FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Wireless Matrix Corporation/
  3. P5I-907-FNN-A

P5I-907-FNN-AWireless Telemetry Unit with RIM 802 DataTAC Radio

Wireless Matrix Corporation
Wireless Telemetry Unit with RIM 802 DataTAC Radio - FCC ID P5I-907-FNN-A - Wireless Matrix Corporation
Click to zoom

Application Details

Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Date of Grant
Apr 07, 2002
Application Purpose
Original Equipment
Date of Application
Feb 18, 2002
Equipment Note
Wireless Telemetry Unit with RIM 802 DataTAC Radio
Frequency Range
806.00000000 - 821.00000000
Company
Wireless Matrix Corporation
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗
↗

ID Label/Location Info

↗
↗

Internal Photos

↗
↗

RF Exposure Info

↗
↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

W ireless Matrix Corporation#102, 1530 - 27 Avenue NEPage 1 of 62 Document # xxx-xxx-xxxCalgary, AB, Canada T2E 7S6 2002.02.01Ph. 403.250.3949 Fax 403.250.8163www.wrx-ca.com Terrestrial Processor Assisted Connector Installation and Configuration Manual Version 2.2X TPAC Configuration Manual W ireless Matrix Corporation#102, 1530 - 27 Avenue NEPage 2 of 62 Document # xxx-xxx-xxxCalgary, AB, Canada T2E 7S6 2002.02.01Ph. 403.250.3949 Fax 403.250.8163www.wrx-ca.com IP Anywhere TPAC Configuration Manual Copyright © 2002 Wireless Matrix. All rights reserved. Printed in Canada This document is proprietary to Wireless Matrix Corporation. Do not reproduce, use or disclose without permission. We have made every effort to ensure the accuracy of all information contained in this document. However, Wireless Matrix Corporation makes no expressed or implied warranty or representation based upon the enclosed information FCC RF EXPOSURE INFORMATION In August 1996 the Federal Communications Commission (FCC) of the United States with its action in Report and Order FCC 96 -326 adopted an updated safety standard for human exposure to radio frequency (RF) electromagnet ic energy emitted by FCC regulated transmitters. Those guidelines are consistent with the safety standard previously set by both U.S. and international standards bodies. The design of this device complies with the FCC guidelines and these international s tandards. Use only the supplied or an approved antenna. Unauthorized antennas, modifications, or attachments could impair call quality, damage the phone, or result in violation of FCC regulations. All persons must be at least 20 cm from the antenna w hen the transmitter is operating and must not be co -located or operating in conju nction with any other antenna or transmitter in order to comply with FCC RF exposure requirements. For more information about RF exposure, please visit the FCC website at www.fcc.gov Please read this information before use TPAC Configuration Manual W ireless Matrix Corporation#102, 1530 - 27 Avenue NEPage 3 of 62 Document # xxx-xxx-xxxCalgary, AB, Canada T2E 7S6 2002.02.01Ph. 403.250.3949 Fax 403.250.8163www.wrx-ca.com Table of Contents ABOUT THIS MANUAL ...................................................................................................6 CONVENTIONS .................................................................................................................7 1INTRODUCTION........................................................................................................8 1.1TPAC F EATURES......................................................................................................8 2TPAC SPECIFICATIONS ...........................................................................................9 2.1I NSTALLATIONCONSIDERATIONS............................................................................ 11 3TPAC CONFIGURATION........................................................................................ 12 3.1I NTERFACING TO A TPAC........................................................................................ 12 3.2TPAC U SERINTERFACE.......................................................................................... 16 3.2.1General PAC Commands ................................................................................. 16 3.2.2Setting PAC Values ......................................................................................... 17 3.2.3Loading Drivers ............................................................................................... 17 3.2.4Displaying and Setting the System Time .......................................................... 19 3.2.5PAC Application Commands ........................................................................... 20 3.3I/O P OINTDATABASE.............................................................................................. 21 3.4A LARMS................................................................................................................. 22 3.4.1Deadband Alarms ............................................................................................ 23 3.5S CHEDULING........................................................................................................... 24 4TPAC NETWORK DRIVERS AND SETTINGS..................................................... 26 5TPAC RTU DRIVERS AND SETTINGS.................................................................. 28 5.1MODBUS D RIVER................................................................................................. 29 5.2ROC P ROTOCOLDRIVER........................................................................................ 32 5.3A LLENBRADLEYDF1 DRIVER................................................................................ 35 5.4DATATAKERDRIVER.............................................................................................. 38 5.5T OSHIBATOSVERT-130 DRIVER.............................................................................. 41 5.6SPARTEKSS6010 DRIVER....................................................................................... 43 5.7GARMINGPS DRIVER............................................................................................. 45 5.8DELIMITEDASCII DRIVER...................................................................................... 47 5.9AFI MVS DRIVER.................................................................................................. 48 5.10 PRESSURETRAXILI TECHNOLOGIESDRIVER........................................................... 49 5.11 ABB P OWERPLUSALPHADRIVER........................................................................... 50 5.12 E NVIRONMENTALSYSTEMSCORPORATION(ESC) DATALOGGERDRIVER............... 51 5.13 G RANTDATALOGGER1000SERIESSQUIRRELMETERDRIVER................................. 54 5.14 B RISTOLBABCOCKBSA DRIVER......................................................................…

Text truncated - open the document above for the full version.

Cover Letter(s)

Celltech Research Inc. 1955 Moss Court, Kelowna, B.C. Canada V1Y 9L3 Tel. 250-860-3130 • Fax. 250-860-3110 • e-mail: [email protected] www.celltechlabs.com February 19, 2002 Federal Communications Commission Equipment Approval Services 7435 Oakland Mills Road Columbia, MD 21046 SUBJECT: WIRELESS MATRIX CORPORATION FCC ID: P5I-907-FNN-A Part 90 Certification Gentlemen: On behalf of Wireless Matrix Corporation we hereby submit an application for Part 90 Certification of a Wireless Telemetry Unit with RIM 802 DataTAC Radio Modem as follows: FCC ID: P5I-907-FNN-A Model(s): 907-FNN-A Equipment Class: Licensed Non-Broadcast Station Transmitter (TNB) Equipment Type: Wireless Telemetry Unit with RIM 802 DataTAC Radio Modem (Terrestrial Processor Assisted Connector) Tx Freq. Range: 806 - 821 MHz Rx Freq. Range: 851 - 870 MHz Max. RF Output Power: 2.65 Watts (ERP) Emission Designator: 20K0F1D Antenna Type(s): Permanent Stud-Mount ¼-Wave Whip (Antenna Factor) Enclosure Type(s): Aluminum & Plastic Attached is the authorization letter, confidentiality request, Part 90 measurement report data and test plots, MPE measurement report data & photographs, test setup photographs, internal and external EUT photographs, FCC ID label & location, block diagrams (confidential), circuit diagrams (confidential), parts list (confidential), tune-up procedure (confidential), operational description (confidential), and the user's manual. If you have any questions or comments concerning the above, please contact the undersigned. Sincerely, Shawn McMillen General Manager Celltech Research Inc. Testing & Engineering Lab cc: Wireless Matrix Corporation

Cover Letter(s)

RESEARCH IN MOTION Research In Motion Limited 295 Phillip Street Waterloo, Ontario Canada N2L 3W8 +1 519 888 7465, fax +1 519 888 6906 E-mail: [email protected] Our Ref: 02400-CERT-FCC-COVER-021_modFebruary 20, 2002 Federal Communication Commission Equipment Authorization Division Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21045 Reference :FCC ID : L6AR802D-2-O Subject :Letter requesting confidentiality of R802D-2-O radio modem device FCC Certification application . Pursuant to CFR 47 Chapter 1 Section 0.459, Research In Motion Limited (RIM) requests that the following identified detailed technical information regarding the R802D-2-O device be held confidential by the Federal Communication Commission (FCC) and as such be withheld from public inspection. RIM does not disclose proprietary confidential information about our products to any third parties and as such we request that the FCC does the same and forward the confidentiality acceptance letter to RIM. Our FCC submissions are considered proprietary confidential information. Pursuant to CFR 47 Chapter 1 Sections 0.457(d) and 0.457(d)(2)(i) the exhibits contain details of trade secrets and technical data that is customarily guarded from competitors and not released to the public by Research In Motion Limited. The specific parts of the Exhibits indicated in this letter are considered confidential by RIM and as such should be prevented from disclosure to public and competitors. RIM has taken necessary measures to have limited access to confidential documents only to RIM internal employees on a need-to-know basis, and have signed confidentiality agreements with employees. If the disclosure of such information is made public, it will cause serious competitive harm to RIM. Previously, none of the requested confidential Exhibits have been disclosed to third parties by RIM. The following Exhibits with specific sections described, submitted with the Form 731 Attachments should be held confidential: Exhibit Parts List/Tune Up InfoProcedur.doc “DOC-01606-007”, Users.doc “DOC-1606-006” CFR 47 Section 2.1033(c)(9) - Description of operational, test, and device tune-up technical procedure and operators’ manual. Section 010-10, CFR 47 Section 2.1033 (c) (10) - Description of Circuitry and Devices provided for: frequency stabilizing circuitry, suppression of spurious radiation, circuits for modulation limiting, and circuits for power limiting Exhibit Operational DescriptionSection 010-13 and 010-13-1, CFR 47 Section 2.1033 (c) (13) - Description of digital modulation format and necessary bandwidth Exhibit Parts List/Tune Up InfoSection 010-13-2 and 010-13-3, CFR 47 Section 2.1033 (c) (13) – Modulation generation methods and circuits. Detailed diagrams of modulation format and generation methods and circuits Exhibit Operational DescriptionSection 011-1 and 011-2, CFR 47 Section 2.1033 - Detailed system and functional description Exhibit Parts List/Tune Up InfoSection 011-3, CFR 47 Section 2.1033 - Detailed technical RF and power circuit description Exhibit Block Diagram02400-CERT-FCC-BLOCK-“R802D-2-O RADIO BLOCK”, CFR 47 Section 2.1033 – Detailed technical radio modem block diagram Exhibit Schematics“RIM 802D OEM DataTAC - AMSC” SCH-02400-001 Rev B, CFR 47 Section 2.1033 (c) (10) - Complete technical schematic circuit diagrams Yours truly, Daoud S. Attayi, B.Eng. Compliance Specialist Research In Motion Limited ( 519 ) 888 – 7465 x2941 [email protected] RESEARCH IN MOTION Research In Motion Limited 295 Phillip Street Waterloo, Ontario Canada N2L 3W8 +1 519 888 7465, fax +1 519 888 6906 E-mail: [email protected] Our Ref: 02400-CERT-FCC-Cover-022_modFebruary 20, 2002 Federal Communications Commission Equipment Authorization Division Application Processing Branch 7435 Oakland Mills Rd. Columbia, Md. 21046 FCC ID:L6AR802D-2-O Subject:FCC Part 90 Certification Application for Research In Motion Limited, Model R802D-2-O This is to inform that Research In Motion is submitting the technical documentation of our radio modem Model R802D-2-O (existing FCC ID: L6AR802D-2-O ) in support of the application for Certification of our integrator, Wireless Matrix Corporation, with FCC IDP5I-907-FNN-A The Model R802D-2-O is a radio modem intended for integration into other equipment to allow wireless data communication. All required documents in compliance with Parts 2 and 90 of the FCC Rules have been provided in the attached Exhibits. Research In Motion would like to request confidentiality as indicated in the Form 731, Item 8 and as requested in the letter Ref: CERT-01677-021_mod, under Exhibit “Covering Letters”. Please do not hesitate to call at (519) 888-7465 x 2941 or email at [email protected] should you require additional information or have any questions. Yours truly, Daoud S. Attayi, B.Eng. Compliance Specialist Research In Motion Limited ( 519 ) 888 – 7465 x2941 [email protected]

Cover Letter(s)

Celltech Research Inc. 1955 Moss Court, Kelowna, B.C. Canada V1Y 9L3 Tel. 250-860-3130 • Fax. 250-860-3110 • e-mail: [email protected] www.celltechlabs.com April 5, 2002 Federal Communications Commission Equipment Approval Services 7435 Oakland Mills Road Columbia, MD 21046 Attn: Stan Lyles SUBJECT: WIRELESS MATRIX CORPORATION FCC ID: P5I-907-FNN-A 731 Confirmation No.: EA844974 Correspondence Reference No.: 22533 Dear Stan: On behalf of Wireless Matrix Corporation is our response to your e-mail dated April 5, 2002 requesting additional information for the subject application. 1. The equipment specification inadvertently stated that the device is a Software Defined Radio, however this device is not considered to be a Software Defined Radio. Please disregard any reference to such. If you have any further questions or comments concerning the above, please contact the undersigned. Sincerely, Shawn McMillen General Manager Celltech Research Inc. Testing & Engineering Lab cc: Wireless Matrix Corporation

External Photos

CELLTECH RESEARCH INC. Test Report S/N: 011402-197P5I 1955 Moss Court, Kelowna Test Dates: January 22-24, 2002 B.C. Canada V1Y 9L3 FCC Part 90 Measurements © 2002 Celltech Research Inc. Wireless Matrix Corporation FCC ID: P5I-907-FNN-A Wireless Telemetry Unit with RIM 802 DataTAC Radio Modem EXTERNAL EUT PHOTOGRAPHS Aluminum Enclosure CELLTECH RESEARCH INC. Test Report S/N: 011402-197P5I 1955 Moss Court, Kelowna Test Dates: January 22-24, 2002 B.C. Canada V1Y 9L3 FCC Part 90 Measurements © 2002 Celltech Research Inc. Wireless Matrix Corporation FCC ID: P5I-907-FNN-A Wireless Telemetry Unit with RIM 802 DataTAC Radio Modem EXTERNAL EUT PHOTOGRAPHS Aluminum Enclosure CELLTECH RESEARCH INC. Test Report S/N: 011402-197P5I 1955 Moss Court, Kelowna Test Dates: January 22-24, 2002 B.C. Canada V1Y 9L3 FCC Part 90 Measurements © 2002 Celltech Research Inc. Wireless Matrix Corporation FCC ID: P5I-907-FNN-A Wireless Telemetry Unit with RIM 802 DataTAC Radio Modem EXTERNAL EUT PHOTOGRAPHS Aluminum Enclosure CELLTECH RESEARCH INC. Test Report S/N: 011402-197P5I 1955 Moss Court, Kelowna Test Dates: January 22-24, 2002 B.C. Canada V1Y 9L3 FCC Part 90 Measurements © 2002 Celltech Research Inc. Wireless Matrix Corporation FCC ID: P5I-907-FNN-A Wireless Telemetry Unit with RIM 802 DataTAC Radio Modem EXTERNAL EUT PHOTOGRAPHS Plastic Enclosure CELLTECH RESEARCH INC. Test Report S/N: 011402-197P5I 1955 Moss Court, Kelowna Test Dates: January 22-24, 2002 B.C. Canada V1Y 9L3 FCC Part 90 Measurements © 2002 Celltech Research Inc. Wireless Matrix Corporation FCC ID: P5I-907-FNN-A Wireless Telemetry Unit with RIM 802 DataTAC Radio Modem EXTERNAL EUT PHOTOGRAPHS Plastic Enclosure CELLTECH RESEARCH INC. Test Report S/N: 011402-197P5I 1955 Moss Court, Kelowna Test Dates: January 22-24, 2002 B.C. Canada V1Y 9L3 FCC Part 90 Measurements © 2002 Celltech Research Inc. Wireless Matrix Corporation FCC ID: P5I-907-FNN-A Wireless Telemetry Unit with RIM 802 DataTAC Radio Modem EXTERNAL EUT PHOTOGRAPHS Plastic Enclosure

ID Label/Location Info

CELLTECH RESEARCH INC. Test Report S/N: 011402-197P5I 1955 Moss Court, Kelowna Test Dates: January 22-24, 2002 B.C. Canada V1Y 9L3 FCC Part 90 Certification © 2002 Celltech Research Inc. Wireless Matrix Corporation FCC ID: P5I-907-FNN-A Wireless Telemetry Unit with RIM 802 DataTAC Radio Modem FCC ID LABEL & LOCATION LABELLING REQUIREMENTS PER §§ 2.925 The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time of purchase. SEE NEXT PAGE FOR FCC ID LABEL DATEDESCRIPTION OF CHANGEREVECNDRNAPP 2 PROJECTION 3RD ANGLE SCALE:PLOTTED: APP CHK DRN DWG TITLE SIZEDWG No SHTOF REV A DIMENSIONS IN INCHES DO NOT SCALE DRAWING 1345678 87645312 B C D A B C D M. LOBEL 01/17/02 01/17/02D. MacNEIL 01/17/02 T. CAREY 01 LABEL, TPAC1000 907-FNN-ANRX WRX P/N 600-020-0027R01 B050-500-007601 1:1 - 11 TPAC1000 907-FNN-ANRX MIN 4070030000 RIM OEM MODULE: LLI: ESN: FCC ID: CANADA:2503 195 603A L6AR802D-2-0 XXXXXXXXXXXX XXXXXXXXX FCC ID: P5I-907-FNN-A MADE IN CANADA 0.813 .125 RAD (4) NOTES: 1. MATERIAL: BRADY B-483 STOCK WITH R6000 OR R4900 SERIES RIBBON. 2. FONT: ARIAL. 3. USE 300 DPI MINIMUM PRINTER. 4. USE CODE 128 BARCODE TO FIT.INCH.WIDTH. 5. BARCODE CONTAINS CONFIGURATION NUMBER AND MIN NUMBER. 6. BARCODE FORMAT "907-FNN-ANRX407001XXXX". 7. ALL DIMENSIONS ±1/16. CONFIGURATION NUMBER LLI NUMBER FROM 802D MODULE ESN NUMBER FROM 802D MODULE 4.000 CANADA: XXXX XXX XXXX TC 01/17/02MLRELEASE TO PRODUCTION218

ID Label/Location Info

CELLTECH RESEARCH INC. Test Report S/N: 011402-197P5I 1955 Moss Court, Kelowna Test Dates: January 22-24, 2002 B.C. Canada V1Y 9L3 FCC Part 90 Certification © 2002 Celltech Research Inc. Wireless Matrix Corporation FCC ID: P5I-907-FNN-A Wireless Telemetry Unit with RIM 802 DataTAC Radio Modem FCC ID LABEL & LOCATION LABELLING REQUIREMENTS PER §§ 2.925 The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time of purchase. SEE NEXT PAGE FOR FCC ID LABEL DATE DESCRIPTION OF CHANGE REV ECN DRNAPP 2 PROJECTION 3RD ANGLE SCALE:PLOTTED: APP CHK DRN DWG TITLE SIZEDWG No SHTOF REV A DIMENSIONS IN INCHES DO NOT SCALE DRAWING 1345678 87645312 B C D A B C D M. LOBEL01/17/02 01/17/02D. MacNEIL 01/17/02 T. CAREY 01 218 LABEL, TPAC1000 907-FNN-ANTX WRX P/N 600-020-0033R01 B050-500-008201 1:1 - 11 .062 RAD (4) NOTES: 1. MATERIAL: BRADY B-483 STOCK WITH R6000 OR R4900 SERIES RIBBON. 2. FONT: ARIAL. 3. USE 300 DPI MINIMUM PRINTER. 4. USE CODE 128 BARCODE TO FIT. 5. BARCODE CONTAINS CONFIGURATION NUMBER AND MIN NUMBER. 6. BARCODE FORMAT "907-FNN-ANTX407001XXXX". 7. ALL DIMENSIONS ±1/16. CONFIGURATION NUMBER LLI NUMBER FROM 802D MODULE ESN NUMBER FROM 802D MODULE MIN 4070030000 1.500 0.500 RELEASE TO PRODUCTIONML01/17/02 TC

Internal Photos

CELLTECH RESEARCH INC. Test Report S/N: 011402-197P5I 1955 Moss Court, KelownaTest Dates: January 22-24, 2002 B.C. Canada V1Y 9L3 FCC Part 90 Measurements © 2002 Celltech Research Inc.Wireless Matrix Corporation FCC ID: P5I-907-FNN-A Wireless Telemetry Unit with RIM 802 DataTAC Radio Modem INTERNAL EUT PHOTOGRAPHS AluminumEnclosure CELLTECH RESEARCH INC. Test Report S/N: 011402-197P5I 1955 Moss Court, KelownaTest Dates: January 22-24, 2002 B.C. Canada V1Y 9L3 FCC Part 90 Measurements © 2002 Celltech Research Inc.Wireless Matrix Corporation FCC ID: P5I-907-FNN-A Wireless Telemetry Unit with RIM 802 DataTAC Radio Modem INTERNAL EUT PHOTOGRAPHS AluminumEnclosure CELLTECH RESEARCH INC. Test Report S/N: 011402-197P5I 1955 Moss Court, KelownaTest Dates: January 22-24, 2002 B.C. Canada V1Y 9L3 FCC Part 90 Measurements © 2002 Celltech Research Inc.Wireless Matrix Corporation FCC ID: P5I-907-FNN-A Wireless Telemetry Unit with RIM 802 DataTAC Radio Modem INTERNAL EUT PHOTOGRAPHS AluminumEnclosure CELLTECH RESEARCH INC. Test Report S/N: 011402-197P5I 1955 Moss Court, KelownaTest Dates: January 22-24, 2002 B.C. Canada V1Y 9L3 FCC Part 90 Measurements © 2002 Celltech Research Inc.Wireless Matrix Corporation FCC ID: P5I-907-FNN-A Wireless Telemetry Unit with RIM 802 DataTAC Radio Modem INTERNAL EUT PHOTOGRAPHS AluminumEnclosure CELLTECH RESEARCH INC. Test Report S/N: 011402-197P5I 1955 Moss Court, KelownaTest Dates: January 22-24, 2002 B.C. Canada V1Y 9L3 FCC Part 90 Measurements © 2002 Celltech Research Inc.Wireless Matrix Corporation FCC ID: P5I-907-FNN-A Wireless Telemetry Unit with RIM 802 DataTAC Radio Modem INTERNAL EUT PHOTOGRAPHS Plastic Enclosure CELLTECH RESEARCH INC. Test Report S/N: 011402-197P5I 1955 Moss Court, KelownaTest Dates: January 22-24, 2002 B.C. Canada V1Y 9L3 FCC Part 90 Measurements © 2002 Celltech Research Inc.Wireless Matrix Corporation FCC ID: P5I-907-FNN-A Wireless Telemetry Unit with RIM 802 DataTAC Radio Modem INTERNAL EUT PHOTOGRAPHS Plastic Enclosure CELLTECH RESEARCH INC. Test Report S/N: 011402-197P5I 1955 Moss Court, KelownaTest Dates: January 22-24, 2002 B.C. Canada V1Y 9L3 FCC Part 90 Measurements © 2002 Celltech Research Inc.Wireless Matrix Corporation FCC ID: P5I-907-FNN-A Wireless Telemetry Unit with RIM 802 DataTAC Radio Modem INTERNAL EUT PHOTOGRAPHS Plastic Enclosure

RF Exposure Info

CELLTECH RESEARCH INC. Test Report S/N: 011402-198P5I 1955 Moss Court, Kelowna Test Date(s): January 23, 2002 B.C. Canada V1Y 9L3 MPE Measurements _____________________________________________________________________________________________________________ © 2002 Celltech Research Inc. CERTIFICATE OF COMPLIANCE MPE EVALUATION This wireless mobile device has been shown to be compliant for localized Maximum Permissible Exposure (MPE) for uncontrolled environment/general population exposure limits specified in ANSI/IEEE Std. C95.1-1992 and has been tested in accordance with the measurement procedures specified in ANSI/IEEE Std. C95.3-1999. I attest to the accuracy of data. All measurements were performed by me or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. This test report shall not be reproduced partially, or in full, without the prior written approval of Celltech Research Inc. The results and statements contained in this report pertain only to the device(s) evaluated. Shawn McMillen General Manager Celltech Research Inc. Test Lab: CELLTECH RESEARCH INC. Testing and Engineering Lab 1955 Moss Court Kelowna, B.C. Canada V1Y 9L3 Phone: 250 - 860-3130 Fax: 250 - 860-3110 Toll Free: 1-877-545-6287 e-mail: [email protected] web site: www.celltechlabs.com Applicant Information: WIRELESS MATRIX CORPORATION Suite 102, 1530-27 Avenue NE Calgary, Alberta Canada T2E 7S6 FCC Rule Part(s): 90, 2.1091; 1.1310; ET Docket 93-62 IC Rule Part(s): RSS-119 Issue 6, RSS-102 Issue 1 FCC Classification: Licensed Non-Broadcast Station Transmitter (TNB) IC Classification: Land Mobile Radio Transmitter FCC ID: P5I-907-FNN-A Model: 907-FNN-A Equipment Type: Wireless Telemetry Unit with RIM 802 DataTAC Radio Modem Terrestrial Processor Assisted Connector (TPAC) with Aluminum & Plastic Enclosures Tx Frequency Range: 806 - 821 MHz Rx Frequency Range: 851 - 870 MHz Max. RF Output Power: 2.65 Watts (ERP) Antenna Type: Permanent Stud-Mount ¼-Wave Whip (Antenna Factor P/N: ANT-868-PW-QW) CELLTECH RESEARCH INC. Test Report S/N: 011402-198P5I 1955 Moss Court, Kelowna Test Date(s): January 23, 2002 B.C. Canada V1Y 9L3 MPE Measurements _____________________________________________________________________________________________________________ © 2002 Celltech Research Inc. TABLE OF CONTENTS 1.0 INTRODUCTION................................................................... 1 2.0 DESCRIPTION OF EUT.......................................................... 1 3.0 MPE MEASUREMENT GUIDELINES........................................ 2 4.0 DEFINITION......................................................................... 2 5.0 MPE LIMITS........................................................................ 3-4 6.0 DETAILS OF MPE EVALUATION........................................... 5 7.0 MPE EVALUATION SUMMARY.............................................. 6-11 8.0 SYSTEM CALIBRATION........................................................ 12 9.0 SYSTEM SPECIFICATIONS.................................................... 12 10.0 REFERENCES...................................................................... 12 APPENDIX A - MPE TEST SETUP PHOTOGRAPHS............................... 13 APPENDIX B - ANTENNA SPECIFICATIONS........................................ 14 CELLTECH RESEARCH INC. Test Report S/N: 011402-198P5I 1955 Moss Court, Kelowna Test Date(s): January 23, 2002 B.C. Canada V1Y 9L3 MPE Measurements _____________________________________________________________________________________________________________ © 2002 Celltech Research Inc. WIRELESS MATRIX CORP. FCC ID: P5I-907-FNN-A 1 Wireless Telemetry Unit with RIM 802 DataTAC Radio Modem 1.0 SCOPE Environmental evaluation measurements of Maximum Permissible Exposure (MPE) to radio frequency (RF) radiation from transmitting devices for compliance with the technical rules and regulations of the U.S. Federal Communications Commission (1)* and Industry Canada (5). 1.1 INTRODUCTION This measurement report describes the Maximum Permissible Exposure (MPE) tests of the Wireless Matrix Corporation Model: 907-FNN-A Wireless Telemetry Unit FCC ID: P5I-907-FNN-A with RIM 802D-2-O DataTAC Radio Modem. The test procedures described in FCC CFR47 2.1091, 1.1310, American National Standards Institute C95.1-1992 (2), C95.3-1992 (3), and OET Bulletin 65, Supplement C (4) were employed. A description of the product and operating configuration, detailed summary of the test results, methodology and procedures used in the evaluation, equipment used, and the various provisions of the rules are included within this test report. 2.0 DESCRIPTION of Equipment Under Test (EUT) * Note: See page 12 for list of References. EUT Type Wireless Telemetry Unit with RIM 802 DataTAC Radio Modem Radio Type RIM 802D-2-O (DataTAC Network) FCC Equipment Class Licensed Non-Broadcast Station Transmitter (TNB) FCC Rule Part(s) 90, 2.1091; 1.1310 ET Docket 93-62 IC Equipment Class Land Mobile Radio Transmitter IC Rule Part(s) RSS-119 Issue 6 RSS-102 Issue 1 Max. RF Output Power 2.65 Watts (ERP) FCC ID P5I-907-FNN-A Tx Frequency Range (MHz) 806 - 821 Model(s) 907-FNN-A Rx Frequency Range (MHz) 851 - 870 Antenna Type Permanent Stud-Mount ¼ Wave Whip Signal Modulation(s) FSK Antenna P/N Antenna Factor ANT-868-PW-QW CELLTECH RESEARCH INC. Test Report S/N: 011402-198P5I 1955 Moss Court, Kelowna Test Date(s): January 23, 2002 B.C. Canada V1Y 9L3 MPE Measurements _____________________________________________________________________________________________________________ © 2002 Celltech Research Inc. WIRELESS MATRIX CORP. FCC ID: P5I-907-FNN-A 2 Wireless Telemetry Unit with RIM 802 DataTAC Radio Modem 3.0 MPE MEASUREMENT GUIDELINES The safety limits used for the RF exposure environmental evaluation measurements are based on the criteria published by the Ame…

Text truncated - open the document above for the full version.

RF Exposure Info

FCC RF EXPOSURE INFORMATION In August 1996 the Federal Communications Commission (FCC) of the United States with its action in Report and Order FCC 96-326 adopted an updated safety standard for human exposure to radio frequency (RF) electromagnetic energy emitted by FCC regulated transmitters. Those guidelines are consistent with the safety standard previously set by both U.S. and international standards bodies. The design of this device complies with the FCC guidelines and these international standards. Use only the supplied or an approved antenna. Unauthorized antennas, modifications, or attachments could impair call quality, damage the phone, or result in violation of FCC regulations. All persons must be at least 20 cm from the antenna when the transmitter is operating and must not be co-located or operating in conjunction with any other antenna or transmitter in order to comply with FCC RF exposure requirements. For more information about RF exposure, please visit the FCC website at www.fcc.gov Please read this information before use

Test Report

CELLTECH RESEARCH INC. Test Report S/N: 011402-197P5l 1955 Moss Court, Kelowna Test Dates: January 22-24, 2002 B.C. Canada V1Y 9L3 FCC Part 90 Certification _________________________________________________________________________________________________________________ © 2002 Celltech Research Inc. CERTIFICATE OF COMPLIANCE FCC PART 90 CERTIFICATION This equipment has been shown to be capable of compliance with the applicable technical standards as indicated in the measurement report and was tested in accordance with the measurement procedures specified in §2.947. I attest to the accuracy of data. All measurements reported herein were performed by me or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. This test report shall not be reproduced partially, or in full, without the prior written approval of Celltech Research Inc. The results and statements contained in this report pertain only to the device(s) evaluated Shawn McMillen General Manager Celltech Research Inc. Test Lab: CELLTECH RESEARCH INC. Testing and Engineering Services 1955 Moss Court Kelowna, B.C. Canada V1Y 9L3 Phone: 250 - 860-3130 Fax: 250 - 860-3110 Toll Free: 1-877-545-6287 e-mail: [email protected] web site: www.celltechlabs.com Applicant Information: WIRELESS MATRIX CORPORATION Suite 102, 1530-27 Avenue NE Calgary, Alberta Canada T2E 7S6 FCC Classification: Licensed Non-Broadcast Station Transmitter (TNB) FCC Rule Part(s): §90, §2 FCC ID: P5I-907-FNN-A Model: 907-FNN-A Equipment Type: Wireless Telemetry Unit with RIM 802 DataTAC Radio Modem Terrestrial Processor Assisted Connector (TPAC) with Aluminum & Plastic Enclosures Tx Frequency Range: 806 - 821 MHz Rx Frequency Range: 851 - 870 MHz Rated RF Output Power: 2.65 Watts (ERP) Frequency Tolerance: 2.5 PPM Emission Designator: 20K0F1D Antenna Type: Permanent Stud-Mount ¼-Wave Whip CELLTECH RESEARCH INC. Test Report S/N: 011402-197P5I 1955 Moss Court, Kelowna Test Dates: January 22-24, 2002 B.C. Canada V1Y 9L3 FCC Part 90 Certification ________________________________________________________________________________…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Darryl Strucko(P.E., Sr. Systems Engineer)
[email protected]703-262-4021Fax: 703-262-0380

Technical Contact

Celltech Research Inc.Jon Hughes
[email protected]250-860-3130

1955 Moss Court · Kelowna, B.C. · Canada

Non-Technical Contact

Celltech Research Inc.Jon Hughes
[email protected]250-860-3130

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
190806 MHz - 821 MHz2.65 W20K0F1D2.5000000000 ppm
Confidentiality
Long Term

Other Applications from Wireless Matrix Corporation

Mobile base station with L-Band Sat, GSM and WLAN - FCC ID P5IMBS2LPE - Wireless Matrix Corporation
P5IMBS2LPE

Mobile base station with L-Band Sat, GSM and WLAN

Dec 10, 2006

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
Satellite Earth Station Equipment - FCC ID P5ISDT5 - Wireless Matrix Corporation
P5ISDT5

Satellite Earth Station Equipment

Dec 21, 2005

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
Mobile base station with L-Band Sat, GSM and WLAN - FCC ID P5IMBS2LP - Wireless Matrix Corporation
P5IMBS2LP

Mobile base station with L-Band Sat, GSM and WLAN

Nov 18, 2005

Equipment Class

PCB - PCS Licensed Transmitter
Mobile base station with L-Band Sat, GSM and WLAN - FCC ID P5IMBS2A - Wireless Matrix Corporation
P5IMBS2A

Mobile base station with L-Band Sat, GSM and WLAN

Mar 25, 2004

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter