SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch Application No..: GZEM1502000769CR Page: 1 of 1 FCC ID: Q22IF912B This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspxand,for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 days only. RF Exposure Compliance Requirement The product belongs to standalone portable device base the FCC rule part 2.1091&2.1093. The transmission frequencies of the device are between 100 MHz and 6 GHz. The worst case test separation distance is 5mm. The Max Conducted Output Power and SAR Test Exclusion Threshold (mW) are listed below: Transmit frequency (GHz) Max Conducted Output Power (mW) SAR Test Exclusion Threshold (mW) 2.402 -5.88 9.7 2.440 -6.75 9.6 2.480 -8.18 9.5 The SAR Test Exclusion Threshold for 100 MHz to 6 GHz is calculated from: 1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where f(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. According to SAR Exclusion Threshold in KDB 447498 (D01) General RF Exposure Guidance v05r02, the SAR report is not required.
Test Setup Photos 1.1 RADI ATE D SP URI OU S EM ISSIO N TE ST SETUP Below 1GHz: Above 1GHz: (full anechoic chamber)
198 KEZHU Road, Scientech Park, Guangzhou · Guangzhou · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 258.00 µW |

Weighplate
Equipment Class
DTS - Digital Transmission System
Smart Body Fat Scale
Equipment Class
DTS - Digital Transmission System
Smart Body Fat Scale
Equipment Class
DTS - Digital Transmission SystemSmart Body Fat Scale
Equipment Class
DTS - Digital Transmission System
Smart Body Fat Scale
Equipment Class
DTS - Digital Transmission System