Rhein Tech Laboratories Client: M/A-COM, Inc. 360 Herndon Parkway Model: P5400 VHF Portable Radio Suite 1400 ID’s: OWDTR-0044-E/3636B-0044 Herndon, VA 20170 Standards: Part 90/RSS-119 http://www.rheintech.com Report #: 2007266 47 of 65 Appendix L: User Manual Please refer to the following pages for the operator’s manual and the product safety manual. Operator’s Manual MM-012099-001 Rev. Bp2, Feb/08 M/A-COM P5400 Series Portable Radio MM-012099-001, Rev. B 2 MANUAL REVISION HISTORY REV DATE REASON FOR REVISION - Sep/07 Initial release. A Oct/07 Added SAR information for UHF-H series P5400 portable radios. B Dec/07 Added SAR information for VHF series P5400 portable radios and updated the product warranty. M/A-COM Technical Publications would particularly appreciate feedback on any errors found in this document and suggestions on how the document could be improved. Submit your comments and suggestions to: Tyco Electronics Wireless Systems Segment M/A-COM, Inc. Fax your comments to: 1-434-455-6851 Technical Publications or 221 Jefferson Ridge Parkway e-mail us at: [email protected] Lynchburg, VA 24501 ACKNOWLEDGEMENTS The software contained in this device is copyrighted by M/A-COM, Inc. Unpublished rights are reserved under the copyright laws of the United States. This device is made under license under one or more of the following U.S. Patents: 4,590,473; 4,636,791; 5,148,482; 5,185,796; 5,271,017; 5,377,229; 4,716,407; 4,972,460; 5,502,767; 5,146,497; 5,164,986; 5,185,795. CREDITS! EDACS are registered trademarks of M/A-COM, Inc. TORX is a registered trademark of CAMCAR division of TEXTRON, Inc. All other product and brand names are trademarks, registered trademarks, or service marks of their respective holders. NOTICE! This manual covers M/A-COM products manufactured and sold by M/A-COM, Inc. This product conforms to the European Union WEEE Directive 2002/96/EC. Do not dispose of this product in a public landfill. Take it to a recycling center at the end of its life. The voice coding technology embodied in this product is protected by intellectual property rights including patent rights, copyrights, and trade secrets of Digital Voice Systems, Inc. The user of this technology is explicitly prohibited from attempting to decompile, reverse engineer, or disassemble the Object Code, or in any other way convert the Object Code into human-readable form. Repairs to this equipment should be made only by an authorized service technician or facility designated by the supplier. Any repairs, alterations, or substitution of recommended parts made by the user to this equipment not approved by the manufacturer could void the user’s authority to operate the equipment in addition to the manufacturer’s warranty. This manual is published by M/A-COM, Inc., without any warranty. Improvements and changes to this manual necessitated by typographical errors, inaccuracies of current information, or improvements to programs and/or equipment, may be made by M/A-COM, Inc., at any time and without notice. Such changes will be incorporated into new editions of this manual. No part of this manual may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, for any purpose, without the express written permission of M/A-COM, Inc. Copyright © 2007 M/A-COM, Inc. All rights reserved. MM-012099-001, Rev. B 3 TABLE OF CONTENTS Page 1 SAFETY CONVENTIONS .............................................................................................................10 2 SAFETY TRAINING INFORMATION.........................................................................................11 2.1 RF EXPOSURE GUIDELINES .............................................................................................11 2.2 ELECTROMAGNETIC INTERFERENCE/COMPATIBILITY.............................................12 3 OPERATING TIPS .........................................................................................................................13 3.1 EFFICIENT RADIO OPERATION .......................................................................................13 3.1.1 Antenna Care and Replacement .................................................................................13 3.1.2 Electronic Devices.....................................................................................................13 3.1.3 Aircraft......................................................................................................................14 3.1.4 Electric Blasting Caps ...............................................................................................14 3.1.5 Potentially Explosive Atmospheres............................................................................14 4 BATTERIES....................................................................................................................................15 4.1 CONDITIONING BATTERY PACKS..................................................................................15 4.1.1 Conditioning NiMH Battery Packs ............................................................................15 4.1.2 Conditioning NiCD Battery Packs .............................................................................15 4.1.3 Additional Information ..............................................................................................16 4.2 CHARGING BATTERY PACKS ..........................................................................................16 4.2.1 Charging Guidelines ..................................................................................................16 4.3 BATTERY PACK USAGE....................................................................................................16 4.3.1 Usage Guidelines.......................................................................................................16 4.4 CHANGING THE BATTERY PACK...........................................................…
Text truncated - open the document above for the full version.
Rhein Tech Laboratories Client: M/A-COM, Inc. 360 Herndon Parkway Model: P5400 VHF Portable Radio Suite 1400 ID’s: OWDTR-0044-E/3636B-0044 Herndon, VA 20170 Standards: Part 90/RSS-119 http://www.rheintech.com Report #: 2007266 38 of 65 Appendix C: FCC Confidentiality Request Letter Please refer to the following page. M/A-COM, Inc. 221 Jefferson Ridge Parkway Lynchburg, VA 24501 Telephone: 434.455.9527 FAX: 434.455.6851 [email protected] www.macom.com February 5, 2008 American TCB, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 Subject: FCC ID: OWDTR-0044-E Original Grant CONFIDENTIALITY M/A-COM, Inc. wishes to submit this confidentiality letter for the record on FCC ID: OWDTR-0044-E, P5400 VHF (150.8 – 173.4 MHz) portable radio. M/A-COM, Inc. is requesting that parts lists, schematics, block diagrams, factory calibration, and operational descriptions for this application not be made routinely available for public inspection. M/A-COM, Inc. considers the information in these exhibits to be classified as trade secrets, pursuant to 47 CFR Section 0.457 and Section 0.459 of the FCC rules. Thank you for your attention to this matter. Daryl Popowitch Regulatory Manager Engineering Project Manager M/A-COM, Inc. – Lynchburg, VA
Rhein Tech Laboratories Client: M/A-COM, Inc. 360 Herndon Parkway Model: P5400 VHF Portable Radio Suite 1400 ID’s: OWDTR-0044-E/3636B-0044 Herndon, VA 20170 Standards: Part 90/RSS-119 http://www.rheintech.com Report #: 2007266 37 of 65 Appendix B: Agency Authorization Please refer to the following page. M/A-COM, Inc. 221 Jefferson Ridge Parkway Lynchburg, VA 24501 Telephone: 434.455.9527 FAX: 434.455.6851 [email protected] www.macom.com February 5, 2008 To Whom It May Concern: The following organization is granted authority to act on M/A-COM’s behalf, to file technical reports, measurements, and forms for M/A-COM equipment with FCC ID: OWDTR-0044-E, P5400 VHF (150.8 – 173.4 MHz) portable radio, as it applies to an original Grant. Ms. Kathy Grzovic Rhein Tech Laboratories, Inc. 360 Herndon Parkway, Suite 1400 Herndon, VA 20170 M/A-COM certifies that M/A-COM is not subject to denial of federal benefits, which includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse ACT of 1988, U.S.C.862. Further, no party, as defined in 47 CFR 1.2002(b), to the application is subject to denial of federal benefits, that includes FCC benefits. Sincerely, Daryl Popowitch Regulatory Manager, Engineering Project Manager M/A-COM, Inc. – Lynchburg, VA
M/A-COM, Inc. 221 Jefferson Ridge Parkway Lynchburg, VA 24501 Telephone: 434.455.9527 FAX: 434.455.6851 [email protected] www.macom.com February 5, 2008 American TCB, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 Subject: FCC ID: OWDTR-0044-E IC: 3636B-0044. M/A-COM seeks application approval for an original Grant on the P5400 VHF (150.8 – 173.4 MHz) portable radio. Application is for Part 90 frequencies only. Exhibits include photographs, schematics, parts list, test reports (EMC and SAR), block diagrams, factory calibration procedure, internal and external photos and an Operator’s manual. Confidentiality letter and Rhein Tech Laboratories, Inc. agent authorization letter to act on M/A-COM’s behalf for this original submittal, have been provide. Thank you for your kind consideration and timely review for this new product entry to the M/A-COM radio product family. Sincerely, Daryl Popowitch Regulatory Manager, Engineering Project Manager M/A-COM, Inc. – Lynchburg, VA
Rhein Tech Laboratories Client: M/A-COM, Inc. 360 Herndon Parkway Model: P5400 VHF Portable Radio Suite 1400 ID’s: OWDTR-0044-E/3636B-0044 Herndon, VA 20170 Standards: Part 90/RSS-119 http://www.rheintech.com Report #: 2007266 52 of 65 Appendix O: External Photographs Photograph 5: Scan and System Versions – Front Rhein Tech Laboratories Client: M/A-COM, Inc. 360 Herndon Parkway Model: P5400 VHF Portable Radio Suite 1400 ID’s: OWDTR-0044-E/3636B-0044 Herndon, VA 20170 Standards: Part 90/RSS-119 http://www.rheintech.com Report #: 2007266 53 of 65 Photograph 6: Top Photograph 7: Bottom Rhein Tech Laboratories Client: M/A-COM, Inc. 360 Herndon Parkway Model: P5400 VHF Portable Radio Suite 1400 ID’s: OWDTR-0044-E/3636B-0044 Herndon, VA 20170 Standards: Part 90/RSS-119 http://www.rheintech.com Report #: 2007266 54 of 65 Photograph 8: PTT Photograph 9: UDC
Rhein Tech Laboratories Client: M/A-COM, Inc. 360 Herndon Parkway Model: P5400 VHF Portable Radio Suite 1400 ID’s: OWDTR-0044-E/3636B-0044 Herndon, VA 20170 Standards: Part 90/RSS-119 http://www.rheintech.com Report #: 2007266 48 of 65 Appendix M: Label & Location RF Label Location ID Label Location Photograph 1: ID Label and RF Label Locations Rhein Tech Laboratories Client: M/A-COM, Inc. 360 Herndon Parkway Model: P5400 VHF Portable Radio Suite 1400 ID’s: OWDTR-0044-E/3636B-0044 Herndon, VA 20170 Standards: Part 90/RSS-119 http://www.rheintech.com Report #: 2007266 49 of 65 Photograph 2: RF Label & ID Label Samples
Rhein Tech Laboratories Client: M/A-COM, Inc. 360 Herndon Parkway Model: P5400 VHF Portable Radio Suite 1400 ID’s: OWDTR-0044-E/3636B-0044 Herndon, VA 20170 Standards: Part 90/RSS-119 http://www.rheintech.com Report #: 2007266 55 of 65 Appendix P: Internal Photographs Photograph 10: Board Placement Layer 1 Rhein Tech Laboratories Client: M/A-COM, Inc. 360 Herndon Parkway Model: P5400 VHF Portable Radio Suite 1400 ID’s: OWDTR-0044-E/3636B-0044 Herndon, VA 20170 Standards: Part 90/RSS-119 http://www.rheintech.com Report #: 2007266 56 of 65 Photograph 11: Board Placement Layer 2 Rhein Tech Laboratories Client: M/A-COM, Inc. 360 Herndon Parkway Model: P5400 VHF Portable Radio Suite 1400 ID’s: OWDTR-0044-E/3636B-0044 Herndon, VA 20170 Standards: Part 90/RSS-119 http://www.rheintech.com Report #: 2007266 57 of 65 Photograph 12: Board Placement Layer 3 Rhein Tech Laboratories Client: M/A-COM, Inc. 360 Herndon Parkway Model: P5400 VHF Portable Radio Suite 1400 ID’s: OWDTR-0044-E/3636B-0044 Herndon, VA 20170 Standards: Part 90/RSS-119 http://www.rheintech.com Report #: 2007266 58 of 65 Photograph 13: Board Placement Layer 4 Rhein Tech Laboratories Client: M/A-COM, Inc. 360 Herndon Parkway Model: P5400 VHF Portable Radio Suite 1400 ID’s: OWDTR-0044-E/3636B-0044 Herndon, VA 20170 Standards: Part 90/RSS-119 http://www.rheintech.com Report #: 2007266 59 of 65 Photograph 14: Main Board Front Rhein Tech Laboratories Client: M/A-COM, Inc. 360 Herndon Parkway Model: P5400 VHF Portable Radio Suite 1400 ID’s: OWDTR-0044-E/3636B-0044 Herndon, VA 20170 Standards: Part 90/RSS-119 http://www.rheintech.com Report #: 2007266 60 of 65 Photograph 15: Main Board Back Rhein Tech Laboratories Client: M/A-COM, Inc. 360 Herndon Parkway Model: P5400 VHF Portable Radio Suite 1400 ID’s: OWDTR-0044-E/3636B-0044 Herndon, VA 20170 Standards: Part 90/RSS-119 http://www.rheintech.com Report #: 2007266 61 of 65 Photograph 16: Rear Casting Front Rhein Tech Laboratories Client: M/A-COM, Inc. 360 Herndon Parkway Model: P5400 VHF Portable Radio Suite 1400 ID’s: OWDTR-0044-E/3636B-0044 Herndon, VA 20170 Standards: Part 90/RSS-119 http://www.rheintech.com Report #: 2007266 62 of 65 Photograph 17: RF Shield Front Rhein Tech Laboratories Client: M/A-COM, Inc. 360 Herndon Parkway Model: P5400 VHF Portable Radio Suite 1400 ID’s: OWDTR-0044-E/3636B-0044 Herndon, VA 20170 Standards: Part 90/RSS-119 http://www.rheintech.com Report #: 2007266 63 of 65 Photograph 18: RF Shield Back Rhein Tech Laboratories Client: M/A-COM, Inc. 360 Herndon Parkway Model: P5400 VHF Portable Radio Suite 1400 ID’s: OWDTR-0044-E/3636B-0044 Herndon, VA 20170 Standards: Part 90/RSS-119 http://www.rheintech.com Report #: 2007266 64 of 65 Photograph 19: Interface Board Front Rhein Tech Laboratories Client: M/A-COM, Inc. 360 Herndon Parkway Model: P5400 VHF Portable Radio Suite 1400 ID’s: OWDTR-0044-E/3636B-0044 Herndon, VA 20170 Standards: Part 90/RSS-119 http://www.rheintech.com Report #: 2007266 65 of 65 Photograph 20: Interface Board Back
Engineering and Testing for EMC and Safety Compliance Accredited under A2LA certificate # 2653.01 360 Herndon Parkway, Suite 1400 Herndon, VA 20170 Tel: 703-689-0368 Fax: 703-689-2056 C C e e r r t t i i f f i i c c a a t t i i o o n n R R e e p p o o r r t t M/A-COM, Inc. 221 Jefferson Ridge Parkway Lynchburg, VA 24501 Phone: (434) 455-9527 Daryl Popowitch E-Mail: [email protected] Model: P5400 VHF-Portable Radio FCC ID: OWDTR-0044-E IC: 3636B-0044 November 29, 2007 Standards Referenced for this Report Part 2: 2006 Frequency Allocations and Radio Treaty Matters; General Rules and Regulations Part 90: 2006 Private Land Portable Radio Services ANSI TIA-603-C-2004 Land Portable FM or PM Communications Equipment - Measurement and Performance Standards ANSI/TIA/EIA–102.CAAA; 2002 Digital C4FM/CQPSK Transceiver Measurement Methods RSS-119 Issue 9 2007 Land Portable and Fixed Radio Transmitters and Receivers 27.41 to 960.0 MHz Report Prepared by Test Engineer: Dan Baltzell Document Number: 2007266/QRTL07-311 This report may not be reproduced, except in full, without the full written approval of Rhein Tech Laboratories, Inc. and M/A-COM, Inc. The test results relate only to the item tested . Engineering and Testing for EMC and Safety Compliance Accredited under A2LA certificate # 2653.01 360 Herndon Parkway, Suite 1400 Herndon, VA 20170 Tel: 703-689-0368 Fax: 703-689-2056 Frequency Range (MHz) Rated Transmit Power (W) (Conducted) Frequency Tolerance (ppm) Emission Designator 150.8 – 173.4 5.0/0.5 0.55 16K0F3E (Analog Voice; WB) 150.8 – 173.4 5.0/0.5 0.55 11K0F3E (Analog Voice; NB) 150.8 – 173.4 5.0/0.5 0.55 15K6F1D (Digital 2-FSK (9600 Data) WB) 150.8 – 173.4 5.0/0.5 0.55 15K6F1E (Digital Voice 2-FSK (9600 Data) WB) 150.8 – 173.4 5.0/0.5 0.55 10K8F1D (Digital 2-FSK (9600 Data) NB) 150.8 – 173.4 5.0/0.5 0.55 10K8F1E (Digital 2-FSK (9600 Data Voice) NB) 150.8 – 173.4 5.0/0.5 0.55 7K8F1D (Digital 2-FSK (4800 Data) NB) 150.8 – 173.4 5.0/0.5 0.55 7K8F1E (Digital 2-FSK (4800 Data Voice) NB) 150.8 – 173.4 5.0/0.5 0.55 8K4F1D (Digital C4FM (9600 Data) NB) 150.8 – 173.4 5.0/0.5 0.55 8K4F1E (Digital C4FM (9600 Data Voice) NB) Rhein Tech Laboratories Client: M/A-COM, Inc. 360 Herndon Parkway Model: P5400 VHF Portable Radio Suite 1400 ID’s: OWDTR-0044-E/3636B-0044 Herndon, VA 20170 Standards: Part 90/RSS-119 http://www.rheintech.com Report #: 2007266 3 of 35 Table of Contents 1 General Information........................................................................................................................................... 6 1.1 Test Facility.........................................................................................................................................................................................6 1.2 Related Submittal(s)/Grant(s) .............................................................................................................................................................6 1.3 Product Description.............................................................................................................................................................................6 2 Tested System Details...................................................................................................................................... 7 3 FCC Rules and Regulations Part 2 §2.1033(c)(8) Voltages and Currents Through The Final Amplifying Stage................................................................................................................................................................. 8 4 FCC Rules and Regulations Part 2 §2.1046(a): RF Power Output RSS-119 §4.1: Output Power Test......... 9 4.1 Test Procedure....................................................................................................................................................................................9 4.2 Test Data.............................................................................................................................................................................................9 5 FCC Rules and Regulations Part 2 §2.1051: Spurious Emissions at Antenna Terminals; Part 90 §90.210: Emissions Masks; RSS-119 §4.2: Transmitter Unwanted Emissions............................................................ 10 5.1 Test Procedure..................................................................................................................................................................................10 5.2 Test Data...........................................................................................................................................................................................10 6 FCC Rules and Regulations Part 2 §2.1053(a): Field Strength of Spurious Radiation; RSS-119 §4.2: Unwanted Emissions....................................................................................................................................... 12 6.1 Test Procedure..................................................................................................................................................................................12 6.2 Test Data...........................................................................................................................................................................................12 6.2.1 CFR 47 Part 90.210 Requirements..............................................................................................................................................12 7 FCC Rules and Regulations Part 2 §2.1049: Occupied Bandwidth; Part 90 §90.210(i) & (j): Emissions Masks; RSS-119 §4.2: Transmitter Unwanted Emissions............................................................................. 14 7.1 Test Procedure............................................................................................................................................................................…
Text truncated - open the document above for the full version.
Rhein Tech Laboratories Client: M/A-COM, Inc. 360 Herndon Parkway Model: P5400 VHF Portable Radio Suite 1400 ID’s: OWDTR-0044-E/3636B-0044 Herndon, VA 20170 Standards: Part 90/RSS-119 http://www.rheintech.com Report #: 2007266 50 of 65 Appendix N: Test Configuration Photographs Photograph 3: Radiated TX Spurious Emissions – Front View Rhein Tech Laboratories Client: M/A-COM, Inc. 360 Herndon Parkway Model: P5400 VHF Portable Radio Suite 1400 ID’s: OWDTR-0044-E/3636B-0044 Herndon, VA 20170 Standards: Part 90/RSS-119 http://www.rheintech.com Report #: 2007266 51 of 65 Photograph 4: Radiated TX Spurious Emissions – Rear View
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 2 | 9 | 150.8 MHz - 173.4 MHz | 500.00 mW | 8K40F1E | 0.55 ppm |
XL-85M, 700/800MHZ Land Mobile Radio
Equipment Class
DTS - Digital Transmission System
Two47, Base Station Transceiver (700 MHz Band)
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
XL-90D 7/8/900 MHz Mobile Based Terminal Device
Equipment Class
PCB - PCS Licensed Transmitter
XL-400P, Multi-Band Portable Land Mobile Radio
Equipment Class
TNF - Licensed Non-Broadcast Transmitter Held to Face
XL-95P, 7/800MHz Portable Land Mobile Radio
Equipment Class
NII - Unlicensed National Information Infrastructure TX