FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

ยฉ 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Magnetek/
  3. OUV900L8RX

OUV900L8RXControl Receiver

Magnetek
Control Receiver - FCC ID OUV900L8RX - Magnetek
Click to zoom

Application Details

Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
Date of Grant
Jan 27, 2000
Application Purpose
Original Equipment
Date of Application
Jan 13, 2000
Equipment Note
Control Receiver
Frequency Range
903.30000000 - 921.30000000
Company
Magnetek
Country
United States

Documents & Files

Select a file to view

Users Manual

โ†—

External Photos

โ†—

ID Label/Location Info

โ†—

Internal Photos

โ†—
โ†—
โ†—
โ†—

Schematics

โ†—

Test Report

โ†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

External Photos

EXTERNAL VIEW

Internal Photos

IINTERNAL VIEW

Internal Photos

INTERNAL โ€“ DAUGHTER BOARDS REMOVED

Internal Photos

DAUGHTER BOARD 1

Internal Photos

DAUGHTER BOARD 2

Schematics

SCHEMATICS

Test Report

NATIONAL CERTIFICATION LABORATORY 8370 Court Avenue, Suite B-1 Ellicott City MD 21043 (410) 461-5548 FCC REPORT OF RADIO INTERFERENCE for Enrange #5 Four Coins Drive Canonsburg, PA 15317 FCC ID: OUV900L8RX January 13, 2000 TABLE OF CONTENTS Application Form 731 Label Format 1.0 Introduction 1.1 Summary 2.0 Description of Equipment Under Test (EUT) 3.0Test Configuration 4.0 Conducted Emissions Scheme 5.0 Radiated Emissions Scheme TABLES Table 1.Support Equipment Table 2.Measurement Equipment EXHIBITS Exhibit 1.EUT Photographs Exhibit 2. User Manual Exhibit 3.Schematics NCL PROJ.# ENRANGE0529-RX FCC ID #: OUV900L8RX 2 1.0 Introduction This report has been prepared on behalf of Enrange to support the attached Application for Certification of a Part 15 Unintentional Radiator. The Equipment Under Test was the EnrangeLAG360RX Radio Receiver . Radio-Noise Emissions tests were performed according toANSI C63.4-1992 "Methods of Measurement of RFI from Low-Voltage Electronic Equipment in the Range of 9 KHz - 40 GHz" . The measuring equipment conforms to ANSI C63.2 Specifications for Electromagnetic Noise and Field Strength Instrumentation. Testing was performed at National Certification Laboratory in Ellicott City, MD. Site description and site attenuation data have been placed on file with the FCC's Sampling and Measurements Branch. FCC acceptance was granted on May 26, 1993. 1.1 Summary The EnrangeLAG360RX Radio Receivercomplies with the Part 15 Radio Limits for an Unintentional Radiator. 2.0 Description of Equipment Under Test (EUT) The EUT Features: FEATURES FREQUENCY LED Indicators 903.3-921.3 MHz Superheterodyne Design PCM Decoding Batttery Powered Only Solenoid Switching Function For Hydraulic Equipment External Whip Antenna FCC ID #: OUV900L8RX 2 3.0 Test Configuration The EUT was setup on the test table in a manner which follows the general guidelines of ANSI C63.4, Section 6 "General Operating Conditions and Configurations" . An RF signal generator was used to cohere the spectral components of the emissions, as prescribed in ANSI C63.4, Section 12.1.1.1. An output level of -20 dBm at 903 MHz (CW) was fed into a 10 inch whip antenna in order to create a field level sufficient to accomplish this. The EUT was configured in 3 orthogonal positions to determine the maximum RF level at each emission frequency. The data tables give the EUT postion designation that produces worst-case field strength, in an X, Y, Z system. This is described below: 4.0 Conducted Emissions Scheme The EUT is powered by battery only. FCC ID #: OUV900L8RX 3 5.0 Radiated Emissions Scheme The EUT was initially scanned in the frequency range 30 to 5000 MHz indoors, at a distance of 1 meter to determine its emissions profile. The EUT was then placed on an 80 cm high 1 X 1.5 meter non-conductive motorized turntable for radiated testing on the 3- meter open area test site. The emissions from the EUT are measured continuously at every azimuth by rotating the turntable. Waveguide horn and log periodic broadband antennas are mounted on an antenna mast to determine the height of maximum emissions. The height of the antenna is varied between 1 and 4 meters. Cables are varied in position to produce maximum emissions. Both the horizontal and vertical field components are measured. The output from the antenna is connected to the input of the spectrum analyzer. The detector function is set to QUASI-PEAK or AVG as required. The resolution bandwidth of the spectrum analyzer system is set at 120 kHz, for measurements in the range 30 MHz โ€“ 960 MHz, and 1 MHz for measurements in the range of 960 MHz โ€“ 5 GHz, with all post-detector filtering no less than 10 times the resolution bandwidth. All emissions within 20 dB of the limit are recorded in the data tables. To convert the spectrum analyzer reading into a quantified E-field level to allow comparison with the FCC limits, it is necessary to account for various calibration factors. These factors include cable loss (CL) and antenna factors (AF). The AF/CL in dB/m is algebraically added to the Spectrum Analyzer Voltage in db ฮผ Vto obtain the Radiated Electric Field in dB ฮผ V/m. This level is then compared with the FCC limit. Example: Spectrum Analyzer Volt: VdBuV Composite Factor: AF/CLdB/m Electric Field: EdB ฮผ V/m = VdB ฮผ V + AF/CLdB/m Linear Conversion: EuV/m = Antilog (EdB ฮผ V/m/20) FCC ID #: OUV900L8RX 4 FCC RADIATED EMISSIONS DATA CLIENT:ENRANGE EUT:LAG360RX TUNING FREQ.:921.3.00 MHZ 3-METER TEST (QP) (QP) FREQPOL SPEC A AF/CLAMPE-FIELDE-FIELDLIMIT MRGN MHz ANT EUTdBuVdB/mGAINdBuV/muV/muV/mdB 74.63 H X55.07.0-3032.039.8100.0-8.0 125.46 H X53.015.0-3038.079.4150.0-5.5 224.89 H X48.020.0-3038.079.4200.0-8.0 414.12 H Z43.019.0-3032.039.8200.0-14.0 503.26 V X44.020.0-3034.050.1200.0-12.0 545.65 V Y42.021.0-3033.044.7200.0-13.0 TEST ENGINEER __________________________DATE___________ STEVE DAYHOFF FCC ID #: OUV900L8RX 5 Table 1 Support Equipment MANUFACTURER FCC ID # SERIAL # N/A N/A None FCC ID #: OUV900L8RX 6 Table 2 Measurement Equipment Used The following equipment is used to perform measurements: EQUIPMENT SERIAL NUMBER Wavetek 2410A 1100 MHz Signal Generator 1362016 HP Model 8449B Preamplifier 12A533-A EMCO Model 3146 Log Periodic Antenna 1222 Solar 8012-50-R-24-BNC LISN 924867 Advantest Model R4131D Spectrum Analyzer 54378A EMCO Model 3115 Ridge Horn Antenna 1238 4 Meter Antenna Mast None Motorized Turntable None RG-233U 50 ohm coax Cable None

Contact Information

Applicant

Chris Dulin(Radio Product and Development Manager)
[email protected]724 746 3313Fax: 724 746 3379

Technical Contact

National Certification LabSteve l Dayhoff
[email protected]410 461 5548

8370 Court Ave., Suite B-1 ยท Ellicott City, Maryland ยท United States

Non-Technical Contact

National Certification LabSteve L Dayhoff
[email protected]410 461 5548

Test Firm

National Certification LaboratoryBrian Haghtalab
[email protected]410-461-5548Fax: 410-461-5548

Technical Specifications

#Rule PartsFrequency RangePower Output
115B903.3 MHz - 921.3 MHz-

Other Applications from Magnetek

TR120 Remote TX - FCC ID OUV01GTRF - Magnetek
OUV01GTRF

TR120 Remote TX

Jun 13, 2001

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Machine Remote Control TX - FCC ID OUV900L8TX - Magnetek
OUV900L8TX

Machine Remote Control TX

Feb 10, 2000

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter