
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
MODEL: IBM-3920 2.4GHz DSST CALL WAITING CALLER ID WIRELESS TELEPHONE IMPORTANT:To receive Caller ID information on incoming telephone calls, you must subscribe to the Caller ID service provided by your local telephone company; there is a fee for this service and it may not be available in all areas. ยฎ 600-0630401-A INSTALLATION AND OPERATING GUIDE Important Safety Instructions .............2 FCC Regulations...............................3-4 Battery Cautionary Instructions .........5 IBM-3920 Parts Checklist .....................6 Location of Controls and Features...........................................7-11 Handset ...........................................7-8 Base ..............................................9-10 LCD Display ......................................11 Choosing a Location .........................12 Battery Installation............................13 Battery Duration ...............................13 When the Battery Needs Charging ...13 When to Purchase a New Battery Pack .....................................13 Connecting the Phone......................14 Connect the Base .............................14 Connect the Charging Cradle ...........14 Initialize the Handset to the Base .....14 Wall Mounting .....................................15 Headset and Data Jack ......................16 The Data Jack ...................................16 The Headset Jack.............................16 Belt-Clip ............................................16 Settings ..........................................17-27 Handset Settings ..............................17 Setting the Username .......................18 Changing the Ringer Level ...............18 Changing the Ring Tone ...................19 Setting the Time and Date ...........19-20 Setting the Area Code ......................21 Turning Key Beeps On/Off ................22 Changing the Flash Time .................23 Changing the Pause Time ................24 Changing the Tone/Pulse Mode .......25 Setting the Line in Use Check ............26 Resetting to Factory Defaults ...........27 Basic Displays....................................28 Basic Operation.............................29-30 Making Calls .....................................29 Receiving Calls ................................29 Putting a Call on Hold .......................30 Using the Monitor ............................30 AdditionalOptions ...........................30 Speed Dialing...............................31-34 Storing Phone Numbers ...............31-32 Letter Table ........................................32 Making Calls with Speed Dialing .......33 Deleting a Stored Number ................33 Editing a Stored Number ...................34 Name Matching .................................34 Redial.................................................35 Redial the Last Number .....................35 Redial Last 10 Numbers ....................35 Storing Redial Numbers ....................35 Caller ID.........................................36-40 When You Receive a Call .................36 Viewing the Caller ID List ..................36 Caller ID Displays ..............................37 Caller ID with Call Waiting Service ....38 Storing Caller ID Records .................38 Deleting Caller ID Records ...............39 Returning Caller ID Calls ...................40 Message Waiting ................................41 New Call Light ...................................41 Other Features ...................................42 Using the Handset Finder (PAGE) ....42 Out-of-Range Warning .....................42 Care and Maintenance.......................43 Glossary ..............................................44 Troubleshooting............................45-46 Warranty.........................................47-48 Wall Mount Templates ........................49 Replacement Battery Order Form....50 This symbol is to alert you to important operating or servicing instructions that may appear in the user's manual. Always follow basic safety precautions when using this product to reduce the risk of injury, fire or electrical shock. When using this product, basic safety precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following: 1.Read and understand all instructions. 2.Follow all warnings and instructions marked on the product. 3.Use only with class 2 power source DC 9V 300mA (base) and class 2 power source DC 9V 100mA (charging cradle). 4.Unplug this product from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning. 5.Do not use this product near water; for example, near a bathtub, wash bowl, kitchen sink or laundry tub, in a wet basement or near a swimming pool. 6.Do not place this product on an unstable cart, stand or table. The product may fall, causing serious damage to the product. 7.Slots and openings in the cabinet back or bottom are provided for ventilation. To protect it from overheating, these openings must not be blocked or covered. The openings should never be blocked by placing the product on the bed, sofa, rug, or other similar surface. This product should never be placed near or over a radiator or heat register. This product should not be placed in an enclosed environment unless proper ventilation is provided. 8.Do not allow anything to rest on the power cord. Do not locate this product where the cord will be abused by animals or persons walking on it. 9.Do not overload wall outlets and extension cords as this can result in risk of fire or electrical shock. 10. Never push objects of any kind into this product through cabinet slots as they may touch dangerous voltage points or short out parts that could result in a risk of fire or electrical shock. Never spill liquid of any kind on the product. 11. To reduce the risk of electrical shock, do not disassemble this product. Instead take it to a qualified service person when service or repair work is requโฆ
Text truncated - open the document above for the full version.
Page 1 of 1 1/22/02file://T:\I\ISV\1286BK1\intphot\1286b-6D-int%20pho%20comp%20base.JPG Page 1 of 1 1/22/02file://T:\I\ISV\1286BK1\intphot\1286b-6c-int%20pho%20comp%20hset.JPG Page 1 of 1 1/22/02file://T:\I\ISV\1286BK1\intphot\6a.JPG Page 1 of 1 1/22/02file://T:\I\ISV\1286BK1\intphot\1286B-6A-int%20pho%20comp%20base.JPG Page 1 of 1 1/22/02file://T:\I\ISV\1286BK1\intphot\1286B-6b-int%20pho%20copp%20base.JPG
TABLE OF CONTENTS LIST APPLICANT: ISV CO., LTD. FCC ID: PE3IBM-3920 TEST REPORT: PAGE 1..........SECURITY CODING INFORMATION PAGE 2-3........TEST PROCEDURE AND TEST EQUIPMENT LIST PAGE 4-6........POWER LINE CONDUCTED INTERFERENCE PAGE 7-13.......OCCUPIED BANDWIDTH AND PEAK POWER OUTPUT PAGE 14.........RADIATED SPURIOUS EMISSIONS HANDSET PAGE 15.........RADIATED SPURIOUS EMISSIONS BASE PAGE 16-18......RADIATED SPURIOUS EMMISSIONS INTO ADJACENT RESTRICTED BAND PAGE 19-25.......SPECTRAL POWER DENSITY AND PROCESSING GAIN EXHIBITS: EXHIBIT 1........FCC ID LABEL SAMPLES EXHIBIT 2A.......SKETCH OF LABEL LOCATION - HANDSET EXHIBIT 2B.......SKETCH OF LABEL LOCATION BASE EXHIBIT 3A-C.....BLOCK DIAGRAMS EXHIBIT 4A-E.....SCHEMATICS EXHIBIT 5A.......EXTERNAL PHOTO โ FRONT VIEW โ BASE EXHIBIT 5B.......EXTERNAL PHOTO โ BOTTOM VIEW โ BASE EXHIBIT 5C.......EXTERNAL PHOTO โ FRONT VIEW โ HANDSET EXHIBIT 5D.......EXTERNAL PHOTO โ REAR VIEW โ HANDSET EXHIBIT 6A.......INTERNAL COMPONENT SIDE PHOTO - BASE EXHIBIT 6B.......INTERNAL SOLDER SIDE PHOTO - BASE EXHIBIT 6C.......INTERNAL COMPONENT SIDE PHOTO โ HANDSET EXHIBIT 6D.......INTERNAL SOLDER SIDE PHOTO - HANDSET EXHIBIT 7........INSTRUCTION MANUAL EXHIBIT 8........CIRCUIT DESCRIPTION EXHIBIT 9........RADIATED TEST SET UP PHOTO - HANDSET EXHIBIT 10.......RADIATED TEST SET UP PHOTO - BASE EXHIBIT 11.......POWERLINE CONDUCTED TEST SET UP PHOTO โ BASE EXHIBIT 12A-C....PROCESSING GAIN TEST DATA EXHIBIT 13A-B....SPECIFICATION SHEET APPLICANT: ISV CO., LTD. FCCID: PE3IBM-3920 DATE: JANUARY 3, 2002 REPORT #: I\ISV\1286BK1\1286BK1RPT.DOC APPLICANT: ISV CO., LTD. FCC ID: PE3IBM-3920 15.214(d) THIS DEVICE COMPLIES WITH THE SECURITY CODE REQUIREMENTS OF 15.214(d)(1)(2) AND (3) BY MEANS OF THE FOLLOWING: THIS DEVICE HAS 65536 POSSIBLE SECURITY CODES. ONE SECURITY CODE OUT OF 65536 IS PRE-PROGRAMMED WHEN MANUFACTURED AT THE FACTORY. THE CPU CONTROLS THE RF FREQUENCY CHANNEL. AND THE ASIC CONTROLS ADPCM CODEC AND AUDIO SIGNAL SWITCHING ALSO SET UP THE SPREADING CODE. BEFORE THE COMMUNICATION LINK IS ESTABLISHED, THE DEVICE SEARCHES FOR A VACANT RF CHANNEL AND THEN TRANSMITS RF SIGNAL ON THE VACANT CHANNEL. APPLICANT: ISV CO., LTD. FCCID: PE3IBM-3920 DATE: JANUARY 3, 2002 REPORT #: I\ISV\1286BK1\1286BK1RPT.DOC PAGE #: 1 APPLICANT: ISV CO., LTD. FCCID : PE3IBM-3920 TEST EQUIPMENT LIST 1._X_Spectrum Analyzer: HP 8566B-Opt 462, S/N 3138A07786, w/ preselector HP 85685A, S/N 3221A01400, Quasi-Peak Adapter HP 8565OA, S/N 3303A01690 & Preamplifier HP 8449B-OPT H02, S/N 3008A00372 Cal. 8/31/01 Due 8/31/02 2.__ Biconnical Antenna: Eaton Model 94455-1, S/N 1057, Cal. 10/1/01 Due 10/1/02 3.__ Biconnical Antenna: Electro-Metrics Model BIA-25, S/N 1171 Cal. 4/26/01 Due 4/26/03 4.__ Log-Periodic Antenna: Electro-Metrics Model EM-6950, S/N 632 Char. 10/15/01 Due 10/15/02 5.__ Log-Periodic Antenna: Electro-Metrics Model LPA-30, S/N 409 Char. 10/16/01 Due 10/16/02 6.__ Log-Periodic Antenna: Electro-Metrics Model LPA-25, S/N 1122 Char. 2/10/01 Due 3/10/02 7.__ Double-Ridged Horn Antenna: Electro-Metrics Model RGA-180, 1-18 GHz, S/N 2319 Cal. 12/19/01 Due 12/19/02 8.__ 18-26.3GHz Systron Donner Standard Gain Horn #DBE-520-20 No Cal Required 9.__ Horn 40-60GHz: ATM Part #19-443-6R No Cal Required 10.__ Line Impedance Stabilization Network: Electro-Metrics Model EM-7820, w/NEMA Adapter S/N 2682 Cal. 3/16/01 Due 3/16/02 11.__ Temperature Chamber: Tenney Engineering Model TTRC, S/N 11717-7 Char. 1/27/01 Due 1/27/02 12.__ Frequency Counter: HP Model 5385A, S/N 3242A07460 Char. 12/11/01 Due 12/11/02 13.__ Peak Power Meter: HP Model 8900C, S/N 2131A00545 Char. 1/26/01 Due 1/26/02 14._X_Open Area Test Site #1-3meters Cal. 12/22/99 15.__ Signal Generator: HP 8640B, S/N 2308A21464 Cal. 11/15/01 Due 11/15/02 16.__ Passive Loop Antenna: EMCO Model 6512, 9KHz to 30MHz, S/N 9706-1211 Char. 7/10/01 Due 7/10/02 17.__ Dipole Antenna Kit: Electro-Metrics Model TDA-30/1-4, S/N 152 Cal. 3/21/01 Due 3/21/02 18.__ AC Voltmeter: HP Model 400FL, S/N 2213A14499 Cal. 10/9/01 Due 10/09/02 19._X_Digital Multimeter: Fluke Model 77, S/N 35053830 Char. 1/11/01 Due 1/11/02 20.__ Oscilloscope: Tektronix Model 2230, S/N 300572 Char. 2/1/01 Due 2/1/02 APPLICANT: ISV CO., LTD. FCC ID : PE3IBM-3920 DATE: JANUARY 3, 2002 REPORT #: I\ISV\1286BK1\1286BK1RPT.DOC PAGE # : 2 TEST PROCEDURES GENERAL: This report shall NOT be reproduced except in full without the written approval of TIMCO ENGINEERING, INC. Shielded interface cables were used in all cases except for cables connecting to the telephone line and the power cords. A test program was run which simulated a normal data transmission on a network. POWER LINE CONDUCTED INTERFERENCE: The procedure used was ANSI STAN- DARD C63.4-1992 using a 50uH LISN. Both lines were observed. The bandwidth of the spectrum analyzer was 10kHz with an appropriate sweep speed. The ambient temperature of the UUT was 83ยฐF with a humidity of 19%. BANDWIDTH 6.0dB: The measurements were made with the spectrum analyz- er's resolution bandwidth(RBW)=100kHz and the video bandwidth(VBW) =300KHz and the span set as shown on plot. See pages 8-13. POWER OUTPUT: The RF power output was measured at the antenna feed point by removing the permanent antenna and connecting the UUT to a peak power meter, HP Model No. 8900C. ANTENNA CONDUCTED EMISSIONS: The RBW=100kHz, VBW > or = RBW and the spectrum was scanned from 30MHz to the 10th Harmonic of the fundamental. RADIATION INTERFERENCE: The test procedure used was ANSI STANDARD C63.4-1992 using a HEWLETT PACKARD spectrum analyzer with a preselector. The bandwidth(RBW) of the spectrum analyzer was 100kHz up to 1GHz and 1.0MHz above 1GHz with an appropriate sweep speed. The VBW above 1.0GHz was = 1.0MHz. The analyzer was calibrated in dB above a microvolt at the output of the antenna. The ambient temperature of the UUT was 83ยฐF with a humidity of 19%. 15.247(d) POWER SPECTRAL DENSITY. The peak within the pass band was located with a RBW set to 30Khz and a span of 5MHz, sligโฆ
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 13.00 mW |

BLUETOOTH USB DONGLE
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
2.4GHZ BT WIRELESS MOUSE
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
DIGITAL WIRELESS MICROPHONE SYSTEM
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
DIGITAL WIRELESS MICROPHONE SYSTEM
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
DIGITAL TRANSMISSION SYSTEM
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter