User’s Manual This light device has been tested and found to comply with the limits for Consumer RF Lighting device, pursuant to Part 18 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. 1 Use only on 120V/60Hz. 2 Never disassemble or modify-any changes could void the user’ authority to operate this device. 3 Not for use in totally enclosed recessed fixtures. 4 Risk of electric shock-do not use with where directly exposed to weather. 5 This device is not intended for use with emergency exit fixtures or emergency exit lights. 6 This product may cause interference to radio equipment and should not be installed near maritime safety communications equipment or other critical navigation or communication equipment operating between 0.45-30MHz. 7 To prevent burns, do not touch the bulb burning operation or immediately after switching off. 8 Not for use with dimmers, electronic timer or photocell devices or occupancy sensor. 9 It does not start up when placed below -15°C. 10 “Added weight any cause instability of free-standing portable lamps. Use only with portable lamps in which the distance from the bottom of the base to the top of the lamp holder does not exceed three (3) times minimum base width. Use only with portable table lamps which are provided with lamp shades.”
F IGURE 1 E NERGY S AVING L AMP (M/N: JLG-18W) G ENERAL A PPEARANCE F IGURE 2 E NERGY S AVING L AMP (M/N: JLG-20W) G ENERAL A PPEARANCE F IGURE 3 E NERGY S AVING L AMP (M/N: JLG-23W) G ENERAL A PPEARANCE F IGURE 4 E NERGY S AVING L AMP (M/N: JLG-25W) G ENERAL A PPEARANCE F IGURE 5 E NERGY S AVING L AMP (M/N: JLQ-18W) G ENERAL A PPEARANCE F IGURE 6 E NERGY S AVING L AMP (M/N: JLQ-20W) G ENERAL A PPEARANCE F IGURE 7 E NERGY S AVING L AMP (M/N: JLQ-23W) G ENERAL A PPEARANCE F IGURE 8 E NERGY S AVING L AMP (M/N: JLQ-25W) G ENERAL A PPEARANCE F IGURE 9 E NERGY S AVING L AMP (M/N: JLR-18W) G ENERAL A PPEARANCE F IGURE 10 E NERGY S AVING L AMP (M/N: JLR-20W) G ENERAL A PPEARANCE F IGURE 11 E NERGY S AVING L AMP (M/N: JLR-23W) G ENERAL A PPEARANCE F IGURE 12 E NERGY S AVING L AMP (M/N: JLR-25W) G ENERAL A PPEARANCE
Label Drawing 1. For example: Note:The blue words will be replaced as follows for each model. Model Label JLG-18W JLG-18W 120V 60Hz 220 mA JLG-20W JLG-20W 120V 60Hz 270 mA JLG-23W JLG-23W 120V 60Hz 290 mA JLG-25W JLG-25W 120V 60Hz 320 mA JLQ-18W JLQ-18W 120V 60Hz 220 mA JLQ-20W JLQ-20W 120V 60Hz 270 mA JLQ-23W JLQ-23W 120V 60Hz 290 mA JLQ-25W JLQ-25W 120V 60Hz 320 mA JLR-18W JLR-18W 120V 60Hz 220 mA JLR-20W JLR-20W 120V 60Hz 270 mA JLR-23W JLR-23W 120V 60Hz 290 mA JLR-25W JLR-25W 120V 60Hz 320 mA JLG-18W 120V 60Hz 220mA Energy Saving Lamp FCC ID: P97JUNSUN0211 CAUTION: Risk of electric shock-Use in dry location only. Not for use with dimmers. Not for use in totally enclosed recessed fixtures. Not for use where exposed to the weather.
Label Location Information Refer to the below red arrow: (For example) JLG-18W 120V 60Hz 220mA
F IGURE 1 E NERGY S AVING L AMP (M/N: JLG-18W) C OVER R EMOVED F IGURE 2 E NERGY S AVING L AMP (M/N: JLG-18W) M AIN B OARD (C OMPONENT S IDE ) F IGURE 3 E NERGY S AVING L AMP (M/N: JLG-18W) M AIN B OARD (S OLDERED S IDE ) F IGURE 4 E NERGY S AVING L AMP (M/N: JLG-20W) C OVER R EMOVED F IGURE 5 E NERGY S AVING L AMP (M/N: JLG-20W) M AIN B OARD (C OMPONENT S IDE ) F IGURE 6 E NERGY S AVING L AMP (M/N: JLG-20W) M AIN B OARD (S OLDERED S IDE ) F IGURE 7 E NERGY S AVING L AMP (M/N: JLG-23W) C OVER R EMOVED F IGURE 8 E NERGY S AVING L AMP (M/N: JLG-23W) M AIN B OARD (C OMPONENT S IDE ) F IGURE 9 E NERGY S AVING L AMP (M/N: JLG-23W) M AIN B OARD (S OLDERED S IDE ) F IGURE 10 E NERGY S AVING L AMP (M/N: JLG-25W) C OVER R EMOVED F IGURE 11 E NERGY S AVING L AMP (M/N: JLG-25W) M AIN B OARD (C OMPONENT S IDE ) F IGURE 12 E NERGY S AVING L AMP (M/N: JLG-25W) M AIN B OARD (S OLDERED S IDE ) F IGURE 13 E NERGY S AVING L AMP (M/N: JLQ-18W) C OVER R EMOVED F IGURE 14 E NERGY S AVING L AMP (M/N: JLQ-18W) M AIN B OARD (C OMPONENT S IDE ) F IGURE 15 E NERGY S AVING L AMP (M/N: JLQ-18W) M AIN B OARD (S OLDERED S IDE ) F IGURE 16 E NERGY S AVING L AMP (M/N: JLQ-20W) C OVER R EMOVED F IGURE 17 E NERGY S AVING L AMP (M/N: JLQ-20W) M AIN B OARD (C OMPONENT S IDE ) F IGURE 18 E NERGY S AVING L AMP (M/N: JLQ-20W) M AIN B OARD (S OLDERED S IDE ) F IGURE 19 E NERGY S AVING L AMP (M/N: JLQ-23W) C OVER R EMOVED F IGURE 20 E NERGY S AVING L AMP (M/N: JLQ-23W) M AIN B OARD (C OMPONENT S IDE ) F IGURE 21 E NERGY S AVING L AMP (M/N: JLQ-23W) M AIN B OARD (S OLDERED S IDE ) F IGURE 22 E NERGY S AVING L AMP (M/N: JLQ-25W) C OVER R EMOVED F IGURE 23 E NERGY S AVING L AMP (M/N: JLQ-25W) M AIN B OARD (C OMPONENT S IDE ) F IGURE 24 E NERGY S AVING L AMP (M/N: JLQ-25W) M AIN B OARD (S OLDERED S IDE ) F IGURE 25 E NERGY S AVING L AMP (M/N: JLR-18W) C OVER R EMOVED F IGURE 26 E NERGY S AVING L AMP (M/N: JLR-18W) M AIN B OARD (C OMPONENT S IDE ) F IGURE 27 E NERGY S AVING L AMP (M/N: JLR-18W) M AIN B OARD (S OLDERED S IDE ) F IGURE 28 E NERGY S AVING L AMP (M/N: JLR-20W) C OVER R EMOVED F IGURE 29 E NERGY S AVING L AMP (M/N: JLR-20W) M AIN B OARD (C OMPONENT S IDE ) F IGURE 30 E NERGY S AVING L AMP (M/N: JLR-20W) M AIN B OARD (S OLDERED S IDE ) F IGURE 31 E NERGY S AVING L AMP (M/N: JLR-23W) C OVER R EMOVED F IGURE 32 E NERGY S AVING L AMP (M/N: JLR-23W) M AIN B OARD (C OMPONENT S IDE ) F IGURE 33 E NERGY S AVING L AMP (M/N: JLR-23W) M AIN B OARD (S OLDERED S IDE ) F IGURE 34 E NERGY S AVING L AMP (M/N: JLR-25W) C OVER R EMOVED F IGURE 35 E NERGY S AVING L AMP (M/N: JLR-25W) M AIN B OARD (C OMPONENT S IDE ) F IGURE 36 E NERGY S AVING L AMP (M/N: JLR-25W) M AIN B OARD (S OLDERED S IDE )
Schematics
Shanghai Junsun Lighting Co., Ltd. FCC ID: P97JUNSUN0211 Page 1 of57 Audix Technology (Shanghai) Co., Ltd. Report No: ACI-F02103 Application for FCC Certificate On Behalf of Shanghai Junsun Lighting Co., Ltd. Energy Saving Lamp Model No.: JLG-18W JLG-20W JLG-23W JLG-25W JLQ-18W JLQ-20W JLQ-23W JLQ-25W JLR-18W JLR-20W JLR-23W JLR-25W FCC ID: P97JUNSUN0211 Prepared For : Shanghai Junsun Lighting Co., Ltd. Beiguan, Malu town , Jiading, Shanghai, China. Prepared By : Audix Technology (Shanghai) Co., Ltd. 3F 34Bldg 680 Guiping Rd, Caohejing Hi-Tech Park, Shanghai, China 200233. Tel : +86-21-64955500 Fax : +86-21-64955491 Report No. : ACI-F02103 Date of Test : Sep 17~ Oct 25, 2002 Date of Report : Oct 21, 2002 Shanghai Junsun Lighting Co., Ltd. FCC ID: P97JUNSUN0211 Page 2 of57 Audix Technology (Shanghai) Co., Ltd. Report No: ACI-F02103 TABLE OF CONTENTS Page 1 GENERAL INFORMATION.......................................................................................................... 4 1.1 Description of Equipment Under Test........................................................................................4 1.2 Description of Test Facility ........................................................................................................ 5 1.3 Measurement Uncertainty .......................................................................................................... 5 2 AC POWERLINE CONDUCTED EMISSION TEST ................................................................. 6 2.1 Test Equipment........................................................................................................................... 6 2.2 Block Diagram of Test Setup ..................................................................................................... 6 2.3 Conducted Emission Limits ....................................................................................................... 6 2.4 Test Configuration...................................................................................................................... 7 2.5 Operating Condition of EUT ...................................................................................................... 7 2.6 Test Procedures .......................................................................................................................... 7 2.7 Test Results ................................................................................................................................ 8 3 FIELDSTRENGTH TEST ............................................................................................................ 20 3.1 Test Equipment......................................................................................................................... 20 3.2 Block Diagram of Test Setup ................................................................................................... 20 3.3 Test Configuration.................................................................................................................... 20 3.4 Operating Condition of EUT .................................................................................................... 20 3.5 Test Procedure .......................................................................................................................... 21 3.6 Test Result ................................................................................................................................ 21 Shanghai Junsun Lighting Co., Ltd. FCC ID: P97JUNSUN0211 Page 3 of57 Audix Technology (Shanghai) Co., Ltd. Report No: ACI-F02103 TEST REPORT FOR FCC CERTIFICATE Applicant : Shanghai Junsun Lighting Co., Ltd. Manufacturer : Shanghai Junsun Lighting Co., Ltd. EUT Description : Energy Saving Lamp (A) Model No.: JLG-18W; JLG-20W; JLG-23W; JLG-25W JLQ-18W; JLQ-20W; JLQ-23W; JLQ-25W JLR-18W; JLR-20W; JLR-23W; JLR-25W (B) Serial No.: E02091601; E02091602; E02091603; E02091604 E02091609; E02091610; E02091611; E02091612 E02091605; E02091606; E02091607; E02091608 (C) Power Supply: 120V/60Hz Test Procedure Used: FCC RULES AND REGULATIONS PART 18 CONSUMER DEVICES (2000) AND MP-5/1986 The device described above is tested by Audix Technology (Shanghai) Co., Ltd. to determine the maximum emission levels emanating from the device. The maximum emission levels are compared to the FCC Part 18 RF Lighting Device limits both conducted emissions and field strength. The test results are contained in this test report and Audix Technology (Shanghai) Co., Ltd. is assumed full responsibility for the accuracy and completeness of these measurements. Also, this report shows that the EUT to be technically compliant with the FCC official limits. This report applies to above tested sample only. This report shall not be reproduced in part without written approval of Audix Technology (Shanghai) Co., Ltd. This report must not be used by the applicant to claim product endorsement by NVLAP or any agency of the U.S. Government. Date of Test : Sep 17~19, 2002 Prepared by : Test Engineer : CATHRIN YIN (Assistant) COFFON YE (Engineer) Reviewer : Approved Signatory : BYRON KWO (Supervisor) ALEX CHIU (Assistant Manager) Shanghai Junsun Lighting Co., Ltd. FCC ID: P97JUNSUN0211 Page 4 of57 Audix Technology (Shanghai) Co., Ltd. Report No: ACI-F02103 1 GENERAL INFORMATION 1.1 Description of Equipment Under Test Description : Energy Saving Lamp Type of EUT : ; Production Pre-product Pro-type Model Number : JLG-18W; JLG-20W; JLG-23W; JLG-25W JLQ-18W; JLQ-20W; JLQ-23W; JLQ-25W JLR-18W; JLR-20W; JLR-23W; JLR-25W The three Serial products are all same, only except the shade. In this report, all the products were tested and reported. Applicant : Shanghai Junsun Lighting Co., Ltd. Beiguan, Malu town, Jiading, Shanghai, China. Manufacturer : Shanghai Junsun Lighting Co., Ltd. Beiguan, Malu town, Jiading, Shanghai, China. Test Model Apparent Power (V ̇ A) Real Power (W) JLG-18W 33.70 19.50 JLG-20W 43.10 24.70 JLG-23W 50.40 29.30 …
Text truncated - open the document above for the full version.
Test Set-Up Photos 1. Conducted Emission Test (M/N: JLG-18W) (M/N: JLG-20W) (M/N: JLG-23W) (M/N: JLG-25W) (M/N: JLQ-18W) (M/N: JLQ-20W) (M/N: JLQ-23W) (M/N: JLQ-25W) (M/N: JLR-18W) (M/N: JLR-20W) (M/N: JLR-23W) (M/N: JLR-25W) 2. Field strength Test (M/N: JLG-18W) (M/N: JLG-20W) (M/N: JLG-23W) (M/N: JLG-25W) (M/N: JLQ-18W) (M/N: JLQ-20W) (M/N: JLQ-23W) (M/N: JLQ-25W) (M/N: JLR-18W) (M/N: JLR-20W) (M/N: JLR-23W) (M/N: JLR-25W)
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 18 | 0.041 MHz - 0.045 MHz | - |

Energy Saving Lamp
Equipment Class
8CC - Part 18 Consumer Device
Self-Ballasted Lamp
Equipment Class
8CC - Part 18 Consumer Device