Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
27M RF Optical Mouse OWNER'S GUIDE Model Name:MPQ Ver.:1.00 1 CAUTION: To use this mouse properly, please read the user's guide before installation Mouse Buttons 1. Left button 2. Right button 3 : 800 DPI Installation Mouse: 1. Plug the RF receiver into the USB port of your computer. 2. Put the batteries into the mouse and switch it on. 3. Press the reset button on the receiver and then press the reset button on the mouse. 4. When the pairing completed, the mouse is ready to use. Tilt Wheel Driver: 1. Insert the installation CD into your CD-ROM. 2. The installation program will launch automatically. 3. Click on “Next” to begin the installation. 4. Select the type of mouse to continue the installation. 5. The default installation folder is “C: Program File\Tilt Mouse Software\1.0”. If you would like to select a different installation directory, click on “Browse”. Then click on “Next” to continue. 6. The “Start menu” folder for the mouse has the default name of “tech”. If you would like to change to a new folder, click on “Browse” to select a new folder. Click on “Next” to continue. 7. “Ready to install” dialogue appears. Click on “Install” to continue. 8. When installation completed, a “Completing Installation” dialogue box will appear, click on “Finish” to exit the installation wizard. 2 Mouse Buttons Program Software Instruction After the driver installed, a “mouse” icon will appear on the task bar. Double click on it will launch the mouse settings program. There are two categories in the mouse settings program: Wheel and Button. Users are able to change the buttons settings and scroll wheel settings. Wheel Settings z By changing the scrolling setting, users can adjust the number of lines that will scroll at a time. Choosing “One screen at a time” will scroll down one page. z In the Horizontal Scrolling, users can input the number of characters to select when using the tilt the wheel. z Click “Apply” to activate the new settings and click on “OK” to close the dialogue box. Buttons Setting For 3 button mouse, users can only program the function of the scroll 3 wheel. Use the drop down menu to change the settings. For mice with 5 or more buttons, users can program the scroll wheel, the 4 th button, and the 5 th button. z The item 3 setting programs the function of the scroll wheel. Use the drop down menu to change the settings. z The item 4 setting programs the 4 th button on the side of the mouse. Use the drop down menu to change the settings. z The item 5 setting programs the 5 th button on the side of the mouse. Use the drop down menu to change the settings. 4 Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: 5 - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Page 1 CONSTRUCTION PHOTOS OF EUT
27M RF Optical Mouse Model name: MPQ FCC ID : PRDRFBGMU0001 Label size: 20X15mm
FCC ID .: PRDRFBGMU0001 Label Location
Page 2 Page 3 Page 4 Page 5
FCC ID: PRDRFBGMU0001 Report No.: RF961213L10 Operational Description The transmitter of the EUT (27M RF Optical Mouse) is powered from 2.4Vdc batteries. The antenna is printed antenna without antenna connector. For more detailed instruction, please take a look at the user’s manual.
Report No.: RF961213L10 1 Report Format Version 2.0.6 FCC TEST REPORT REPORT NO.: RF961213L10 MODEL NO.: MPQ (Refer to item 3.1 for the more details) RECEIVED: Dec. 14, 2007 TESTED: Dec. 14 ~ Dec. 19, 2007 ISSUED: Dec. 21, 2007 APPLICANT: Acrox Technologies Co., Ltd ADDRESS: 8F, No. 437, Rui Guang RD., Nei Hu Dist., Taipei 114, Taiwan, R.O.C. ISSUED BY: Advance Data Technology Corporation LAB ADDRESS: No. 47, 14 th Ling, Chia Pau Tsuen, Lin Kou Hsiang 244, Taipei Hsien, Taiwan, R.O.C. TEST LOCATION: No. 19, Hwa Ya 2 nd Rd., Wen Hwa Tsuen, Kwei Shan Hsiang, Taoyuan Hsien 333, Taiwan, R.O.C. This test report consists of 16 pages in total. It may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced except in full, without the written approval of our laboratory. The client should not use it to claim product endorsement by TAF, A2LA or any government agencies. The test results in the report only apply to the tested sample. Report No.: RF961213L10 2 Report Format Version 2.0.6 Table of Contents 1 CERTIFICATION..............................................................................................3 2 SUMMARY OF TEST RESULTS .....................................................................4 2.1 MEASUREMENT UNCERTAINTY...................................................................4 3 GENERAL INFORMATION ..............................................................................5 3.1 GENERAL DESCRIPTION OF EUT ................................................................5 3.1 DESCRIPTION OF TEST MODES ..................................................................6 3.1.1 CONFIGURATION OF SYSTEM UNDER TEST.............................................6 3.1.2 TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL...................6 3.2 GENERAL DESCRIPTION OF APPLIED STANDARDS..................................7 3.3 DESCRIPTION OF SUPPORT UNITS ............................................................7 4 TEST PROCEDURE AND RESULT.................................................................8 4.1 RADIATED EMISSION MEASUREMENT........................................................8 4.1.1 LIMITS OF RADIATED EMISSION MEASUREMENT .....................................8 4.1.2 TEST INSTRUMENT .......................................................................................9 4.1.3 TEST PROCEDURE......................................................................................10 4.1.4 TEST SETUP................................................................................................. 11 4.1.5 EUT OPERATING CONDITION..................................................................... 11 4.1.6 TEST RESULTS ............................................................................................12 5 PHOTOGRAPHS OF THE TEST CONFIGURATION....................................14 6 INFORMATION ON THE TESTING LABORATORIES...................................15 7 APPENDIX-A .................................................................................................16 Report No.: RF961213L10 3 Report Format Version 2.0.6 1 CERTIFICATION PRODUCT: 27M RF Optical Mouse MODEL: MPQ (Refer to item 3.1 for the more details) BRAND: ACROX APPLICANT: Acrox Technologies Co., Ltd TESTED: Dec. 14 ~ Dec. 19, 2007 TEST SAMPLE: ENGINEERING SAMPLE STANDARDS: FCC Part 15, Subpart C (Section 15.227), ANSI C63.4-2003 The above equipment (model: MPQ) has been tested by Advance Data Technology Corporation, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s EMC characteristics under the conditions specified in this report. PREPARED BY : , DATE:Dec. 21, 2007 Peggy Chen / Specialist TECHNICAL ACCEPTANCE : , DATE:Dec. 21, 2007 Responsible for RF Long Chen / Senior Engineer APPROVED BY : , DATE:Dec. 21, 2007 Gary Chang / Assistant Manager Report No.: RF961213L10 4 Report Format Version 2.0.6 2 SUMMARY OF TEST RESULTS The EUT has been tested according to the following specifications: APPLIED STANDARD: FCC Part 15, Subpart C STANDARD PARAGRAPH TEST TYPE RESULT REMARK 15.207 AC Power Conducted Emission NA Power supply is 2.4Vdc from batteries. 15.227 15.209 Radiated Emission Test PASS Meet the requirement of limit. Minimum passing margin is –17.29dB at 953.44MHz. 2.1 MEASUREMENT UNCERTAINTY Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the EUT as specified in CISPR 16-4-2: Measurement Frequency Uncertainty Conducted emissions 9kHz~30MHz 2.44 dB 30MHz ~ 200MHz 3.34 dB Radiated emissions 200MHz ~1000MHz 3.35 dB This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2. Report No.: RF961213L10 5 Report Format Version 2.0.6 3 GENERAL INFORMATION 3.1 GENERAL DESCRIPTION OF EUT PRODUCT 27M RF Optical Mouse MODEL NO. MPQ (Refer to Note 1 for the more details) FCC ID PRDRFBGMU0001 POWER SUPPLY 2.4Vdc from battery (For transmitter) 5.0Vdc from host equipment (For receiver) MODULATION TYPE FSK CARRIER FREQUENCY OF EACH CHANNEL 27.045MHz NUMBER OF CHANNEL 1 ANTENNA TYPE Printed antenna DATA CABLE 1.5m Non-shielded USB cable (For receiver) I/O PORTS USB for receiver ACCESSORY DEVICE NA NOTE: 1. The following models are provided to this EUT. Model Name BRAND Transmitter Receiver Remark ACROX MPQ MR8 Transmitter & Receiver ACROX MPY MR3 For Marketing Difference Only - TX & RX ACROX MPN MRB For Marketing Difference Only - TX & RX ACROX MOY MRB For Marketing Difference Only - TX & RX ACROX MPO MRB For Marketing Difference Only - TX & RX ACROX MOZ MRB For Marketing Difference Only - TX & RX ACROX MPA MRE For Marketing Difference Only - TX & RX ACROX MPB MRE For Marketing Difference Only - TX & RX ACROX MPT MRF For Marketing Difference Only - TX & RX ACROX MRI MRF F…
Text truncated - open the document above for the full version.
1 PHOTOGRAPHS OF THE TEST CONFIGURATION RADIATED EMISSION TEST
No. 19, Hwa Ya 2nd Rd., Kwei Shan Hsiang · Taoyuan Hsien · Taiwan
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 27.045 MHz - 27.045 MHz | - |

Wireless Receiver
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Wireless Receiver
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
WIRELESS SPLIT KEY ERGONOMIC KEYBOARD
Equipment Class
DTS - Digital Transmission System
Wireless Receiver
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Gaming Keyboard
Equipment Class
DTS - Digital Transmission System