Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
1 2 Contents C H A P T E R 1 BEFORE USING YOUR PHONE C H A P T E R 2 BASIC OPERATION PACKAGE INCLUDES .....................................................................................08 HANDSET DESCRIPTION ...............................................................................09 DISPLAY INDICATORS...................................................................................11 USING THE BATTERY ....................................................................................12 INSTALLING THE SIM CARD ...............................................................................12 INSTALLING THE BATTERY ................................................................................12 REMOVING THE BATTERY ..................................................................................13 CHARGING THE BATTERY ............................................................................14 BATTERY LIFE (FOR NEW BATTERY) .................................................................15 IMPORTANT BATTERY INFORMATION .......................................................16 DOS........................................................................................................................16 DON’TS..................................................................................................................16 CALL WAITING FUNCTION..................................................................................29 MISSED CALL DISPLAY .......................................................................................29 HOW TO ADJUST VOLUME ................................................................................30 HOW TO STORE A PHONE NUMBER................................................................31 HOW TO MAKE A CALL USING A STORED PHONE NUMBER..........................33 FUNCTION DURING A CALL .........................................................................35 MUTE .....................................................................................................................35 TURN OFF TONES ................................................................................................35 HOLD CALL ...........................................................................................................35 SWITCH CALL .......................................................................................................35 RELEASE ACTION.................................................................................................36 JOIN CALLS ..........................................................................................................36 TRANSFER CALL ..................................................................................................36 RELEASE ALL ........................................................................................................36 TURNING THE PHONE ON AND OFF ...........................................................18 TURNING THE PHONE ON ..................................................................................18 TURNING THE PHONE OFF .................................................................................18 HOW TO USE THE MENU..............................................................................19 MENU SUMMARY .........................................................................................20 BASIC FUNCTIONS ........................................................................................27 MAKING A CALL ...................................................................................................27 HOW TO ANSWER CALLS ...................................................................................28 AUTO ANSWER ....................................................................................................28 CALL ID FUNCTION ..............................................................................................29 C H A P T E R 3 MENU FUNCTION CALL INFO ......................................................................................................38 MISSED CALLS .....................................................................................................38 CALL LIST..............................................................................................................39 CALL COSTS .........................................................................................................40 CALL TIMERS ........................................................................................................43 SET NEXT CALL ....................................................................................................45 OPTIONS ...............................................................................................................46 PHONE SETTINGS .........................................................................................47 PROFILES ..............................................................................................................47 NETWORKS...........................................................................................................51 3 4 CALL OPTIONS .....................................................................................................52 ACCEPT CALLS.................................................................................................52 FORWARD CALLS ............................................................................................54 RESTRICT CALLS..............................................................................................61 CALL WAITING .................................................................................................66 MINUTE MINDER .............................................................................................67 ANSWERING MODE.........................................................................................67 CLAM SHELL ANSWER.......................................…
Text truncated - open the document above for the full version.
Subject: Curitel Communications, Inc. FCC ID: PP4GA-160C REQUEST FOR CONFIDENTIALITY Pursuant to Sections 0.457 (d)(1)(ii) and 0.459 of the Commission’s Rules, Curitel Communications, Inc. hereby requests confidential treatment for portions of the material contained in this application and that the identified material be withheld from public inspection following the grant of this authorization. This material contains trade secrets and proprietary information not customarily released to the public and the public disclosure of these matters might be harmful to Curitel Communications, Inc. and provide unjustified benefits to its competitors. Confidentiality is requested for the following exhibits: ● Exhibit 4 Block Diagram ● Exhibit 5 Schematics ● Exhibit 10 List of Active Devices and Tune-Up Procedure ● Exhibit 12 Operational Description Curitel Communications, Inc. understands that pursuant to Rule 0.457 (d)(1)(ii) disclosure of this Application and all accompanying documentation will not be made before the date of the Grant for this Application. Sincerely, David (Daejung) Kim Director of Engineer Curitel Communications, Inc. Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21046 January 10, 2003 Curitel Communications, Inc. Peungwha Seocho Bldg., 1451-34, Seocho-dong, Seocho-Gu, Seoul, 137-070, Korea
FCC ID SAMPLE LABEL & LOCATION LABELING REQUIREMENTS PER §§2.925 The Label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time of purchase. (SEE NEXT PAGE) CURITEL COMMUNICATIONS, INC. CURITEL COMMUNICATIONS, INC. MODEL NO: GA-160C FCC ID: PP4GA-160C Made in KOREA
SAR Test Report No. SAR_408_2003_FCC_850_1900 Date of Report:02/28/2003 Appendix A Measurement Plots Page 1 of 28 -850 MHz Band Head SAR Plots: Plot 1. Date: 1/7/2003 Temperature Air / Liquid: 20.1°C / 20.6°C Liquid mass density (ρ): 1 DCP 1 X=9, Y=13.6, Z=8.7 Probe S/N:0123 Air Factor X=346, Y=318, Z=386 Probe S/N:0123 liquid/air conversion Factor 0.401 Simulated tissue dielectric parameters: ε r : 41.84 σ: 0.899 Position: Left touch extended Channel / Frequency 190 / 836.6 MHz Maximum 1 gram SAR: 0.097W/Kg Maximum 10 gram SAR: 0.063W/Kg Power reference start: 0.043W/Kg Power reference end 0.041W/Kg Power reference change 2 -4.09% 1 DCP: Diode compression potential for different types of modulation is determined during the calibration of the probe. See section 6.2 of this report Probe and Amplifier Specification. Crest factor is not used. 2 The power reference change is calculated by the test system with more digits than indicated in the power reference start and end values. SAR Test Report No. SAR_408_2003_FCC_850_1900 Date of Report:02/28/2003 Appendix A Measurement Plots Page 2 of 28 Plot 2. Date: 1/7/2003 Temperature Air / Liquid: 20.1°C / 20.6°C Liquid mass density (ρ): 1 DCP 1 X=9, Y=13.6, Z=8.7 Probe S/N:0123 Air Factor X=346, Y=318, Z=386 Probe S/N:0123 liquid/air conversion Factor 0.401 Simulated tissue dielectric parameters: ε r : 41.84 σ: 0.899 Position: Left touch retracted Channel / Frequency 190 / 836.6 MHz Maximum 1 gram SAR: 0.181W/Kg Maximum 10 gram SAR: 0.122W/Kg Power reference start: 0.089W/Kg Power reference end 0.089W/Kg Power reference change 2 -0.00% 1 DCP: Diode compression potential for different types of modulation is determined during the calibration of the probe. See section 6.2 of this report Probe and Amplifier Specification. Crest factor is not used. 2 The power reference change is calculated by the test system with more digits than indicated in the power reference start and end values. SAR Test Report No. SAR_408_2003_FCC_850_1900 Date of Report:02/28/2003 Appendix A Measurement Plots Page 3 of 28 Plot 3. Date: 1/7/2003 Temperature Air / Liquid: 20.1°C / 20.6°C Liquid mass density (ρ): 1 DCP 1 X=9, Y=13.6, Z=8.7 Probe S/N:0123 Air Factor X=346, Y=318, Z=386 Probe S/N:0123 liquid/air conversion Factor 0.401 Simulated tissue dielectric parameters: ε r : 41.84 σ: 0.899 Position: Left tilt retracted Channel / Frequency 190 / 836.6 MHz Maximum 1 gram SAR: 0.051W/Kg Maximum 10 gram SAR: 0.036W/Kg Power reference start: 0.028W/Kg Power reference end 0.028W/Kg Power reference change 2 -0.00% 1 DCP: Diode compression potential for different types of modulation is determined during the calibration of the probe. See section 6.2 of this report Probe and Amplifier Specification. Crest factor is not used. 2 The power reference change is calculated by the test system with more digits than indicated in the power reference start and end values. SAR Test Report No. SAR_408_2003_FCC_850_1900 Date of Report:02/28/2003 Appendix A Measurement Plots Page 4 of 28 Plot 4. Date: 1/7/2003 Temperature Air / Liquid: 20.1°C / 20.6°C Liquid mass density (ρ): 1 DCP 1 X=9, Y=13.6, Z=8.7 Probe S/N:0123 Air Factor X=346, Y=318, Z=386 Probe S/N:0123 liquid/air conversion Factor 0.401 Simulated tissue dielectric parameters: ε r : 41.84 σ: 0.899 Position: Left tilt extended Channel / Frequency 190 / 836.6 MHz Maximum 1 gram SAR: 0.024W/Kg Maximum 10 gram SAR: 0.016W/Kg Power reference start: 0.010W/Kg Power reference end 0.010W/Kg Power reference change 2 -4.20% 1 DCP: Diode compression potential for different types of modulation is determined during the calibration of the probe. See section 6.2 of this report Probe and Amplifier Specification. Crest factor is not used. 2 The power reference change is calculated by the test system with more digits than indicated in the power reference start and end values. SAR Test Report No. SAR_408_2003_FCC_850_1900 Date of Report:02/28/2003 Appendix A Measurement Plots Page 5 of 28 Plot 5. Date: 1/7/2003 Temperature Air / Liquid: 20.1°C / 20.6°C Liquid mass density (ρ): 1 DCP 1 X=9, Y=13.6, Z=8.7 Probe S/N:0123 Air Factor X=346, Y=318, Z=386 Probe S/N:0123 liquid/air conversion Factor 0.401 Simulated tissue dielectric parameters: ε r : 41.84 σ: 0.899 Position: Right touch extended Channel / Frequency 190 / 836.6 MHz Maximum 1 gram SAR: 0.116W/Kg Maximum 10 gram SAR: 0.075W/Kg Power reference start: 0.057W/Kg Power reference end 0.057W/Kg Power reference change 2 -0.00% 1 DCP: Diode compression potential for different types of modulation is determined during the calibration of the probe. See section 6.2 of this report Probe and Amplifier Specification. Crest factor is not used. 2 The power reference change is calculated by the test system with more digits than indicated in the power reference start and end values. SAR Test Report No. SAR_408_2003_FCC_850_1900 Date of Report:02/28/2003 Appendix A Measurement Plots Page 6 of 28 Plot 6. Date: 1/7/2003 Temperature Air / Liquid: 20.1°C / 20.6°C Liquid mass density (ρ): 1 DCP 1 X=9, Y=13.6, Z=8.7 Probe S/N:0123 Air Factor X=346, Y=318, Z=386 Probe S/N:0123 liquid/air conversion Factor 0.401 Simulated tissue dielectric parameters: ε r : 41.84 σ: 0.899 Position: Right touch retracted Channel / Frequency 190 / 836.6 MHz Maximum 1 gram SAR: 0.193W/Kg Maximum 10 gram SAR: 0.128W/Kg Power reference start: 0.097W/Kg Power reference end 0.095W/Kg Power reference change 2 -1.99% 1 DCP: Diode compression potential for different types of modulation is determined during the calibration of the probe. See section 6.2 of this report Probe and Amplifier Specification. Crest factor is not used. 2 The power reference change is calculated by the test system with more digits than indicated in the power reference start and end values. SAR Test Report No. SAR_408_2003_FCC_850_1900 Date of Report:02/28/2003 Appendix A Measurement Plots Page 7 of 28 Plot 7. Date: 1/7/2003 Temperature Air / Liquid: 20.1°C / 20.6°C Liquid mass density (ρ…
Text truncated - open the document above for the full version.
SAR Test Report No. SAR_408_2003_FCC_850_1900 Date of Report:02/28/2003 Appendix B Photographs Page 1 of 16 EUT Photos: Photo 1. EUT front closed SAR Test Report No. SAR_408_2003_FCC_850_1900 Date of Report:02/28/2003 Appendix B Photographs Page 2 of 16 Photo 2. EUT front open SAR Test Report No. SAR_408_2003_FCC_850_1900 Date of Report:02/28/2003 Appendix B Photographs Page 3 of 16 Photo 3 EUT back SAR Test Report No. SAR_408_2003_FCC_850_1900 Date of Report:02/28/2003 Appendix B Photographs Page 4 of 16 Set-up Photos: Photo 4. Left touch retracted SAR Test Report No. SAR_408_2003_FCC_850_1900 Date of Report:02/28/2003 Appendix B Photographs Page 5 of 16 Photo 5. Left touch extended SAR Test Report No. SAR_408_2003_FCC_850_1900 Date of Report:02/28/2003 Appendix B Photographs Page 6 of 16 Photo 6. Left tilt retracted SAR Test Report No. SAR_408_2003_FCC_850_1900 Date of Report:02/28/2003 Appendix B Photographs Page 7 of 16 Photo 7. Left tilt extended SAR Test Report No. SAR_408_2003_FCC_850_1900 Date of Report:02/28/2003 Appendix B Photographs Page 8 of 16 Photo 8. Right touch retracted SAR Test Report No. SAR_408_2003_FCC_850_1900 Date of Report:02/28/2003 Appendix B Photographs Page 9 of 16 Photo 9. Right touch extended SAR Test Report No. SAR_408_2003_FCC_850_1900 Date of Report:02/28/2003 Appendix B Photographs Page 10 of 16 Photo 10. Right tilt retracted SAR Test Report No. SAR_408_2003_FCC_850_1900 Date of Report:02/28/2003 Appendix B Photographs Page 11 of 16 Photo 11. Right tilt extended SAR Test Report No. SAR_408_2003_FCC_850_1900 Date of Report:02/28/2003 Appendix B Photographs Page 12 of 16 Photo 12. Body SAR retracted SAR Test Report No. SAR_408_2003_FCC_850_1900 Date of Report:02/28/2003 Appendix B Photographs Page 13 of 16 Photo 13. Body SAR extended SAR Test Report No. SAR_408_2003_FCC_850_1900 Date of Report:02/28/2003 Appendix B Photographs Page 14 of 16 Photo 14. Body SAR distance SAR Test Report No. SAR_408_2003_FCC_850_1900 Date of Report:02/28/2003 Appendix B Photographs Page 15 of 16 Photo 15. Photo to demonstrate 15 cm Z-axis head phantom SAR Test Report No. SAR_408_2003_FCC_850_1900 Date of Report:02/28/2003 Appendix B Photographs Page 16 of 16 Photo 16. Photo to demonstrate 15 cm Z-axis flat phantom
SAR Test Report No: SAR_408_2003_FCC_800_1900 Date of Report: 02/28/2003 Appendix C Page 1 of 40 Tissue Parameters 850MHz Head liquid: Recipe: The following recipe is provided in percentage by weight. 49.46% distilled water 49.46% DGBE 1.0% salt 0.1% bactericide Di-electric constants measured on 01/07/2003. SAR measurements were made within 24 hours of the measurement of liquid parameters. Freq. Rel. Condy (MHz) Perm. (S/m) 824.2 42.02 0.89 836.6 41.84 0.899 848.8 41.62 0.918 900 41.2 0.973 Conductivity 0.85 0.9 0.95 1 1.05 820845870895 frequency (MHz) conductivity (S/m) 900 / 835 MHz liquid 1528 std +5% -5% Permittivity 35 37 39 41 43 45 820845870895 fre que ncy (M Hz) relative permittivity 900 / 835 MHz liquid 1528 std +5% -5% SAR Test Report No: SAR_408_2003_FCC_800_1900 Date of Report: 02/28/2003 Appendix C Page 2 of 40 850MHz Body Liquid: Recipe: The following recipe is provided in percentage by weight. 49.8% distilled water 40.6% DGBE 8.9% salt 0.6% HEC 0.1% bactericide Di-electric constants measured on 01/07/2003. SAR measurements were made within 24 hours of the measurement of liquid parameters. Freq. Rel. Condy (MHz) Perm. (S/m) 824.2 56.07 0.973 836.6 55.55 0.987 848.8 55.46 0.983 Conductivity 0.9 0.95 1 1.05 1.1 824830836842848 frequency (MHz) conductivity (S/m) 900 / 835 MHz body liquid 1528 std Permittivity 51 52 53 54 55 56 57 58 59 824830836842848 frequency (MHz) relative permittivity 900 / 835 MHz body liquid 1528 std SAR Test Report No: SAR_408_2003_FCC_800_1900 Date of Report: 02/28/2003 Appendix C Page 3 of 40 1900MHz Head liquid: Recipe: The following recipe is provided in percentage by weight. 54.9% distilled water 44.92% DGBE 0.18% salt 0.1% bactericide Di-electric constants measured on 01/08/2003. SAR measurements were made within 24 hours of the measurement of liquid parameters. Freq. Rel. Condy (MHz) Perm. (S/m) 1850.2 39.66 1.403 1880 39.38 1.424 1900 39.29 1.437 1909.8 39.12 1.45 Conductivity 1.32 1.37 1.42 1.47 1.52 1.57 1850187519001925 frequency (MHz) conductivity (S/m) 1900 MHz head liquid 1528 std Permittivity 37 38 39 40 41 42 43 1850187519001925 frequency (MHz) relative permittivity 1900 MHz head liquid 1528 std +5% -5% SAR Test Report No: SAR_408_2003_FCC_800_1900 Date of Report: 02/28/2003 Appendix C Page 4 of 40 1900MHz Body Liquid: Recipe: The following recipe is provided in percentage by weight. 69.17% distilled water 30.29% DGBE 0.44% salt 0.1% bactericide Di-electric constants measured on 01/08/2003. SAR measurements were made within 24 hours of the measurement of liquid parameters. Freq. Rel. Condy (MHz) Perm. (S/m) 1850.2 53.35 1.563 1880 53.16 1.576 1909.8 52.96 1.58 Conductivity 1.4 1.45 1.5 1.55 1.6 1.65 1850187018901910 frequency (MHz) conductivity (S/m) 1900Body liquid 1528 std +5% -5% Pe rmittivity 49 50 51 52 53 54 55 56 57 1850187018901910 frequency (MHz) relative permittivity 1900Body liquid 1528 std +5% -5% Environment 01/07/2003 – 01/09/2003: Temperature: 22.0 °C ± 2°C Humidity: 45% _ 55 % SAR Test Report No: SAR_408_2003_FCC_800_1900 Date of Report: 02/28/2003 Appendix C Page 5 of 40 Test Equipment Test Equipment Model Serial Instrument description Supplier/Manufacturer Model Serial No. Calibration (date) Bench top Robot Mitsubishi supplied by Indexsar RV-E2 Serial No. N/A SAM Phantom Upright shell phantom made by Antennessa digitized and mounted by Indexsar SAM 04/02 FT08 N/A 850MHz Head Tissue Simulant Cetecom Inc. 850 Head N/A 01/07/2003 850MHz Body Tissue Simulant Cetecom Inc. 850 Body N/A 01/07/2003 1900MHz Head Tissue Simulant Cetecom Inc. 1900 Head N/A 01/08/2003 1900MHz Body Tissue Simulant Cetecom Inc. 1900 Body N/A 01/08/2003 900MHz Dipole IndexSAR – IEEE 1528 design IXD-090 090-0016 07/01/02 1900MHz Dipole IndexSAR – IEEE 1528 design IXD-190 190-0016 7/30/02 Directional coupler Werlatone C6529 11249 N/A Netwok Analyzer Agilent 8753ES US39172511- 04/04/2002- RF Amplifier Vectawave N/A N/A N/A Power Meter Rohde and Schwartz NRVD 836875/020 5/2002 Power Sensor Rohde and Schwartz URV5-Z2 836029/034 5/2002- Power Sensor Rohde and Schwartz URV5-Z2 836029/035 5/2002- SAR Probe IndexSAR IXP-050 0123 10/25/2002 Probe amplifier Indexsar IXA-010 043 N/A- Thermometer Control Company 4039 20410549 11/20/2002 Dielectric Measurement Kit IndexSar Di-Line N/A N/A SAR Test Report No: SAR_408_2003_FCC_800_1900 Date of Report: 02/28/2003 Appendix C Page 6 of 40 Equipment Calibration/Performance Documents: Validation Dipoles Performance Measurements: Pages 7 to 17. Immersible SAR probe Calibration Report: Pages 18 to 40 Please Note: (The following pages of Appendix C show calibration documents. These calibration documents are inserted into this appendix. The header information with page numbering scheme is a part of this report and is included on all pages of the report and appendixes. This header is used to track all of the contents of this report.) SAR Test Report No: SAR_408_2003_FCC_800_1900 Date of Report: 02/28/2003 Appendix C Page 7 of 40 Report No. SN0016_090-180-245 July 1 st 2002 INDEXSAR Validation Dipoles Type IXD-090, IXD-180 & IXD-245 Performance measurements S/N: 090-0016 S/N: 180-0016 S/N: 245-0016 MI Manning Indexsar, Oakfield House, Cudworth Lane, Newdigate, Surrey RH5 5DR. UK. Tel: +44 (0) 1306 631233 Fax: +44 (0) 1306 631834 e-mail: [email protected] SAR Test Report No: SAR_408_2003_FCC_800_1900 Date of Report: 02/28/2003 Appendix C Page 8 of 40 1. Measurement Conditions Measurements were performed using a box-shaped phantom made of PMMA with dimensions designed to meet the accuracy criteria for reasonably-sized phantoms that do not have liquid capacities substantially in excess of the volume of liquid required to fill the Indexsar upright SAM phantoms used for SAR testing of handsets against the ear. An HP 8753B vector network analyser was used for the return loss measurements. The dipole was placed in a special holder made of low-permittivity, low-loss materials. This holder enables the dipole to be positioned accura…
Text truncated - open the document above for the full version.
Accredited according to ISO/IEC 17025 by: TTI-P-G 81/94-A0 CETECOM Inc. 411 Dixon Landing Road Milpitas, CA 95035 U.S.A. Phone: + 1 (408) 586 6200 Fax: + 1 (408) 586 6299 E-mail: [email protected] http://www.cetecom.com CETECOM Inc. is a Delaware Corporation with Corporation number: 2113686 Board of Directors: Dr. Harald Ansorge, Dr. Klaus Matkey, Hans Peter May V.2.16M-2002-03-12 f:\emc\projects\curitel\408-2003_mbw10_ga-160c\sar\report\408_2003_fcc_850_1900.doc © Copyright by CETECOM SAR Test Report No. 408_2003_FCC_850_1900 for the Curitel Communications Inc. GSM/GPRS DualBand for 1900 and 850 MHz Model Number: GA160C FCC ID: PP4 GA-160C Date of Report: 02/28/2003 Date of issue: 02/28/2003 Report Copy No.: 01 SAR Test Report No. Date of Report: Page 2 of 28 Error! Reference source not found. This report shall not be reproduced except in full without the written approval of: CETECOM Inc. SAR 411 Dixon Landing Road Milpitas, CA 95035 U.S.A. Contents 1. ASSESSMENT ...................................................................................................................4 2. ADMINISTRATIVE DATA...................................................................................................5 2.1. Identification of the Testing Laboratory Issuing the SAR Assessment Report ...............5 2.2. Identification of the Client...........................................................................................5 2.3. Identification of the Manufacturer...............................................................................5 3. EQUIPMENT UNDER INVESTIGATION (EUI)...................................................................6 3.1. Identification of the Equipment under Investigation ...................................................6 3.2. Front View of the Equipment under Investigation ......................................................7 4. SUBJECT OF INVESTIGATION ........................................................................................8 4.1. The IEEE Standard C95.1 and the FCC Exposure Criteria .......................................8 4.2. Distinction Between Exposed Population, Duration of Exposure and Frequencies...8 4.3. Distinction between Maximum Permissible Exposure and SAR Limits......................9 4.4. SAR Limit ...................................................................................................................9 5. THE FCC MEASUREMENT PROCEDURE .....................................................................10 5.1. General Requirements.............................................................................................10 5.2. Device Operating Next to a Person’s Ear ................................................................10 5.3. Test positions of device relative to head..................................................................11 5.4. Test to be Performed ...............................................................................................14 5.5. Body-worn and Other Configurations.......................................................................14 5.6. Procedure for assessing the peak spatial-average SAR .........................................15 5.7. Determination of the largest peak spatial-average SAR ..........................................17 6. THE MEASUREMENT SYSTEM ......................................................................................18 6.1. Robot system specification ......................................................................................18 6.2. Probe and amplifier specification .............................................................................19 6.3. Phantoms.................................................................................................................19 6.4. SAR measurement procedure .................................................................................20 6.5. SARA2 Interpolation and Extrapolation schemes ....................................................20 SAR Test Report No. Date of Report: Page 3 of 28 Error! Reference source not found. This report shall not be reproduced except in full without the written approval of: CETECOM Inc. SAR 411 Dixon Landing Road Milpitas, CA 95035 U.S.A. 6.6. Interpolation of 2D area scan...................................................................................21 6.7. Extrapolation of 3D scan..........................................................................................21 6.8. Interpolation of 3D scan and volume averaging.......................................................21 7. UNCERTAINTY ASSESSMENT.......................................................................................23 7.1. Measurement Uncertainty Budget ...........................................................................24 8. TEST RESULTS SUMMARY............................................................................................25 8.1. Description of EUT test positions and operation modes ..........................................25 8.2. Conducted Output Power.........................................................................................25 8.3. Head SAR results for GSM 850MHz band for GA160C...........................................26 8.4. Body SAR results for GSM 850MHz band for GA160C ...........................................26 8.5. Head SAR results for GSM 1900MHz band for GA160C.........................................26 8.6. Body SAR results for GSM 1900MHz band for GA160C .........................................27 8.7. [Validation Check Results ........................................................................................27 9. REFERENCES..................................................................................................................28 SAR Test Report No. Date of Report: Page 4 of 28 Error! Reference source not found. This report shall not be reproduced except in full without the written ap…
Text truncated - open the document above for the full version.
Freq. Amplitude Phase Rel. Condy (MHz) (dB) (deg) Perm. (S/m) 835 -24.574 -155.2454.660.964 900 -25.362 -195.8954.891.01 Freq. Amplitude Phase Rel. Condy (MHz) (dB) (deg) Perm. (S/m) 1880 -35.194 -57.07752.751.55 1900 -35.426 -65.62152.471.56 W/k Prior to formal testing at each frequency a system verification was performed in accordance with IEEE 1528. The balanced dipole source was placed at the specified distance in horizontal orientation. All of the testing described in this report was performed within 24 hours of the system verification. The following results were obtained: Date Frequency (MHz) CW input at dipole feed (Watts) Max measured1g SAR (W/kg) Max measured1g SAR normalized to 1 Watt (W/kg) 1 Watt reference SAR value from IEEE 1528 (W/kg) Difference reference SAR value to normalized SAR 03/05/2004 900 1.0 10.28 10.28 10.8 -4.82% 03/05/2004 1900 1.0 40.61 40.61 39.7 +2.29% Conducted output power: Channel 190 30.2 dBm Channel 661 28.9 dBm Date / Time: 3/5/2004 8:44:10 AM Position: antenna toward phantom 17 mm Filename: *.txt Phantom: HeadBox_new_spout.csv Device Tested: Curitel GA-160C Head Rotation: 0 Antenna: integral Test Frequency: 836.6 Shape File: Curitel_MBW20_body.csv Power Level: max 2 timeslots TX Probe: 0106 Cal File: 106_835_BODY_28 X Y Z Air 415 805 371 DCP 12.81 5.68 11.4 Cal Factors: Lin 0.357 0.357 0.357 Amp Gain: 32 Averaging: 6 Batteries Replaced: 02/11/04 Liquid: 835 Type: Body Conductivity: 0.957 Relative Permittivity: 54.66 Liquid Temp (deg C): 22.0 Ambient Temp (deg C): 22.0 Ambient RH (%): 50 Density (kg/m3): 1000 Software Version: 0.420 ZOOM SCAN RESULTS: Start Scan End Scan Spot SAR (W/kg): 0.150 0.146 Change during Scan (%) -2.73 Max E-field (V/m): 18.34 1g 10g Max SAR (W/kg) 0.287 0.206 X Y Z Location of Max (mm): 75.0 -6.0 -143.2 AREA SCAN: Min Max Steps Y -80.0 20.0 10.0 Scan Extent: Z -190.0 -100.0 10.0 Date / Time: 3/5/2004 10:54:00 AM Position: antenna toward phantom 17 mm Filename: *.txt Phantom: HeadBox_new_spout.csv Device Tested: Curit…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 2 | 24E | 1.85 GHz - 1.91 GHz | 1.691 W | 300KGXW | 0.02 ppm |

Dual-Band CDMA Phone
Equipment Class
PCE - PCS Licensed Transmitter held to earDual-Band CDMA PCS Phone with Bluetooth
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Dual-Band CDMA Phone with Bluetooth (CDMA/PCS CDMA)
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Dual Band CDMA Phone with Bluetooth (CDMA/PCS CDMA
Equipment Class
PCE - PCS Licensed Transmitter held to ear
Dual-Band CDMA Phone W/ Bluetooth
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter