SU-200B Installation Manual (For Technicians Only) PLC Slave Unit Plug into the future Powerline Communication by Xeline Xeline Co., Ltd. SU-200B Installation Manual This document is subject to change without prior notice. 2 ATTENTION This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ย Reorient or relocate the receiving antenna. ย Increase the separation between the equipment and receiver. ย Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ย Consult the dealer or an experienced radio/TV technician for help. Change or modification not expressly approved by the party responsible for Compliance could void the userโs authority to operate the equipment. This equipment conforms with the following standard(s): EN60950 SU-200B Installation Manual This document is subject to change without prior notice. 3 Table of Contents 1. Introductionยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 5 2. Before Installing the SU-200Bยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 6 2.1 Package Contentsยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 6 2.2 Prerequisitesยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 6 2.3 Safety Precautionsยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 7 3. Getting to Know the SU-200Bยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 8 3.1 Front Viewยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 8 3.2 Rear Viewยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 8 3.3 Product Specificationsยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 9 3.4 Minimal Requirements for the Subscriberโs PCยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 9 4. Installing the SU-200Bยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 10 4.1 Connecting the SU-200B to the Subscriberโs PCยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 10 4.2 Configuring the Subscriberโs PCยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 12 4.3 Final Check (Ping Test)ยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 15 4.4 Resetting to Factory Default Modeยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 17 5. Trouble Shootingยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 18 6. Appendixยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยทยท 19 SU-200B Installation Manual This document is subject to change without prior notice. 4 Figure Index Figure 1 XPAS-200B PLC Internet Access System Configuration...................................5 Figure 2 SU-200B Package Contents..........................................................................6 Figure 3 SU-200B Front View.....................................................................................8 Figure 4 SU-200B Rear View......................................................................................8 Figure 5 Connecting the RJ-45 cable and SU-200B...................................................10 Figure 6 Connecting the Power Cable......................................................................10 Figure 7 Connecting the SU-200B to the Subscriberโs PC..........................................11 Figure 8 Network and Dial-up Connections..............................................................12 Figure 9 Local Area Connection Properties..............................................................12 Figure 10 Internet Protocol (TCP/IP).......................................................................13 Figure 11 Fixed IP Address Setting...........................................................................13 Figure 12 Show Icon in TaskBar...............................................................................14 Figure 13 Network Configuration Complete.............................................................14 Figure 14 Command Prompt Window.......................................................................15 Figure 15 Checking the Configured IP Address.........................................................15 Figure 16 Pinging the Default Gateway IP................................................................16 Figure 17 Checking the Ping Results........................................................................17 SU-200B Installation Manual This document is subject to change without prior notice. 5 1. Introduction Powerline Communication (PLC) technology uses the existing powerline infrastructure to transfer high-speed data, eliminating the need for expensive and complicated cablโฆ
Text truncated - open the document above for the full version.
Mixed Signal Front End Analog Front End, Filter, OP Amp PLC PHY, PLC MAC Ethernet switch controller DC 12V, 3.3V SIGNAL LINE 100MHz 25MHz
Appendix C. External Photographs E05.0127.FCC.083N / Page C1 of C1 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab: #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel:82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 Front View of EUT Rear View of EUT
Appendix A. FCC ID Label and Location E05.0127.FCC.083N / Page A1 of A1 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab: #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel: 82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 Product label sample with FCC label information Following is a sample copy of the label that will be placed on the rear cabinet of the product. The FCC ID label and compliance statement are marked in the product label. Label Location The label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time purchase.(Labeling requirements per 2.925) Xeline Co., Ltd. PLC(PowerLine Communication) Modem FCC ID : PQVSU-200B Model No : SU-200B Power : 90 Vac - 240 Vac, 50/60Hz 0.15 A Serial No : N/A This device complies with Part 15 of the FCC Rules. Operation is Subject to the following two conditions: (1) this device may not Cause harmful interference, and(2) this device must accept any Interference received, including interference that may cause undesired Operation. Made in Korea Label here
Appendix D. Internal Photographs E05.0127.FCC.083N / Page D1 of D7 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab: #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel:82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 View of Inside Appendix D. Internal Photographs E05.0127.FCC.083N / Page D2 of D7 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab: #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel:82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 Component side view of Main board Appendix D. Internal Photographs E05.0127.FCC.083N / Page D3 of D7 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab: #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel:82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 Solder side view of Main board Appendix D. Internal Photographs E05.0127.FCC.083N / Page D4 of D7 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab: #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel:82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 Solder side view of Main board(Cover open) Appendix D. Internal Photographs E05.0127.FCC.083N / Page D5 of D7 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab: #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel:82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 Component side view of power Appendix D. Internal Photographs E05.0127.FCC.083N / Page D6 of D7 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab: #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel:82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 Solder side view of power Appendix D. Internal Photographs E05.0127.FCC.083N / Page D7 of D7 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab: #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel:82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 Top main cover Bottom main cover
FCC TEST REPORT E05.0127.FCC.083N / Page 5 of 20 Head Office : # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea /Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab : #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel : 82-31-885-0072, Fax : 82-31-885-0074 Form No.: ETL(E)008A4031001-0 2.1 General Remarks 2.2 Equipment Description The Equipment Under Test (EUT) is the Xeline Co., Ltd. PLC(PowerLine Communication) Modem, SU-200B 2.3 General Specification
www.etl.re.kr E-RAE Testing Laboratory The test result only responds to the tested sample. It is not allowed to copy this report even partly without the allowance of the test laboratory. Form NO: ETL(E)004A4001201-0. Electromagnetic Emission FCC MEASUREMENT REPORT CERTIFICATION OF COMPLIANCE FCC Part 15 Certification Measurement This is PLC(PowerLine Communicarion) Modem, Model:SU-200B has been tested in accordance with the measurement procedures specified in ANSI C63.4-2001 at the ETL/EMC Test Laboratory and has been shown to be complied with the electromagnetic radiated emission limits specified in FCC Rule Part15 Subpart B: I attest to the accuracy of data. All measurement here in was performed by me or was made under my supervision and is correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. The results of testing in this report apply to the product/system, which was tested only. Other similar equipment will not necessarily produce the same results due to production tolerance and measurement uncertainties. Yo Han, Park / Chief Engineer ETL Inc. #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea PRODUCT : PLC(PowerLine Communication) Modem MODEL/TYPE NO : SU-200B FCC ID : PQVSU-200B APPLICANT / ADDRESS : Xeline Co., Ltd. 7F Chungjin Bldg., 475-22, Bangbae2-dong, Seocho-gu, Seoul, 137-819, Korea Attn.: IL-Soo, Kim / Senior Manager FCC CLASSIFICATION : Class B personal computers and peripherals (Carrier current systems) FCC RULE PART(S) : FCC Part 15 Subpart B FCC PROCEDURE : Certification TRADE NAME : N/A TEST REPORT No. : E05.0127.FCC.083N DATES OF TEST : January 15 ~ 27, 2005 DATES OF ISSUE : January 27, 2005 TEST LABORATORY : ETL Inc. (FCC Registration Number: 95422) #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea Tel: (031) 885-0072 Fax: (031) 885-0074 FCC TEST REPORT E05.0127.FCC.083N / Page 2 of 20 Head Office : # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea /Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab : #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel : 82-31-885-0072, Fax : 82-31-885-0074 Form No.: ETL(E)008A4031001-0 Table of Contents FCC Measurement Report 1. Introduction 2. Product Information 3. Description of Tests 4. Test Condition 5. Test Results 5.1 Summary of Test Results 5.2 Conducted Emissions Measurement 5.3 Radiated Emissions Measurement 6. Sample Calculations 7. List of test Equipment used for Measurement Appendix A. FCC ID Label and Location Appendix B. Test Setup Photographs Appendix C. External Photographs Appendix D. Internal Photographs Appendix E. Block Diagram Appendix F. Userโs Manual FCC TEST REPORT E05.0127.FCC.083N / Page 3 of 20 Head Office : # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea /Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab : #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel : 82-31-885-0072, Fax : 82-31-885-0074 Form No.: ETL(E)008A4031001-0 Scope โ Measurement and determination of electromagnetic emission(EME) of radio frequency devices including intentional radiators and/or unintentional radiators for compliance with the technical rules and regulations of the U.S Federal Communications Commission(FCC) General Information l EUT Type: PLC(PowerLine Communication) Modem l Model Number: SU-200B l FCC ID: PQVSU-200B l S/N: N/A l FCC Rule Part(s): FCC Part 15 Subpart B l Test Procedure: ANSI C63.4-2001 l FCC Classification: Class B personal computers and peripherals(Carrier current systems) l Dates of Tests: January 15 ~ 27, 2005 l Place of Tests: ETL Inc. EMC Testing Lab. (FCC Registration Number: 95422) 584, Sangwhal-Ri, Kanam-Myun, Yoju-Kun, Kyounggi-Do, Korea Tel: (031) 885-0072 Fax: (031) 885-0074 l Test Report No.: E05.0127.FCC.083N Applicant Name : Xeline Co., Ltd. Address : 7F Chungin Bldg., 475-22 Bangbae2-dong, Seocho-gu, Seoul 137-819, Korea Attention : IL-Soo, Kim / Senior Manager FCC TEST REPORT E05.0127.FCC.083N / Page 4 of 20 Head Office : # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea /Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab : #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel : 82-31-885-0072, Fax : 82-31-885-0074 Form No.: ETL(E)008A4031001-0 The measurement test for radiated and conducted emission test were conducted at the open area test site of E-RAE Testing Laboratory Inc. facility located at 584, Sangwhal-ri, Kanam-myun, Youju-kun, Kyounggi-do, Korea. The site is constructed in conformance with the requirements of the ANSI C63.4-2001 and CISPR Publication 16. The ETL has site descriptions on file with the FCC for 3 and 10meter site configurations. Detailed description of test facility was found to be in compliance with the requirements of Section 2.948 FCC Rules according to the ANSI C63.4-2001 and registered to the Federal Communications Commission (Registration Number: 95422). The measurement procedure described in American National Standard for Method of Measurement of Radio-Noise Emission from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz (ANSI C.63.4-2001) was used in determining radiated and conducted emissions from the Xeline Co., Ltd., Model: SU-200B. FCC TEST REPORT E05.0127.FCC.083N / Page 5 of 20 Head Office : # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea /Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab : #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel : 82-31-885-0072, Fax : 82-31-885-0074 Form No.: ETL(E)008A4031001-0 2.1 General Remarks 2.2 Equipment Description The Equipment Under Test (EUT) is the Xeline Co., Ltd. PLC(PowerLine Communication) Modem, SU-200B 2.3 General Specification FCC TEST REPORT E05.0127.FCC.083N / Page 6 of 20 Head Office : # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea /Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab : #584 Sangwโฆ
Text truncated - open the document above for the full version.
Appendix B. Test Setup Photographs E05.0127.FCC.083N / Page B1 of B3 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab: #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel:82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 Conducted Emission Test Setup Appendix B. Test Setup Photographs E05.0127.FCC.083N / Page B2 of B3 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab: #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel:82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 Radiated Emission Test Setup(30 MHz to 1000 MHz) Appendix B. Test Setup Photographs E05.0127.FCC.083N / Page B3 of B3 Head Office: # 371-51 Kasan-Dong, Keumcheon-ku, Seoul, 153-803, Korea / Tel : 82-2-858-0786, Fax : 82-2-858-0788 EMC Lab: #584 Sangwhal-ri, Kanam-myon, Yoju-kun, Kyounggi-do, 469-885, Korea /Tel:82-31-885-0072, Fax:82-31-885-0074 Form NO: ETL(E)004A4001201-0 Radiated Emission Test Setup(9 kHz to 30 MHz)
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | - | - |

EMS agent
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
PLC Modem
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
PLC(PowerLine Communication) Modem
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
Powerline Home LAN
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral