FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. ZTE Corporation/
  3. Q78-MF226

Q78-MF226HSPA+ LGA Module

ZTE Corporation
HSPA+ LGA Module - FCC ID Q78-MF226 - ZTE Corporation
Click to zoom

Application Details

Equipment Class
PCB - PCS Licensed Transmitter
Date of Grant
Apr 01, 2011
Application Purpose
Original Equipment
Date of Application
Mar 12, 2011
Equipment Note
HSPA+ LGA Module
Frequency Range
826.40000000 - 846.60000000
Company
ZTE Corporation
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1 1 Introduction 1.1 Introduction This is a multi-mode 3G LGA module. It works in HSDPA/HSUPA/HSPA+/ UMTS/EDGE/GPRS/GSM networks. It integrates the functionality of a modem and a mobile phone (SMS), and combines mobile communication with Internet perfectly. It supports data, and SMS services through the mobile phone network, enabling you to communicate anytime and anywhere. 1.2 Functions Functions SMS, Data service, Applications management, A-GPS, etc. Network Standards. HSDPA/HSUPA/HSPA+/UMTS/EDGE/GPRS/GSM Transmission (Max. data rate) HSPA+:14Mbps DL HSUPA:5.76Mpbs UL 1.3 FCC Compliance This device complies with part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference. Caution: Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following 2 measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/ TV technician for help. 1.3 FCC Compliance This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Caution: Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/ TV technician for help. 3 1.4 RF Exposure Your device contains a transmitter and a receiver. When it is ON, it receives and transmits RF energy. When you communicate with your device, the system handling your connection controls the power level at which your device transmits. Important safety information regarding radiofrequency radiation (RF) exposure. To ensure compliance with RF exposure guidelines the device must be used with a separation from the body. Failure to observe these instructions could result in your RF exposure exceeding the relevant guideline limits. The maxim permissible exposure is defined in 47 CFR 1.1310 with 1mW/cm*cm. The transmitter is using external antenna that operate at 20cm or more from nearby persons. The maxim power density is 0.562mW/cm*cm. The FCC grant can be found under the Display Grant section of http://www.fcc.gov/oet/fccid after searching on FCC ID: Q78-MF226. “Note: if the FCC identification number is not visible when the module is installed inside another device, the outside of the device into which the module is installed must also display a label referring to the enclosed module. This exterior label can use wording such as the following: “Contains Transmitter Module FCC ID: Q78-MF226” or “Contains FCC ID: Q78-MF226” Any similar wording that expresses the same meaning may be used. 2 Installation 2.1 Install Software 1. It is strongly recommended that you exit all other Windows programs, and then click the Next button. 4 2. Select the folder that you want to install the software by pressing the Change button, and then click the Next button. 5 3. The system shows the installation progress, wait a minute and click the Finish button to complete the installation. 6 Note: After the software is installed, pull out the modem before restarting the computer to avoid damages to your modem. If you have problems with the installation steps above, please contact your service provider or ZTE. After the installation, select Start > Programs > Connect Manager. You can find Connect Manager and Uninstall. There will be a shortcut icon on the desktop just as follows. 2.2 Run the Application Software After the modem is correctly connected to the computer, click Start > Programs > Connect Manager > Connect Manager on the computer to run the application software. 7 You can also launch the application software by double-clicking the shortcut icon shown above. After the modem is initialized, the main interface of the connection manager appears. The standby icon appearing in the taskbar indicates the modem…

Text truncated - open the document above for the full version.

Attestation Statements

ZTE Corporation Zhongxing Bldg, Shenzhen Hi-tech Industrial Park Nanshan District, Shenzhen city, GuangDong Province, P.R.China 518057 Tel: 086-021-68895196 Fax: 086-021-50801070 Module Characteristics Declaration We declare that our HSPA+ LGA Module product Product Model: ZTE-MF226 (FCC ID: Q78-MF226) has the following module characteristics: Item 1 2 3 4 5 6 7 8 Requirements Have its own RF shielding Have buffered modulation/data inputs (if such inputs are provided) Have it own power supply regulation Meet the antenna requirements of Section 15.203 Be tested in a stand-alone configuration, i.e. the antenna, AC or DC power and data input/output lines must be connected to the module but, the module must not be inside another case during testing Be labeled with its own FCC ID number, and if the FCC ID is not visible when the module is installed inside another device, then the outside of the device into which the module is installed must also display a label referring to the enclosed module. The modular transmitter is manufactured so that the user cannot influence the operation of the transmitter that will operate outside of the scope of the regulations. Address compliance with the commission’s RF exposure limits Sections 1.1310 and 2.1093. In addition, spread spectrum transmitters operating under Section 15.247 are required to address RF exposure compliance in accordance with Section 15.247(b)(4). EUT Device is equipped with Metal shielding to cover RF section. Refer to external and internal photos All inputs to the modules are buffered through logic or microprocessor inputs. Internal 1.8V and 2.8V regulator Antenna on the module insert to mother board Device is tested in a test fixture in a standalone configuration FCC ID label format will be included in the filling. System ID label will by displayed on the host system Refer to “User Manual” Exhibit MPE calculation is provided to demonstrate RF compliance for mobile modular approval. Signed: Name: Royce Wang Title: Product Certification Director Date: March 10, 2011

Cover Letter(s)

内部公开 内部公开内部公开 内部公开▲ 本文中的所有信息归中兴通讯股份有限公司所有,未经允许,不得外传 第 1 / 1 页 ZTE CORPORATION ZTE Plaza, Keji Road South, Hi-Tech Industrial Park,Nanshan District,Shenzhen, Guangdong, 518057, P.R.China Date: Oct 12,2009 To: Federal Communications Commission, Authorization & Evaluation Division, 7435 Oakland Mills Road, Columbia, MD 21046 And American Telecommunications Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 To Whom It May Concern: TMC(Telecommunication Metrology Center of MII) is authorized to act on our behalf, until otherwise notified, for applications to American Telecommunications Certification Body, Inc. (ATCB). We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pur suant to Section 5301 of the Anti-Drug Abuse Act of 1988, U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b) to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you. Regards, Royce Wang ZTE CORPORATION Tel:0755-26770345 Fa x:0755-26770347 E- Mail:[email protected]

Cover Letter(s)

内部公开▲ 本文所有信息为中兴通讯股份有限公司内部信息,未经允许,不得外传 第1页,共1页 ZTE CORPORATION ZTE Plaza, Keji Road South, Hi-Tech Industrial Park, Nanshan District, Shenzhen, Guangdong, 518057, P.R.China Date: March 10, 2011 Federal Communications Commission Office of Engineering and Technology Equipment Authorization Division 7345 Oakland Mills Road Columbia, Maryland 21046 Subject: Permanent Confidentiality request for FCC ID: Q78-MF226 To Whom It May Concern, Pursuant to sections 0.457 and 0.459 of CFR 47, the applicant requests permanent confidential treatment of the following information accompanying this application: - Block Diagram - Schematics - Operational Description - BOM list/Tune-Up-Procedure The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. Sincerely yours, Royce Wang ZTE CORPORATION Tel: 0755-26770345 Fax: 0755-26770347 E-Mail: [email protected]

Cover Letter(s)

内部公开Internal Use Only▲ <以上所有信息均为中兴通讯股份有限公司所有,不得外传> All Rights reserved, No Spreading abroad without Permission of ZTE 第1页 ZTE CORPOARTION 2011-3-10 Fed eral Communications Commission Office of Engineering and Technology Equipment Authorization Division 7345 Oakland Mills Road Columbia, Maryland 21046 Subject: SHORT-TERM Confidentiality request for FCC ID: Q78-MF2 26 To Whom It May Concern, Pursuant to sections 0.457 and 0.459 of CFR 47 and to avoid premature release of sensitive information prior to marketing or release of the product to the public, the applicant requests the following documents contained in this certification application be temporarily withheld from public disclosure for an initial period of 45 days:  External Photos  Internal Photos  Test Setup Photos  User’s Manual The applicant also acknowledges that they will also provide appropriate notice to ACB should either of the following occur: a) if the applicant requires additional 45 day extension periods they will notify ACB with a new request letter at least 7 days prior to the short-term confidentiality expiration date - [Note: up to a maximum of 3 extensions only are allowed], or b) immediately notify ACB in the event the information regarding the product or the product is made available to the public. ACB will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04 -1705. Sincerely, Royce Wang CERTIFICATION MANAGER ZTE CORPORATION

External Photos

External Photo

ID Label/Location Info

Q78-MF226 Label Location: The label is permanent on the shielding of the device.

Internal Photos

Internal Photos

RF Exposure Info

RF exposure requirements – ZTE MF226 Dear Reviewer, The maximum measured power output is GSM 850:33.41dBm GSM 1900:30.68dBm WCDMA850: 23.96dBm WCDMA 1900: 23.90dBm the maximum antenna gain for integral antenna is GSM 850: 1.0dBi GSM 1900:2.5dBi WCDMA850: 1.0dBi WCDMA 1900: 2.5dBi The maximum permissible exposure is defined in 47 CFR 1.1310 with 1mW/cm². The Transmitter is using external antennas that operate at 20 cm or more from nearby persons. The maximum permitted level is calculated using the general equation: S = P’ / 4πR² GSM 850: P’ = 33.41dBm+1.0dBi=34.41dBm=2760.6mW GSM1900: P’ = 30.68dBm+ 2.5dBi=33.18dBm=2079.7mW WCDMA850: P’ = 23.96dBm+1.0dBi=24.96dBm=313.3mW WCDMA1900: P’ = 23.90dBm+2.5dBi =26.40dBm=436.5mW R = 20cm π = 3.1416 Solving for S, the power density at 20 cm is GSM 850: 0.549mW/cm² GSM1900: 0.414mW/cm² UMTS850: 0.062mW/cm² UMTS1900: 0.087mW/cm² So the limit is kept. Best Regard. Yin Feng 2011-03-30 Telecommunication Metrology Center of MIIT Shouxiang Science Building, No 51, Xueyuan Road, Haidian District, Beijing, P.R.China 100191

Test Report

TEST REPORT No. 2011TAR102 for ZTE CORPORATION HSPA+ LGA Module Model Name: ZTE-MF226 FCC ID: Q78-MF226 with Hardware Version: MF226-2.0.0 Software Version: BD_MF226V1.0.0B02 Issued Date: Mar 10, 2011 Note: The test results in this test report relate only to the devices specified in this report. This report shall not be reproduced except in full without the written approval of TMC Beijing. Test Laboratory: DAR accreditation (DIN EN ISO/IEC 17025): No. DGA-PL-114/01-02 FCC 2.948 Listed: No.733176 IC O.A.T.S listed: No.6629A-1 TMC Beijing, Telecommunication Metrology Center of Ministry of Industry and Information Technology 3/F Shou Xiang Technology Building, No.51 Xueyuan Road, Hai Dian District, Beijing, P. R. China,100191. Tel:+86(0)10-62304633-2604, Fax:+86(0)10-62304793, Email:[email protected], web: www.emcite.com No.2011TAR102 Page2 of 74 CONTENTS 1. TEST LABORATORY ......................................................................................................................... 3 1.1. TESTING LOCATION .................................................................................................................... 3 1.2. TESTING ENVIRONMENT ........................................................................................................... 3 1.3. PROJECT DATA .............................................................................................................................. 3 1.4. SIGNATURE ..................................................................................................................................... 3 2. CLIENT INFORMATION ................................................................................................................... 4 2.1. APPLICANT INFORMATION ....................................................................................................... 4 2.2. MANUFACTURER INFORMATION ............................................................................................ 4 3. EQUIPMENT UNDER TEST (EUT) AND ANCILLARY EQUIPMENT (AE) ............................. 5 3.1. ABOUT EUT ..................................................................................................................................... 5 3.2. INTERNAL IDENTIFICATION OF EUT USED DURING THE TEST .................................... 5 3.3. GENERAL DESCRIPTION ............................................................................................................ 5 4. REFERENCE DOCUMENTS ............................................................................................................. 6 4.1. REFERENCE DOCUMENTS FOR TESTING ............................................................................. 6 5. LABORATORY ENVIRONMENT ..................................................................................................... 7 6. SUMMARY OF TEST RESULTS ....................................................................................................... 8 7. TEST EQUIPMENTS UTILIZED ...................................................................................................... 9 A.1 OUTPUT POWER (§22.913(A)/§24.232(B)) ............................................................................... 10 A.2 EMISSION LIMT (§2.1051/§22.917§24.238) ............................................................................. 17 A.3 FREQUENCY STABILITY (§2.1055/§24.235) ........................................................................... 22 A.4 OCCUPIED BANDWIDTH (§2.1049(H)(I)) ................................................................................. 24 A.5 EMISSION BANDWIDTH (§22.917(B)/§24.238(B)) .................................................................. 36 A.6 BAND EDGE COMPLIANCE (§22.917(B)/§24.238(B)) ............................................................. 48 A.7 CONDUCTED SPURIOUS EMISSION (§2.1057/§22.917/§24.238) ............................................... 54 No.2011TAR102 Page3 of 74 1. Test Laboratory 1.1. Testing Location Company Name: TMC Beijing, Telecommunication Metrology Center of MIIT Address: 3/F Shou Xiang Technology Building, No.51 Xueyuan Road, Hai Dian District, Beijing, P. R. China Postal Code: 100191 Telephone: 00861062304633 Fax: 00861062304793 1.2. Testing Environment Normal Temperature: 15-35°C Relative Humidity: 20-75% 1.3. Project data Testing Start Date: Feb 20, 2011 Testing End Date: Mar 10, 2011 1.4. Signature Zi Xiaogang (Prepared this test report) Sun Xiangqian (Reviewed this test report) Lu Bingsong Deputy Director of the laboratory (Approved this test report) No.2011TAR102 Page4 of 74 2. Client Information 2.1. Applicant Information Company Name: ZTE CORPORATION Address /Post: ZTE Plaza, Keji Road South, Hi-Tech Industrial Park, Nanshan District, Shenzhen, Guangdong, 518057, P.R.China City: Shenzhen Postal Code: 518057 Country: China Telephone: 0086 21 68895196 Fax: 0086 21 61460600 2.2. Manufacturer Information Company Name: ZTE CORPORATION Address /Post: ZTE Plaza, Keji Road South, Hi-Tech Industrial Park, Nanshan District, Shenzhen, Guangdong, 518057, P.R.China City: Shenzhen Postal Code: 518057 Country: China Telephone: 0086 21 68895196 Fax: 0086 21 61460600 No.2011TAR102 Page5 of 74 3. Equipment Under Test (EUT) and Ancillary Equipment (AE) 3.1. About EUT Description HSPA+ LGA Module Model Name ZTE- MF226 FCC ID Q78-MF226 Frequency GSM 850MHz; PCS 1900MHz; WCDMA Band II; WCDMA Band V Antenna Internal Output power 27.11 dBm maximum EIRP measured for GSM1900 Extreme vol. Limits 3.4VDC to 4.2VDC (nominal: 3.8VDC) Extreme temp. Tolerance -30°C to +50°C Note: Components list, please refer to documents of the manufacturer; it is also included in the original test record of Telecommunication Metrology Center of MIIT of People’s Republic of China. 3.2. Internal Identification of EUT used during the test EUT ID* SN or IMEI HW Version SW Version N07 255320500027 MF226-2.0.0 BD_MF226V1.0.0B02 N15 255320500015 MF226-2.0.0 BD_MF226V1.0.0B02 *EUT ID: is used to ide…

Text truncated - open the document above for the full version.

Test Report

TEST REPORT No. 2011TAR103 for ZTE CORPORATION HSPA+ LGA Module Model Name: ZTE-MF226 FCC ID : Q78-MF226 with Hardware Version: MF226-2.0.0 Software Version: BD_MF226V1.0.0B02 Issued Date: Mar 10, 2011 Note: The test results in this test report relate only to the devices specified in this report. This report shall not be reproduced except in full without the written approval of TMC Beijing. Test Laboratory: DAR accreditation (DIN EN ISO/IEC 17025): No. DGA-PL-114/01-02 FCC 2.948 Listed: No.733176 IC O.A.T.S listed: No.6629A-1 TMC Beijing, Telecommunication Metrology Center of Ministry of Industry and Information Technology 3/F Shou Xiang Technology Building, No.51 Xueyuan Road, Hai Dian District, Beijing, P. R. China,100191. Tel:+86(0)10-62304633-2604, Fax:+86(0)10-62304793, Email:[email protected], web: www.emcite.com No.2011TAR103 Page2 of 51 CONTENTS 1. TEST LABORATORY ......................................................................................................................... 3 1.1. TESTING LOCATION .................................................................................................................... 3 1.2. TESTING ENVIRONMENT ........................................................................................................... 3 1.3. PROJECT DATA .............................................................................................................................. 3 1.4. SIGNATURE ..................................................................................................................................... 3 2. CLIENT INFORMATION ................................................................................................................... 4 2.1. APPLICANT INFORMATION ....................................................................................................... 4 2.2. MANUFACTURER INFORMATION ............................................................................................ 4 3. EQUIPMENT UNDER TEST (EUT) AND ANCILLARY EQUIPMENT (AE) ............................. 5 3.1. ABOUT EUT ..................................................................................................................................... 5 3.2. INTERNAL IDENTIFICATION OF EUT USED DURING THE TEST .................................... 5 3.3. GENERAL DESCRIPTION ............................................................................................................ 5 4. REFERENCE DOCUMENTS ............................................................................................................. 6 4.1. REFERENCE DOCUMENTS FOR TESTING ............................................................................. 6 5. LABORATORY ENVIRONMENT ..................................................................................................... 7 6. SUMMARY OF TEST RESULTS ....................................................................................................... 8 7. TEST EQUIPMENTS UTILIZED ...................................................................................................... 9 ANNEX A: MEASUREMENT RESULTS ................................................................................................ 10 A.1 OUTPUT POWER (§22.913(A)/§24.232(B)) ............................................................................... 10 A.2 EMISSION LIMT (§2.1051/§22.917/§24.238) ............................................................................ 14 A.3 FREQUENCY STABILITY (§2.1055/§24.235) ........................................................................... 19 A.4 OCCUPIED BANDWIDTH (§2.1049(H)(I)) ............................................................................... 21 A.5 EMISSION BANDWIDTH (§22.917(B)/§24.238(B))................................................................ 25 A.6 BAND EDGE COMPLIANCE (§22.917(B)/§24.238(B)) .......................................................... 29 A.7 CONDUCTED SPURIOUS EMISSION (§2.1057/§22.917/§24.238) ............................................. 31 No.2011TAR103 Page3 of 51 1. Test Laboratory 1.1. Testing Location Company Name: TMC Beijing, Telecommunication Metrology Center of MIIT Address: 3/F Shou Xiang Technology Building, No.51 Xueyuan Road, Hai Dian District, Beijing, P. R. China Postal Code: 100191 Telephone: 00861062304633 Fax: 00861062304793 1.2. Testing Environment Normal Temperature: 15-35°C Relative Humidity: 20-75% 1.3. Project data Testing Start Date: Feb 20, 2011 Testing End Date: Mar 10, 2011 1.4. Signature Zi Xiaogang (Prepared this test report) Sun Xiangqian (Reviewed this test report) Lu Bingsong Deputy Director of the laboratory (Approved this test report) No.2011TAR103 Page4 of 51 2. Client Information 2.1. Applicant Information Company Name: ZTE CORPORATION Address /Post: ZTE Plaza, Keji Road South, Hi-Tech Industrial Park, Nanshan District, Shenzhen, Guangdong, 518057, P.R.China City: Shenzhen Postal Code: 518057 Country: China Telephone: 0086 21 68895196 Fax: 0086 21 61460600 2.2. Manufacturer Information Company Name: ZTE CORPORATION Address /Post: ZTE Plaza, Keji Road South, Hi-Tech Industrial Park, Nanshan District, Shenzhen, Guangdong, 518057, P.R.China City: Shenzhen Postal Code: 518057 Country: China Telephone: 0086 21 68895196 Fax: 0086 21 61460600 No.2011TAR103 Page5 of 51 3. Equipment Under Test (EUT) and Ancillary Equipment (AE) 3.1. About EUT Description HSPA+ LGA Module Model Name ZTE-MF226 FCC ID Q78-MF226 Frequency GSM 850MHz; PCS 1900MHz; WCDMA Band II; WCDMA Band V Antenna Internal Output power 20.81 dBm maximum EIRP measured for WCDMA Band II Extreme vol. Limits 3.4VDC to 4.2VDC (nominal: 3.8VDC) Extreme temp. Tolerance -30°C to +50°C Note: Components list, please refer to documents of the manufacturer; it is also included in the original test record of Telecommunication Metrology Center of MIIT of People’s Republic of China. 3.2. Internal Identification of EUT used during the test EUT ID* SN or IMEI HW Version SW …

Text truncated - open the document above for the full version.

Contact Information

Applicant

Cary Kong(Product Certification Manager)
[email protected]0086-755-26777740Fax: 0086-755-26770347

Technical Contact

TMC, Telecommunication Metrology Center of MIITXue Zhen
[email protected]+86-10-62304633

No. 52, Huayuan Bei Road, Haidian District, · Beijing · China

Test Firm

TMC-Telecommunication Metrology Center of M.I.I.TChongwen Song
[email protected]0086-10-62303288Fax: 0086-10-62304793

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
622H826.4 MHz - 846.6 MHz245.00 mW4M13F9W0.1 ppm
Modular Type
Single Modular Approval
Confidentiality
Long Term
Grant Notes
Single Modular Approval. Power out is conducted at the antenna terminal. ERP for part 22 is 0.331 W and EIRP for part 24 is 0.514 W using the specific antenna as shown within this application. This device is to be used only for mobile and fixed application. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC muti-transmitter product procedures. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. OEM integrators must insure that the end user has no manual instructions to remove or install this module. For mobile and fixed operating configurations the antenna gain, including cable loss, must not exceed the requirements defined in 2.1091 for satisfying RF exposure compliance.

Other Applications from ZTE Corporation

Home Gateway - FCC ID Q78-E1320 - ZTE Corporation
Q78-E1320

Home Gateway

Oct 06, 2022

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Home Gateway - FCC ID Q78-E3330 - ZTE Corporation
Q78-E3330

Home Gateway

Sep 21, 2022

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
RichMedia Box - FCC ID Q78-ZXV10B866V2 - ZTE Corporation
Q78-ZXV10B866V2

RichMedia Box

May 23, 2021

Equipment Class

DTS - Digital Transmission System
Home Gateway - FCC ID Q78-ZXHNH298Q - ZTE Corporation
Q78-ZXHNH298Q

Home Gateway

Apr 22, 2021

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Home Gateway - FCC ID Q78-ZXHNH196Q - ZTE Corporation
Q78-ZXHNH196Q

Home Gateway

Apr 19, 2021

Equipment Class

NII - Unlicensed National Information Infrastructure TX