FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

ยฉ 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Xeline Co., LTd./
  3. PQVMM-202BX

PQVMM-202BXPLC Modem

Xeline Co., LTd.
PLC Modem - FCC ID PQVMM-202BX - Xeline Co., LTd.
Click to zoom

Application Details

Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
Date of Grant
Dec 21, 2005
Application Purpose
Original Equipment
Date of Application
Dec 21, 2005
Equipment Note
PLC Modem
Company
Xeline Co., LTd.
Country
South Korea

Documents & Files

Select a file to view

Users Manual

โ†—

Block Diagram

โ†—

Cover Letter(s)

โ†—

External Photos

โ†—

ID Label/Location Info

โ†—

Internal Photos

โ†—

Operational Description

โ†—

Test Report

โ†—

Test Setup Photos

โ†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

MM-202BX Installation Manual PLC Master Unit Plug into the future Powerline Communication by Xeline Xeline Co., Ltd. MM-202BX Installation Manual This document is subject to change without prior notice. 2 ATTENTION This equipment conforms with the following CE standard(s): (1) EN55022 (2) EN60950-1 MM-202BX Installation Manual This document is subject to change without prior notice. 3 Table of Contents 1. Introductionยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท5 2. Before Installing the MM-202BXยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท6 2.1 Package Contentsยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท6 2.2 Installation Environmentยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท6 2.3 Guidelines for Installationยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท7 2.4 Safety Precautionsยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท7 3. Getting to Know the MM-202BXยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท8 3.1 Front Viewยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท8 3.2 Top Viewยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท8 3.3 Bottom Viewยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท8 3.4 Product Specificationsยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท9 4. Installing the MM-202BXยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท10 4.1 Connecting the Powerยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท10 4.2 Configuring the MM-202BXยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท10 4.3 Connecting the CU-100A to the MM-202BXยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท10 4.4 Connecting the MM-202BX to the ISP Backboneยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท11 4.5 Checking the Final Connectionsยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท11 4.6 Resetting to Factory Default Modeยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท12 5. Trouble Shootingยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท13 6. Appendixยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท14 MM-202BX Installation Manual This document is subject to change without prior notice. 4 Figure Index Figure 1 XPAS-200B PLC Internet Access System Configuration! . Figure 2 MM-202BX Package Contents........................................................6 Figure 3 MM-202BX Front View................................................................8 Figure 4 MM-202BX Top View..................................................................8 Figure 5 MM-202BX Bottom View..............................................................9 Figure 6 Connecting the MM-202BX to the CU-100A.......................................10 Figure 7 Connecting the MM-202BX to the ISP backbone.................................11 MM-202BX Installation Manual This document is subject to change without prior notice. 5 1. Introduction Powerline Communication (PLC) technology uses the existing powerline infrastructure to transfer high-speed data, eliminating the need for expensive and complicated cable installation. Because the home or office is already a โ€˜wired networkโ€™ through powerlines, Xelineโ€™s PLC system offers a cost-effective and easy-to-install Internet access solution from any electrical outlet. Xeline's XPAS-200B PLC Internet Access System supports data rates of up to 24Mbps and is targeted for effective Internet access over powerlines in residential houses or high-rise building configurations. The XPAS-200B system supports both Master/Slave or Ad-hoc topology and is based on Xeline's proprietary Cell-structured MAC (CMAC), which offers virtually unlimited number of nodes per physical network. Remote configuration and firmware upgrade are also supported for efficient setup and maintenance of the PLC units in mass-usage environments. Xeline's XPAS-200B system supports EMS (Element Management System) for effective remote monitoring and management of the PLC networks. MM-202BX Installation Manual This document is subject to change without prior notice. 6 2. Before Installing the MM-202BX 2.1 Package Contents Before installing, first verify that you have all of the following items. MM-202BX PLC Master Unit 1 AC power cable 1 Installation manual 1 RJ-45 cable (CAT 5) Figure 1 MM-202BX Package Contents If there is a missing item or any visible damage, notify your service provider or dealer immediately. 2.2 Installation Environment In order to install the MM-202BX, the following conditions must be met: (1) Power supply for the MM-202BX (2) Convenient access to the local backbone network (3) Sufficient space to install the MM-202BX and CU-100A (PLC Coupler) Note: In indoor configurations, one of the optimal locations for the MM-202BX is near the distribution station. (4) 1 Laptop PC 1 (5) RJ-45 direct cable (Core manufactured by: E-Tech Electronics Co., Ltd. Model No. cu1330b) (6) 1 SU-200BX (test unit) to check the PLC connection with the MM-202BX (7) 1 Switch Hub for connecting multiple MM-202BX and EU-200BX units (optional) MM-202BX Installation Manual This document is subject to change without prior notice. 7 2.3 Guidelines for Installation Please make sure to read the following guidelines before installation. (1) Install the MM-202BX on the inner side of power-supplied distribution panel of a building. In case there is not enough space to install inside, install it on the external wall of the distribution panel. (2) When installing on the external wall of the distribution panel, prepare a protective enclosure to protect the device and to prevent effects fromโ€ฆ

Text truncated - open the document above for the full version.

Block Diagram

1.SMPS PART DC OUTPUT COUPLING PART 2.AFE 3.AD9975 4.XPLC21 5.ADM6992 8.RJ45 PORT Mixed Signal Front End AD Converter, DA Converter, AGC Analog Front End, Filter, OP Amp PLC PHY, PLC MAC Ethernet switch controller 6.OSC 50MHz 7.EEPRO M DC 12V, 3.3V SIGNAL LINE 100MHz 25MHz BLOCK DIAGRAM 9.MAX232 9.RS232 PORT EIA232 DRIVER

Cover Letter(s)

5F Seowon Bldg., 1515-4 Seocho3-dong, Seocho-gu, Seoul,137-871, Korea Date: December 14, 2005 Compliance Certification Services Certification Division 561F Monterey Road Morgan Hill, CA 95037 To whom it may concern: We, the undersigned, hereby authorize ETL Inc., to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by ETL Inc.on our behalf shall have the same effect as acts of our own. In authorizing ETL Inc.as our agent, we still recognize that we are responsible to: a) comply with the relevant provisions of the certification program; b) make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints; c) make claims regarding certification only in respect of the scope for which certification has been granted; d) do not use our product certification in such a manner as to bring the Certification Division into disrepute and not make any statement regarding our product certification which the Certification Division may consider misleading or unauthorized; e) upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by the Certification Division; f) use certification only to indicate the products are certified as being in conformity with specified standards; g) endeavor to ensure that no certificate or report nor any part thereof is used in a misleading manner; 5F Seowon Bldg., 1515-4 Seocho3-dong, Seocho-gu, Seoul,137-871, Korea h) ensure that any reference to our product certification in communication media such as documents, brochures or advertising, complies with the requirements of the Certification Division; i) keep a record of all complaints made known to the us relating to the productโ€™s compliance with requirements of the relevant standard and to make these records available to the Certification Division when requested; j) take appropriate action with respect to such complaints and any deficiencies found in products or services that affect compliance with the requirements for certification; k) document the actions taken. This authorization is valid until further written notice from the applicant. Sincerely Yours, Signature Name IL-Soo, Kim Title: Senior Manager Company: Xeline Co., Ltd. . REMARK: 1. This authorization letter will be sent along with your application when filing with the Certification Division. 2. Please follow the format and type it on company letterhead and send original to us.

External Photos

Appendix C. External Photographs E05.1124.FCC.743N / Page C1 of C1 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab: #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel:82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 Front View of EUT Rear View of EUT

ID Label/Location Info

Appendix A. FCC ID Label and Location E05.1124.FCC.743N / Page A1 of A1 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab: #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel: 82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 Product label sample with FCC label information Following is a sample copy of the label that will be placed on the rear cabinet of the product. The FCC ID label and compliance statement are marked in the product label. Label Location The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time purchase.(Labeling requirements per 2.925) Xeline Co., Ltd. PLC Modem FCC ID : PQVMM-202BX Model No : MM-202BX Power : 110 Vac - 240 Vac, 50/60 Hz, 0.25 A Serial No : N/A This device complies with Part 15 of the FCC Rules. Operation is Subject to the following two conditions: (1) this device may not Cause harmful interference, and(2) this device must accept any Interference received, including interference that may cause undesired Operation. Made in Korea Label here

Internal Photos

Appendix D. Internal Photographs E05.1124.FCC.743N / Page D1 of D6 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab: #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel:82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 View of Inside Appendix D. Internal Photographs E05.1124.FCC.743N / Page D2 of D6 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab: #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel:82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 Component side view of Main board Appendix D. Internal Photographs E05.1124.FCC.743N / Page D3 of D6 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab: #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel:82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 Solder side view of Main board Appendix D. Internal Photographs E05.1124.FCC.743N / Page D4 of D6 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab: #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel:82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 Component side view of power Appendix D. Internal Photographs E05.1124.FCC.743N / Page D5 of D6 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab: #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel:82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 Solder side view of power Appendix D. Internal Photographs E05.1124.FCC.743N / Page D6 of D6 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab: #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel:82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 Top main cover Bottom main cover

Operational Description

Operational Description 1. SMPS PART A. DC OUTPUT : Supplies DC power to enable product operation. (3.3V & 12V) B. COUPLING PART : Couples the PLC signals to the powerlines. 2. AFE (ANALOG FRONT END) : Filters and amplifies analog signals. 3. AD9975 (A/D & D/A CONVERTER): A. Converts analog signals to digital signals and vice versa. B. Provides 100MHz frequency needed for XPLC21 operation. 4. XPLC21 (PLC PHY & PLC MAC) : A. 24Mbps PLC chip, B. Supports 256 PSK DMT C. Packatizes Ethernet data and transmits to a remote modem through the powerline channels. D. Can be used for access network or home networking purposes. 5. ADM6992 (ETHERNET SWINCHING CHIPSET) A. Performs Ethernet switching of the Ethernet MII data from the XPLC21 and converts to PHY 6. OSC 50MHZ : Generates basic frequency needed for product operation 7. EEPROM : Saves basic configuration data of the XPLC21 8. RJ45 PORT : Port for Ethernet communication 9. MAX232 : Converts serial data from TTL LEVEL to EIA232 10. RS232 PORT : Port for serial communcation

Test Report

www.etl.re.kr E-RAE Testing Laboratory The test result only responds to the tested sample. It is not allowed to copy this report even partly without the allowance of the test laboratory. Form NO: ETL(E)004A4001201- 0. Electromagnetic Emission FCC MEASUREMENT REPORT CERTIFICATION OF COMPLIANCE FCC Part 15 Certification Measurement This is PLC Modem, Model: MM-202BX has been tested inaccordance with the measurement procedures specified in ANSI C63.4-2001 at the ETL/EMC Test Laboratory and has been shown to be complied with the electromagnetic radiated emission limits specified in FCC Rule Part15 Subpart B: I attest to the accuracy of data. All measurement here in was performed by me or was made under my supervision and is correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. The results of testing in this report apply to the product/system, which was tested only. Other similar equipment will not necessarily produce the same results due to production tolerance and measurement uncertainties. Hyung Seok, Lee / Chief EngineerETL Inc. #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea PRODUCT: PLC Modem MODEL/TYPE NO: MM-202BX FCC ID: PQVMM-202BX APPLICANT / ADDRESS : Xeline Co., Ltd. 5F Seowon Bldg., 1515-4 Seocho3-dong, Seocho-gu, Seoul, 137-871, Korea Attn.: IL-Soo, Kim / Senior Manager Manufacture / Address Same as applicant FCC CLASSIFICATION: Class B personal computers and peripherals FCC RULE PART(S): FCC Part 15 Subpart B FCC PROCEDURE: Certification TRADE NAME: N/A TEST REPORT No. : E05.1124.FCC.743N DATES OF TEST: November 07 - November 24, 2005 DATES OF ISSUE: November 24, 2005 TEST LABORATORY: ETL Inc. (FCC Registration Number: 95422) #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea Tel: (031) 885-0072Fax: (031)885-0074 FCC TEST REPORT E05.1124.FCC.743N / Page 2 of 16 Head Office : # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea /Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab :#584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel : 82-31-885-0072, Fax : 82-31-885-0074 Form No.: ETL(E)004A4001201-0 Table of Contents FCC Measurement Report 1. Introduction 2. Product Information 3. Description of Tests 4. Test Condition 5. Test Results 5.1Summary of Test Results 5.2Conducted Emissions Measurement 5.3 Radiated Emissions Measurement 6. Sample Calculation 7. List of test Equipment used for Measurement Appendix A. FCC ID Label and Location Appendix B.Test Setup Photographs Appendix C. External Photographs Appendix D. Internal Photographs Appendix E. Block Diagram Appendix F. Userโ€™s Manual FCC TEST REPORT E05.1124.FCC.743N / Page 3 of 16 Head Office : # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea /Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab :#584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel : 82-31-885-0072, Fax : 82-31-885-0074 Form No.: ETL(E)004A4001201-0 Scopeโ€“ Measurement and determination of electromagnetic emission(EME) of radio frequency devices including intentional radiators and/or unintentional radiators for compliance with the technical rules and regulations of the U.S Federal Communications Commission(FCC) General Information zEUT Type: PLC Modem zModel Number: MM-202BX zFCC ID: PQVMM-202BX zS/N: N/A zFCC Rule Part(s): FCC Part 15 Subpart B zTest Procedure: ANSI C63.4- 2001 zFCC Classification: Class B personal computers and peripherals zDates of Tests: November 07 โ€“November 24, 2005 zPlace of Tests: ETL Inc. EMC Testing Lab. (FCC Registration Number: 95422) 584, Sangwhal-Ri, Kanam-Myun, Yo ju-Kun, Kyounggi-Do, Korea Tel: (031) 885-0072Fax: (031)885-0074 zTestReport No.: E05.1124.FCC.743N Applicant Name : Xeline Co., Ltd. Address : 5F Seowon Bldg., 1515-4 Seocho3-dong, Seocho-gu, Seoul, 137-871, Korea Attention : IL-Soo, Kim / Senior Manager FCC TEST REPORT E05.1124.FCC.743N / Page 4 of 16 Head Office : # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea /Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab :#584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel : 82-31-885-0072, Fax : 82-31-885-0074 Form No.: ETL(E)004A4001201-0  G อ‘ The measurement test for radiated and conducted emission test were conducted at the open area test site of E-RAE Testing Laboratory Inc. facility located at 584, Sangwhal-ri, Kanam-myun, Youju-kun, Kyounggi-do, Korea. The site is constructed in conformance with the requirements of the ANSI C63.4-2001 and CISPR Publication 16. The ETL has site descriptions on file with the FCC for 3 and 10meter site configurations. Detailed description of test facility was found to be in compliance with the requirements of Section 2.948 FCC Rules according to the ANSI C63.4-2001 and registered to the Federal Communications Commission (Registration Number: 95422). The measurement procedure described in American National Standard for Method of Measurement of Radio-Noise Emission from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz (ANSI C.63.4-2001) was used in determining radiated and conducted emissions from the Xeline Co., Ltd., Model: MM-202BX. FCC TEST REPORT E05.1124.FCC.743N / Page 5 of 16 Head Office : # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea /Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab :#584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel : 82-31-885-0072, Fax : 82-31-885-0074 Form No.: ETL(E)004A4001201-0   G อ‘ 2.1 General Remarks 2.2 Equipment Description The Equipment Under Test (EUT) is the Xeline Co., Ltd., PLC Modem, MM-202BX 2.3 General Specification SpecificationsRemarks Data rates Up to 24Mbps Fundamental Carrier 24 MHz RJ-45 Ethernet 2 portFor connection with backbone RJ-45 UART 1 portOptional use Interface RJ-11 PLC 2 portFor connection with CU-100A PowerAC 110V - 240V, 0.5A,50/60Hz Dimensions260mmร— 154mโ€ฆ

Text truncated - open the document above for the full version.

Test Setup Photos

Appendix B. Test Setup Photographs E05.1124.FCC.743N / Page B1 of B3 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab: #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel:82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 Conducted Emission Test Setup Appendix B. Test Setup Photographs E05.1124.FCC.743N / Page B2 of B3 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab: #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel:82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 Radiated Emission Test Setup(30 MHz to 1000 MHz) Appendix B. Test Setup Photographs E05.1124.FCC.743N / Page B3 of B3 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab: #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel:82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 Radiated Emission Test Setup(9 kHz to 30 MHz)

Contact Information

Applicant

Il-Soo Kim(Senior Manager)
[email protected]+82-2-598-0980Fax: +82-2-598-0975

Test Firm

E-RAE Testing LaboratoryYo Han Park
[email protected]82-31-885-0072Fax: 82-31-885-0074

Technical Specifications

#Rule PartsFrequency RangePower Output
115B--

Other Applications from Xeline Co., LTd.

EMS agent - FCC ID PQVEU-200BX - Xeline Co., LTd.
PQVEU-200BX

EMS agent

Feb 02, 2006

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
PLC(PowerLine Communication) Modem - FCC ID PQVSU-200BX - Xeline Co., LTd.
PQVSU-200BX

PLC(PowerLine Communication) Modem

Jul 07, 2005

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
PLC (PowerLine Communication) Modem - FCC ID PQVSU-200B - Xeline Co., LTd.
PQVSU-200B

PLC (PowerLine Communication) Modem

Feb 07, 2005

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
Powerline Home LAN - FCC ID PQVXUP - Xeline Co., LTd.
PQVXUP

Powerline Home LAN

Jun 24, 2001

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral