FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Acrox Technologies Co., Ltd./
  3. PRDMU112

PRDMU112Wireless Mouse

Acrox Technologies Co., Ltd.
Wireless Mouse - FCC ID PRDMU112 - Acrox Technologies Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Nov 08, 2022
Application Purpose
Original Equipment
Date of Application
Nov 08, 2022
Equipment Note
Wireless Mouse
Frequency Range
2402.00000000 - 2480.00000000
Company
Acrox Technologies Co., Ltd.
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Regulatory Notices This document provides country- and region-specific non-wireless and wireless regulatory notices and compliance information for your product. Some of these notices may not apply to your product. 이 문서에는 국가 및 지역별 유무선 규제사항 설명과 제품의 준수 정보가 있습니다. 이러한 정보 중 일부는 귀하의 제품에 적용되지 않을 수 있습니다. Federal Communications Commission notice This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio or television technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. For questions regarding this product, write to HP Inc. 1501 Page Mill Road Palo Alto, CA 94304 email [email protected], or call HP at 650-857-1501. To identify your product, refer to the part, series, or model number located on the product. Modifications The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by HP may void the user’s authority to operate the equipment. Cables To maintain compliance with FCC Rules and Regulations, connections to this device must be made with shielded cables having metallic RFI/EMI connector hoods. Products with wireless LAN devices or HP Mobile Broadband Modules This device must not be co-located or operating in conjunction with any other antenna or transmitter. WARNING: Exposure to Radio Frequency Radiation The radiated output power of this device is below the FCC/Industry Canada radio frequency exposure limits. Nevertheless, the device should be used in such a manner that the potential for human contact is minimized during normal operation. During normal operation of devices with displays equal to or less than 30.5 cm (12 inches): To avoid the possibility of exceeding the FCC/Industry Canada radio frequency exposure limits, human proximity to the antennas should not be less than 2.5 cm (1 inch). To identify the location of the wireless antennas, refer to the user guides included with your device. During normal operation of devices with displays greater than 30.5 cm (12 inches): To avoid the possibility of exceeding the FCC/Industry Canada radio frequency exposure limits, human proximity to the antennas should not be less than 20 cm (8 inches), including when the device display is closed. To identify the location of the wireless antennas, refer to the user guides included with your device. CAUTION: When using IEEE 802.11a wireless LAN, this product is restricted to indoor use, due to its operation in the 5.15- to 5.25-GHz frequency range. FCC/Industry Canada requires this product to be used indoors for the frequency range of 5.15 GHz to 5.25 GHz to reduce the potential for harmful interference to co-channel mobile satellite systems. High-power radar is allocated as the primary user of the 5.25- to 5.35-GHz and 5.65- to 5.85-GHz bands. These radar stations can cause interference with and/or damage to this device. The antennas for this device are not replaceable. Any attempt at user access will damage your device. Aviso para o Brasil Este equipamento não tem direito à proteção contra interferência prejudicial e não pode causar interferência em sistemas devidamente autorizados. Para maiores informações, consulte o site da ANATEL – www.anatel.gov.br. Canada notices This Class B digital apparatus meets all requirements of the Canadian Interference- Causing Equipment Regulations CAN ICES-3(B)/NMB-3(B). If this device has WLAN or Bluetooth® capability, the device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Avis Canadien Ce dispositif numérique de Classe B répond aux exigences de la réglementation du Canada relative aux équipements causant des interférences CAN ICES-3(B)/ NMB-3(B). Si ce dispositif est doté de fonctionnalités de réseau sans fil ou Bluetooth, il est conforme aux normes d’exemption de licence RSS d’Industrie Canada. Son fonctionnement est assujetti aux deux conditions suivantes : 1) Ce dispositif ne doit causer aucune interférence dangereuse, et 2) ce dispositif doit accepter toute interférence reçue, y compris les interférences pouvant provoquer un fonctionnement indésirable. Radiation Exposure Statement This product complies with the US/Canada portable RF exposure limit set forth for an uncontrolled environment and is safe for intended operation as described in this manual. The further RF exposure reduction can be achieved if the product can be kept as far as possible from the user’s body or set the device to lower output power if such function is available. Déclaration d’exposition aux radiations Le produit est conforme aux limites d’exposition pour les appareils portables RF …

Text truncated - open the document above for the full version.

Users Manual

GREEK Light Status Description Solid white (5 s) The mouse is on. Slowly blinking amber The battery needs to be replaced. Slowly blinking white (180 s)The mouse is in pairing mode. Quickly blinking white (2 s)The mouse is paired. FRENCH Light Status Description Solid white (5 s) The mouse is on. Slowly blinking amber The battery needs to be replaced. Slowly blinking white (180 s)The mouse is in pairing mode. Quickly blinking white (2 s)The mouse is paired. CROATIAN Light Status Description Solid white (5 s) The mouse is on. Slowly blinking amber The battery needs to be replaced. Slowly blinking white (180 s)The mouse is in pairing mode. Quickly blinking white (2 s)The mouse is paired. ITALIAN Light Status Description Solid white (5 s) The mouse is on. Slowly blinking amber The battery needs to be replaced. Slowly blinking white (180 s)The mouse is in pairing mode. Quickly blinking white (2 s)The mouse is paired. KAZAKH Light Status Description Solid white (5 s) The mouse is on. Slowly blinking amber The battery needs to be replaced. Slowly blinking white (180 s)The mouse is in pairing mode. Quickly blinking white (2 s)The mouse is paired. LATVIAN Light Status Description Solid white (5 s) The mouse is on. Slowly blinking amber The battery needs to be replaced. Slowly blinking white (180 s)The mouse is in pairing mode. Quickly blinking white (2 s)The mouse is paired. LITHUANIAN Light Status Description Solid white (5 s) The mouse is on. Slowly blinking amber The battery needs to be replaced. Slowly blinking white (180 s)The mouse is in pairing mode. Quickly blinking white (2 s)The mouse is paired. ENGLISH Light Status Description Solid white (5 s) The mouse is on. Slowly blinking amber The battery needs to be replaced. Slowly blinking white (180 s)The mouse is in pairing mode. Quickly blinking white (2 s)The mouse is paired. ARABIC Light Status Description Solid white (5 s) The mouse is on. Slowly blinking amber The battery needs to be replaced. Slowly blinking white (180 s)The mouse is in pairing mode. Quickly blinking white (2 s)The mouse is paired. BULGARIAN Light Status Description Solid white (5 s) The mouse is on. Slowly blinking amber The battery needs to be replaced. Slowly blinking white (180 s)The mouse is in pairing mode. Quickly blinking white (2 s)The mouse is paired. CZECH Light Status Description Solid white (5 s) The mouse is on. Slowly blinking amber The battery needs to be replaced. Slowly blinking white (180 s)The mouse is in pairing mode. Quickly blinking white (2 s)The mouse is paired. DANISH Light Status Description Solid white (5 s) The mouse is on. Slowly blinking amber The battery needs to be replaced. Slowly blinking white (180 s)The mouse is in pairing mode. Quickly blinking white (2 s)The mouse is paired. GERMAN Light Status Description Solid white (5 s) The mouse is on. Slowly blinking amber The battery needs to be replaced. Slowly blinking white (180 s)The mouse is in pairing mode. Quickly blinking white (2 s)The mouse is paired. INTERNATIONAL SPANISH Light Status Description Solid white (5 s) The mouse is on. Slowly blinking amber The battery needs to be replaced. Slowly blinking white (180 s)The mouse is in pairing mode. Quickly blinking white (2 s)The mouse is paired. OR On On 1 2 1 2 3s *N31684-A21* N31684-A21 PRINTER: Replace this box with Printed- In (PI) Statement(s) as per spec. NOTE: This box is simply a placeholder. PI Statement(s) do not have to fit inside the box but should be placed in this area. 3 1 2 Color Side 1: BLACK Flat size: 11 x 17 in. (279.4 x 431.8 mm) Fold 1: 3-panel Accordion Fold 2: 6-panel Accordion Color Side 2: BLACK Finished size: 3.66 x 2.833 in (92.964 x 71.9582 mm) NB_OPT_QSP_Gadget_Dual_Con_N31684-A21_v2.indd 110/5/2022 1:20:13 PM HUNGARIAN Light Status Description Solid white (5 s) The mouse is on. Slowly blinking amber The battery needs to be replaced. Slowly blinking white (180 s)The mouse is in pairing mode. Quickly blinking white (2 s)The mouse is paired. DUTCH Light Status Description Solid white (5 s) The mouse is on. Slowly blinking amber The battery needs to be replaced. Slowly blinking white (180 s)The mouse is in pairing mode. Quickly blinking white (2 s)The mouse is paired. NORWEGIAN Light Status Description Solid white (5 s) The mouse is on. Slowly blinking amber The battery needs to be replaced. Slowly blinking white (180 s)The mouse is in pairing mode. Quickly blinking white (2 s)The mouse is paired. POLISH Light Status Description Solid white (5 s) The mouse is on. Slowly blinking amber The battery needs to be replaced. Slowly blinking white (180 s)The mouse is in pairing mode. Quickly blinking white (2 s)The mouse is paired. PORTUGUESE Light Status Description Solid white (5 s) The mouse is on. Slowly blinking amber The battery needs to be replaced. Slowly blinking white (180 s)The mouse is in pairing mode. Quickly blinking white (2 s)The mouse is paired. ROMANIAN Light Status Description Solid white (5 s) The mouse is on. Slowly blinking amber The battery needs to be replaced. Slowly blinking white (180 s)The mouse is in pairing mode. Quickly blinking white (2 s)The mouse is paired. RUSSIAN Light Status Description Solid white (5 s) The mouse is on. Slowly blinking amber The battery needs to be replaced. Slowly blinking white (180 s)The mouse is in pairing mode. Quickly blinking white (2 s)The mouse is paired. SLOVAK Light Status Description Solid white (5 s) The mouse is on. Slowly blinking amber The battery needs to be replaced. Slowly blinking white (180 s)The mouse is in pairing mode. Quickly blinking white (2 s)The mouse is paired. SLOVENIAN Light Status Description Solid white (5 s) The mouse is on. Slowly blinking amber The battery needs to be replaced. Slowly blinking white (180 s)The mouse is in pairing mode. Quickly blinking white (2 s)The mouse is paired. FINNISH Light Status Description Solid white (5 s) The mouse is on. Slowly blinking amber The battery needs to be replaced. Slowly blinking whi…

Text truncated - open the document above for the full version.

Cover Letter(s)

Acrox Technologies Co., Ltd. Date: 2022-10-02 FCC ID:PRDMU112 A U T H O R I Z A T I O N L E T T E R To Whom It May Concern: Acrox Technologies Co., Ltd hereby authorizes Andrea Hsia / Supervisor of Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch (“BV CPS Taoyuan”), to act on its behalf in all matters relating to the Federal Communication Commission (“FCC”) application for equipment authorization in connection with the FCC ID listed above, including signing of all documents relating to these matters. Any and all acts carried out by Andrea Hsia / Supervisor of BV CPS Taoyuan on Acrox Technologies Co., Ltd’s behalf, within the scope of the powers granted herein, shall have the same effect as acts of its own. If you have any questions regarding the authorization, please don’t hesitate to contact us. Sincerely yours,

External Photos

Reference No.:BDYV-WTW-P22090562_ExtPho Page 1/3 CONSTRUCTION PHOTOS OF EUT Reference No.:BDYV-WTW-P22090562_ExtPho Page 2/3 Reference No.:BDYV-WTW-P22090562_ExtPho Page 3/3

Internal Photos

Reference No.:BDYV-WTW-P22090562_IntPho Page 1/4 CONSTRUCTION PHOTOS OF EUT Reference No.:BDYV-WTW-P22090562_IntPho Page 2/4 Reference No.:BDYV-WTW-P22090562_IntPho Page 3/4 Reference No.:BDYV-WTW-P22090562_IntPho Page 4/4 Antenna

RF Exposure Info

Report No.: MFBDYV-WTW-P22090562 Page No. 1 / 8 Report Format Version: 7.1.0 Reference No.: BDYV-WTW-P22090562 RF EXPOSURE REPORT CERTIFICATE OF CONFORMITY FCC Rule Part: FCC Part 2 (Section 2.1093) Report No.: MFBDYV-WTW-P22090562 FCC ID: PRDMU112 Product: Wireless Mouse Brand: hp Model No.: TPA-A003M Received Date: 2022/9/16 Test Date: 2022/10/5 Issued Date: 2022/10/21 Applicant: Acrox Technologies Co., Ltd Address: 4F., No. 89, Minshan St., Neihu Dist., Taipei City 114, Taiwan, R.O.C. Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Lin Kou Laboratories Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan Test Location: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan FCC Registration / Designation Number: 198487 / TW2021 Approved by: , Date: 2022/10/21 Jeremy Lin / Project Engineer This test report consists of 8 pages in total. It may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced except in full, without the written approval of our laboratory. The test results in the report only apply to the tested sample. The test results in this report are traceable to the national or international standards. Prepared by : Annie Chang / Senior Specialist This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our- business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Report No.: MFBDYV-WTW-P22090562 Page No. 2 / 8 Report Format Version: 7.1.0 Reference No.: BDYV-WTW-P22090562 Table of Contents Release Control Record ....................................................................................................................................................... 3 1 Certificate .................................................................................................................................................................... 4 2 Applicable RF Exposure Limit .................................................................................................................................. 5 3 Applicable Evaluation Criteria .................................................................................................................................. 6 4 Test Results ................................................................................................................................................................ 7 4.1 RF Exposure ............................................................................................................................................................. 7 5 Conclusion .................................................................................................................................................................. 7 6 Information of the Testing Laboratories .................................................................................................................. 8 Report No.: MFBDYV-WTW-P22090562 Page No. 3 / 8 Report Format Version: 7.1.0 Reference No.: BDYV-WTW-P22090562 Release Control Record Issue No. Description Date Issued MFBDYV-WTW-P22090562 Original release. 2022/10/21 Report No.: MFBDYV-WTW-P22090562 Page No. 4 / 8 Report Format Version: 7.1.0 Reference No.: BDYV-WTW-P22090562 1 Certificate Product: Wireless Mouse Brand: hp Test Model: TPA-A003M Sample Status: Engineering sample Applicant: Acrox Technologies Co., Ltd Test Date: 2022/10/5 FCC Rule Part: FCC Part 2 (Section 2.1093) Standard: KDB 447498 D04 Interim General RF Exposure Guidance v01 The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s RF characteristics under the conditions specified in this report. Report No.: MFBDYV-WTW-P22090562 Page No. 5 / 8 Report Format Version: 7.1.0 Reference No.: BDYV-WTW-P22090562 2 Applicable RF Exposure Limit § 1.1310 Radiofrequency radiation exposure limits. (a) Specific absorption rate (SAR) shall be used to evaluate the environmental impact of human exposure to radiofrequency (RF) radiation as specified in § 1.1307(b) of this part within the frequency range of 100 kHz to 6 GHz (inclusive). (b) The SAR limits for occupational/controlled exposure are 0.4 W/kg, as averaged over the whole body, and a peak spatialaverage SAR of …

Text truncated - open the document above for the full version.

Test Report

Antenna Report APPLICANT : Acrox Technologies Co., Ltd ANTENNA TYPE : PCB Antenna MODEL NAME : Ant-B2A TRADE NAME : N/A BRAND NAME : N/A STANDARD(S) : IEEE Std 149-2021 RECEIPT DATE : 2022-10-04 TEST DATE : 2022-10-07 ISSUE DATE : 2022-10-08 Manufacturer : Acrox Technologies Co., Ltd Edited by:Fang Ji nshan(Rapporteur) Approved by:Chi Shide(Supervisor) 2400 MHz 2450 MHz 2500 MHz 2402MHz 2480MHz 2402 2480 2408 2474MHz 2408 2474 Horizontal: 2402MHz 2440MHz 2480MHz hp TPA-A003M FCC ID: PRDMU112 30 IC: 6180A-B2A BT & SRD: 2402~2480MHz 0 330 60 300 90 270 120 240 Max: 0 Min : -40 Scale: 5 /d iv 150 180 Angle (? 210 2402 -1.66179 -30.2813 -8.78713 2440 -0.847811 -38.7595 -7.87812 2480 -0.615596 -23.6329 -6.99139 2400 MHz 2450 MHz 2500 MHz 2480MHz 2402MHz 2402 2480 2408 2474MHz 2474 2408 Vertical: 2402MHz 2440MHz 2480MHz 0 30 330 60 300 90 270 120 240 Max: 0 Min : -30 Scale: 5 /d iv 150 180 Angle (? 210 2402 -6.1623 -23.1425 -12.5295 2440 -3.6534 -26.2866 -10.6699 2480 -2.21101 -29.4381 -9.58526 Test Equipment’s Utilized No. Equipement Name Serial No. Type Manufa cturer Cal.Date Cal.Due Date 1 Network Analyzer MY46110140 E5071C Agilent 2022.07.04 2023.07.03 2 OTA Chamber TJ2235-Q17 93 AMS-8923-1 50 ETS 2020.01.06 2023.01.05 3 Antenna Measurement System 1685 EMQuest EMQ- 100 V 1.13 Build 21267 ETS N/A N/A Test Setup Test Diagram Antenna Chamber Initial Setting 1.Place the DUT in Antenna Chamber 2.Implement the test program Measured the antenna efficiency and 2D radiation Pattern.

Test Report

Report No.: RFBDYV-WTW-P22090562 Page No. 1 / 31 Report Format Version: 7.1.0 Reference No.: BDYV-WTW-P22090562 TEST REPORT CERTIFICATE OF CONFORMITY Standard: 47 CFR FCC Part 15, Subpart C (Section 15.247) Report No.: RFBDYV-WTW-P22090562 FCC ID: PRDMU112 Product: Wireless Mouse Brand: hp Model No.: TPA-A003M Received Date: 2022/9/16 Test Date: 2022/9/21 ~ 2022/10/5 Issued Date: 2022/10/21 Applicant: Acrox Technologies Co., Ltd Address: 4F., No. 89, Minshan St., Neihu Dist., Taipei City 114, Taiwan, R.O.C. Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Lin Kou Laboratories Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan Test Location: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan FCC Registration / Designation Number: 198487 / TW2021 Approved by: , Date: 2022/10/21 Jeremy Lin / Project Engineer This test report consists of 31 pages in total. It may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced except in full, without the written approval of our laboratory. The test results in the report only apply to the tested sample. The test results in this report are traceable to the national or international standards. Prepared by : Annie Chang / Senior Specialist This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our- business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Report No.: RFBDYV-WTW-P22090562 Page No. 2 / 31 Report Format Version: 7.1.0 Reference No.: BDYV-WTW-P22090562 Table of Contents Release Control Record ....................................................................................................................................................... 4 1 Certificate .................................................................................................................................................................... 5 2 Summary of Test Results .......................................................................................................................................... 6 2.1 Measurement Uncertainty ........................................................................................................................................ 6 2.2 Supplementary Information ...................................................................................................................................... 6 3 General Information ................................................................................................................................................... 7 3.1 General Description .................................................................................................................................................. 7 3.2 Antenna Description of EUT ..................................................................................................................................... 7 3.3 Channel List .............................................................................................................................................................. 8 3.4 Test Mode Applicability and Tested Channel Detail .................................................................................................. 9 3.5 Duty Cycle of Test Signal.......................................................................................................................................... 9 3.6 Test Program Used and Operation Descriptions .................................................................................................... 10 3.7 Connection Diagram of EUT and Peripheral Devices ............................................................................................ 10 3.8 Configuration of Peripheral Devices and Cable Connections ................................................................................ 10 4 Test Instruments ...................................................................................................................................................... 11 4.1 RF Output Power .................................................................................................................................................... 11 4.2 Power Spectral Density .......................................................................................................................................... 11 4.3 6 dB Bandwidth ............................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Reference No.:RFBDYV-WTW-P22090562 Page 1/2 PHOTOGRAPHS OF THE TEST CONFIGURATION Unwanted Emissions below 1 GHz Reference No.:RFBDYV-WTW-P22090562 Page 2/2 Unwanted Emissions above 1 GHz

Contact Information

Applicant

Gavin Hsieh(Product Manager)
[email protected]886-2-2796-5888Fax: 886-2-2793-8999

Test Firm

Bureau Veritas CPS(H.K.) Ltd., Taoyuan BranchLiu Ken
[email protected]+886-3-2600609Fax: +886-3-2115834

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz3.00 mW
Confidentiality
Long Term
Grant Notes
Power listed is maximum conducted output power.

Other Applications from Acrox Technologies Co., Ltd.

Wireless Receiver - FCC ID PRDRX12 - Acrox Technologies Co., Ltd.
PRDRX12

Wireless Receiver

May 27, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Wireless Receiver - FCC ID PRDRX11 - Acrox Technologies Co., Ltd.
PRDRX11

Wireless Receiver

Apr 07, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
WIRELESS SPLIT KEY ERGONOMIC KEYBOARD - FCC ID PRDKB72 - Acrox Technologies Co., Ltd.
PRDKB72

WIRELESS SPLIT KEY ERGONOMIC KEYBOARD

Apr 03, 2026

Equipment Class

DTS - Digital Transmission System
Wireless Receiver - FCC ID PRDRX1P - Acrox Technologies Co., Ltd.
PRDRX1P

Wireless Receiver

Apr 03, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Gaming Keyboard - FCC ID PRDKB73 - Acrox Technologies Co., Ltd.
PRDKB73

Gaming Keyboard

Apr 03, 2026

Equipment Class

DTS - Digital Transmission System