Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Nov 29, 2005
Application Purpose
Original Equipment
Date of Application
Nov 29, 2005
Equipment Note
Remote Control
Frequency Range
315.00000000 - 315.00000000
Company
Hörmann KG Antriebstechnik
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Fig. 1 HSM 1 2 3 1x12 Volt 23A or A23 1x12 Volt 23A or A23 HS HS SupraMatic Series Operating Instructions for hand transmitters HS / HSM 11.2005 TR20H007 RE Fig. 2 Always program the remote control inside the garage near the door operator. When putting the remote control into operation, use original components only. • Protect equipment from direct sunlight. • Protect hand transmitters against damp and dust. CAUTION! Negligence, in particular exposure to moisture, may impair functions. Temperature range: -4 °F to +140 °F Local conditions may affect the range of the remote control. Fig. 1 Hand transmitters HS and HSM O a LED O b Control buttons O c Battery compartment cover O d Battery O e Hand transmitter holder O f Visor clip Nevertheless, the hand transmitters HS / HSM operating frequencies 315 MHz shall be used in such a manner that the potential for human contact during normal operation is minimized. IC: before the equipment certification number signifies that the Industry Canada technicalspecifications were met. It does not guarantee that the certified product will ope- rate to the user’s satisfaction. WARNING Keep hand transmit- ters well out of the reach of children. Hand transmitters should only be used by persons who know how to operate the remote-controlled door system. Only drive through or walk under a remote-controlled door if the door is stationary and in the “fully open” position. Only use the remote control when the door is within sight. USA: FCC ID: PZI-315HSHE Canada: IC: 4205A-315HSHE This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesiredoperation. CAUTION! Changes or modifications made to this equipment not expressly approved by Hörmannmay void the FCC authorization to operate this equipment. The radiated output power of hand transmitters HS / HSM with operating frequencies 315 MHz is far below the FCC radio frequency exposure limits. ENGLISH Note: Ensure correct polarity when inserting the batteries. Fig. 2 Programming the radio code Note: If the garage does not have a separate entrance, any programming or exten- sion should be carried out inside the garage. Always make sure that no persons or objects are within the door’s range of travel. 1. Briefly press the red button “P” (programming button) on the radio receiver, the red LED starts flashing slowly. 2. Press the button you wish to use on the hand transmitter for at least 1 second. The distance between the transmitter and the radio receiver should be at least 3 ft. 3. Once the programming has been completed, the red LED on the radio receiver starts flashing rapidly. 4. Release the button on the hand transmitter. Once the flashing stops, the radio receiver is ready for operation. Test the function. WARNING The activation of a hand transmitter during the learning procedure may set the door in motion. Protected by copyright. Subject to technical modifications. Any reprints, in whole or in part, are not permitted without prior written approval. All terms subject to change. 11.2005 TR20H007 RE

Cover Letter(s)

CONFIDENTIALITY REQUEST Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 November 14, 2005 TO WHOM IT MAY CONCERN Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, Company requests confidentiality for the following products: FCC ID Number Product Title/Model PZI-315HSHEHS4-315 HSM4-315 HE1-315 HE2-315 For the product stated above, we request that the following information be held confidential: 1.Circuit diagrams, BOM, and PCBs submitted as Equipment Authorization Electronic Filing attachment: "schematics”. 2. Block diagram submitted as Equipment Authorization Electronic Filing attachment: “blockdiagram”. 3. Operational description submitted as Equipment Authorization Electronic Filing attachment: “operational description” The above exhibits contain Company trade secrets and proprietary information that could be of benefit to our competitors regarding the design of our mobile handset. This material is not customarily available to the general public and we request that it be withheld from public inspection. If you have any questions, please feel free to contact me at the address shown below. Sincerely, (signed) Name: Franz Ziesché Company: Hörmann KG Antriebstechnik Address: Michaelisstr. 1, D-33803 Steinhagen, Germany Phone: +49-(0)5204-922-341 Email: +49-(0)5204-922-340

External Photos

CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 2-4168-01-01/05 Date: 2005-11-17 Page 28 of 37 6 Annex C: External Photographs of the Equipment Photo 1: HS4-315 and HSM4-315 CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 2-4168-01-01/05 Date: 2005-11-17 Page 29 of 37 Photo 2: HS4-315 and HSM4-315

Internal Photos

CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 2-4168-01-01/05 Date: 2005-11-17 Page 32 of 37 7 Annex D: INTERNAL PHOTOGRAPHS OF THE EQUIPMENT Photo 1: HS4-315 and HSM4-315 CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 2-4168-01-01/05 Date: 2005-11-17 Page 33 of 37 Photo 2: CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 2-4168-01-01/05 Date: 2005-11-17 Page 34 of 37 Photo 3:

Test Report

CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 2-4168-01-01/05 Date: 2005-11-17 Page 1 of 37 Recognized by the Federal Communications Commission Anechoic chamber registration no.: 90462 (FCC) Anechoic chamber registration no.: 3463 (IC) TCB ID: DE 0001 Accredited by the German Accreditation Council DAR–Registration Number DAT–P–176/94-D1 Independent ETSI compliance test house ETSI Accredited Bluetooth ® Test Facility (BQTF) Test report no. : 2-4168-01-01/05 Applicant : Hörmann KG Antriebstechnik Type : HS4-315 / HSM4-315 ; HE1-315 / HE2-315 Test Standard : FCC Part 15 / RSS210 FCC ID : PZI-315HSHE Certification No. IC : 4205A-315HSHE CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 2-4168-01-01/05 Date: 2005-11-17 Page 2 of 37 Table of contents 1 GENERAL INFORMATION ................................................................................................................................... 3 1.1. ADMINISTRATIVE DATA OF THE TEST FACILITY..................................................................................................... 3 1.1.1 Identification of the testing laboratory ......................................................................................................... 3 1.2. NOTES................................................................................................................................................................... 3 1.3 DETAILS OF APPLICANT......................................................................................................................................... 4 1.4 APPLICATION DETAILS.......................................................................................................................................... 4 1.5 TEST ITEM............................................................................................................................................................. 5 1.6 TEST SETUP........................................................................................................................................................... 6 1.7 TEST SPECIFICATIONS............................................................................................................................................ 6 2 STATEMENT OF COMPLIANCE .......................................................................................................................... 7 2.1 SUMMARY OF MEASUREMENT RESULTS................................................................................................................ 7 2.1.1 CFR 47 Part 15 Radio frequency devices ..................................................................................................... 7 3 MEASUREMENTS AND RESULTS ....................................................................................................................... 8 4 FCC PART 15 SUBPART C...................................................................................................................................... 9 4.1 Timing of the transmitter .................................................................................................................................. 9 4.2 Field strength of the fundamental ................................................................................................................... 11 4.3 Field strength of the harmonics and the spurious........................................................................................... 12 4.3.1 Harmonics and Spurious ............................................................................................................................ 12 4.4 Plots of measurements .................................................................................................................................... 13 4.5 Bandwidth of emission .................................................................................................................................... 15 5 FCC PART 15 SUBPART B .................................................................................................................................... 16 5.1 Receiver spurious emission (radiated)............................................................................................................ 16 5.2 Plots of measurements .................................................................................................................................... 17 5.3 Conducted Limits ............................................................................................................................................ 18 6 ANNEX B: PHOTOGRAPHS OF TEST SITE ..................................................................................................... 23 7 ANNEX C: EXTERNAL PHOTOGRAPHS OF THE EQUIPMENT ................................................................ 28 8 ANNEX D: INTERNAL PHOTOGRAPHS OF THE EQUIPMENT.................................................................. 32 CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 2-4168-01-01/05 Date: 2005-11-17 Page 3 of 37 1 General information 1.1. Administrative data of the test facility 1.1.1 Identification of the testing laboratory Company name: Cetecom ICT Services GmbH Address: Untertürkheimerstr. 6-10 D-66117 Saarbruecken Germany Laboratory accreditation: DAR-Registration No. DAT-P-176/94-D1 Bluetooth Qualification Test Facility (BQTF) Federal Communications Commission (FCC) Identification/Registration No : 90462 Responsible for testing laboratory: Michael Berg Phone: +49 681 598 0 Fax: +49 681 598 9075 email: [email protected] 1.2. Notes The test results of this test repor…

Text truncated - open the document above for the full version.

Test Setup Photos

CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 2-4168-01-01/05 Date: 2005-11-17 Page 23 of 37 5 Annex B: Photographs of Test site Photo 1 (Radiated Emissions): HS4-315 CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 2-4168-01-01/05 Date: 2005-11-17 Page 24 of 37 Photo 2 (Radiated Emissions):HS4-315 CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 2-4168-01-01/05 Date: 2005-11-17 Page 25 of 37 Photo 3 (Radiated Emissions):HE2-315 CETECOM ICT Services GmbH Untertürkheimer Str. 6-10, 66117 Saarbruecken Phone: +49 (0) 681 598-0 Fax: -9075 RSC-Laboratory Phone: +49 (0) 681 598-0 Fax: -9075 Test report no.: 2-4168-01-01/05 Date: 2005-11-17 Page 26 of 37 Photo 4 (Radiated Emissions):HE2-315

Contact Information

Applicant

Franz Ziesch(Dipl.-Ing.)
[email protected]+49 5204 922-341Fax: +49 5204 922-340

Test Firm

cetecom advanced GmbHGerald Schmidt
[email protected]49-681-598-0Fax: 49-681-598-8775

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231315 MHz - 315 MHz-
Confidentiality
Long Term

Other Applications from Hörmann KG Antriebstechnik

Remote Control Transmitter - FCC ID PZI-390FCT3B - Hörmann KG Antriebstechnik
PZI-390FCT3B

Remote Control Transmitter

Sep 06, 2004

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Remote Control Transmitter - FCC ID PZI-390FCT10 - Hörmann KG Antriebstechnik
PZI-390FCT10

Remote Control Transmitter

Apr 03, 2002

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Remote Control Transmitter - FCC ID PZI-40HSHE - Hörmann KG Antriebstechnik
PZI-40HSHE

Remote Control Transmitter

Jan 23, 2002

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Remote Control Transmitter - FCC ID PZI-390HSHE - Hörmann KG Antriebstechnik
PZI-390HSHE

Remote Control Transmitter

Jan 14, 2002

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter