FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shanghai Junsun Lighting Co., Ltd./
  3. P97JUNSUN0208

P97JUNSUN0208Self-Ballasted Lamp

Shanghai Junsun Lighting Co., Ltd.
Self-Ballasted Lamp - FCC ID P97JUNSUN0208 - Shanghai Junsun Lighting Co., Ltd.
Click to zoom

Application Details

Equipment Class
8CC - Part 18 Consumer Device
Date of Grant
Apr 04, 2002
Application Purpose
Original Equipment
Date of Application
Apr 04, 2002
Equipment Note
Self-Ballasted Lamp
Frequency Range
0.04100000 - 0.04500000
Company
Shanghai Junsun Lighting Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Schematics

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

U SER ’ S M ANUAL

External Photos

F IGURE 1 S ELF-BALLASTED LAMP (M/N: JAD SERIES) G ENERAL A PPEARANCE F IGURE 2 S ELF-BALLASTED LAMP (M/N: JBS SERIES) GENERAL APPEARANCE F IGURE 3 S ELF-BALLASTED LAMP (M/N: JBT SERIES) G ENERAL A PPEARANCE F IGURE 4 S ELF-BALLASTED LAMP (M/N: JAD SERIES) COVER REMOVED F IGURE 5 E LECTRONIC ENERGY SAVING LAMP (M/N: JAD SERIES) M AIN B OARD (C OMPONENT S IDE ) F IGURE 6 E LECTRONIC ENERGY SAVING LAMP (M/N: JAD SERIES) MAIN BOARD (SOLDERED SIDE) Figure 7 S ELF-BALLASTED LAMP (M/N: JBS SERIES) C OVER R EMOVED FIGURE 8 E LECTRONIC E NERGY S AVING L AMP (M/N: JBS S ERIES ) M AIN BOARD (COMPONENT SIDE) F IGURE 9 E LECTRONIC ENERGY SAVING LAMP (M/N: JBS SERIES) M AIN B OARD (S OLDERED S IDE ) F IGURE 10 S ELF-BALLASTED LAMP (M/N: JBT SERIES) COVER REMOVED F IGURE 11 E LECTRONIC ENERGY SAVING LAMP (M/N: JBT SERIES) M AIN B OARD (C OMPONENT S IDE ) F IGURE 12 E LECTRONIC ENERGY SAVING LAMP (M/N: JBT SERIES) MAIN BOARD (SOLDERED SIDE)

ID Label/Location Info

Label Drawing 1. For example: Note:The blue words will be replaced as follows for each model. JAD-11 11W 120V 60Hz 175mA Self-Ballasted Lamp FCC ID: P97JUNSUN0208 CAUTION: Risk of electric shock-Use in dry location only. Not for use with dimmers. Not for use in totally enclosed recessed fixtures. Not for use where exposed to the weather.

ID Label/Location Info

Label Location Information Refer to the below red arrow: (for example)

Internal Photos

F IGURE 1 S ELF -B ALLASTED L AMP (M/N: JAD S ERIES ) C OVER R EMOVED F IGURE 2 E LECTRONIC E NERGY S AVING L AMP (M/N: JAD S ERIES ) M AIN B OARD (C OMPONENT S IDE ) F IGURE 3 E LECTRONIC E NERGY S AVING L AMP (M/N: JAD S ERIES ) M AIN B OARD (S OLDERED S IDE ) Figure 4 S ELF -B ALLASTED L AMP (M/N: JBS S ERIES ) C OVER R EMOVED F IGURE 5 E LECTRONIC E NERGY S AVING L AMP (M/N: JBS S ERIES ) M AIN B OARD (C OMPONENT S IDE ) F IGURE 6 E LECTRONIC E NERGY S AVING L AMP (M/N: JBS S ERIES ) M AIN B OARD (S OLDERED S IDE ) F IGURE 7 S ELF -B ALLASTED L AMP (M/N: JBT S ERIES ) C OVER R EMOVED F IGURE 8 E LECTRONIC E NERGY S AVING L AMP (M/N: JBT S ERIES ) M AIN B OARD (C OMPONENT S IDE ) F IGURE 9 E LECTRONIC E NERGY S AVING L AMP (M/N: JBT S ERIES ) M AIN B OARD (S OLDERED S IDE )

Schematics

Schematics

Test Report

Shanghai Junsun Lighting Co., Ltd. FCC ID: P97JUNSUN0208 Page 1 of 54 Audix Technology (Shanghai) Co., Ltd. Report No: ACI-F02031 Application for FCC Certificate On Behalf of Shanghai Junsun Lighting Co., Ltd. Self-Ballasted Lamp Model No.: JAD-5 JAD-7 JAD-9 JAD-11 JAD-13 JAD-15 JAD-18 JBT-11 JBT-13 JBT-15 JBT-18 JBT-20 JBT-23 JBT-25 JBS-15 JBS-18 JBS-20 JBS-23 JBS-25 FCC ID: P97JUNSUN0208 Prepared For : Shanghai Junsun Lighting Co., Ltd. Beiguan, Malu Town, Jiading, Shanghai, China Prepared By : Audix Technology (Shanghai) Co., Ltd. 3F 34Bldg 680 Guiping Rd, Caohejing Hi-Tech Park, Shanghai, China 200233 Tel : +86-21-64955500 Fax : +86-21-64955491 Report No. : ACI-F02031 Date of Test : Mar 13 ~ Mar 18, 2002 Date of Report : Mar 26, 2002 Shanghai Junsun Lighting Co., Ltd. FCC ID: P97JUNSUN0208 Page 2 of 54 Audix Technology (Shanghai) Co., Ltd. Report No: ACI-F02031 TABLE OF CONTENTS Page 1 GENERAL INFORMATION.......................................................................................................... 4 1.1 Description of Equipment Under Test........................................................................................4 1.2 Description of Test Facility ........................................................................................................ 5 1.3 Measurement Uncertainty .......................................................................................................... 5 2 AC POWERLINE CONDUCTED EMISSION TEST ................................................................. 6 2.1 Test Equipment........................................................................................................................... 6 2.2 Block Diagram of Test Setup ..................................................................................................... 6 2.3 Conducted Emission Limits ....................................................................................................... 6 2.4 Test Configuration...................................................................................................................... 7 2.5 Operating Condition of EUT ...................................................................................................... 7 2.6 Test Procedures .......................................................................................................................... 7 2.7 Test Results ................................................................................................................................ 7 3 FIELD STRENGTH TEST ........................................................................................................... 26 3.1 Test Equipment......................................................................................................................... 26 3.2 Block Diagram of Test Setup ................................................................................................... 26 3.3 Test Configuration.................................................................................................................... 26 3.4 Operating Condition of EUT .................................................................................................... 26 3.5 Test Procedure .......................................................................................................................... 27 3.6 Test Result ................................................................................................................................ 27 Shanghai Junsun Lighting Co., Ltd. FCC ID: P97JUNSUN0208 Page 3 of 54 Audix Technology (Shanghai) Co., Ltd. Report No: ACI-F02031 TEST REPORT FOR FCC CERTIFICATE Applicant : Shanghai Junsun Lighting Co., Ltd. Manufacturer : Shanghai Junsun Lighting Co., Ltd. EUT Description : Self-Ballasted Lamp (A) Model No.: JAD-5 JAD-7 JAD-9 JAD-11 JAD-13 JAD-15 JAD-18 JBT-11 JBT-13 JBT-15 JBT-18 JBT-20 JBT-23 JBT-25 JBS-15 JBS-18 JBS-20 JBS-23 JBS-25 (B) Serial No.: N/A (C) Power Supply: 120V/60Hz Test Procedure Used: FCC RULES AND REGULATIONS PART 18 CONSUMER DEVICES (2000) AND MP-5/1986 The device described above is tested by Audix Technology (Shanghai) Co., Ltd. to determine the maximum emission levels emanating from the device. The maximum emission levels are compared to the FCC Part 18 RF Lighting Device limits both conducted emissions and field strength. The test results are contained in this test report and Audix Technology (Shanghai) Co., Ltd. is assumed full responsibility for the accuracy and completeness of these measurements. Also, this report shows that the EUT to be technically compliant with the FCC official limits. This report applies to above tested sample only. This report shall not be reproduced in part without written approval of Audix Technology (Shanghai) Co., Ltd. This report must not be used by the applicant to claim product endorsement by NVLAP or any agency of the U.S. Government. Date of Test : Mar 13 ~ Mar 18, 2002 Prepared by : Test Engineer : CASPER LEI (Supervisor) WINSTON HUA (Engineer) Reviewer : Approved Signatory : BYRON KWO (Supervisor) ALEX CHIU (Assistant Manager) Shanghai Junsun Lighting Co., Ltd. FCC ID: P97JUNSUN0208 Page 4 of 54 Audix Technology (Shanghai) Co., Ltd. Report No: ACI-F02031 1 GENERAL INFORMATION 1.1 Description of Equipment Under Test Description : Self-Ballasted Lamp Type of EUT : ; Production … Pre-product … Pro-type Model Number : JAD-5 JAD-7 JAD-9 JAD-11 JAD-13 JAD-15 JAD-18 JBT-11 JBT-13 JBT-15 JBT-18 JBT-20 JBT-23 JBT-25 JBS-15 JBS-18 JBS-20 JBS-23 JBS-25 (All the above models were tested, and only the test data of JAD-5, JAD-11, JAD-18, JBT-11, JBT-18, JBT-25, JBS-15, JBS-20, JBS-25 are recorded in this report.) Applicant : Shanghai Junsun Lighting Co., Ltd. Beiguan, Malu Town, Jiading, Shanghai, China Manufacturer : Shanghai Junsun Lighting Co., Ltd. Beiguan, Malu Town, Jiading, Shanghai, China M/N Apparent Power (VA) Real Power (W) JAD-5 13.1 6.0 JAD-7 14.6 7.0 JAD-9 17.4 8.7 JAD-11 19.4 10.1…

Text truncated - open the document above for the full version.

Test Report

Shanghai Junsun Lighting Co., Ltd. FCC ID: P97JUNSUN0208 Page 28 of 54 Audix Technology (Shanghai) Co., Ltd. Report No: ACI-F02031 Shanghai Junsun Lighting Co., Ltd. FCC ID: P97JUNSUN0208 Page 29 of 54 Audix Technology (Shanghai) Co., Ltd. Report No: ACI-F02031 Shanghai Junsun Lighting Co., Ltd. FCC ID: P97JUNSUN0208 Page 30 of 54 Audix Technology (Shanghai) Co., Ltd. Report No: ACI-F02031 Shanghai Junsun Lighting Co., Ltd. FCC ID: P97JUNSUN0208 Page 31 of 54 Audix Technology (Shanghai) Co., Ltd. Report No: ACI-F02031 Shanghai Junsun Lighting Co., Ltd. FCC ID: P97JUNSUN0208 Page 32 of 54 Audix Technology (Shanghai) Co., Ltd. Report No: ACI-F02031 Shanghai Junsun Lighting Co., Ltd. FCC ID: P97JUNSUN0208 Page 33 of 54 Audix Technology (Shanghai) Co., Ltd. Report No: ACI-F02031 Shanghai Junsun Lighting Co., Ltd. FCC ID: P97JUNSUN0208 Page 34 of 54 Audix Technology (Shanghai) Co., Ltd. Report No: ACI-F02031 Shanghai Junsun Lighting Co., Ltd. FCC ID: P97JUNSUN0208 Page 35 of 54 Audix Technology (Shanghai) Co., Ltd. Report No: ACI-F02031 Shanghai Junsun Lighting Co., Ltd. FCC ID: P97JUNSUN0208 Page 36 of 54 Audix Technology (Shanghai) Co., Ltd. Report No: ACI-F02031 Shanghai Junsun Lighting Co., Ltd. FCC ID: P97JUNSUN0208 Page 37 of 54 Audix Technology (Shanghai) Co., Ltd. Report No: ACI-F02031 Shanghai Junsun Lighting Co., Ltd. FCC ID: P97JUNSUN0208 Page 38 of 54 Audix Technology (Shanghai) Co., Ltd. Report No: ACI-F02031 Shanghai Junsun Lighting Co., Ltd. FCC ID: P97JUNSUN0208 Page 39 of 54 Audix Technology (Shanghai) Co., Ltd. Report No: ACI-F02031 Shanghai Junsun Lighting Co., Ltd. FCC ID: P97JUNSUN0208 Page 40 of 54 Audix Technology (Shanghai) Co., Ltd. Report No: ACI-F02031 Shanghai Junsun Lighting Co., Ltd. FCC ID: P97JUNSUN0208 Page 41 of 54 Audix Technology (Shanghai) Co., Ltd. Report No: ACI-F02031 Shanghai Junsun Lighting Co., Ltd. FCC ID: P97JUNSUN0208 Page 42 of 54 Audix Technology (Shanghai) Co., Ltd. Report No: ACI-F02031 Shanghai Junsun Lighting Co., Ltd. FCC ID: P97JUNSUN0208 Page 43 of 54 Audix Technology (Shanghai) Co., Ltd. Report No: ACI-F02031 Shanghai Junsun Lighting Co., Ltd. FCC ID: P97JUNSUN0208 Page 44 of 54 Audix Technology (Shanghai) Co., Ltd. Report No: ACI-F02031 Shanghai Junsun Lighting Co., Ltd. FCC ID: P97JUNSUN0208 Page 45 of 54 Audix Technology (Shanghai) Co., Ltd. Report No: ACI-F02031 Shanghai Junsun Lighting Co., Ltd. FCC ID: P97JUNSUN0208 Page 46 of 54 Audix Technology (Shanghai) Co., Ltd. Report No: ACI-F02031 Shanghai Junsun Lighting Co., Ltd. FCC ID: P97JUNSUN0208 Page 47 of 54 Audix Technology (Shanghai) Co., Ltd. Report No: ACI-F02031 Shanghai Junsun Lighting Co., Ltd. FCC ID: P97JUNSUN0208 Page 48 of 54 Audix Technology (Shanghai) Co., Ltd. Report No: ACI-F02031 Shanghai Junsun Lighting Co., Ltd. FCC ID: P97JUNSUN0208 Page 49 of 54 Audix Technology (Shanghai) Co., Ltd. Report No: ACI-F02031 Shanghai Junsun Lighting Co., Ltd. FCC ID: P97JUNSUN0208 Page 50 of 54 Audix Technology (Shanghai) Co., Ltd. Report No: ACI-F02031 Shanghai Junsun Lighting Co., Ltd. FCC ID: P97JUNSUN0208 Page 51 of 54 Audix Technology (Shanghai) Co., Ltd. Report No: ACI-F02031 Shanghai Junsun Lighting Co., Ltd. FCC ID: P97JUNSUN0208 Page 52 of 54 Audix Technology (Shanghai) Co., Ltd. Report No: ACI-F02031 Shanghai Junsun Lighting Co., Ltd. FCC ID: P97JUNSUN0208 Page 53 of 54 Audix Technology (Shanghai) Co., Ltd. Report No: ACI-F02031 Shanghai Junsun Lighting Co., Ltd. FCC ID: P97JUNSUN0208 Page 54 of 54 Audix Technology (Shanghai) Co., Ltd. Report No: ACI-F02031

Test Setup Photos

Test Set-Up Photos 1. Conducted Emission Test 2. Field strength Test

Contact Information

Applicant

Jianhua Liao(V. G. Manager)
[email protected]+886-021-69155021-16Fax: +886-021-69155014

Test Firm

Audix Technology ( Shanghai ) Co., Ltd.Byron Kwo
[email protected]021-6495-5500Fax: 021-6495-5491

Technical Specifications

#Rule PartsFrequency RangePower Output
1180.041 MHz - 0.045 MHz-

Other Applications from Shanghai Junsun Lighting Co., Ltd.

Energy Saving Lamp - FCC ID P97JUNSUN0211 - Shanghai Junsun Lighting Co., Ltd.
P97JUNSUN0211

Energy Saving Lamp

Nov 13, 2002

Equipment Class

8CC - Part 18 Consumer Device
Energy Saving Lamp - FCC ID P97JUNSUN0210 - Shanghai Junsun Lighting Co., Ltd.
P97JUNSUN0210

Energy Saving Lamp

Oct 24, 2002

Equipment Class

8CC - Part 18 Consumer Device