FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Mandolyn Electronic Technology Inc./
  3. PLJWS928

PLJWS928Weather Station Receiver

Mandolyn Electronic Technology Inc.
Weather Station Receiver - FCC ID PLJWS928 - Mandolyn Electronic Technology Inc.
Click to zoom

Application Details

Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
Date of Grant
Jan 29, 2006
Application Purpose
Original Equipment
Date of Application
Jan 29, 2006
Equipment Note
Weather Station Receiver
Frequency Range
433.92000000 - 433.92000000
Company
Mandolyn Electronic Technology Inc.
Country
Canada

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Press and hold MODE for 3 seconds to Clock Setting mode Press MODE again to Month/Date setting mode Press HOUR/+/MAX to set month Press MINUTE/-/MIN to set date Press MODE to enter Year setting Press HOUR/+/MAX or MINUTE/-/MIN to adjust Year Weekday is automatically determined from the year/month/day setting MONTH & DATE, YEAR SETTING a b c d f P.6 WS928+WT440H Wireless Weather Station KNOW YOUR PRODUCT button placement 1 6 2 3 4 5 Minute/-/Min: shows minimum temperature; adjusts clock, alarm, date & year and temperature alarm values Snooze/Mode: scrolls through Clock 1 & 2, Alarm 1 & 2, Date & Year, and Temperature Alarm(high & low) mode; snooze for alarm LCD display ON/OFF /(C/F): toggles between C and F, 12 and 24 hour format, Alarm 1 & 2 on and off; disables (resets) high & low temperature alarms Channel: scrolls through remote channels Outside, Outside 2 and Outside 3); scrolls through local and remote channels (Outside, Outside 2 and Outside 3) in (high & low) temperature alarm mode; activate learn process Hour/+/Max: shows maximum temperature; adjusts clock, alarm, date & year and temperature alarm values P.1 P.5P.7 P.4 P.8 Inside temperature / humidity trend symbol P.2 or will flash, and the sound volume will gradually from low to high Press SNOOZE to snooze the alarm for 5 minutes, after that the alarm will sound again Press ANY other key will shut off the alarm. Without interruption, the alarm will shut off automatically after one minute ALARM SETTING a b c P.3 7 10 11 8 9 SET: enter to House code and Channel setting mode C/F: change between °C or °F, change channel and house code Battery compartment LCD display Wall mount holder & table stand 7 8 99 Scroll to Alarm1 mode (Alarm2 mode) using MODE Press HOUR to set hour Press MINUTE to set minute Press ON/OFF/(C/F) to set alarm on or off When the alarm is set ON, the bell symbol / will appear 1 2 3 4 5 11 Press and hold MODE for 3 seconds to enter the clock setting mode (the CLOCK 1 symbol appears and the time will flash) Press HOUR to set the hour and MINUTE to set the minute; Press ON/OFF(C/F) during clock setting, to change between 12 and 24 hour display. Do not press any key for 1 minute to finish clock setting Scroll to Clock 2 mode using MODE Press + or - key to change the time i ii iii iv vi v 6 1 2 3 4 5 11 i v vi ii iii 2 1 OUT 1 3 4 OUT 1 4 1 2 3 4 b # e WS928 receiver Inside temperature / humidity reading Outside temperature reading Outside humidity reading Outside temperature trend symbol Outside humidity trend Pressure trend symbol Pressure reading Moon phase Comfort level icon Weather forecast symbols Month/Day, Year Alarm clock Clock Weekday Temperature/ pressure historical bar graph Clock 1 Setting Clock 2 Setting Alarm 1and Alarm 2 setting When alarm sounds d e b f c f # a The colon symbol " " appears if date value is 2-digit (e.g. 13, 26...) * * MANUAL CLOCK SETTING READ THIS BEFORE YOU BEGIN Insert batteries into the remote transmitter(s) first, and then the receiver. For the best operation, Although remote transmitters are weather resistant, it is recommended to place it away from direct sunlight, rain or snow. This will help to make condition readings more accurate. Place the receiver and remote transmitter(s) close together. This will ensure that the receiver synchronizes with remote transmitter(s). Place the remote transmitter(s) outdoors within an effective transmission range. 3 1 * 2 The transmission range can be affected by the dense walls or electronic interference in between the receiver and transmitter. Try various set-ups for best results. # 2 4 6 357 1 1 1 1 % 1 8 GETTING STARTED Remove battery cover and insert 2 AA size batteries. Insert between terminals observing proper polarity then replace cover. 1 Remove battery cover and insert 2 AA size batteries to start setup. The HOUSE CODE will flash for 8 seconds Select the HOUSE CODE by pressing C/F Select CHANNEL(1-4) by pressing C/F. This number will be confirmed upon pressing the SET button, or if no key is pressed for 10 seconds. If only one transmitter is available, it is recommended to leave the CHANNEL be "01” The range of House Codes are from "01" to "15". Make sure all transmitters in your system are set to the same House Code. Humidity & Temperature will display Select °C or °F of Temperature by pressing C/F and pressing SET. Once setup of remote transmitter is completed, it will start transmitting at one minute intervals STEP 1 : setting the remote transmitters * Use a different house code if your weather station detects other signals from neighboring sources * Factory default: house code = 01 and channel = 01 STEP 2 : setting the receiver 8 2 3 4 5 6 7 1 1 2 2 3 4 SYNCHRONIZATION Automatic Learn Function: Manual-Learn Function (Searching for Remote Signals): The Learn function begins automatically and runs for 3 minutes when receiver batteries are first installed. Press and hold Channel for 3 seconds in clock display mode If a new transmitter is added or if signal is lost (outdoor display blinking), the learn function must be executed again. Within these 3 minutes, the receiver will beep and display the temperature & humidity signals from transmitter(s). A beep sound indicates that learn function has started The Outsidethe symbol will flash and unit will beep as each remote sensor is detected Temperature & humidity readings of the remote sensor will display on the receiver. If the signals are not received within this 3 minutes, the outside temperature and humidity will show " ". If this is the case, bring the units closer togther or try a different location. Then restart the auto learning function by temporarily removing the batteries from receiver. * Moon Phase Display MOON PHASE The moon phase is automatically updated according to the year/month/day. New Moon Young Crescent First Quarter Waxing Gibbous Full Moon Waning Gibbous Last Quarter Old Crescent 1 2 8 7 6 5 4 3 WT440H Transmitter 1 OWNERS MANU AL SET C/F - A A 1 . 5 V + - A A 1 . …

Text truncated - open the document above for the full version.

External Photos

CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 2-4216-01-01/06 Date: 2006-01-18 Page 19 of 25 6 Annex C: External Photographs of the Equipment Photo 1: CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 2-4216-01-01/06 Date: 2006-01-18 Page 20 of 25 Photo 2:

ID Label/Location Info

FCC LABEL OF WEATHER STATION, MODEL WS928 MODEL: WS 928 MODEL: WS 928 FCC ID: PLJWS928/ IC: 3981A-WS928 FCC ID: PLJWS928/ IC: 3981A-WS928 Made in China Made in China This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Serial No.: This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Serial No.:

Internal Photos

CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 2-4216-01-01/06 Date: 2006-01-18 Page 21 of 25 7 Annex D: INTERNAL PHOTOGRAPHS OF THE EQUIPMENT Photo 3: CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 2-4216-01-01/06 Date: 2006-01-18 Page 22 of 25 Photo 4: CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 2-4216-01-01/06 Date: 2006-01-18 Page 23 of 25 Photo 5: CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 2-4216-01-01/06 Date: 2006-01-18 Page 24 of 25 Photo 6: CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 2-4216-01-01/06 Date: 2006-01-18 Page 25 of 25 Photo 7:

Test Report

CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 2-4216-01-01/06 Date: 2006-01-18 Page 1 of 25 Recognized by the Federal Communications Commission Anechoic chamber registration no.: 90462 (FCC) Anechoic chamber registration no.: 3463 (IC) TCB ID: DE 0001 Accredited by the German Accreditation Council DAR–Registration Number DAT-P-176/94-D1 Independent ETSI compliance test house ETSI Accredited Bluetooth ® Test Facility (BQTF) Test report no. : 2-4216-01-01/06 Applicant : Mandolyn Electronic Tech. Inc. Type : WS928 Test Standard : FCC Part 15 / RSS210 FCC ID : 3981A-WS928 Certification No. IC : PLJWS928 CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 2-4216-01-01/06 Date: 2006-01-18 Page 2 of 25 Table of contents 1 GENERAL INFORMATION ................................................................................................................................... 3 1.1. ADMINISTRATIVE DATA OF THE TEST FACILITY..................................................................................................... 3 1.1.1 Identification of the testing laboratory ......................................................................................................... 3 1.2. NOTES................................................................................................................................................................... 3 1.3 DETAILS OF APPLICANT......................................................................................................................................... 4 1.4 APPLICATION DETAILS.......................................................................................................................................... 4 1.5 TEST ITEM............................................................................................................................................................. 5 1.6 TEST SETUP........................................................................................................................................................... 6 1.7 TEST SPECIFICATIONS............................................................................................................................................ 6 2 STATEMENT OF COMPLIANCE .......................................................................................................................... 7 2.1 SUMMARY OF MEASUREMENT RESULTS................................................................................................................ 7 2.1.1 CFR 47 Part 15 Radio frequency devices ..................................................................................................... 7 3 MEASUREMENTS AND RESULTS ....................................................................................................................... 8 4 FCC PART 15 SUBPART B ...................................................................................................................................... 9 4.5 Receiver spurious emission (radiated).............................................................................................................. 9 4.6 Plots of measurements .................................................................................................................................... 10 5 ANNEX B: PHOTOGRAPHS OF TEST SITE ..................................................................................................... 17 6 ANNEX C: EXTERNAL PHOTOGRAPHS OF THE EQUIPMENT ................................................................ 19 7 ANNEX D: INTERNAL PHOTOGRAPHS OF THE EQUIPMENT.................................................................. 21 CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 2-4216-01-01/06 Date: 2006-01-18 Page 3 of 25 1 General information 1.1. Administrative data of the test facility 1.1.1 Identification of the testing laboratory Company name: Cetecom ICT Services GmbH Address: Untertürkheimerstr. 6-10 D-66117 Saarbruecken Germany Laboratory accreditation: DAR-Registration No. DAT-P-176/94-D1 Bluetooth Qualification Test Facility (BQTF) Federal Communications Commission (FCC) Identification/Registration No : 90462 Responsible for testing laboratory: Ames Harro Phone: +49 681 598 0 Fax: +49 681 598 9075 email: [email protected] 1.2. Notes The test results of this test report relate exclusively to the test item specified in 1.5. The CETECOM ICT Services GmbH does not assume responsibility for any conclusions and generalizations drawn from the test results with regard to other specimens or samples of the type of the equipment represented by the test item. The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report requires the prior written approval of the CETECOM ICT Services GmbH. ..................................................... / .......................................................... Responsible for testing laboratory (Ames Harro / Jakob Reschke) ...................................................... / .......................................................... Responsible for test report (Ames Harro / Jakob Reschke) CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 2-4216-01-01/06 Date: 2006-01-18 Page 4 of 25 1.3 Details of Applicant Name : Mandolyn Electronic Tech. Inc. Address : 250 Shields Court, Unit 10B City : Markham, Ontario L3R 9W7 Country : Canada Phone : +1-905-305-0923 Fax : +1-905-305-0924 Contact : C.M. Yip Phone : +1-905-305-0923 Fax : +1-905-305-0924…

Text truncated - open the document above for the full version.

Test Setup Photos

CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 2-4216-01-01/06 Date: 2006-01-18 Page 17 of 25 5 Annex B: Photographs of Test site Photo 1 (Radiated Emissions): CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 2-4216-01-01/06 Date: 2006-01-18 Page 18 of 25 Photo 2 (Radiated Emissions):

Contact Information

Applicant

C.M. Yip(Engineering Manager)
[email protected]410 531 3439Fax: 410 531 0807

Test Firm

Cetecom ICT Services GmbHRalf Hoehn
[email protected]49-681-598-8455Fax: 49-681-598-8475

Technical Specifications

#Rule PartsFrequency RangePower Output
115B433.92 MHz - 433.92 MHz-
Confidentiality
Long Term

Other Applications from Mandolyn Electronic Technology Inc.

Wireless Doorbell - FCC ID PLJDB910 - Mandolyn Electronic Technology Inc.
PLJDB910

Wireless Doorbell

Jul 03, 2007

Equipment Class

CYY - Communications Receiver used w/Pt 15 Transmitter
Wireless Doorbell - FCC ID PLJDBT701 - Mandolyn Electronic Technology Inc.
PLJDBT701

Wireless Doorbell

Jul 03, 2007

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Weather Station Receiver - FCC ID PLJWS2635 - Mandolyn Electronic Technology Inc.
PLJWS2635

Weather Station Receiver

Mar 13, 2007

Equipment Class

CRR - Superregenerative Receiver
Weather Station Transmitter - FCC ID PLJWDS500 - Mandolyn Electronic Technology Inc.
PLJWDS500

Weather Station Transmitter

Mar 13, 2007

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Weather Station Receiver - FCC ID PLJWS1200 - Mandolyn Electronic Technology Inc.
PLJWS1200

Weather Station Receiver

Mar 13, 2007

Equipment Class

CRR - Superregenerative Receiver