FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Denso Wave Incorporated/
  3. PZWKCS

PZWKCSWLAN Adapter card

Denso Wave Incorporated
WLAN Adapter card - FCC ID PZWKCS - Denso Wave Incorporated
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jan 05, 2004
Application Purpose
Original Equipment
Date of Application
Jan 05, 2004
Equipment Note
WLAN Adapter card
Frequency Range
2412.00000000 - 2462.00000000
Company
Denso Wave Incorporated
Country
Japan

Documents & Files

Select a file to view

Users Manual

↗
↗

Cover Letter(s)

↗
↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Operator's Guide This guide has been prepared expressly for the hands-on user. Always keep it nearby for speedy reference. Related Publications BHT-7500W User’s Manual (Contained in the Manual Pack CD) Instructions for using the handy terminal (BHT-7500W) and optical com- munication unit (CU-7000). BHT-BASIC Programmer’s Manual (Contained in the BHT-BASIC Compiler CD and Manual Pack CD) Description for developing application programs of the handy terminal in BHT-BASIC. Transfer Utility Guide (that comes with Transfer Utility) Description about software that transmits data and programs between the handy terminal and computer. Ir-Transfer Utility C Guide (that comes with Ir-Transfer Utility C) Description about software that transmits data and programs between the handy terminal and computer via the optical communication unit (CU). Ir-Transfer Utility E Guide (that comes with Ir-Transfer Utility E) Description about software that transmits data and programs between the handy terminal and computer via the computer’s integrated IR port or any of the specified external IR transceivers. SAFETY PRECAUTIONS Be sure to observe all these safety precautions. Strict observance of these warning and caution indications are a MUST for preventing accidents which could result in bodily injury and substantial prop- erty damage. Make sure you fully understand all definitions of these terms and related symbols given below, before you proceed on to the text itself. Alerts you to those conditions which could cause serious bodily injury or death if the instructions are not followed correctly. WARNING CAUTION Alerts you to those conditions which could cause minor bodily injury or substantial property dam- age if the instructions are not followed correctly. Meaning of Symbols A triangle () with a picture inside alerts you to a warning of dan- ger. Here you see the warning for electrical shock. A diagonal line through a circle ( ) alerts you to something you should not do; it may or may not have a picture inside. Here you see a screwdriver inside the circle, meaning that you should not dis- assemble. A black circle ( ) with a picture inside alerts you to something you MUST do. This example shows that you MUST unplug the power cord. WARNING Handling the rechargeable battery cartridge •Never disassemble or heat the re- chargeable battery cartridge, nor put it into fire or water; doing so could cause battery-rupture or leakage of battery fluid, resulting in a fire or bodily injury. Never put me into fire! WARNING Do not short- circuit me! Charge only with the dedicated device. Undedicated •Do not carry or store the recharge- able battery cartridge together with metallic ball-point pens, necklaces, coins, hairpins, etc. Doing so could short-circuit the ter- minal pins, causing the batteries to rupture or the battery fluid to leak, resulting in a fire or bodily injury. •Avoid dropping the rechargeable battery cartridge or letting it undergo any shock or impact. Doing so could cause the batteries to break, generate heat, rup- ture or burn. •Only use the dedicated charger (CU- 7001, C-700 or C-750) for charging the battery cartridge. Using a different type of charger could cause battery-rupture or leak- age of battery fluid and result in a fire, bodily injury, or serious damage to property. •Never charge the rechargeable battery cartridge where any in- flammable gases may be emitted; doing so could cause fire. Handling the BHT •The BHT-7500W uses a laser light for scanning bar codes. The intensity of the laser light might be too low to inflict bodily in- jury. However, do not look into the laser beam. The BHT-7500W complies with Laser Safety Standard, Class II of 21 CFR Chapter 1, Subchapter J. The BHT-7500W does not mount beam attenuator and laser ra- diation emission indicator required by this standard. Instead, the software-controlled Magic keys (see “Components and Functions”) function as them because the laser light is not en- abled without the Magic keys pressed. AVOID EXPOSURE-LASER LIGHT IS EMITTED FROM THIS APERTURE LASER LIGHT-DO NOT STARE INTO BEAM 1mW MAXIMUM OUTPUT; 650nm LASER CLASS II LASER PRODUCT THIS DEVICE COMPLIES WITH 21 CFR CHAPTER 1, SUBCHAPTER J. C A U T I O N CAUTION Refrigeration Hot- house This humidity is killing me! Refrigeration Refrigeration I'm freezing! I'm burning up! Handling the BHT •Never put the BHT in places where there are excessively high tempera- tures, such as inside closed-up auto- mobiles, or in places exposed to di- rect sunlight. Doing so could affect the housing or parts, resulting in a fire. •Avoid using the BHT in extremely humid or dusty areas, or where there are drastic temperature changes. Moisture or dust will get into the BHT, resulting in malfunction, fire or electrical shock. Handling the rechargeable battery cartridge •Never charge a wet or damp rechargeable battery cartridge. Doing so could cause the batteries to break, generate heat, rup- ture or burn. •Do not look into the laser beam through the reading window or point the laser beam towards the eyes. The laser beam emitted through the reading window is harmful to the eyes. •Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. CAUTION Do not drop me! Keep me away from water! •If foreign material or water gets into the BHT, immediately turn off the power, pull out the rechargeable bat- tery cartridge, and contact your near- est dealer. Failure to do so could cause smoke or fire. •If you drop the BHT so as to damage its housing, immediately turn off the power, pull out the rechargeable bat- tery cartridge, and contact your near- est dealer. Failure to do so could cause smoke or fire. •Never disassemble or modify the BHT; doing so could result in an accident such as break or fire. •If smoke, abnormal odors or noises come from the BHT, imme- diately turn off the power, pull out the rechargeable battery car- tridge, and contact you…

Text truncated - open the document above for the full version.

Users Manual

User’s manual Operation manual Please refer to Attachment 9.1. User’s Manual Requirement of FCC rule KCS is installed in Bar-code handy terminal, so KCS has not manual for user. (Not sale only KCS in US and Canadian marketplace) FCC and RSS-210 user’s manual requirements are described on user’s manual of Bar-code Handy terminal. Also SAR caution statement is described on user’s manual of Bar-code Handy terminal. (Please refer Fig 9.1) Fig 9.1 FCC rule requirement for user’s manual FCC and RSS-210 Regulations This device complies with Part 15of the FCC Rules and RSS-210 Rules Operation is subject to the following two conditions : (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC WARNING : Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE : This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. FCC Radiation Exposure Statement The available scientific evidence does not show that any health problems are associated with using low power wireless devices. There is no proof, however, that these low power wireless devices are absolutely safe. Low power Wireless devices emit low levels of radio frequency energy (RF) in the microwave range while being used. Whereas high levels of RF can produce health effects (by heating tissue), exposure to low level RF that does not produce heating effects causes no known adverse health effects. Many studies of low level RF exposures have not found any biological effects. Some studies have suggested that some biological effects might occur, but such findings have not been confirmed by additional research. The Wireless LAN adapter (KCS) has been tested and found to comply with the Federal Communications Commission (FCC) guidelines on radio frequency energy (RF) exposures. The maximum SAR levels tested for the Wireless LAN adapter (KCS) has been show to be 0.266 W/kg at Body. IC Exposure of Humans to RF Fields The installer of this radio equipment must ensure that the antenna is located or pointed such that it does not emit RF field in excess of Health Canada limits for the general population; consult Safety Code 6, obtainable from Health Canada’s website www.hc-sc.gc.ca/rpb . ICES-003 Regulation This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.

Cover Letter(s)

American Telecommunications Certification Body Inc. 6731 Whittier Ave, McLean, VA 22101 December 29, 2003 RE: FCC ID: PZWKCS_ATCB001022 Attention: Yukie Koyama I have a few comments on this Application. 1. Please note that the manual has a statement that states a 20cm separation is required and you have an ‘insert’ that states SAR. However, there is no indication that the insert is to replace the existing manual statement. Also please note that handheld devices are automatically categorized as portable not mobile. As such the 20cm statement is not correct. Please correct the manual to follow the portable category of this device. 2. Please note that while you have provided a manual of the host, you have not provided the manual/installation guide for the EUT. Please provide this installation guide for this module. 3. Please note that you only show one lead being tested for AC conducted tests. Both lines must be tested. Please provide evidence that both leads (hot and neutral) were tested for conducted emissions. Dennis Ward mailto:[email protected] The items indicated above must be submitted before processing can continue on the above referenced application. Failure to provide the requested information may result in application termination. Correspondence should be considered part of the permanent submission and may be viewed from the Internet after a Grant of Equipment Authorization is issued. Please do not respond to this correspondence using the email reply button. In order for your response to be processed expeditiously, you must submit your documents through the AmericanTCB.com website. Also, please note that partial responses increase processing time and should not be submitted. Any questions about the content of this correspondence should be directed to the sender.

External Photos

DENSO WAVE INCORPORATED FCC ID: PZWKCS (Photos) Antenna Front Antenna Rear DENSO WAVE INCORPORATED FCC ID: PZWKCS Module + Antenna Module Front (with Shield) DENSO WAVE INCORPORATED FCC ID: PZWKCS Module Front (without Shield) Module Rear

ID Label/Location Info

Marking Location Fig. Marking Location on the WLAN Module Location of FCC ID and IC ID label - Marking Layout on the RF module - Marking Layout and Location of Bar code reader 16 9 Unit : mm BHT-XXXXX Contains - FCC ID : PZWKCS - IC : 1551C-KCS THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS : (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. Type : KCS FCC ID : PZWKCS IC : 1551C-KCS

Internal Photos

DENSO WAVE INCORPORATED FCC ID: PZWKCS (Photos) Antenna Front Antenna Rear DENSO WAVE INCORPORATED FCC ID: PZWKCS Module + Antenna Module Front (with Shield) DENSO WAVE INCORPORATED FCC ID: PZWKCS Module Front (without Shield) Module Rear

RF Exposure Info

Test report No. : 24DE0125-HO-5 Page : 1 of 67 Issued date : December 15, 2003 FCC ID : PZWKCS UL Apex Co., Ltd. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone: +81 596 24 8116 Facsimile: +81 596 24 8124 MF058b(10.04.03) SAR EVALUATION REPORT Report No. : 24DE0125-HO-5 Applicant : DENSO WAVE INCORPORATED Type of Equipment : Wireless LAN adapter Model No. : KCS FCC ID : PZWKCS Test standard : FCC47CFR 2.1093 FCC OET Bulletin 65, Supplement C Test Result : Complied Max SAR Measured : 0.266W/kg( Body, 2412MHz ) 1. This test report shall not be reproduced except full or partial, without the written approval of UL Apex Co., Ltd. 2. The results in this report apply only to the sample tested. 3. This equipment is in compliance with above regulation. We hereby certify that the data contain a true representation of the SAR profile. 4. The test results in this test report are traceable to the national or international standards. Date of test : November 28, 2003 Tested by : Miyo Ikuta Head Office EMC Lab. Approved by : Tetsuo Maeno Site Manager of Head Office EMC Lab. Test report No. : 24DE0125-HO-5 Page : 2 of 67 Issued date : December 15, 2003 FCC ID : PZWKCS UL Apex Co., Ltd. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone: +81 596 24 8116 Facsimile: +81 596 24 8124 CONTENTS PAGE SECTION 1 : Client information ................................................................................................................. 3 SECTION 2 : Equipment under test (Wireless LAN adapter) .................................................................. 4 SECTION 3 : Requirements for compliance testing defined by the FCC ................................................ 5 SECTION 4 : Dosimetry assessment setup .................................................................................................. 5 SECTION 5 : Test system specifications...................................................................................................... 9 SECTION 6 : Measurement outline ........................................................................................................... 10 SECTION 7 : Test setup of EUT ................................................................................................................ 11 SECTION 8: Measurement uncertainty .................................................................................................... 15 SECTION 9 : Simulated tissue liquid parameter...................................................................................... 16 SECTION 10 : System validation data ...................................................................................................... 17 SECTION 11 : Evaluation procedure ........................................................................................................ 18 SECTION 12 : Exposure limit .................................................................................................................... 19 SECTION 13 : SAR Measurement results................................................................................................. 20 SECTION 14 : Equipment & calibration information ............................................................................. 21 SECTION 15 : References........................................................................................................................... 22 APPENDIX 1 : Photographs of test setup................................................................................................ 23 APPENDIX 2 : SAR Measurement data .................................................................................................. 32 APPENDIX 3 : Validation Measurement data ........................................................................................44 APPENDIX 4 : System Validation Dipole (D2450V2,S/N: 713)............................................................. 46 APPENDIX 5 : Dosimetric E-Field Probe Calibration (ET3DV6,S/N: 1685) ...................................... 55 Test report No. : 24DE0125-HO-5 Page : 3 of 67 Issued date : December 15, 2003 FCC ID : PZWKCS UL Apex Co., Ltd. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone: +81 596 24 8116 Facsimile: +81 596 24 8124 SECTION 1 : Client information Company Name : DENSO WAVE INCORPORATED Brand Name : DENSO Address : 1-1, Showa-cho, Kariya-shi, Aichi-ken 448-8661, Japan Telephone Number : 81-566-61-3858 Facsimile Number : 81-566-25-4741 Contact Person : Noritaka Hirao Test report No. : 24DE0125-HO-5 Page : 4 of 67 Issued date : December 15, 2003 FCC ID : PZWKCS UL Apex Co., Ltd. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone: +81 596 24 8116 Facsimile: +81 596 24 8124 SECTION 2 : Equipment under test (Wireless LAN adapter) 2.1 Identification of Wireless LAN adapter APPLICANT : DENSO WAVE INCORPORATED Type of Equipment : Wireless LAN adapter Model No. : KCS Serial No. : K03633100001C01 Country of Manufacture : Taiwan Receipt Date of Sample : November 20,2003 Condition of EUT : Production model Category Identified : Portable device 2.2 Product description of Wireless LAN adapter Tx Frequency : 2412MHz~2462MHz Modulation : DSSS Rating : DC3.3 - 3.5V Max.Output Power Tested : 15.75 dBm Peak Conducted Antenna Type : Chip Antenna:YOKOWO YCE-5208DN Test report No. : 24DE0125-HO-5 Page : 5 of 67 Issued date : December 15, 2003 FCC ID : PZWKCS UL Apex Co., Ltd. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone: +81 596 24 8116 Facsimile: +81 596 24 8124 SECTION 3 : Requirements for compliance testing defined by the FCC The US Federal Communications Commission has released the report and order “Guidelines for Evaluating the Environmental Effects of RF Radiation", ET Docket No. 93-62 in August 1996. The order requires routine SAR evaluation prior to equipment authorization of portable transmitter devices…

Text truncated - open the document above for the full version.

RF Exposure Info

Test report No. : 24DE0125-HO-5 Page : 31 of 67 Issued date : December 15, 2003 FCC ID : PZWKCS UL Apex Co., Ltd. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone: +81 596 24 8116 Facsimile: +81 596 24 8124 Top 15mm Test report No. : 24DE0125-HO-5 Page : 32 of 67 Issued date : December 15, 2003 FCC ID : PZWKCS UL Apex Co., Ltd. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone: +81 596 24 8116 Facsimile: +81 596 24 8124 APPENDIX 2 : SAR Measurement data Test report No. : 24DE0125-HO-5 Page : 33 of 67 Issued date : December 15, 2003 FCC ID : PZWKCS UL Apex Co., Ltd. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone: +81 596 24 8116 Facsimile: +81 596 24 8124 KCS / Body / Face / 2437MHz Crest factor: 1 Medium: M2450 (σ = 1.93 mho/m, ε r = 50.2, ρ = 1000 kg/m 3 ) Phantom section: Flat Section DASY4 Configuration: - Probe: ET3DV6 - SN1685; ConvF(4.3, 4.3, 4.3); Calibrated: 2003/10/10 - Sensor-Surface: 4mm (Mechanical And Optical Surface Detection) - Phantom: SAM 1196 - Measurement SW: DASY4, V4.1 Build 47; Postprocessing SW: SEMCAD, V1.6 Build 115 Area Scan (91x131x1): Measurement grid: dx=20mm, dy=20mm Reference Value = 4.29 V/m Power Drift = -0.2 dB Maximum value of SAR = 0.0542 mW/g Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 0.0998 W/kg SAR(1 g) = 0.0526 mW/g; SAR(10 g) = 0.0267 mW/g Maximum value of SAR = 0.0553 mW/g Test date = 11 / 28 / 03 Reference Value = 4.29 V/m Power Drift = -0.2 dB Ambient Temperature = 24.5 degree.c Liquid Temperature = Before 22.7 degree.C , After 22.7 degree.C Test report No. : 24DE0125-HO-5 Page : 34 of 67 Issued date : December 15, 2003 FCC ID : PZWKCS UL Apex Co., Ltd. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone: +81 596 24 8116 Facsimile: +81 596 24 8124 KCS / Body / Back / 2437MHz Crest factor: 1 Medium: M2450 (σ = 1.93 mho/m, ε r = 50.2, ρ = 1000 kg/m 3 ) Phantom section: Flat Section DASY4 Configuration: - Probe: ET3DV6 - SN1685; ConvF(4.3, 4.3, 4.3); Calibrated: 2003/10/10 - Sensor-Surface: 4mm (Mechanical And Optical Surface Detection) - Phantom: SAM 1196 - Measurement SW: DASY4, V4.1 Build 47; Postprocessing SW: SEMCAD, V1.6 Build 115 Area Scan (91x131x1): Measurement grid: dx=20mm, dy=20mm Maximum value of SAR = 0.157 mW/g Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 0.286 W/kg SAR(1 g) = 0.145 mW/g; SAR(10 g) = 0.0734 mW/g Maximum value of SAR = 0.155 mW/g Test date = 11 / 28 / 03 Reference Value = 0.483 V/m Power Drift = -0.2 dB Ambient Temperature = 24.5 degree.c Liquid Temperature = Before 22.6 degree.C , After 22.6 degree.C Test report No. : 24DE0125-HO-5 Page : 35 of 67 Issued date : December 15, 2003 FCC ID : PZWKCS UL Apex Co., Ltd. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone: +81 596 24 8116 Facsimile: +81 596 24 8124 KCS / Body / Right side / 2437MHz Crest factor: 1 Medium: M2450 (σ = 1.93 mho/m, ε r = 50.2, ρ = 1000 kg/m 3 ) Phantom section: Flat Section DASY4 Configuration: - Probe: ET3DV6 - SN1685; ConvF(4.3, 4.3, 4.3); Calibrated: 2003/10/10 - Sensor-Surface: 4mm (Mechanical And Optical Surface Detection) - Phantom: SAM 1196 - Measurement SW: DASY4, V4.1 Build 47; Postprocessing SW: SEMCAD, V1.6 Build 115 Area Scan (91x131x1): Measurement grid: dx=20mm, dy=20mm Reference Value = 0.993 V/m Power Drift = -0.2 dB Maximum value of SAR = 0.0656 mW/g Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 0.109 W/kg SAR(1 g) = 0.0586 mW/g; SAR(10 g) = 0.0317 mW/g Maximum value of SAR = 0.0631 mW/g Test date = 11 / 28 / 03 Reference Value = 0.993 V/m Power Drift = -0.2 dB Ambient Temperature = 24.5 degree.c Liquid Temperature = Before 22.6 degree.C , After 22.6 degree.C Test report No. : 24DE0125-HO-5 Page : 36 of 67 Issued date : December 15, 2003 FCC ID : PZWKCS UL Apex Co., Ltd. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone: +81 596 24 8116 Facsimile: +81 596 24 8124 KCS / Body / Left side / 2437MHz Crest factor: 1 Medium: M2450 (σ = 1.93 mho/m, ε r = 50.2, ρ = 1000 kg/m 3 ) Phantom section: Flat Section DASY4 Configuration: - Probe: ET3DV6 - SN1685; ConvF(4.3, 4.3, 4.3); Calibrated: 2003/10/10 - Sensor-Surface: 4mm (Mechanical And Optical Surface Detection) - Phantom: SAM 1196 - Measurement SW: DASY4, V4.1 Build 47; Postprocessing SW: SEMCAD, V1.6 Build 115 Area Scan (91x131x1): Measurement grid: dx=20mm, dy=20mm Reference Value = 4.75 V/m Power Drift = -0.1 dB Maximum value of SAR = 0.0763 mW/g Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 0.148 W/kg SAR(1 g) = 0.0714 mW/g; SAR(10 g) = 0.0361 mW/g Maximum value of SAR = 0.0751 mW/g Test date = 11 / 28 / 03 Reference Value = 4.75 V/m Power Drift = -0.1 dB Ambient Temperature = 24.5 degree.c Liquid Temperature = Before 22.6 degree.C , After 22.6 degree.C Test report No. : 24DE0125-HO-5 Page : 37 of 67 Issued date : December 15, 2003 FCC ID : PZWKCS UL Apex Co., Ltd. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone: +81 596 24 8116 Facsimile: +81 596 24 8124 KCS / Body / Top 0mm/ 2437MHz Crest factor: 1 Medium: M2450 (σ = 1.93 mho/m, ε r = 50.2, ρ = 1000 kg/m 3 ) Phantom section: Flat Section DASY4 Configuration: - Probe: ET3DV6 - SN1685; ConvF(4.3, 4.3, 4.3); Calibrated: 2003/10/10 - Sensor-Surface: 4mm (Mechanical And Optical Surface Detection) - Phantom: SAM 1196 - Measurement SW: DASY4, V4.1 Build 47; Postprocessing SW: SEMCAD, V1.6 Build 115 Area Scan (91x131x1): Measurement grid: dx=20mm, dy=20mm Reference Value = 11.2 V/m Power Drift = 0.1 dB Maximum value of SAR = 0.199 mW/g Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Peak SAR (extrapolated) = 0.483 W/kg SAR(1 g) = 0.194 mW/g; SAR(10 g) = 0.082 mW/g Maximum value of SAR = 0.207 mW/g Zoom…

Text truncated - open the document above for the full version.

Test Report

Test report No. : 24DE0125-HO-1 Page : 1 of 31 Issued date : December 5, 2003 FCC ID : PZWKCS UL Apex Co., Ltd. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 MF060b(10.04.03) EMI TEST REPORT Test Report No. : 24DE0125-HO-1 Applicant : DENSO WAVE INCORPORATED Type of Equipment : Wireless LAN Adapter Model No. : KCS Test standard : FCC Part 15 Subpart C Section 15.207, Section 15.247 FCC ID : PZWKCS Test Result : Complied 1. This test report shall not be reproduced in full or partial, without the written approval of UL Apex Co., Ltd. 2. The results in this report apply only to the sample tested. 3. This equipment is in compliance with above regulation. We hereby certify that the data contain a true representation of the EMC profile. 4. The test results in this report are traceable to the national or international standards. 5. This test report does not constitute an endorsement by NIST/NVLAP or U.S. Government. Date of test : November 4, 15, 24 and December 1, 2003 Tested by : Naoki Sakamoto EMC Service Approved by : Hironobu Shimoji Group Leader of EMC Service Test report No. : 24DE0125-HO-1 Page : 2 of 31 Issued date : December 5, 2003 FCC ID : PZWKCS UL Apex Co., Ltd. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 MF060b(10.04.03) CONTENTS PAGE SECTION 1: CLIENT INFORMATION..................................................................................3 SECTION 2: EQUIPMENT UNDER TEST (E.U.T.)..............................................................3 SECTION 3: TEST SPECIFICATION, PROCEDURES & RESULTS................................5 SECTION 4: OPERATION OF E.U.T. DURING TESTING.................................................7 SECTION 5: CONDUCTED EMISSION, SECTION 15.207.................................................9 SECTION 6: 6DB BANDWIDTH, SECTION 15.247(A)(2)...................................................9 SECTION 7: MAXIMUM PEAK OUTPUT POWER, SECTION 15.247(B)(3)..................9 SECTION 8: OUT OF BAND EMISSION, SECTION 15.247 (C).......................................10 SECTION 9: PEAK POWER DENSITY, SECTION 15.247 (C).........................................10 APPENDIX 1: PHOTOGRAPHS OF TEST SETUP............................................................11 Conducted Emission..................................................................................................11 Spurious Emission (Radiated)..................................................................................12 Three axes X, Y, Z...........................................................................................................13 APPENDIX 2:TEST INSTRUMENTS.....................................................................................14 APPENDIX 3: DATA OF EMI TEST......................................................................................15 Conducted Emission..................................................................................................15 6dB BANDWIDTH(Conducted)...............................................................................16 Maximum Peak OutPut Power (Conducted)..........................................................18 Out of Band Emission : Radiated Emission............................................................19 Restricted Band Edges : Radiated(Ch1:2412MHz)................................................25 Restricted Band Edges : Radiated(Ch11:2462MHz)..............................................26 Out of Band Emission : Conducted(Ch 1:2412MHz 20dBc).................................27 Out of Band Emission : Conducted(Ch 6:2437MHz 20dBc).................................28 Out of Band Emission : Conducted(Ch 6:2462MHz 20dBc).................................29 Power Density (Conducted)......................................................................................30 Test report No. : 24DE0125-HO-1 Page : 3 of 31 Issued date : December 5, 2003 FCC ID : PZWKCS UL Apex Co., Ltd. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 MF060b(10.04.03) SECTION 1: Client information Company Name : DENSO WAVE INCORPORATED Address : 1-1, Showa-cho, Kariyashi, Aichi-ken Japan Telephone Number : +81-566-61-3858 Facsimile Number : +81-566-25-4741 Contact Person : Noritaka Hirao SECTION 2: Equipment under test (E.U.T.) 2.1 Identification of E.U.T. Type of Equipment : Wireless LAN adapter Model No. : KCS Serial No. : K03633100001C01 Country of Manufacture : Taiwan Receipt Date of Sample : October 30, 2003 Condition of EUT : Production model Test report No. : 24DE0125-HO-1 Page : 4 of 31 Issued date : December 5, 2003 FCC ID : PZWKCS UL Apex Co., Ltd. Head Office EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8116 Facsimile : +81 596 24 8124 MF060b(10.04.03) 2.2 Product Description DENSO WAVE INCORPOR ATED ., Model No: KCS is the Wireless LAN adapter. This product is 2.4GHz Wireless LAN of DSSS installed in barcode scanner. RF specification is accordance with IEEE802.11b. The clock frequency of EUT are 44MHz, 32.768kHz. Equipment Type : Transceiver Frequency band : 2400-2483.5MHz Frequency operation : 2412-2462MHz Type of modulation : DSSS(IEEE802.11b) CCK(5.5/11Mbps), BPSK(1Mbps), QPSK(2Mbps) Channel spacing : 5MHz Channel access protocol : PTA Mode of operation : Simplex Antenna Type : Chip Antenna Antenna Gain : -3.86dBi Antenna connector Type : Hirose CL331-0471-0-10X1 Method of Frequency Generation : Synthesizer Power Supply : DC3.0-3.6V FCC 15.31 (e) This EUT provides stable voltage(DC*V) constantly to RF Module regardless of input voltage. Therefore, this EUT complies with the requirement. FCC Part 15.203 Antenna requirement Type of Equipment and its antenna comply with this requirement since they are built in host device Model No. When they are put u…

Text truncated - open the document above for the full version.

Test Setup Photos

Test report No. : 24DE0…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Takehiko Koshino(Proj. Mgr, AUTO-ID Business Unit Eng. Plan.Div.)
[email protected]81-569-49-5339Fax: 81 569 49 5488

Technical Contact

UL Apex Co., Ltd.Naoki Sakamoto
[email protected]81-596-24-8116

4383-326 Asama-cho, · Ise-shi, Mie-ken · Japan

Test Firm

UL Apex Co., Ltd.Tetsuya Hashimoto
[email protected]81-596-24-8116Fax: 81-596-24-8124

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz36.00 mW
Modular Type
Single Modular Approval
Confidentiality
Long Term
Grant Notes
Power Output listed is Conducted. Modular Approval for use in the bar code scanner or similar as indicated in the filing. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. The SAR data in this filing is applicable to demonstrate compliance of the module in the DENSO WAVE Bar Code Scanner or similar as shown in this filing. The highest SAR value for this device as reported to the FCC is: Body; 0.266 Watts/kg.

Other Applications from Denso Wave Incorporated

PZWSE1BUBC

RF Tag Handy Scanner

Jan 17, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2D Code Handy Terminal - FCC ID PZWBHTM80QW - Denso Wave Incorporated
PZWBHTM80QW

2D Code Handy Terminal

Feb 04, 2021

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2D Code Handy Terminal - FCC ID PZWBHTM80QWG - Denso Wave Incorporated
PZWBHTM80QWG

2D Code Handy Terminal

Jan 27, 2021

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Fixed Type RFID Scanner - FCC ID PZWUR50MERU - Denso Wave Incorporated
PZWUR50MERU

Fixed Type RFID Scanner

Jan 13, 2021

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2D Code Handy Terminal - FCC ID PZWBHT1200QU - Denso Wave Incorporated
PZWBHT1200QU

2D Code Handy Terminal

Sep 21, 2015

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter