Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Total Biometric Solution Provider ’ Chapter 1.Don’t change the USB port after the first installation into the user PC. 2.You must connect cables while the power of PC is OFF and theeNBio Gate power is also OFF. 3. You have to install the eNBio Gate in the place without strong backlight. It can make the camera movement error. 4. Don’t disassemble eNBioGate without NITGEN’sapproval. If do, you cannot have the A/S from us. Chapter ’’ ‘‘’’ ‘‘’’‘‘’’ ‘‘’’ ‘‘’’ ‘‘’’ ‘‘’’‘‘’’ ‘‘ ’’ ““”” ‘‘ ’’ FCC NOTICE THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITION: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDERSIRED OPERATION. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communication. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures : - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit difference from that to which the receiver is connected. - Consult the dealer of an experienced radio/TV technician for help. NOTE : The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment.
Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD21046 TO WHOM IT MAY CONCERN Pursuant to Paragraphs §0.457 and 0.459 of the Commission's Rules (47 C.F.R) and Section §552(b)(4) of the Freedom of Information Act, NITGen Co., Ltd. requests confidentiality for the following products: FCC ID Number Product Product designation / Model PEBENBIOGATE Multi-Biometrics System / eNBio Gate For the product stated above, we request that the following information be held confidential: 1) Block diagram 2) Schematic diagrams 3) Bill of materials (Part List) No other items submitted as part of the equipment authorization filing process are deemed confidential. The above exhibits contain NITGen Co., Ltd. trade secrets and proprietary information that could be of benefit to our competitors regarding the design of our products. This material is not customarily available to the general public and we request that it be withheld from public inspection. Sincerely, GOHNG SANG HO / Manager [email protected] NITGen Co., Ltd. Sanhak Research Foundation B/D, 5th Fl. 1337-31, Seocho-dong, Seocho-ku Seoul, 137-070 South Korea TEL: +82-2-3415-1800, FAX: +82-2-3415-1801
SK TECH CO., LTD. Page 1 of 2 SKT SKTFCE-050921-077 FCC ID :PEBENBIOGATE External Photographs of EUT SK TECH CO., LTD. Page 2 of 2 SKT SKTFCE-050921-077 FCC ID :PEBENBIOGATE
SK TECH CO., LTD. Page 1 of 1 SKT SKTFCE-050921-077 FCC ID : PEBENBIOGATE FCC ID Sample Label & Location Information LABELLING REQUIREMENTS PER ∫∫∫∫2.928 The Label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time of purchase. NITGen Co., Ltd. Multi-Biometrics System MODEL:eNBio Gate FCC ID : PEBENBIOGATE This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause
SK TECH CO., LTD. Page 1 of 1 SKT SKTFCE-050921-077 FCC ID : PEBENBIOGATE FCC ID Label Sample NITGen Co., Ltd. Multi-Biometrics System MODEL:eNBio Gate FCC ID:PEBENBIOGATE This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause
SK TECH CO., LTD. Page 1 of 18 SKT SKTFCE-050921-077 FCC ID : PEBENBIOGATE Internal Photographs of EUT SK TECH CO., LTD. Page 2 of 18 SKT SKTFCE-050921-077 FCC ID : PEBENBIOGATE SK TECH CO., LTD. Page 3 of 18 SKT SKTFCE-050921-077 FCC ID : PEBENBIOGATE SK TECH CO., LTD. Page 4 of 18 SKT SKTFCE-050921-077 FCC ID : PEBENBIOGATE SK TECH CO., LTD. Page 5 of 18 SKT SKTFCE-050921-077 FCC ID : PEBENBIOGATE SK TECH CO., LTD. Page 6 of 18 SKT SKTFCE-050921-077 FCC ID : PEBENBIOGATE SK TECH CO., LTD. Page 7 of 18 SKT SKTFCE-050921-077 FCC ID : PEBENBIOGATE SK TECH CO., LTD. Page 8 of 18 SKT SKTFCE-050921-077 FCC ID : PEBENBIOGATE SK TECH CO., LTD. Page 9 of 18 SKT SKTFCE-050921-077 FCC ID : PEBENBIOGATE
SK TECH CO., LTD. Page 1 of 21 SKT SKTFCE-050921-077 FCC ID :PEBENBIOGATE Certificate of Compliance Test Report No.: SKTFCE-050921-077 NVLAP CODE : 200220-0 Applicant: NITGen Co., Ltd. Applicant Address: Sanhak Research Foundation B/D, 5 th Fl. 1337-31, Seocho-dong, Seocho-ku, Seoul, 137-070 South Korea Manufacturer : NITGen Co., Ltd. Manufacturer Address: Sanhak Research Foundation B/D, 5 th Fl. 1337-31, Seocho-dong, Seocho-ku, Seoul, 137-070 South Korea Product: Multi-Biometrics System FCC ID: PEBENBIOGATE Model No.: eNBio Gate Receipt No.: SKTEU05-0570 Date of receipt: Aug 29, 2005 Date of Issue: Sep 21, 2005 Testing location: SK TECH CO., LTD. 820-2, Wolmoon-Ri, Wabu-Up, Namyangju-Si, Kyunggi-Do, Korea Test Standards: ANSI C63.4 / 2003 Rule Parts: FCC part 15 Subpart B Equipment Class : Class B Digital Device Peripheral Test Result: The above mentioned product has been tested and passed. Prepared by: S.Y.Ye Tested by: H.Y.Kim/Engineer Approved by: D.H.Kang /Manager& Chief Engineer Signature Date Signature Date Signature Date Other Aspects : Abbreviations : · OK, Pass = passed · Fail = failed · N/A = not applicable ☞ •This test report is not permitted to copy partly without our permission. •This test result is dependent on only equipment to be used. •This test result is based on a single evaluation of one sample of the above mentioned. •This test report must not be used by the client to claim product endorsement by NVLAP or any agency of the U.S Government. • We certify that this test report has been based on the measurement standards that is traceable to the national or International standards. NVLAP Lab. Code: 200220-0 SK TECH CO., LTD. Page 2 of 21 SKT SKTFCE-050921-077 FCC ID :PEBENBIOGATE 》》 Contents 《《 Contents 2 List of Tables 2 List of Figures 2 1. General 3 2. Test Site 3 2.1 Location 3 2.2 List of Test and Measurement Instruments 4 2.3 Test Date 4 2.4 Test Environment 4 3. Description of the tested samples 5 3.1 Rating and Physical Characteristics 5 3.2 Submitted Documents 5 4. Measurement Conditions 6 4.1 Modes of Operation 6 4.2 List of Peripherals 6 4.3 Type of Used cables 7 4.4 Test Setup 7 4.5 Uncertainty 8 5. EMISSION Test 11 5.1 Conducted Emissions 11 5.2 Radiated Emissions 20 》List of Tables Table 1 List of test and measurement Equipment 4 Table 2 Test Data, Radiated Emissions 21 》List of Figures Figure 1 Spectral Diagram, LINE-PE(PC) 12 Figure 2 Test Data, LINE-PE(PC) 13 Figure 3 Spectral Neutral –PE(PC) 14 Figure 4 Test Data, Neutral-PE(PC) 15 Figure 5 Spectral Diagram, LINE-PE(Adaptor) 16 Figure 6 Test Data, LINE-PE(Adaptor) 17 Figure 7 Spectral Neutral –PE(Adaptor) 18 Figure 8 Test Data, Neutral-PE(Adaptor) 19 SK TECH CO., LTD. Page 3 of 21 SKT SKTFCE-050921-077 FCC ID :PEBENBIOGATE 1. General This equipment has been shown to be capable of compliance with the applicable technical standards and was tested in accordance with the measurement procedures as indicated in this report. We attest to the accuracy of data. All measurements reported herein were performed by SK Tech Co., Ltd. and were made under Chief Engineer’s supervision. We assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. 2. Test Site SK TECH Co., Ltd. 2.1 Location 820-2, Wolmoon Ri, Wabu-Up, Namyangju-Si, Kyunggi-Do, Korea The test site is in compliance with ISO/IEC 17025 for general requirements for the competence of testing and calibration laboratories. This laboratory is accredited by NVLAP for NVLAP Lab. Code : 200220-0 and DATech for DAR-Registration No.:DAT-P-076/97-01 SK TECH CO., LTD. Page 4 of 21 SKT SKTFCE-050921-077 FCC ID :PEBENBIOGATE 2.2 List of Test and Measurement Instruments Table 1 : List of Test and Measurement Equipment z Conducted Disturbance Kind of Equipment Type S/N Calibrated until EMI Receiver ESHS10 862970/019 09.2006 Artificial Mains Network ESH2-Z5 834549/011 08.2006 EMI Receiver ESHS10 835871/002 09.2006 Artificial Mains Network ESH3-Z5 836679/018 08.2006 z Radiated Disturbance Kind of Equipment Type S/N Calibrated until EMI Receiver ESVS 10 825120/013 09.2006 EMI Receiver ESVS 10 834468/008 09.2006 Spectrum Analyzer R3361A 11730187 09.2006 Amplifier 8447F 3113A05153 08.2006 Log Periodic Antenna UHALP9107 1819 12.2005 Biconical Antenna BBA9106 91031626 12.2005 Open Site Cable N/A N/A N/A Antenna Turntable Driver 5907 N/A N/A Antenna Turntable controller 5906 N/A N/A Amp & Receiver connection cable N/A N/A N/A Amp & Spectrum connection cable N/A N/A N/A 50Ω Switcher MP59B 6100214538 N/A 2.3 Test Date Date of Application : Aug. 29, 2005 Date of Test : Oct. 05, 2005 ~ Oct. 06, 2005 2.4 Test Environment See each test item’s description. SK TECH CO., LTD. Page 5 of 21 SKT SKTFCE-050921-077 FCC ID :PEBENBIOGATE 3. Description of the tested samples The EUT is a Multi’-Biometrics System. It has one infrared sensor for the location of camera where a camera is, one camera for face detection, two fingerprint sensors and one RFID reader. The two fingerprint sensors and a RFID reader are powered from the PC, the others are from the adaptor for EUT. 3.1 Rating and Physical Characteristics Section Content Size Case above images Power Adaptor Input:AC 100 V ~240 V, 50/60Hz Output: DC 12 V, 3 A Operating -20°C~60°C(With no icing or condensation) Temperature Storage -25°C~65°C Operating 25%~85% RH Humidity Storage 15%~90% RH IR Sensor Max. range 1m For the camera Min. range 40cm Weight 27Kg 3.2 Submitted Documents N/A SK TECH CO., LTD. Page 6 of 21 SKT SKTFCE-050921-077 FCC ID :PEBENBIOGATE 4. Measurement Conditions Operating voltage of the EUT is AC120V, 60Hz. 4.1 Modes of Operation The camera on the EUT was moving up and down continuously and it’s screen displayed on the PC read the RFID card DATA and finger print. 4.2 List of Peripherals Equipment Manufacturer Model Name Serial No. PC Samsung Electronics DM-P40 Z39699AXC00234E Adaptor(for EUT) SI TECH SAD06024-UV 050700000 1AA Keyboard(PS2) Jing Mold Enterpri…
Text truncated - open the document above for the full version.
SK TECH CO., LTD. Page 1 of 2 SKT SKTFCE-050921-077 FCC ID :PEBENBIGATE Test set up photos Photograph 1: Setup for Conducted Emissions SK TECH CO., LTD. Page 2 of 2 SKT SKTFCE-050921-077 FCC ID :PEBENBIGATE Photograph 2: Setup for Radiated Emissions
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | - | - |

COMMERCIAL
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
ACCESS CONTROLLER
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
ACCESS CONTROLLER
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
ACCESS CONTROLLER
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
ACCESS CONTROLLER
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter