Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Copyright Statement Copyright © 2010 by ZTE Corporation All rights reserved. No part of this publication may be excerpted, reproduced, translated or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without the prior written permission of ZTE Corporation. ZTE Corporation reserves the right to make modifications on print errors or update specifications in this manual without prior notice. Table of Contents 1. Introduction ........................................................................................................ 1 2. Precautions ......................................................................................................... 1 3. Appearance ......................................................................................................... 3 3.1 Introduction..................................................................................................... 3 3.2 Operation Guide of Data Cable...................................................................... 4 4. Install and Uninstall ........................................................................................... 4 4.1 System Requirements .................................................................................... 4 4.2 Installation ...................................................................................................... 5 4.3 Uninstallation.................................................................................................. 5 5. Run the Application ........................................................................................... 6 6. Open URL ............................................................................................................ 8 7. Service................................................................................................................. 8 8. Voice Call............................................................................................................. 8 9. Call Log ..............................................................................................................11 10. SMS .................................................................................................................. 12 11. NetConnect ..................................................................................................... 15 12. NetConnect Log.............................................................................................. 16 13. Phonebook ...................................................................................................... 17 14. Settings ........................................................................................................... 19 15. Help.................................................................................................................. 22 16. RF Exposure Information (SAR) ................................................................... 23 17. Trouble-shooting............................................................................................ 25 18. FCC Regulations ............................................................................................ 27 1 1. Introduction Thank you for choosing AC8720 CDMA2000 1X Wireless USB Modem (hereinafter referred to as USB Modem) of ZTE Corporation. The USB Modem equips with a standard USB interface and supports CDMA2000 1X network. In the area where there is signal, it allows you to go surf the Internet, send & receive short messages, and make & receive phone calls. The USB Modem adopts two designing options: R-UIM and Built-in UIM, which make your operation more flexible. The pictures in this guide are only used to demonstrate your USB Modem’s functions, so they are maybe different from what you see on your USB Modem. Please refer to your USB Modem if they are differences. 2. Precautions ● Use the original accessories or those authenticated by the manufacturer. Using any unauthenticated accessories may affect the USB Modem’s performance, violate the warranty provisions or relevant national regulations about telecom terminals, or even cause body injury. ● Do not disassemble, modify, frequently pull/plug the antenna, stretch, rotate or bend the antenna with great force. ● Before pulling out the USB Modem, please use Windows safely removing the hardware and make sure to exit the application. Do not directly pull out 2 the terminal to avoid the damage of USB Modem or the influence on the normal operation of operating system. ● Do not forcefully plug/pull the USB Modem to avoid the damage of connector. ● Do not use your USB Modem near weak signal or high-precision electronic devices. Radio wave interference may cause misoperation of electronic devices or other problems. ● Turn off your USB Modem on airplane where it’s forbidden to use it. The USB Modem may affect the normal operation of electronic devices, therefore please follow the relevant regulations when using your USB Modem on airplane. ● Turn off your USB Modem in hospital where it’s forbidden to use it. The USB Modem may affect the normal operation of medical apparatus, therefore please follow the relevant regulations when using your USB Modem in hospital. ● Please do not use the USB Modem near flammable or explosive materials; otherwise it might cause failure or fire. ● Keep your USB Modem away from water. This may cause overheating or failure if water or any other kind of liquid enters your USB Modem. Please do not use your USB Modem near high temperature, damp or dusty place. ● Keep your USB Modem away from children to avoid shock, plunge or impact. It may cause body injury when the USB Modem is used as a toy. 3 3. Appearance 3.1 Introduction 4 3.2 Operation Guide of Data Cable Generally, the USB Modem could be directly connected with USB port. You could also connect the USB Modem with PC by using the accompanying data cable, as shown in the following figure. Connect Interface with USB Modem…
Text truncated - open the document above for the full version.
ZTE CORPORATION ZTE Plaza, Keji Road South, Hi-Tech, Industrial Park, Nanshan District, Shenzhen, Guangdong, P.R.China Date: October 27, 2011 Power of Attorney To whom it may concern, Please be notified that I, Royce Wang have designated Tommy Leung / Shawn Xing in Intertek testing services as the persons responsible for this project and to sign the form 731 and other documentation. Any and all acts carried out by Tommy Leung / Shawn Xing in Intertek testing services, on the matters of relating to all processes required in the FCC approval and any communication needed with the national authority, shall have the same legal authority as acts on our own behalf. This authorization is limited to the product of as following: FCC ID: Q78-AC8730 Any acknowledgement and response, please send it to Intertek testing services directly. Should you have any questions or comments regarding this matter, please have my best attention. Sincerely yours, Royce Wang ZTE CORPORATION Tel: 0755-26770345 Fax: 0755-26770347 E-Mail: [email protected]
ZTE CORPORATION ZTE Plaza, Keji Road South, Hi-Tech, Industrial Park, Nanshan District, Shenzhen, Guangdong, P.R.China Date: October 27, 2011 To whom it may concern, Request for Permanent Confidentiality FCC ID: Q78-AC8730 Request is hereby submitted by ZTE Corporation to withhold permanently from public review certain portions of the application for equipment certification for the referenced FCC identifiers. This request for confidentiality is made pursuant to 47 CFR § 0.457(d) and 0.459 of the FCC Rules. In particular, the following sections of the application are to be kept permanently confidential and ZTE Corporation reserves the right to discern which parties can obtain access to these information: Schematics Detailed Block diagrams Detailed Operational/Functional Description Tune up procedure Part List The rationale for request for confidentiality is as followings: This information represents intellectual property of ZTE Corporation and it is subject to competition. We have invested considerable time and materials in research and development to produce the referenced product. Disclosure of the permanently confidential portions of this application to competitors would not only give them significant competitive advantages in developing similar products, but would also disclose successful implementation of unpublished, leading edge technology developed by us. If you have questions or need further information, please contact the undersigned. Regards, Royce Wang Tel: 0755-26770345 E-Mail: [email protected]
INTERTEK TESTING SERVICES External Photos: INTERTEK TESTING SERVICES INTERTEK TESTING SERVICES
Label Artwork and Location Label Size: 20*13mm FCC ID: Q78-AC8730
Label Artwork and Location Label Size: 20*13mm FCC ID: Q78-AC8730
INTERTEK TESTING SERVICES Internal photos INTERTEK TESTING SERVICES INTERTEK TESTING SERVICES
Radiated Photos
Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report 1 COMOSAR E-FIELD PROBE CALIBRATION REPORT Prepared By: LUC Jérôme, SATIMO Project Description: SAR TEST BENCH Prepared For (End User): Shenzhen Morlab Communication Technology This document is issued by SATIMO, in confidence and is not to be reproduced in whole or in part without the prior written permission. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or in part without the prior written permission of SATIMO. Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report 2 COMOSAR SEPT ISOTROPIC E-FIELD PROBE CALIBRATION REPORT DATE: 12/02/2009 REFERENCE: SN 37/08 EP80 OBJECT: COMOSAR SEPT ISOTROPIC E-FIELD PROBE MANUFACTURER: SATIMO SERIAL NUMBER: SN 37/08 EP80 CUSTOMER: Shenzhen Morlab Communication Technology CONTRACT: PF2130108b_SAR_Morlab DATE OF CALIBRATION: 24/09/20 WARRANTY: This Calibration certificate may not be reproduced other than in full. Calibration certificates without signature and seal are not valid. This documentation contains property information which is protected by copyright. All right are reserved. No part of this document may be photocopied, reproduced without the prior written agreement of SATIMO. SATIMO shall not be liable for errors contained herein or for incidental or consequential in connection with the furnishing, performance or use of this material. Warranty doesn’t apply to Normal wear, Normal tear, Improper use, Improper maintain, Improper installation. Date SAR TEAM MANAGER Date SAR TEAM MANAGER Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report 3 PRODUCT DESCRIPTION Frequency Range 100 MHz - 30 GHz Probe length 330 mm Length of one dipole 4.5 mm Maximum external diameter 8 mm Probe extremity diameter 6.5 mm Distance between dipoles/probe extremity < 2.7 mm Resistance of the three dipole (at the connector) Dipole 1: R1=1.4382 MΩ Dipole 2: R2=1.4894 MΩ Dipole 3: R3=1.4683 MΩ Connector (HIROSE series SR30) 6 wire male (Hirose SR30series) The probe could be checked by measuring the resistance of the three dipoles. CALIBRATION TEST EQUIPMENT TYPE IDENTIFICATION Calibration bench CALISAR Multimeter Keithley 2000 Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report 4 MEASUREMENT PROCEDURE Probe calibration is realized, in compliance with CENELEC EN 50361 and IEEE 1528 std, with CALISAR, Antennessa proprietary calibration system. The calibration is performed with the EN 50361 annexe technique using reference guide at the five frequencies. Where : P fw = Forward Power P bw = Backward Power a and b = Waveguide dimensions = Skin depth Keithley configuration: Rate = Medium; Filter =ON; RDGS=10; FILTER TYPE =MOVING AVERAGE; RANGE AUTO After each calibration, a SAR measurement is performed on a validation dipole and compared with a NPL calibrated probe, to verify it. Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report 5 PROBE UNCERTAINTIES Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report 6 1. Calibration at 450.00 MHz A. Calibration parameters. Label GSM450 Epsilon 43.33 Sigma 0.84 S/m Temperature 21°C Antenna gain 2.03 dB Antenna S11 -10.50 dB Low limit detection (CW) Calibration curves ei=f(V) (i=1,2,3) allow to obtain E-field value using the formula: EEEE= The following tables represent the calibration curves linearization by curve segment in CW signal. Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report 7 Calibration coefficients for the three dipoles in CW: v1 e1 v2 e2 v3 e3 0.584004 419.557857 -0.696059 435.622023 0.541191 412.830715 0.467833 339.207465 -0.556278 351.381991 0.469757 336.297240 0.376994 276.348283 -0.452232 288.647980 0.378826 274.224190 0.302778 224.954643 -0.359005 232.397390 0.305842 224.365698 0.241038 182.154071 -0.286978 188.889931 0.246562 183.825274 0.192549 148.484090 -0.230386 154.650994 0.195712 148.993075 0.154033 121.674762 -0.185412 127.378480 0.157543 122.783107 0.123397 100.276479 -0.147311 104.193802 0.125866 100.956090 0.099878 83.770361 -0.118637 86.660489 0.101471 84.063863 0.081165 70.553219 -0.095250 72.263937 0.082289 70.694342 0.065166 59.152028 -0.076788 60.795323 0.066427 59.538957 0.051916 49.592416 -0.061280 51.041514 0.053353 50.232492 0.041968 42.297602 -0.048746 43.022565 0.042906 42.675214 0.033724 36.126757 -0.039149 36.748110 0.034686 36.605243 0.021855 26.962568 -0.024798 27.024723 0.022272 27.149463 0.018405 23.975145 -0.020856 24.085809 0.018755 24.141334 0.015467 21.515985 -0.017534 21.515985 0.015767 21.615299 0.013018 19.309065 -0.014750 19.398191 0.013276 19.487731 0.010938 17.408496 -0.012392 17.529166 0.011157 17.569575 0.009022 15.586953 -0.010228 15.658899 0.009215 15.676938 0.007353 13.956010 -0.008328 13.988181 0.007484 14.020428 0.005989 12.466979 -0.006801 12.495719 0.006111 12.567858 0.004890 11.214019 -0.005573 11.265779 0.005003 11.330818 0.004019 10.133541 -0.004570 10.121882 0.004099 10.168601 0.003279 9.094132 -0.003739 9.157170 0.003352 9.125596 0.002660 8.095827 -0.003041 8.293946 0.002769 8.265350 0.002126 7.324219 -0.002453 7.366500 0.002188 7.358024 0.001685 6.565400 -0.001947 6.580536 0.001724 6.542765 0.001300 5.784440 -0.001511 5.718225 0.001334 5.757862 0.001123 5.245191 -0.001307 5.269400 0.001174 5.275471 0.000891 4.701768 -0.001057 4.723470 0.000924 4.728912 0.000704 4.209798 -0.000850 4.226839 0.000736 4.243862 0.000574 3.790376 -0.000689 3.791428 0.000603 3.830551 0.000457 3.396200 -0.000570 3.434303 0.000483 3.421852 0.000365 3.050686 -0.000463 3.078014 0.000389 3.079630 0.000292 2.745766 -0.000369 2.726866 0.00031…
Text truncated - open the document above for the full version.
SZ11100033S01 Page 2 of 51 DIRECTORY 1. TESTING LABORATORY ....................................................................................................... 4 1.1. Identification of the Responsible Testing Laboratory ......................................................... 4 1.2. Identification of the Responsible Testing Location .............................................................. 4 1.3. Accreditation Certificate ........................................................................................................ 4 1.4. List of Test Equipments .......................................................................................................... 4 2. TECHNICAL INFORMATION ............................................................................................... 5 2.1. Identification of Applicant ..................................................................................................... 5 2.2. Identification of Manufacturer .............................................................................................. 5 2.3. Equipment Under Test (EUT) ................................................................................................ 5 2.3.1. Photographs of the EUT .................................................................................................. 5 2.3.2. Identification of all used EUTs ........................................................................................ 5 2.4. Applied Reference Documents ............................................................................................... 6 2.5. Device Category and SAR Limits .......................................................................................... 6 2.6. Test Environment/Conditions ................................................................................................ 7 3. SPECIFIC ABSORPTION RATE (SAR) ................................................................................ 8 3.1. Introduction ............................................................................................................................. 8 3.2. SAR Definition......................................................................................................................... 8 4. SAR MEASUREMENT SETUP ............................................................................................... 9 4.1. The Measurement System ...................................................................................................... 9 4.2. Probe ........................................................................................................................................ 9 4.3. Phantom ................................................................................................................................. 11 4.4. Device Holder ........................................................................................................................ 11 5. TISSUE SIMULATING LIQUIDS ......................................................................................... 12 6. UNCERTAINTY ASSESSMENT ........................................................................................... 13 6.1. UNCERTAINTY EVALUATION FOR HANDSET SAR TEST ...................................... 13 6.2. UNCERTAINTY FOR SYSTEM PERFORMANCE CHECK ........................................ 14 7. SAR MEASUREMENT EVALUATION ............................................................................... 16 7.1. System Setup .......................................................................................................................... 16 7.2. Validation Results .................................................................................................................. 16 8. OPERATIONAL CONDITIONS DURING TEST ................................................................ 17 8.1. Informations on the testing .................................................................................................. 17 SZ11100033S01 Page 3 of 51 8.2. Body-worn Configurations ................................................................................................... 17 8.3. Measurement procedure ....................................................................................................... 18 8.4. Description of interpolation/extrapolation scheme ............................................................ 18 9. 3G MEASUREMENT PROCEDURES .................................................................................. 19 9.1. Procedures Used To Establish Test Signal .......................................................................... 19 9.2. SAR Measurement Conditions for CDMA ......................................................................... 19 9.3. Output Power Verification ................................................................................................... 19 9.4. SAR Measurement ................................................................................................................ 19 10. TEST RESULTS LIST ............................................................................................................. 21 ANNEX A PHOTOGRAPHS OF THE EUT ................................................................................ 22 ANNEX B GRAPH TEST RESULTS ........................................................................................... 25 Change History Issue Date Reason for change 1.0 2011-10-27 First edition 2.0 2011-11-17 Second edition SZ11100033S01 Page 4 of 51 1. Testing Laboratory 1.1. Identification of the Responsible Testing Laboratory Company Name: Shenzhen Morlab Communications Technology Co., Ltd. Department: Morlab Laboratory Address: 3/F, Electronic Testing Building, Shahe Road, Nanshan District, Shenzhen, 518055 P. R. China Responsible Test Lab Manager: Mr. Shu Luan Telephone: +86 755 86130268 Facsimile: +86 755 86130218 1.2. Identification of the Responsible Testing Location Na…
Text truncated - open the document above for the full version.
Intertek Testing Services Shenzhen Ltd. Kejiyuan Branch 6F, D Block, Huahan Building, Langshan Road, Nanshan District, Shenzhen, P. R. China Tel: (86 755) 8601 6288 Fax: (86 755) 8601 6751 Website: www.china.intertek-etlsemko.com 27 Oct, 2011 ZTE Corporation ZTE Plaza, Hi-tech Park, Nanshan District, Shenzhen, Guangdong China Tel.: (86) 755-26770345 Fax: (86) 755-26770347 Dear Royce Wang: Enclosed you will find your file copy of an Original Grant of Part 22 Certification report (FCC ID: Q78-AC8730). Model: AC8730. For your reference, TCB will normally take another 1 weeks for reviewing the report. Approval will then be granted when no query is sorted. Please contact me if you have any questions regarding the enclosed material. Sincerely, Leung Wai Leung, Tommy Deputy General Manager Enclosure Intertek Testing Services Shenzhen Ltd. Kejiyuan Branch 6F, D Block, Huahan Building, Langshan Road, Nanshan District, Shenzhen, P. R. China Tel: (86 755) 8601 6288 Fax: (86 755) 8601 6751 Website: www.china.intertek-etlsemko.com List of Exhibits Exhibit Type File Description Filename Test Report Test Report report.pdf Operational Description Technical Description descri.pdf Test Report Bandwidth Plot 99% bw.pdf Test Report Spurious Emissions cspurious.pdf Test Report Bandedge Plot be.pdf RF Exposure Info SAR Report sar report 1 of 3.pdf sar report 2 of 3.pdf sar report 3 of 3.pdf External Photos External Photo external photos.pdf Internal Photos Internal Photo internal photos.pdf ID Label/Location Info Label Artwork and Location label.pdf Schematics Circuit Diagram circuit.pdf User Manual User Manual manual.pdf Part List/Tune Up Info Tune Up Procedure tuneup.pdf Part List/Tune Up Info Part List partlist.pdf Cover Letter Letter of Agency letter of agency.pdf Cover Letter Confidentiality Request request.pdf • The test results reported in this test report shall refer only to the sample actually tested and shall not refer or be deemed to refer to bulk from which such a sample may be said to have been obtained. • This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results referenced from this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. • For Terms And Conditions of the services, it can be provided upon request. • The evaluation data of the report will be kept for 3 years from the date of issuance. TRF No.: FCC 22H&24E_a Intertek Testing Services Shenzhen Ltd. Kejiyuan Branch 6F, D Block, Huahan Building, Langshan Road, Nanshan District, Shenzhen, P. R. China Tel: (86 755) 8601 6288 Fax: (86 755) 8601 6751 Website: www.china.intertek-etlsemko.com TEST REPORT Report Number: SZ11100068-1 Application for Original Grant of 47 CFR Part 22 Certification CDMA 1X Wireless data Terminal FCC ID: Q78-AC8730 Prepared and Checked by: Approved by: Billy Li Leung Wai Leung, Tommy Team Leader Deputy General Manager 27 Oct, 2011 27 Oct, 2011 INTERTEK TESTING SERVICES TRF: FCC 22H&24E_a Test Report Number: SZ11100068-1 Page 1 of 17 FCC ID: Q78-AC8730 GENERAL INFORMATION Applicant Name: ZTE Corporation Applicant Address: ZTE Plaza, Hi-tech Park, Nanshan District, Shenzhen, Guangdong China FCC Specification Standard: FCC Part 22: 2010 FCC ID: Q78-AC8730 FCC Model(s): AC8730 Type of EUT: CDMA1X Description of EUT: CDMA 1X Wireless data Terminal Brand Name: ZTE 中兴 Serial Number: N/A Sample Receipt Date: 10 Oct, 2011 Date of Test: 10 Oct, 2011 to 27 Oct, 2011 Report Date: 27 Oct, 2011 Environmental Conditions: Temperature: 25 ± 10°C Humidity: 10 to 90% INTERTEK TESTING SERVICES TRF: FCC 22H&24E_a Test Report Number: SZ11100068-1 Page 2 of 17 FCC ID: Q78-AC8730 Table of Contents 1.0 Summary of Test Results.................................................................................................................................. 3 1.1 Statement of Compliance................................................................................................................................ 3 2.0 General Description............................................................................................................................................ 4 2.1 Product Description........................................................................................................................................... 4 2.3 Test Methodology.............................................................................................................................................. 5 2.4 Test Facility........................................................................................................................................................ 5 3.0 System Test Configuration................................................................................................................................ 6 3.1 Justification.........................................................................................................................................................6 3.3 Details of EUT and Description of Accessories.............................................................................................. 8 3.4 Measurement Uncertainty................................................................................................................................. 8 3.5 Equipment Modifi…
Text truncated - open the document above for the full version.
INTERTEK TESTING SERVICES CDMA 1X 800MHz Band A Att 40 dB * Offset 3 dB LVL 1 PK MAXH Ref 30 dBm Center 836.52 MHzSpan 2 MHz200 kHz/ EXT * * 3DB RBW 30 kHz VBW 100 kHz SWT 10 ms -70 -60 -50 -40 -30 -20 -10 0 10 20 30 1 Marker 1 [T1 ] 12.89 dB m 836.228333333 MHz OBW 1.269230769 MHz T1 Temp 1 [T1 OBW] 4.62 dB m 835.885384615 MHz T2 Temp 2 [T1 OBW] 4.34 dBm 837.154615385 MHz
INTERTEK TESTING SERVICES CDMA1X 800MHz Band
INTERTEK TESTING SERVICES CDMA1X 800MHz Band A Att 40 dB * Offset 3 dB LVL 1 PK MAXH Ref 30 dBm EXT 99.9 MHz/Start 1 MHzStop 1 GHz * 3DB RBW 100 kHz * VBW 300 kHz SWT 100 ms -70 -60 -50 -40 -30 -20 -10 0 10 20 30 1 Marker 1 [T1 ] 16.23 dBm 836.701923077 MHz D1 -13 dBm Ref 30 dBmAtt 40 dB * Offset 3 dB 1 PK MAXH A LVL EXT 800 MHz/Start 1 GHzStop 9 GHz * 3DB RBW 100 kHz SWT 800 ms * VBW 300 kHz -70 -60 -50 -40 -30 -20 -10 0 10 20 30 1 Marker 1 [T1 ] -41.25 dB m 2.897435897 GHz D1 -13 dBm
Conducted photos
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 1 | 22H | 824.7 MHz - 848.31 MHz | 65.00 mW | 1M27F9W | 0.0200000000 ppm |

Home Gateway
Equipment Class
NII - Unlicensed National Information Infrastructure TX
Home Gateway
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
RichMedia Box
Equipment Class
DTS - Digital Transmission System
Home Gateway
Equipment Class
NII - Unlicensed National Information Infrastructure TX
Home Gateway
Equipment Class
NII - Unlicensed National Information Infrastructure TX