Technical Specifications
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|
| 12 | 22,9 | 406.1 MHz - 480 MHz | 1 W | 7K60FXW | 2.5
ppm |
Grant NotesPower output listed is rated conducted. This device must be restricted to work-related operations only in an Occupational/Controlled RF exposure environment and must operate with a duty factor not exceeding 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled Exposure limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. Body-worn SAR compliance is limited to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide a minimum of 2.5cm between the device, including its antenna, and the user's body. The highest reported SAR values for Face held and Body-worn accessory are for VHF: 0.09 W/Kg and 0.09 W/Kg for UHF: 0.79 W/kg and 1.19 W/kg respectively when operating at 50% duty cycle.