FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Eaton's Cooper Power Systems/
  3. P9X-420CL1W

P9X-420CL1WUtility Meter Reading Transmitter

Eaton's Cooper Power Systems
Utility Meter Reading Transmitter - FCC ID P9X-420CL1W - Eaton's Cooper Power Systems
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Jan 09, 2013
Application Purpose
Original Equipment
Date of Application
Jan 08, 2013
Equipment Note
Utility Meter Reading Transmitter
Frequency Range
902.75000000 - 927.25000000
Company
Eaton's Cooper Power Systems
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

RFN420CL (1W) User’s Guide Document Number XXXX Revision 1 Cooper Power Systems 910 Clopper Road, Suite 201S Gaithersburg, MD 20878 USA www.cooperpowereas.com Tel (301) 515-7118 Fax: (301) 515-4965 XXXXX-01 2 RFN420CL (1W) User’s Guide Contents 1 About the RFN420CL (1W) .................................................................................................................... 3 2 Regulatory Notices................................................................................................................................. 4 3 RFN420CL (1W) Specifications ............................................................................................................. 7 XXXXX-01 3 RFN420CL (1W) User’s Guide 1 About the RFN420CL (1W) The RFN420CL (1W) is a radio communications device designed for use in Itron C2SX meters. It can also be used in Cooper Power Systems Gateways and Relay Nodes. The RFN420CL (1W) provides a 915 MHz radio interface to an RF mesh network, and a ZigBee interface for HAN applications. The RFN420CL (1W) operates from a power source of 5.0 VDC, received from the host device. The radio modules operate in license-free bands at either 915 MHz (902.75 to 927.25 MHz) or 2400 MHz (2405 to 2480 MHz). RFN420CL (1W) Nodes are fully compatible with mesh network hardware, protocols and operations. Two radio transmission data rates are available: 38.4 kb/s, 76.8 kb/s and153.6 kb/s. The transmission power of the 915 MHz radio is adjustable from 30 dBm to -20 dBm. The transmission power of the 2400 MHz radio is fixed at +20 dBm. XXXXX-01 4 RFN420CL (1W) User’s Guide 2 Regulatory Notices Warning The Original Equipment Manufacturer (OEM) must ensure that FCC Labeling requirements are met. This includes a clearly visible label on the outside of the OEM enclosure specifying the Cooper Power Systems FCC identifier (FCC ID: P9X-420CL1W) and IC Number (IC: 6766A-420CL1W) as well as the FCC Notice below. Warning This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Warning Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Warning Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Warning This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  Reorient or relocate the receiving antenna.  Increase the separation between the equipment and receiver.  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  Consult the dealer or an experienced radio/TV technician for help. XXXXX-01 5 RFN420CL (1W) User’s Guide Warning The installer of this radio equipment must ensure that the antenna is located or pointed such that it does not emit RF field in excess of Health Canada limits for the general population; consult Safety Code 6, obtainable from Health Canada’s website www.hc-sc.gc.ca/rpb. Warning To comply with FCC RF exposure compliance requirements, the antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operate in conjunction with any other antenna or transmitter.” As such, the radio component of this device is intended only for OEM integrators under the following two conditions: The antenna must be installed such that 20 cm is maintained between the antenna and users. The transmitter module may not be co-located with any other transmitter or antenna. As long as the two conditions above are met, further transmitter testing will not be required. However, the OEM integrator is still responsible for testing their end product for any additional compliance requirements required with this module installed (e.g., digital device emissions, PC peripheral requirements). In the event that these conditions cannot be met (for example, co-location with another transmitter), then the FCC authorization is no longer considered valid and the FCC ID cannot be used on the final product. In these circumstances, the OEM integrator will be responsible for re-evaluating the end product (including the transmitter) and obtaining a separate FCC authorization. End Product Labeling This transmitter module is authorized only for use in devices where the antenna may be installed such that 20 cm may be maintained between the antenna and users (for example access points, routers, wireless ASDL modems, certain laptop configurations, and similar equipment). The final end product must be labeled in a visible area with the following: “Contains FCC ID: P9X-420CL1W, IC: 6766A-420CL1W”. The radio component is an integral part of the RFN420CL (1W) and cannot be removed. XXXXX-01 6 RFN420CL (1W) User’s Guide Warning Transmi…

Text truncated - open the document above for the full version.

Cover Letter(s)

910 Clopper Road ● Suite 201S ● Gaithersburg, MD 20878 ● Tel. (301) 515 7118 ● Fax (301) 515 4965 ● www.coopereas.com Subject: Modular Approval Request FCC ID: P9X-420CL1W December 11, 2012 Dear Application Examiner: Cooper Power Systems, model RFN420CL (1W), FCC ID P9X-420CL1W, would like to have your authorization as a modular approval. The requirements of Public Notice DA00-1407 have been met and shown on the following statements. 1. "The modular transmitter must have its own RF shielding." - The radio portion of this module has been shielded. Please see exhibition External Photo. 2. "The modular transmitter must have buffered modulation/data inputs." – The RFN420CL (1W) contains buffered data inputs; it is integrated into Cooper Power System's RF design. 3. "The modular transmitter must have its own power supply regulation." - The RFN420CL (1W) contains a regulator in the DC input port; it is integrated into Cooper Power Systems’ RFN420CL (1W) design. 4. "The modular transmitter must comply with the antenna requirements of section 15.203 and 15.204(c)." - The RFN420CL (1W) meets the FCC antenna requirements. The spurious emission, unique antenna connector and photo of antennas are shown in the application exhibits. 5. "The modular transmitter must be tested in a stand-alone configuration." - The RFN420CL (1W) was tested in a stand-alone configuration via an adapter board. Please see exhibit "Test Setup Photos". 6. "The modular transmitter must be labeled with its own FCC ID number." - Please see exhibit "FCC Label" for the FCC to of this module. 7. "The modular transmitter must comply with any specific rule or operating requirements applicable to the transmitter and the manufacturer must provide adequate instructions along with the module to explain any such requirements." - The RFN420CL (1W) is compliant with all applicable FCC rules. Detailed instructions for maintaining compliance are given in the Users Manual. 8. "The modular transmitter must comply with any applicable RF exposure requirements." - The RFN420CL (1W) is compliant with all applicable RF exposure requirements. RF Exposure is addressed in the exhibit "MPE Data". Please contact me if you have any further questions. Thank you for your attention. Sincerely, Steven Seymour Certification Engineer Cooper Power Systems (240) 454-9845 [email protected]

Cover Letter(s)

910 Clopper Road. ● Suite 201S ● Gaithersburg, MD 20874 ● Tel. (301) 515 7118 ● Fax (301) 515 4965 ● www.coopereas.com December 11, 2012 Federal Communications Commission Office of Engineering and Technology Equipment Authorization Division 7345 Oakland Mills Road Columbia, MD 21046 RE: Certification Application FCC ID: P9X-420CL1W We, Cooper Power Systems in Gaithersburg, Maryland, attest that the RFN420CL (1W) is intended to be used only in electric metering products being sold by Cooper Power Systems and its affiliates. It will not be resold to other OEMs or other vendors. Sincerely, Steven Seymour Certification Engineer Cooper Power Systems (240) 454-9845 [email protected]

Cover Letter(s)

910 Clopper Road ● Suite 201S ● Gaithersburg, MD 20878 ● Tel. (301) 515 7118 ● Fax (301) 515 4965 ● www.coopereas.com December 11, 2012 American Certification Body Inc. 6731 Whittier Avenue McLean, VA 22101 To Whom It May Concern: Please be advised that Cooper Power Systems in Germantown, Maryland authorizes Washington Laboratories, Ltd. to act on our behalf, until otherwise notified, for applications submitted to American Telecommunications Certification Body, Inc. (ATCB). The following personnel of Washington Laboratories, Ltd. are authorized:  Michael F. Violette, President  Steven D. Koster, EMC Operations Manager We certify that we are not subject to denial of federal benefits, which includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse ACT of 1988, U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002(b), to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you for your attention to this matter. Sincerely, Steven Seymour Certification Engineer Cooper Power Systems (240) 454-9845 [email protected]

Cover Letter(s)

910 Clopper Road ● Suite 201S ● Gaithersburg, MD 20878 ● Tel. (301) 515 7118 ● Fax (301) 515 4965 ● www.coopereas.com January 8, 2013 Federal Communications Commission Office of Engineering and Technology Equipment Authorization Division 7345 Oakland Mills Road Columbia, MD 21046 RE: Certification Application FCC ID: P9X-420CL1W Please be advised that under the provision of 47 CFR 0.457 and 0.459 the following exhibits are to be held confidential on behalf of Cooper Power Systems: • Schematics (RFN420CL Schematic.pdf) • Bill of Materials (RFN420CL (1W) BOM.pdf) • Block diagram (RFN420CL (1W) Block Diagram.pdf) • Theory of Operation/Technical Description (RFN420CL (1W) Circuit Description and Operation.pdf and RFN420CL (1W) Circuit Description and Operation - Appendix.pdf) Rationale for request for confidentiality: Cooper Power Systems wishes to keep these items confidential to maintain a competitive advantage in the marketplace. These items will always be professionally installed. In addition, the device will always be in a controlled, inaccessible environment and are not available to the general public. Sincerely, Steven Seymour Certification Engineer Cooper Power Systems (240) 454-9845 [email protected]

External Photos

Internal and External Photos ©2008 Washington Laboratories, Ltd FCC ID: P9X-420CL1W and IC: 6766A-420CL1W Internal and External Photos ©2008 Washington Laboratories, Ltd FCC ID: P9X-420CL1W and IC: 6766A-420CL1W Internal and External Photos ©2008 Washington Laboratories, Ltd FCC ID: P9X-420CL1W and IC: 6766A-420CL1W Internal and External Photos ©2008 Washington Laboratories, Ltd FCC ID: P9X-420CL1W and IC: 6766A-420CL1W Internal and External Photos ©2008 Washington Laboratories, Ltd FCC ID: P9X-420CL1W and IC: 6766A-420CL1W Internal and External Photos ©2008 Washington Laboratories, Ltd FCC ID: P9X-420CL1W and IC: 6766A-420CL1W

ID Label/Location Info

Cooper Power Systems Photos RFN420CL (1W) (Itron C2SX) December 11, 2012 4 Figure 4: RFN420CL (1W) – Label Detail

ID Label/Location Info

Cooper Power Systems Photos RFN420CL (1W) (Itron C2SX) December 11, 2012 3 Figure 3: RFN420CL (1W) – Top, shields removed

Internal Photos

Internal and External Photos ©2008 Washington Laboratories, Ltd FCC ID: P9X-420CL1W and IC: 6766A-420CL1W Internal and External Photos ©2008 Washington Laboratories, Ltd FCC ID: P9X-420CL1W and IC: 6766A-420CL1W Internal and External Photos ©2008 Washington Laboratories, Ltd FCC ID: P9X-420CL1W and IC: 6766A-420CL1W Internal and External Photos ©2008 Washington Laboratories, Ltd FCC ID: P9X-420CL1W and IC: 6766A-420CL1W Internal and External Photos ©2008 Washington Laboratories, Ltd FCC ID: P9X-420CL1W and IC: 6766A-420CL1W Internal and External Photos ©2008 Washington Laboratories, Ltd FCC ID: P9X-420CL1W and IC: 6766A-420CL1W

RF Exposure Info

Certificates and reports shall not be reproduced except in full, without the written permission of Washington Labs, Limited. Maximum Permissible Exposure Evaluation For the Cooper Power Systems RFN420CL(1W) MODULE FCC ID: P9X-420CL1W IC: 6766A-420CL1W December 12, 2012 WLL Report: 12764-MPE Prepared for: Cooper Power Systems 910 Clopper Rd. Ste 201S Gaithersburg, MD, 20878 Prepared by: WASHINGTON LABORATORIES, LTD. 7560 LINDBERGH DRIVE GAITHERSBURG, MARYLAND 20879 Testing Certificate AT-1448 Cooper Power Systems RFN420CL(1W) RF Exposure Test Report December 2012 WLL Report #12764-MPE - ii - © 2012 Washington Laboratories, Ltd. Maximum Permissible Exposure Evaluation For the Cooper Power Systems RFN420CL(1W) MODULE December 12, 2012 WLL Report # 12764-MPE Prepared by: James Ritter EMC Laboratory Manager Reviewed by: Steven D. Koster Vice President Cooper Power Systems RFN420CL(1W) RF Exposure Test Report December 2012 WLL Report #12764-MPE - iii - © 2012 Washington Laboratories, Ltd. Abstract This report has been prepared on behalf of Cooper Power Systems RFN420CL(1W) module to document the findings of the maximum permissible exposure evaluation on the Cooper Power Systems RFN420CL(1W) module. The purpose of this evaluation is to establish a minimum safe distance as per the RF exposure requirements as defined in FCC §1.1307, §1.1310 & Industry Canada RSS-102 issue 4. This report documents the results of testing to the requirements of:  CFR Title 47 Volume 1 Practice and Procedure; (1.1307) Environmental Assessments The Evaluation was performed by Washington Laboratories, Ltd, 7560 Lindbergh Drive, Gaithersburg, MD 20879. Washington Laboratories, Ltd. has been accepted as an EMC Conformity Assessment Body (CAB) under the United States/European Union Memorandum of Agreement. Washington Laboratories, Ltd. is accredited by ACLASS under Testing Certificate AT-1448. Revision History Reason Date Rev 0 Initial Release December 12, 2012 Cooper Power Systems RFN420CL(1W) RF Exposure Test Report December 2012 WLL Report #12764-MPE - iv - © 2012 Washington Laboratories, Ltd. Table of Contents Abstract .................................................................................................................................................................... ii 1 Introduction ................................................................................................................................................ 1 2 Requirements .............................................................................................................................................. 1 2.1 Transmitter Categories ............................................................................................................................. 1 2.2 Exposure Categories ................................................................................................................................ 2 3 Device Summary ......................................................................................................................................... 4 4 Radio Frequency Radiation Exposure Evaluation .................................................................................. 5 4.1 Duty Cycle Corrections ............................................................................................................................ 5 4.2 RF Exposure Results ................................................................................................................................ 5 5 Appendix A ................................................................................................................................................. 8 List of Tables Table 1: MPE Limits ..................................................................................................................................................3 Table 2: Device Summary of the RFN420CL(1W) MODULE .................................................................................4 Table 3: Transmitter MPE Calculation Summary ......................................................................................................6 Table 4: Zigbee Duty Cycle Calculations ..................................................................................................................8 Cooper Power Systems RFN420CL(1W) RF Exposure Test Report December 2012 WLL Report #12764-MPE - Page 1 of 9 - © 2012 Washington Laboratories, Ltd. 1 Introduction This report has been prepared on behalf of Cooper Power Systems RFN420CL(1W) module transmitter to show compliance with the RF exposure requirements as defined in FCC §1.1307. Testing supporting this evaluation was performed at Washington Laboratories, Ltd, 7560 Lindbergh Drive, Gaithersburg, MD 20879. Washington Laboratories, Ltd. has been accepted as an EMC Conformity Assessment Body (CAB) under the United States/European Union Memorandum of Agreement. Washington Laboratories, Ltd. is accredited with ACLASS under Testing Certificate AT-1448. 2 Requirements Three different categories of transmitters are defined by the FCC in OET Bulletin 65. These categories are fixed installation, mobile, and portable. Additionally, the FCC categorizes the use of the devices based on the user’s awareness and the ability to exercise control over his or her exposure. The two categories are defined as Occupational/Controlled Exposure and General Population/Uncontrolled Exposure. 2.1 Transmitter Categories 2.1.1 Fixed Installations A fixed location means that the device, including its antenna, is physically secured at a permanent location and is not able to be easily moved to another location. Additionally, distance to humans from the antenna is maintained to at least 2 meters. 2.1.2 Mobile Devices A mobile device is defined as a transmitting device designed to be used in other than fixed locations and to be generally used in such a way that a separation distance of at least 20 centimeters is normally maintained between th…

Text truncated - open the document above for the full version.

Test Report

Certificates and reports shall not be reproduced except in full, without the written permission of Washington Laboratories, Limited. FCC & Industry Canada Certification Test Report For the Cooper Power Systems RFN420CL(1W) MODULE FCC ID: P9X-420CL1W IC: 6766A-420CL1W WLL JOB# 12764 Rev.1 December 12, 2012 Re-issued January 3, 2013 Prepared for: Cooper Power Systems 910 Clopper Rd. Ste 201S Gaithersburg, MD, 20878 Prepared By: Washington Laboratories, Ltd. Washington Laboratories, Ltd.Washington Laboratories, Ltd. Washington Laboratories, Ltd. 7560 Lindbergh Drive 7560 Lindbergh Drive7560 Lindbergh Drive 7560 Lindbergh Drive Gaithersburg, Maryland 20879 Gaithersburg, Maryland 20879Gaithersburg, Maryland 20879 Gaithersburg, Maryland 20879 Testing Certificate AT-1448 Cooper Power Systems RFN420CL(1W) MODULE FCC Certification Test Report December, 2012 WLL Report #12764 Rev.1-01 - ii - © 2013 Washington Laboratories, Ltd. FCC & Industry Canada Certification Test Report for the Cooper Power Systems RFN420CL(1W) MODULE FCC ID: P9X-420CL1W IC: 6766A-420CL1W December 12, 2012 Re-issued January 3, 2013 WLL JOB# 12764 Rev.1 Prepared by: James Ritter EMC Compliance Engineer Reviewed by: Steven D. Koster Vice President Cooper Power Systems RFN420CL(1W) MODULE FCC Certification Test Report December, 2012 WLL Report #12764 Rev.1-01 - iii - © 2013 Washington Laboratories, Ltd. Abstract This report has been prepared on behalf of Cooper Power Systems to support the attached Application for Equipment Authorization. The test report and application are submitted for a Frequency Hopping Spread Spectrum Transmitter under Part 15.247 (10/2010) of the FCC Rules and Regulations and Spectrum Management and Telecommunications Policy RSS-210 issue 8 of Industry Canada. This Certification Test Report documents the test configuration and test results for the Cooper Power Systems RFN420CL(1W) Module. Testing was performed on an Open Area Test Site (OATS) of Washington Laboratories, Ltd, 7560 Lindbergh Drive, Gaithersburg, MD 20879. Site description and site attenuation data have been placed on file with the FCC's Sampling and Measurements Branch at the FCC laboratory in Columbia, MD. The Industry Canada OATS numbers are 3035A-1 and 3035A-2 for Washington Laboratories, Ltd. Site 1 and Site 2, respectively. Washington Laboratories, Ltd. has been accepted by the FCC and approved by ACLASS under Certificate AT-1448 as an independent FCC test laboratory. The Cooper Power Systems RFN420CL(1W) Module complies with the limits for a Frequency Hopping Spread Spectrum Transmitter device under FCC Part 15.247 and Industry Canada RSS- 210. Revision History Description of Change Date Rev 0 Initial Release December 12 , 2012 Rev 1 On page 60 section 5.6.1 a line was added stating that the hopping mode was disabled. January 2, 2013 Cooper Power Systems RFN420CL(1W) MODULE FCC Certification Test Report December, 2012 WLL Report #12764 Rev.1-01 - iv - © 2013 Washington Laboratories, Ltd. Table of Contents Abstract ........................................................................................................................................... ii 1 Introduction ..........................................................................................................................1 1.1 Compliance Statement .................................................................................................... 1 1.2 Test Scope ....................................................................................................................... 1 1.3 Contract Information ....................................................................................................... 1 1.4 Test Dates........................................................................................................................ 1 1.5 Test and Support Personnel ............................................................................................ 1 1.6 Abbreviations .................................................................................................................. 2 2 Equipment Under Test .........................................................................................................3 2.1 EUT Identification & Description .................................................................................. 3 2.2 Test Configuration .......................................................................................................... 3 2.3 Testing Algorithm ........................................................................................................... 3 2.4 Test Location .................................................................................................................. 4 2.5 Measurements ................................................................................................................. 4 2.5.1 References ................................................................................................................... 4 2.6 Measurement Uncertainty ............................................................................................... 4 3 Test Equipment ....................................................................................................................5 4 Test Summary ......................................................................................................................8 5 Test Results ..........................................................................................................................9 5.1 Duty Cycle Correction and Time of Occupancy ............................................................. 9 5.2 RF Power Output: (FCC Part §2.1046)......................................................................... 13 5.3 Occupied Bandwidth: (FCC Part §2.1049) ................................................................... 20 5.4 Channel Spacing and Number of Hop Channels (FCC Part §15247(a)(1) ................... 24 5.5 Conducted …

Text truncated - open the document above for the full version.

Test Setup Photos

Test Setup Photos ©2008 Washington Laboratories, Ltd Test Setup Photos ©2008 Washington Laboratories, Ltd Test Setup Photos ©2008 Washington Laboratories, Ltd Test Setup Photos ©2008 Washington Laboratories, Ltd Test Setup Photos ©2008 Washington Laboratories, Ltd Test Setup Photos ©2008 Washington Laboratories, Ltd Test Setup Photos ©2008 Washington Laboratories, Ltd Test Setup Photos ©2008 Washington Laboratories, Ltd Test Setup Photos ©2008 Washington Laboratories, Ltd Test Setup Photos ©2008 Washington Laboratories, Ltd

Contact Information

Applicant

Steven Seymour(Certification Engineer)
[email protected]240-454-9845Fax: 301-515-4965

Technical Contact

Washington Laboratories Ltd.Steven D. Koster
[email protected]301-216-1500

7560 Lindbergh Drive · Gaithersburg, Maryland · United States

Test Firm

Washington Laboratories, Ltd.Steve Koster
[email protected]301-216-1500Fax: 301-216-1590

Technical Specifications

#Rule PartsFrequency RangePower Output
115C902.75 MHz - 927.25 MHz927.00 mW
Modular Type
Single Modular Approval
Confidentiality
Long Term
Grant Notes
Modular Approval. Output Power listed is Conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures. Installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Eaton's Cooper Power Systems

RFN-410CL - FCC ID P9X-410CL - Eaton's Cooper Power Systems
P9X-410CL

RFN-410CL

Jul 16, 2013

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
RFN-430SL - FCC ID P9X-430SL - Eaton's Cooper Power Systems
P9X-430SL

RFN-430SL

Jun 18, 2013

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
RFN 420CL(1W, NZ) Module - FCC ID P9X-420CL1WNZ - Eaton's Cooper Power Systems
P9X-420CL1WNZ

RFN 420CL(1W, NZ) Module

Jan 09, 2013

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
RFN 430EL-A3 (1W) - FCC ID P9X-430ELA31W - Eaton's Cooper Power Systems
P9X-430ELA31W

RFN 430EL-A3 (1W)

Nov 25, 2012

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
RFN SelectComm-MRB Module - FCC ID P9X-RFNSCOMMMRB - Eaton's Cooper Power Systems
P9X-RFNSCOMMMRB

RFN SelectComm-MRB Module

Apr 17, 2012

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter