FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Ericsson Mobile Communications AB/
  3. PBY1130201

PBY1130201Licensed Portable

Ericsson Mobile Communications AB
Licensed Portable - FCC ID PBY1130201 - Ericsson Mobile Communications AB
Click to zoom

Application Details

Equipment Class
PCE - PCS Licensed Transmitter held to ear
Date of Grant
Jul 10, 2001
Application Purpose
Original Equipment
Date of Application
Jun 10, 2001
Equipment Note
Licensed Portable
Frequency Range
1850.20000000 - 1909.80000000
Company
Ericsson Mobile Communications AB
Country
Sweden

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

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¶WWKHSKRQHZRUNWKHZD\,ZDQW"$GGLWLRQDOLQIRUPDWLRQ 6DIHDQGHIILFLHQWXVHZDUUDQW\GHFODUDWLRQRIFRQIRUPLW\,FRQV :KDWGRWKHLFRQVPHDQ",QGH[  T68.book Page 1 Friday, May 18, 2001 12:12 PM (ULFVVRQ7P)LUVWHGLWLRQ 2FWREHU7KLVPDQXDOLVSXEOLVKHGE\(ULFVVRQ0RELOH&RPPXQLFDWLRQV$% ZLWKRXWDQ\ZDUUDQW\,PSURYHPHQWVDQGFKDQJHVWRWKLVPDQXDOQHFHVVLWDWHGE\W\SRJUDSKLFDOHUURUV LQDFFXUDFLHVRIFXUUHQWLQIRUPDWLRQ RULPSURYHPHQWVWRSURJUDPVDQGRUHTXLSPHQW PD\EHPDGHE\(ULFVVRQ0RELOH&RPPXQLFDWLRQV$%DWDQ\WLPHDQGZLWKRXWQRWLFH6XFKFKDQJHVZLOO KRZHYHU EHLQFRUSRUDWHGLQWRQHZHGLWLRQVRIWKLVPDQXDO$OOULJKWVUHVHUYHG‹(ULFVVRQ 0RELOH &RPPXQLFDWLRQV $% 3XEOLFDWLRQQXPEHU(1/=75$,1129$75213$7(1763OHDVHQRWH6RPHRIWKHVHUYLFHVLQWKLVPDQXDODUHQRWVXSSRUWHGE\DOOQHWZRUNV 7KLVDOVRDSSOLHVWRWKH *60,QWHUQDWLRQDO(PHUJHQF\1XPEHU  3OHDVHFRQWDFW\RXUQHWZRUNRSHUDWRURUVHUYLFHSURYLGHULI\RXDUHLQGRXEWZKHWKHU\RXFDQXVHDSDUWLFXODUVHUYLFHRUQRW3OHDVHUHDGWKH *XLGHOLQHVIRUVDIHDQGHIILFLHQW XVH DQGWKH /LPLWHGZDUUDQW\ FKDSWHUVEHIRUH\RX XVH\RXUPRELOHSKRQH7KH %/8(7227+ WUDGHPDUNVDUHRZQHGE\WKHLU SURSULHWRUDQGXVHGE\(ULFVVRQXQGHUOLFHQVH7Œ7H[W,QSXWLVDUHJLVWHUHGWUDGHPDUNRI7HJLF&RPPXQLFDWLRQV7Œ7H[W,QSXWLVOLFHQVHGXQGHURQHRUPRUHRIWKHIROORZLQJ863DW1RV            DQG  &DQDGLDQ3DW1R   8QLWHG.LQJGRP3DW1R%+RQJ.RQJ6WDQGDUG3DW1R+.5HSXEOLFRI6LQJDSRUH3DW1R(XUR3DW1R '('. ), )5 ,7 1/ 37 (6 6( *%DQGDGGLWLRQDOSDWHQWVDUHSHQGLQJZRUOGZLGH T68.book Page 2 Friday, May 18, 2001 12:12 PM *HWWLQJ VWDUWHG  *HWWLQJ VWDUWHG$ERXWWKLVXVHU¶VJXLGH)RUHDVHRIUHIHUHQFH WKH³*HWWLQJWRNQRZ\RXUSKRQH ́FKDSWHUJLYHVDTXLFNRYHUYLHZRIWKHPDLQIXQFWLRQVRIWKHSKRQH VKRUWFXWVDQGJHQHUDOLQIRUPDWLRQ$YDLODEOHVHUYLFHV6RPHVHUYLFHVDQGIXQFWLRQVGHVFULEHGLQWKLVXVHU¶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‡ LQVHUWWKH6,0FDUG‡ DWWDFKDQGFKDUJHWKHEDWWHU\6HH³6,0FDUGDQG EDWWHU\LQIRUPDWLRQ ́RQSDJH 1RWH $OZD\VWXUQRIIWKHSKRQHDQGGHWDFKWKH FKDUJHUEHIRUH\RXLQVHUWRUUHPRYHD6,0FDUG T68.book Page 3 Friday, May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book Page 4 Friday, May 18, 2001 12:12 PM *HWWLQJ VWDUWHG  0DNLQJDQGUHFHLYLQJFDOOV ‡ 3UHVVDQGKROG XQWLO\RXKHDUDWRQH‡ (QWHU\RXU3,1(3HUVRQDO,GHQWLW\1XPEHU) LI\RX KDYHRQHIRU\RXU6,0FDUG<RXU3,1LVSURYLGHGE\\RXUQHWZRUNRSHUDWRU,I\RXPDNHDPLVWDNHZKLOHHQWHULQJ\RXU3,1 GHOHWHWKHZURQJQXPEHUE\SUHVVLQJ ,I\RXHQWHUWKHZURQJ3,1WKUHHWLPHVLQDURZWKH6,0FDUGLVEORFNHGDQGWKHPHVVDJH3,1EORFNHGDSSHDUV7RXQEORFNLW\RXQHHGWRHQWHU\RXU38.$3HUVRQDO8QEORFNLQJ.H\%<RXU38.LVSURYLGHGE\ \RXUQHWZRUNRSHUDWRU ‡ (QWHUWKHDUHDFRGHDQGSKRQHQXPEHU DQGSUHVV  WRPDNHWKHFDOO  ‡ 3UHVV WRHQGWKHFDOO‡ :KHQWKHSKRQHULQJV SUHVV WRDQVZHUWKHFDOO 2QRII 0\1HWZRUN  T68.book Page 5 Friday, May 18, 2001 12:12 PM  *HWWLQJ WR NQRZ \RXU SKRQH *HWWLQJ WR NQRZ \RXU SKRQH.H\IXQFWLRQV 9ROXPHNH\ ,QFUHDVHRUGHFUHDVHWKHYROXPHRIWKHHDUSLHFHRUKDQGVIUHHORXGVSHDNHUGXULQJDFDOO6FUROOWKURXJKPHQXV OLVWVDQGWH[W(QWHUWKH6WDWXVPHQX6OLGHXSRUGRZQWZLFHWRUHMHFWDQLQFRPLQJFDOO0DNHDQGDQVZHUFDOOV6HOHFWDPHQX VXEPHQXRUDQRSWLRQ3UHVVIRURSWLRQV ±  (QWHUWKHGLJLWV±DQG OHWWHUV3UHVVDQGKROG WRHQWHUWKHLQWHUQDWLRQDOSUHIL[:0RYHWKURXJKPHQXVXVLQJVKRUWFXWV(QWHU;6KLIWEHWZHHQORZHUDQGXSSHUFDVH 3UHVVWKHMR\VWLFNXS GRZQ OHIWRUULJKWWRPRYHWKURXJKWKHPHQXV OLVWVDQGWH[WV3UHVVWKHMR\VWLFNDVDQDOWHUQDWLYHWR 3UHVVDQGKROGWRWXUQWKHSKRQHRQRURIIRUWRJREDFNWRVWDQGE\PRGH3UHVVWRHQGRUUHMHFWDFDOO JREDFNRQHOHYHOLQWKHPHQXVRUOHDYHDQRSWLRQXQFKDQJHG (FOHDU) 'HOHWHQXPEHUVDQGOHWWHUVIURPWKHGLV…

Text truncated - open the document above for the full version.

External Photos

CETECOM ICT Services GmbH Test report nr.:2-2519-B/01Issue date:28.11.2000Page 50 (55) Photographs of the equipment Photograph no.: 2 CETECOM ICT Services GmbH Test report nr.:2-2519-B/01Issue date:28.11.2000Page 51 (55) Photographs of the equipment Photograph no.: 3

ID Label/Location Info

Application PBY 1130201 CETECOM GmbH; Im Teelbruch 122, 45219 Essen; Germany Dipl.-Ing. Karin Silberhorn [email protected] Exhibit 1: ID Label / Location Info

RF Exposure Info

Confidential REPORT 1 (15) Prepared (also subject responsible if other)No. LD/ECS/GUF/KG Ramadan Plicanic GTX/FG 01:030 ApprovedCheckedDateRevFile GUF/KG Ramadan PlicanicECSRAPL2001-04-30A H:\RR\SAR_FCC Report\T68m.doc EN SAR Test Report: T68m Date of test:April 23 and 24, 2001 Laboratory: Electromagnetic Near Field and Radio Frequency Dosimetry Laboratory Ericsson Mobile Communications AB Nya Vattentornet, SE-221 83 LUND, Sweden Test Responsible: Ramadan Plicanic, M.Sc.EE Senior Staff Engineer, Terminal Antennas [email protected] +46 46 19 38 62 Statement of Compliance Ericsson Mobile Communications AB declares under its sole responsibility that the that the product Ericsson Type 1130201-BV (T68m) to which this declaration relates, is in conformity with the appropriate RF exposure standards, recommendations and guidelines. It also declares that the product was tested in accordance with the appropriate measurement standards, guidelines and recommended practices. Any deviations from these standards, guidelines and recommended practices are noted below: (none) © Ericsson Mobile Communications AB, 2001 This test report shall not be reproduced except in full, without written approval of the laboratory. The results and statements contained herein relate only to the items tested. The names of individuals involved may be mentioned only in connection with the statements or results from this report. Ericsson encourages all feedback, both positive and negative, on this test report. Confidential REPORT 2 (15) Prepared (also subject responsible if other)No. LD/ECS/GUF/KG Ramadan Plicanic GTX/FG 01:030 ApprovedCheckedDateRevFile GUF/KG Ramadan PlicanicECSRAPL2001-04-30A H:\RR\SAR_FCC Report\T68m.doc EN Table of Contents 1. Introduction3 2. Device Under Test3 2.1Antenna description3 2.2Device description3 3. Test equipment3 3.1 Dosimetric system3 3.2Additional equipment4 4. Electrical parameters of the tissue simulating liquid4 5. System accuracy verification4 6. Test results5 References6 Appendix 1: SAR distribution comparison for system accuracy verification7 Appendix 2: SAR distribution plots9 Appendix 3: Photographs of the device under test11 Appendix 4: Position of device on Generic Twin Phantom13 Appendix 5: Probe calibration parameters for ET3DV5 SN:110115 Confidential REPORT 3 (15) Prepared (also subject responsible if other)No. LD/ECS/GUF/KG Ramadan Plicanic GTX/FG 01:030 ApprovedCheckedDateRevFile GUF/KG Ramadan PlicanicECSRAPL2001-04-30A H:\RR\SAR_FCC Report\T68m.doc EN 1. Introduction In this test report, compliance of the Ericsson T68m portable telephone with RF safety guidelines is demonstrated (applicable RF safety guidelines are given in [1]). The device was tested in accordance with the latest available test guidelines [1]. Detailed procedures of the test are described in the Ericsson SAR Measurement Specification [2]. 2. Device Under Test 2.1 Antenna description Type Built in Location Back on the top length- Dimensions width at base- Configuration PIFA 2.2 Device description Device model T68m Serial numberA5103K2MYJ Mode 1900 TDMA Multiple Access Scheme TDMA Maximum Output Power Setting 1 29.0 dBm Factory Tolerance in Power Setting ± 0.5dB Maximum Peak Output Power 2 29.5 dBm Duty Cycle1 / 8 Transmitting Frequency Range1850 – 1910 MHz Prototype or Production UnitPrototype 3. Test equipment 3.1 Dosimetric system SAR measurements were made using the DASY3 professional system (software version 3.1c), manufactured by Schmid & Partner Engineering AG and installed Juny, 1996. The total SAR assessment uncertainty (K = 1) of the system is ±16% and includes a +15% offset (overestimation). The extended uncertainty (K = 2) is ±32% with a +15% offset. This results in a total uncertainty range of –1% to +31% for K = 1, or –17% to +47% for K = 2. The equipment list is given below. DescriptionSerial NumberDue Date DASY3 DAE V2 2155/01 E-field probe ETDV411015/01 Dipole Validation Kit, D1800V22285/02 1 This is the conducted power measured at the antenna port when the device is set to its highest power setting. It is measured at the middle of the transmit frequency band. Note that the output power may be different at other frequencies. 2 This equals the maximum output power setting plus the factory tolerance. Confidential REPORT 4 (15) Prepared (also subject responsible if other)No. LD/ECS/GUF/KG Ramadan Plicanic GTX/FG 01:030 ApprovedCheckedDateRevFile GUF/KG Ramadan PlicanicECSRAPL2001-04-30A H:\RR\SAR_FCC Report\T68m.doc EN 3.2 Additional equipment DescriptionSerial NumberDue Date Signal Generator ESG-D4000A INV 5629354/02 Dielectric probe kit HP 85070B INV 4430297/02 Network analyzer HP 8753CINV 4216706/01 Power meter R&S NRVDINV 48392012/01 Power sensor R&S NRV-Z5INV 233412/01 Wavetek 4106GPPINV 4629917/01 4. Electrical parameters of the tissue simulating liquid Prior to conducting SAR measurements, the relative permittivity, ε r , and the conductivity, σ, of the tissue simulating liquids were measured with the dielectric probe kit. These values are shown in the table below. The mass density, ρ, entered into the DASY3 program is also given. Recommended limits for maximum permittivity, minimum conductivity and maximum mass density are also shown [3]. It is seen that the measured parameters result in an overestimation of SAR compared to the recommended values. Dielectric Parameters f (MHz) Tissue type Limits / Measured ε r σ (S/m)ρ (g/cm 3 ) Measured, 04/23/01 38.1 1.681.00Head Recommended Limits[3]43.51.151.03 Measured, 04/23/0138.11.681.00 1800 Muscle Recommended Limits [3]54.41.391.04 5. System accuracy verification A system accuracy verification of the DASY3 was performed using the dipole validation kit listed in Section 3.1. The system verification test was conducted on the same day as the measurement of the DUT. The obtained results are displayed in the table below. It is seen that the system is operating within its specification, as the results are within ±5% of the reference…

Text truncated - open the document above for the full version.

Test Report

CETECOM ICT Services GmbH Radio Satelite Communication Untertürkheimer Straße 6-10 . D-66117 SaarbrückenTelefon: +49 (0)681 598-9100Telefax: -9075 RSC11issue test report consist of 55 PagesPage 1 (55) Test report no.: 2-2519-B/01 FCC Part 24 1130201-BV FCC ID : PBY1130201-BV Accredited Testing Laboratory DAR-Registration number: TTI-P-G 166/98-20 CETECOM ICT Services GmbH Test report nr.:2-2519-B/01Issue date:25.05.2001Page 2 (55) Table of Contents 1 General information 1.1 Notes 1.2 Testing laboratory 1.3 Details of applicant 1.4 Application details 1.5 Test item 1.6 Test standards 2 Technical test 2.1 Summary of test results 2.2 Test report 1 General information 1.1 Notes The test results of this test report relate exclusively to the test item specified in 1.5. The CETECOM ICT Services GmbH does not assume responsibility for any conclusions and generalisations drawn from the test results with regard to other specimens or samples of the type of the equipment represented by the test item. The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report requires the prior written approval of the CETECOM ICT Services GmbH. 1.2Testing laboratory CETECOM ICT Services GmbH Untertürkheimer Straße 6 - 10 66117 Saarbrücken Germany Telefone: + 49 681 598 - 9100 Telefax : + 49 681 598 - 9075 E-mail: [email protected] Internet: www.cetecom.de Accredited testing laboratory DAR-registration number : TTI-P-G 166/98-00 CETECOM ICT Services GmbH Test report nr.:2-2519-B/01Issue date:25.05.2001Page 3 (55) 1.3Details of applicant Name :Ericsson Mobile Communications AB Street :Nya Vattentornet City :S-22183 Lund Country :Sweden Telephone:+46-46-19 3000 Telefax :+46-46-19 3295 Contact :Mr. Bo Johansson Telephone:+46-46-19 3000 1.4Application details Date of receipt of application : 14.05.01 Date of receipt of test item : 17.05.01 Date of test : 17.-06.06.01 1.5Test item Type of equipment :GSM 900/1800/1900 Mobile Phone with integrated Bluetooth Module Type designation:113020101-BV Manufacturer:Applicant Street: City: Country: Serial number:243 099999-00-123456-0-00 Additional informations:: Frequency:1850 – 1910 MHz Type of modulation:300KF2D Number of channels :300 Antenna:Integral antenna and socket Power supply:3.6 VDC accu Li-Polymer Output power:28.8 dBm Peak / ERP : 27.3 dBm (Burst); EIRP: 29.3 dBm (Burst) Type of equipment:Temperature range : -30°C - +60°C FCC – ID:PBY1130201 Hardware:PA1 Software:R1A023prgCXC125265 / R1A023 prgCXC125326_TAE 1.6Test standards: FCC Part 24 CETECOM ICT Services GmbH Test report nr.:2-2519-B/01Issue date:25.05.2001Page 4 (55) 2 Technical test 2.1Summary of test results No deviations from the technical specification(s) were ascertained in the course of the tests performed. Technical responsibility for area of testing : 08.06.01RSC 8411Berg M. DateSectionNameSignature Technical responsibility for area of testing : 08.06.01RSC8412Hausknecht DateSectionNameSignature CETECOM ICT Services GmbH Test report nr.:2-2519-B/01Issue date:25.05.2001Page 5 (55) 2.2Testreport TEST REPORT Testreport no. : 2-2519-B/01 CETECOM ICT Services GmbH Test report nr.:2-2519-B/01Issue date:25.05.2001Page 6 (55) TEST REPORT REFERENCE LIST OF MEASUREMENTS PARAMETER TO BE MEASURED ParagraphPAGE POWER OUTPUT SUBCLAUSE § 24.2327 FREQUENCY STABILITY SUBCLAUSE § 24.2359 AFC FREQ ERROR vs. VOLTAGE10 AFC FREQ ERROR vs. TEMPERATURE10 EMISSIONS LIMITS §24.23811 CONDUCTED SPURIOUS EMISSIONS25 OCCUPIED BANDWIDTH §2.98936 CONDUCTED EMISSIONS § 15.107/20743 TEST EQUIPMENT AND ANCILLARIES USED FOR TESTS44 TEST SITE46 PHOTOGRAPHS OF THE EQUIPMENT49 CETECOM ICT Services GmbH Test report nr.:2-2519-B/01Issue date:25.05.2001Page 7 (55) REFERENCE NUMBER(S) OF TEST EQUIPMENT USED (for reference numbers see test equipment listing) 64 POWER OUTPUT SUBCLAUSE § 24.232 Summery: This paragraph contains both average , peak output powers and EIRP measurements for the mobile station. In all cases, the peak output power is wthin the required mask (this mask is specified in the JTC standarts, TIA PN3389 Vol. 1 Chap 7, and is no FCC requirement). Method of Measurements: The mobile was set up for the max. output power with pseudo random data modulation. The power was measured with R&S Spectrum Analyzer FSIQ 26 ( peak and average) This measurements were done at 3 frequencies, 1850,2 MHz, 1880,0 MHz and 1909,8 MHz (bottom, middle and top of operational frequency range) Limits: Power StepNominal Peak Output Power (dBm) Tolerance (dB) 0+30± 2 Power Measurements: Conducted: Frequency (MHz) Power Step Peak Output Power (dBm) Average Output Power (dBm) 1850.2028.819.8 1880.0028.319.3 1909.8028.719.7 Measurement uncertainty±0.5 dB CETECOM ICT Services GmbH Test report nr.:2-2519-B/01Issue date:25.05.2001Page 8 (55) REFERENCE NUMBER(S) OF TEST EQUIPMENT USED (for reference numbers see test equipment listing) 17 - 24 EIRP Measurements Description: This is the test for the maximum radiated power from the phone. Rule Part 24.232(b) specifies that "Mobile/portable stations are limited to 2 watts e.i.r.p. peak power..." and 24.232(c) specifies that "Peak transmit power must be measured over any interval of continuous transmission using instrumentation calibrated in terms of an rms-equivalent voltage." Method of Measurement: 1. In an anechoic antenna test chamber, a half-wave dipole antenna for the frequency band of interest is placed at the reference center of the chamber. An RF Signal source for the frequency band of interest is connected to the dipole with a cable that has been constructed to not interfere with the radiation pattern of the antenna. A known (measured) power (Pin) is applied to the input of the dipole, and the power received (Pr) at the chamber's probe antenna is recorded. 2. A "reference path loss" is established as Pin + 2.1 - Pr. 3. The EUT is substituted for the dipole at the reference center of the chamber. The EUT is put into CW test mode and a scan is perform…

Text truncated - open the document above for the full version.

Test Setup Photos

CETECOM ICT Services GmbH Test report nr.:2-2519-B/01Issue date:28.11.2000Page 46 (55) Test site RADIATED EMISSIONS CETECOM ICT Services GmbH Test report nr.:2-2519-B/01Issue date:28.11.2000Page 47 (55) Test site CONDUCTED EMISSIONS CETECOM ICT Services GmbH Test report nr.:2-2519-B/01Issue date:28.11.2000Page 48 (55)

Contact Information

Applicant

Mats Hansson(Senior Staff Engineer)
[email protected]+46 46 193 000Fax: +46 46 193 295

Technical Contact

Ericsson Mobile Communications ABH�kan Sj�berg
[email protected]+ 46 46 193 000

Im Teelbruch 122 · Lund · Germany

Non-Technical Contact

Ericsson Mobile Communications ABMats Hansson
[email protected]+ 46 46 193 000

Test Firm

CETECOM GmbHWolfgang Richter
[email protected]0049-2054-9519-281Fax: 0049-2054-9519-964

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
124E1.85 GHz - 1.91 GHz871.00 mW291KDXW1.0000000000 ppm
Confidentiality
Long Term

Other Applications from Ericsson Mobile Communications AB

PCMCIA card for Laptop Computer - FCC ID PBY6130201-BV - Ericsson Mobile Communications AB
PBY6130201-BV

PCMCIA card for Laptop Computer

Nov 25, 2001

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
Licensed Portable - FCC ID PBY1130401 - Ericsson Mobile Communications AB
PBY1130401

Licensed Portable

Nov 12, 2001

Equipment Class

PCE - PCS Licensed Transmitter held to ear
Bluetooth Headset - FCC ID PBY8505002 - Ericsson Mobile Communications AB
PBY8505002

Bluetooth Headset

Sep 27, 2001

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Licensed Portable - FCC ID PBY1130102 - Ericsson Mobile Communications AB
PBY1130102

Licensed Portable

May 10, 2001

Equipment Class

PCE - PCS Licensed Transmitter held to ear
Bluetooth Phone Plug - FCC ID PBY8404003-BV - Ericsson Mobile Communications AB
PBY8404003-BV

Bluetooth Phone Plug

Mar 22, 2001

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter