTRODUCTION 2 3 Thank you for selecting TRANSTEK blood pressure monitor (TMB-2276-BT). The monitor features blood pressure measurement, pulse rate measurement and the result storage. The warranty period is two years. Readings taken by the TMB-2276-BT are equivalent to those obtained by a trained observer using the cuff and stethoscope auscultation method. This manual contains important safety and care information, and provides step by step instructions for using the product. Read the manual thoroughly before using the product. Features: 2 × 199 memory storage, Guest mode available General Description Up-to-date measuring-during-inflation technology 60 mm×71.5 mm Digital LCD display with white backlight Indications for Use Measurement Principle This product uses the Oscillometric Measuring method to detect blood pressure. Before every measurement, the unit establishes a “zero pressure” equivalent to the atmospheric pressure. Then it starts inflating the arm cuff, meanwhile, the unit detects pressure oscillations generated by beat-to-beat pulsatile, which is used to determine the systolic and diastolic pressure, and also pulse rate. Check that the device packaging has not been tampered with and make sure that all contents are present. Before use, ensure that there is no visible damage to the device or accessories and that all packaging material has been removed. If you have any doubts, do not use the device and contact your retailer or the specified Customer Services address. Receiving and Inspecting your Monitor Safety Information The signs below might be in the user manual, labeling or other component. They are the requirement of standard and using. MR Unsafe To identify an item which poses unacceptable risks to the patient, medical staff or other persons within the MR environment. Manufacturer Serial Number Type BF applied part Direct Current The symbol indicates that the product should not be discarded as unsorted waste but must be sent to separate collection facilities for recovery and recycling. Recyclable Caution Indicates that caution is necessary when operating the device or control close to where the symbol is placed, or that the current situation needs operator awareness or operator action in order to avoid undesirable consequences. Refer to instruction manual/booklet To signify that the instruction manual/ booklet must be read. Note: The background color of the symbol is blue Date of manufacture For indoor use only Class II Equipment This Blood Pressure Monitor is a digital monitor intended for use in measuring blood pressure and pulse rate with arm circumference ranging from 16cm to 36cm (about 6 ̋-14 ̋), 22cm to 32cm (about 8¾ ̋-12½ ̋), 22cm to 42cm (about 8¾ ̋-16½ ̋) or 22cm to 45cm (about 8¾ ̋-17¾ ̋). It is intended for at least 3 years of age or older and indoor use only. ¹⁄3 ¹⁄5 INTRODUCTION INTRODUCTION 4 5 Precaution * This device is intended for indoor, home use and is not intended for self-use in public areas. * This device is portable, but it is not intended for use during patient transport. * This device is not suitable for continuous monitoring during medical emergencies or operations. * This device is intended for non-invasive measuring and monitoring of arterial blood pressure. It is not intend…
Text truncated - open the document above for the full version.
ApplicantDeclaration QSF27-14-04Rev1.0Rev.Feb6,2023Page 1 of 2 OriginalIssue:Jan.4,2021 SGSNorthAmericaInc. 620OldPeachtreeRoad SUITE100 Suwanee,Georgia30024 UnitedStates ApplicantLegalBusinessName GuangdongTranstekMedicalElectronicsCo.,Ltd Address ZoneA,No.105,DongliRoadTorchDevelopmentDistrictZhongshan,Guangdong,528437, China GranteeCode OU9 FCCID OU9TMB2276BT AuthorizedContactName JerryFan ContactEmail [email protected] ContactPhone +86-760-85166220 I,theundersigned,certifythatIamanauthorizedsignatoryfortheApplicantandthereforedeclare; a)inaccordancewith47CFR2.911(d),allofthestatementshereinandtheexhibitsattachedheretoaretrueandcorrecttothebestofmy knowledgeandbelief. b)inacceptingaGrantofEquipmentAuthorizationissuedbyaTCB,undertheauthorityoftheFCC,asaresultoftherepresentationsmadein thisapplication,theApplicantisresponsiblefor: (1)labelingtheequipmentwiththeexactFCCIDasspecifiedinthisapplication, (2)compliancestatementlabelingpursuanttotheapplicablerules, (3)complianceoftheequipmentwiththeapplicabletechnicalrules, c)iftheApplicantisnottheactualmanufactureroftheequipment,appropriatearrangementshavebeenmadewiththemanufacturertoensure thatproductionunitsofthisequipmentwillcontinuetocomplywiththeFCC’stechnicalrequirements. d)inaccordancewith47CFR2.909andKDB394321,theApplicanthasread,understoodandagreestoacceptthattheyaretheresponsible partyandagreetoabidebytheirresponsibilitiesasspecifiedunder47CFR2.909andKDB394321. e)inaccordancewithISO17065,FCCKDB641163,FCCKDB610077,KDB394321andRSP-100,theApplicanthasread,understood,accepts andagreestoabidebythepostmarketsurveillancerequirements. (1)theApplicantunderstands,acceptsandagreesthatasamplemayberequestedforsurveillancetesting. (2)theApplicantshallmakeprovisionstoalwayshaveaproductionsampleavailableuponrequestbySGS,FCCand/orISED. (3)theApplicantshall,uponrequestbySGS,attheApplicant’sexpense,provideaproductionsampleoftherequestedproducttoSGS, FCCand/orISEDasinstructed.Thesampleshallincludeallsupportdevices,cables,software,accessoriesorotherhardwareor softwarerequiredforevaluation,review,certificationandauditsurveillanceofproductscertifiedbySGS. f)neithertheApplicantnoranypartytotheapplicationissubjecttoadenialofFederalbenefits,thatincludesFCCbenefits,pursuanttoSection 5301oftheAnti-DrugAbuseActof1988,21U.S.C.§862becauseofaconvictionforpossessionordistributionofacontrolledsubstance.See 47CFR1.2002(b)forthedefinitionofa“party”forthesepurposes. g)theApplicanthasread,understood,acceptsandagreestoabidebytheSGSNorthAmerica,Inc.(TCB)termsandconditions. LinktoCFRs:https://www.fcc.gov/wireless/bureau-divisions/technologies-systems-and-innovation-division/rules-regulations-title-47 LinktoKDBs:https://apps.fcc.gov/oetcf/kdb/index.cfm LinktoRSP-100:https://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf01130.html LinktotheCoveredList:CoveredList [GuangdongTranstekMedicalElectronicsCo.,Ltd](“theapplicant”)certifiesthattheequipmentforwhichauthorizationissoughtisnot “covered”equipmentprohibitedfromreceivinganequipmentauthorizationpursuanttosection2.903oftheFCCrules. [GuangdongTranstekMedicalElectronicsCo.,Ltd](“theapplicant”)certifiesthat,asofthedateofthefilingoftheapplication,the applicant[isnot]identifiedontheCoveredlist,establishedpursuantto§1.50002,asanentityproducing“covered”equipment. ApplicantSignature: Date:2023-05-24 PrintName: JerryFan Title: RAManager *NOTE:ThisdeclarationcannotbesignedbyanAgent,itshallbesignedbyanauthorizedpersonlistedintheFCCdatabase ApplicantDeclaration QSF27-14-04Rev1.0Rev.Feb6,2023Page 2 of 2 OriginalIssue:Jan.4,2021 SGSNorthAmericaInc. 620OldPeachtreeRoad SUITE100 Suwanee,Georgia30024 UnitedStates
UNITEDSTATESDESIGNATEDAGENTLETTER Date:20230524 TO:FederalCommunicationCommission EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MID21046 ApplicantU.S.designatedagent CompanyName:GuangdongTranstekMedical ElectronicsCo.,Ltd CompanyName: MIOLABSINC. GranteeCode:OU9FRN: ContactName: 0032569972 ContactName:JerryFanAddress: 4500GreatAmericaPkwy Suite1023 Address:ZoneA,No.105,Dongli RoadTorchDevelopment District City/Province/Zip: 95054 City/Province/Zip:Zhongshan, Guangdong/528437 Telephone: 1572866685ext.28(301- 910-0529) Telephone:+86-760-85166220Fax: / Fax:+86-760-86742877Email: [email protected] Email:[email protected] ApplicableEquipment:FCCID:<OU9TMB2276BT> ATTN:DirectorofCertification: We,<GuangdongTranstekMedicalElectronicsCo.,Ltd>and<MIOLABSINC.>understandand acknowledgetheapplicantsconsentandthedesignatedagent’sobligationtoacceptserviceofprocessin theUnitedStatesformattersrelatedtotheapplicableequipment,andatthephysicalU.S.addressande- mailofthedesignatedagentlistedabove. We,<GuangdongTranstekMedicalElectronicsCo.,Ltd>and<MIOLABSINC.>acknowledgethe applicant’sacceptanceofitsobligationtomaintainanagentforserviceofprocessintheUnitedStatesfor nolessthanoneyearaftereitherthegranteehaspermanentlyterminatedallmarketingandimportation oftheapplicableequipmentwithintheU.S.,ortheconclusionofanyCommission-relatedadministrative orjudicialproceedinginvolvingtheequipment,whicheverislater. ApplicantU.S.designatedagent Name(Printed):JerryFanName (Printed) :ChengcenSu Title:RAManager Title:SalesManager Signature:Signature:
GuangdongTranstekMedicalElectronicsCo.,Ltd Date:2023-05-24 TO:FederalCommunicationCommission EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MID21046 Regarding:FCCID:OU9TMB2276BT Towhomitmayconcern: We,theundersigned,herebyauthorizeSGS-CSTCStandardsTechnicalServicesCo.,Ltd.toactonour behalfinallmannersrelatingtoapplicationforequipmentauthorizationwithrespecttotheFCCIDabove, includingsigningofalldocumentsrelatingtothesematters.Anyandallactscarriedoutbytheagenton ourbehalfshallhavethesameeffectasactsofourown. We,theundersigned,herebycertifythatwearenotsubjecttoadenialoffederalbenefits,thatincludes FCCbenefits,pursuanttoSection5301oftheAnti-DrugAbuseActof1988,21U.S.C.853(a). Whereouragentsignstheapplicationforcertificationonourbehalf,Iacknowledgethatallresponsibility forcomplyingwiththetermsandconditionsforCertification,asspecifiedbySGSNorthAmerica,Inc.,still resideswithGuangdongTranstekMedicalElectronicsCo.,Ltd. Thisauthorizationisvaliduntilfurtherwrittennoticefromtheapplicant. Sincerely, PrintName:JerryFanTitle:RAManager Signature: OnbehalfofCompany:GuangdongTranstekMedicalElectronicsCo.,Ltd Telephone:+86-760-85166220 E-mail:[email protected]
GuangdongTranstekMedicalElectronicsCo.,Ltd TO:FederalCommunicationCommission EquipmentAuthorizationBranch 7435OaklandMillsRoad Columbia,MID21046 Regarding:ConfidentialityRequestregardingapplicationforFCCID:OU9TMB2276BT LONGTERMCONFIDENTIALITY Pursuantto47CFRSection0.459and0.457ofthecommission’srules,theapplicantherebyrequest confidentialtreatmentofthedocumentslistedbelow,associatedwiththecertificationapplication referencedabove. Schematic(s) BlockDiagrams OperationalDescriptions Thedocumentsabovecontainproprietaryinformationnotreleasedtothepublic.Publicdisclosureofthis informationmayproveharmfultothebusinessoftheapplicant. SHORTTERMCONFIDENTIALITY Additionally,theapplicantrequeststhefollowingdocumentsbeheldconfidentialuntilthedeviceis marketedor180daysfromthegrantdate,whicheverisless.Ifthedeviceismarketedwithin aforementioneddaysoftheGrantDate,theapplicantwillnotifytheTCBperFCCKDB726920D01 ConfidentialityRequestProcedures. ExternalPhotos InternalPhotos TestSetupPhotos Usermanual(s) Sincerely, PrintName:JerryFanTitle:RAManager Signature: OnbehalfofCompany:GuangdongTranstekMedicalElectronicsCo.,Ltd Telephone:+86-760-85166220 E-mail:[email protected]
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A02 Rev.A/0 Page: 1 of 5 External Photos for SZCR2305001527ME FCC ID: OU9TMB2276BT SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A02 Rev.A/0 Page: 2 of 5 EUT Constructional Details (EUT Photos) SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A02 Rev.A/0 Page: 3 of 5 Label Location SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A02 Rev.A/0 Page: 4 of 5 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A02 Rev.A/0 Page: 5 of 5
45mm 20mm Model: TMB-2276-BT AC adaptor powered mode: 5V 1AOptional! (Please use the AC adaptor which authorized by the manufacturer!) Rating:Battery powered mode: 4xAAA batteries, 6V Optional! IP Classification:IP21 Guangdong Transtek Medical Electronics Co., Ltd. Zone A, No.105 ,Dongli Road, Torch Development District, 528437 Zhongshan,Guangdong,China 2023-02 (21)2EB1235230200001 (01)XXXXXXXXXXXXXX GS1 Datamatrix (UDI) SN FCC ID: OU9TMB2276BT
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A03 Rev.A/0 Page: 1 of 3 Internal Photos for SZCR2305001527ME FCC ID: OU9TMB2276BT SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A03 Rev.A/0 Page: 2 of 3 EUT Constructional Details (EUT Photos) SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-A03 Rev.A/0 Page: 3 of 3 - End of the Appendix - Antenna
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230500152703 Page: 1 of 10 Keny Xu EMC Laboratory Manager 1 Cover page RF Exposure Report Application No.: SZCR2305001527ME Applicant: Guangdong Transtek Medical Electronics Co., Ltd Address of Applicant: Zone A, No.105, Dongli Road, Torch Development District, 528437 Zhongshan, Guangdong, China. Manufacturer: Guangdong Transtek Medical Electronics Co., Ltd Address of Manufacturer: Zone A, No.105, Dongli Road, Torch Development District, 528437 Zhongshan, Guangdong, China. Factory: Guangdong Transtek Medical Electronics Co., Ltd Address of Factory: Zone A, No.105, Dongli Road, Torch Development District, 528437 Zhongshan, Guangdong, China. Equipment Under Test (EUT): EUT Name: Blood pressure monitor Model No.: TMB-2276-BT, TMB-2276-B Please refer to section 4 of this report which indicates which model was actually tested and which were electrically identical. FCC ID: OU9TMB2276BT Standards: FCC Rules 47 CFR §2.1093 KDB 447498 D04 interim General RF Exposure Guidance v01 Date of Receipt: 2023-05-19 Date of Test: 2023-05-23 to 2023-05-26 Date of Issue: 2023-06-06 Test Result : Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230500152703 Page: 2 of 10 2 Version Revision Record Version Chapter Date Modifier Remark 01 2023-06-06 Original Authorized for issue by: Edison Li/Project Engineer Eric Fu/Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230500152703 Page: 3 of 10 3 Contents Page 1 COVER PAGE ........................................................................................................................................ 1 2 VERSION ................................................................................................................................................ 2 3 CONTENTS ............................................................................................................................................ 3 4 GENERAL INFORMATION ..................................................................................................................... 4 4.1 GENERAL DESCRIPTION OF E.U.T. ...................................................................................................... 4 4.2 DETAILS OF EUT ............................................................................................................................... 5 4.3 SEPARATION DISTANCE...................................................................................................................... 5 4.4 TEST LOCATION ................................................................................................................................ 6 4.5 TEST FACILITY .................................................................................................................................. 6 4.6 DEVIATION FROM STANDARDS ............................................................................................................ 6 4.7 ABNORMALITIES FROM STANDARD CONDITIONS .................................................................................... 6 4.8 OTHER INFORMATION REQUESTED BY THE CUSTOMER .......................................................................... 6 5 FCC RADIOFREQUENCY RADIATION EXPOSURE LIMITS .................................................................. 7 5.1 BLANKET 1 MW BLANKET EXEMPTION.................................................................................................. 7 5.2 MPE-BASED EXEMPTION.................................................................................................................... 7 5.3 SAR-BASED EXEMPTION .................................................................................................................... 8 6 MEASUREMENT AND CALCULATION ................................................................................................ 10 6.1 MAXIMUM TRANSMIT POWER ............................................................................................................. 10 6.2 RF EXPOSURE CALCULATION ........................................................................................................... 10 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230500152703 Page: 4 of 10 4 General Information 4.1 General Description of E.U.T. Product Type: Portable device Mobile device Fixed device Declaration of EUT Family Grouping: Model No.: TMB-2276-BT, TMB-2276-B Only the model TMB-2276-BT was tested, since according to the declaration from the applicant, the electrical circuit design, PCB layout, components used and internal wiring and functions were identical for the above models, with only difference on model No., shape and colour. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230500152703 Page: 5 of 10 4.2 Details of EUT Power supply: AC Adapter Model: BLJ06L050100U-U Input: AC 100-240V, 50/60Hz, 0.2A Max Output: DC 5.0V, 1.0A DC 6V(4 x AAA batteries) Cable(s): Type-C cable:84cm unshielded Operation Frequency: 2402MHz to 2480MHz Bluetooth Version: V5.0 Modulation Type: GFSK Number of Channels: 40 Channel Spacing: 2MHz Data rate: 1Mpps Antenna Type: PCB Antenna Antenna Gain: 0.43dBi Remark:The information in this section is provided by the applicant or manufacturer, SGS is not liable to the accuracy, suitability, reliability or/and integrity of the information. 4.3 Separation Distance Minimum test separation distance: 5mm Remark: This minimum test separation distance is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposur…
Text truncated - open the document above for the full version.
Testing Report Product Name: TMB-2276-BT, TMB-2276-B Issue Date: 2023.6. 28 Engineer: Date 2023.6.28 Auditor: Date 2023.6.28 Approve Date 2023.6.28 Content 1. General Information 1.1 General information of testing institutions 1.2 Test equipment 1.3 Test environment 1.4 Statement 2. Sample Information 2.1 Client information 2.2 Description of EUT(S) 2.3 EUT appearance 2.4 DUT setup photo of free space OTA testing 3. Test Result 3.1 Test standard 3.2 Test uncertainty 3.3 Test data 3.3.1 S1l parameters 3.3.2 VSWR 3.3.3 Typical free space efficiency and gain 3.3.4 Typical free space radiation patter 1. General Information 1. 1 General information of testing institutions Name Shenzhen DBT Communication Device Co., Ltd Address Rm505, 8th building, Yungu 2nd period, pingshan No.1 Road, Xili Town,Nanshan District, ShenZhen , China Tel 0755-83763273 E-mail [email protected] Equipment 1. RayZone 1800 2. Keysight E5071C 1.2 Test equipment Satimo E5071C Cmw500 8960 Model No. Manufacturer Calibration date Next calibration date Satimo RFI-LAB-RF-A00 2022.11 13 2023.11 13 Cmw500 ROHDE&SCHWAR 8960 Agilent E5071C Agilent 1.3 Test environment Temperature 25. 0*C Humidity 59%RH Pressure 100.12kPa 1.4 Statement (1) The test results in the report are only applicable to the tested samples and the tested samples work under the environment described in the report (2) Any objection to this report shall be raised 30 days after formal confirmation of the report. (3) The report is invalid without the signature of the auditor and approver. 2.Sample Information 2.1 Client information Name Guangdong Transtek Medical Electronics Co., Ltd Address Zone A, No.105, Dongli Road, Torch Development District, 528437 Zhongshan, Guangdong, China. Contacts Tel E-mail 2.2 Description of EUT(S) Product Name 2.4 GHz Antenna Antenna Size 13.5*7.5mm Antenna Type PCB Test Item VSWR; Gain; Efficiency; Radiation pattern Frequency Range 2402-2480MHz Received Date 2023.6.28 Test Date 2023.6.28 Remark i 2.3 EUT appearance See test report 2.4 DUT setup photo of free space OTA testing Zenith is at Theta » 0° 3.Test Results 3.1 Test standard Name Parameter Method Standard no. Mobile Communication antenna VSWR Generic specification for antennas used in the mobile communications GB/T 9410-2008 Antenna gain Radiation pattern Antenna Radiation efficiency IEEE Standard Test Procedures for Antennas ANSI/IEEE Std 149-1979 3.2 Test uncertainty The uncertainty was calculated on the basis of the GUM published by ISO. using the inclusion factor of K=2 and the 95% confidence level to express the extended uncertainty. Item Uncertainty VSWR ±0.3 Antenna gain + ldB Radiation efficiency ±10% 3.3 Test data 3.3.1 S1l parameters 3.3.2 VSWR Frequency/MHz 2400 2450 2500 VSWR 1.7198 2.0870 2.7562 3.3.3 Typical free space efficiency and gain Frequency MHz 2400 2410 2420 2430 2440 2450 2460 2470 2480 2490 2500 Peak Gain dBi 0.29 0.27 0.15 0.18 0.15 -0.26 -0.02 -0.17 0.26 -0.62 0.43 Efficiency % 41.33 41.62 40.83 41.34 41.15 41.13 40.01 40.06 43.34 44.13 44.01 3.3.4 Typical free space radiation p atter
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230500152702 Page: 1 of 58 Keny Xu EMC Laboratory Manager TEST REPORT Application No.: SZCR2305001527ME Applicant: Guangdong Transtek Medical Electronics Co., Ltd Address of Applicant: Zone A, No.105, Dongli Road, Torch Development District, 528437 Zhongshan, Guangdong, China. Manufacturer: Guangdong Transtek Medical Electronics Co., Ltd Address of Manufacturer: Zone A, No.105, Dongli Road, Torch Development District, 528437 Zhongshan, Guangdong, China. Factory: Guangdong Transtek Medical Electronics Co., Ltd Address of Factory: Zone A, No.105, Dongli Road, Torch Development District, 528437 Zhongshan, Guangdong, China. Equipment Under Test (EUT): EUT Name: Blood pressure monitor Model No.: TMB-2276-BT, TMB-2276-B Please refer to section 2 of this report which indicates which model was actually tested and which were electrically identical. FCC ID: OU9TMB2276BT Standard(s) : 47 CFR Part 15, Subpart C 15.247 Date of Receipt: 2023-05-19 Date of Test: 2023-05-23 to 2023-05-26 Date of Issue: 2023-06-06 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230500152702 Page: 2 of 58 Revision Record Version Chapter Date Modifier Remark 01 2023-06-06 Original Authorized for issue by: Edison Li/Project Engineer Eric Fu/Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230500152702 Page: 3 of 58 2 Test Summary Radio Spectrum Technical Requirement Item Standard Method Requirement Result Antenna Requirement 47 CFR Part 15, Subpart C 15.247 N/A 47 CFR Part 15, Subpart C 15.203 & 15.247(b)(4) Pass Radio Spectrum Matter Part Item Standard Method Requirement Result Conducted Emissions at AC Power Line (150kHz-30MHz) 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 6.2 47 CFR Part 15, Subpart C 15.207 Pass Conducted Peak Output Power ANSI C63.10 (2013) Section 11.9.1 47 CFR Part 15, Subpart C 15.247(b)(3) Pass Minimum 6dB Bandwidth ANSI C63.10 (2013) Section 11.8.1 47 CFR Part 15, Subpart C 15.247a(2) Pass Power Spectrum Density ANSI C63.10 (2013) Section 11.10.2 47 CFR Part 15, Subpart C 15.247(e) Pass Conducted Band Edges Measurement ANSI C63.10 (2013) Section 11.13.3.2 47 CFR Part 15, Subpart C 15.247(d) Pass Conducted Spurious Emissions ANSI C63.10 (2013) Section 11.11 47 CFR Part 15, Subpart C 15.247(d) Pass Radiated Emissions which fall in the restricted bands ANSI C63.10 (2013) Section 6.10.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions Below 1GHz ANSI C63.10 (2013) Section 6.4,6.5 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Radiated Spurious Emissions Above 1GHz ANSI C63.10 (2013) Section 6.6 47 CFR Part 15, Subpart C 15.205 & 15.209 Pass Declaration of EUT Family Grouping: Model No.: TMB-2276-BT, TMB-2276-B Only the model TMB-2276-BT was tested, since according to the declaration from the applicant, the electrical circuit design, PCB layout, components used and internal wiring and functions were identical for the above models, with only difference on model No., shape and colour. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch SZEMC-TRF-01 Rev. A/0 Aug01,2022 Report No.: SZCR230500152702 Page: 4 of 58 3 Contents Page 1 Cover Page ......................................................................................................................................... 1 2 Test Summary ..................................................................................................................................... 3 3 Contents ............................................................................................................................................. 4 4 General Information............................................................................................................................ 6 4.1 Details of E.U.T. ........................................................................................................................... 6 4.2 Description of Support Units ......................................................................................................... 6 4.3 Measurement Uncertainty ............................................................................................................ 7 4.4 Test Location ............................................................................................................................... 8 4.5 Test Facility .................................................................................................................................. 8 4.6 Deviation from Standards ............................................................................................................. 8 4.7 Abnormalities from Standard Conditions ....................................................................................... 8 5 Equipment List ................................................................................................................................... 9 6 Radio Spectrum Technical Requirement ..........................................................................................11 6.1 Antenna Requirement .................................................................................................................11 6.1.1 Test Requirement: ..................................................................................................................11 6.1.2 Conclusion ..............................................................................................................................11 7 Radio Spectrum Matter Test Results ........................................................................…
Text truncated - open the document above for the full version.
No.1 Workshop, M-10, Middle Section Science & Tech · Shenzhen · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 600.00 µW |
Body Fat Scale
Equipment Class
PCB - PCS Licensed TransmitterBlood Pressure monitor
Equipment Class
DTS - Digital Transmission System
Blood Pressure monitor
Equipment Class
PCB - PCS Licensed Transmitter
Blood pressure monitor
Equipment Class
PCB - PCS Licensed Transmitter
Blood pressure monitor
Equipment Class
DTS - Digital Transmission System