Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Date of Grant
Jan 02, 2013
Application Purpose
Original Equipment
Date of Application
Jan 02, 2013
Equipment Note
ZXSDR RSU82 S8500 is RSU Macro Radio Remote Unit
Frequency Range
869.00000000 - 894.00000000
Company
ZTE Corporation
Country
China

Documents & Files

Select a file to view

Users Manual

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

RSU82 UserManual HardwareVersion:HV2.0 ZTECORPORATION NO.55,Hi-techRoadSouth,ShenZhen,P.R.China Postcode:518057 Tel:+86-755-26771900 Fax:+86-755-26770801 URL:http://ensupport.zte.com.cn E-mail:[email protected] LEGALINFORMATION Copyright©2012ZTECORPORATION. Thecontentsofthisdocumentareprotectedbycopyrightlawsandinternationaltreaties.Anyreproductionor distributionofthisdocumentoranyportionofthisdocument,inanyformbyanymeans,withoutthepriorwritten consentofZTECORPORATIONisprohibited.Additionally,thecontentsofthisdocumentareprotectedby contractualconfidentialityobligations. Allcompany,brandandproductnamesaretradeorservicemarks,orregisteredtradeorservicemarks,ofZTE CORPORATIONoroftheirrespectiveowners. Thisdocumentisprovided“asis”,andallexpress,implied,orstatutorywarranties,representationsorconditions aredisclaimed,includingwithoutlimitationanyimpliedwarrantyofmerchantability,fitnessforaparticularpurpose, titleornon-infringement.ZTECORPORATIONanditslicensorsshallnotbeliablefordamagesresultingfromthe useoforrelianceontheinformationcontainedherein. ZTECORPORATIONoritslicensorsmayhavecurrentorpendingintellectualpropertyrightsorapplications coveringthesubjectmatterofthisdocument.ExceptasexpresslyprovidedinanywrittenlicensebetweenZTE CORPORATIONanditslicensee,theuserofthisdocumentshallnotacquireanylicensetothesubjectmatter herein. ZTECORPORATIONreservestherighttoupgradeormaketechnicalchangetothisproductwithoutfurthernotice. UsersmayvisitZTEtechnicalsupportwebsitehttp://ensupport.zte.com.cntoinquirerelatedinformation. TheultimaterighttointerpretthisproductresidesinZTECORPORATION. RevisionHistory RevisionNo.RevisionDateRevisionReason R1.52012–12–20ThefollowingsectionsareaddedtoAboutThisManul: lRelatedDocumentation lConvention R1.42012–11–21TheProductSpecificationsandthetechnicaspecificationshave beenupdated. R1.32012–10–19ThetechnicalSpecificationshavebeenupdated. R1.22012–05–30Modifiedthefollowingsections: l1.1PositionoftheRSU82intheRadioNetwork l1.3ServicesandFunctions l1.4ProductSpecifications l3.1PhysicalSpecifications l3.2RadioPerformanceSpecifications l4.2InstallingaRSU82 SJ-20111021104623-005|2012-12-20(R1.5)ZTEProprietaryandConfidential RevisionNo.RevisionDateRevisionReason R1.12012–01–30l1.1PositionoftheRSU82intheRadioNetwork l1.3ServicesandFunctions l1.4ProductSpecifications l2.1HardwareArchitecture l3.1PhysicalParameters l3.2RadioPerformanceSpecification l4.2InstallingRSU82 R1.02011–11–30Thefirstedition SerialNumber:SJ-20111021104623-005 PublishingDate:2012-12-20(R1.5) Contents AboutThisManual.........................................................................................I Chapter1ProductIntroduction................................................................1-1 1.1PositionoftheRSU82intheRadioNetwork........................................................1-1 1.2ProductAppearance...........................................................................................1-2 1.3ServicesandFunctions...................................................................................... 1-4 1.4ProductSpecifications........................................................................................1-6 1.5ExternalInterfaces.............................................................................................1-7 1.6Indicators...........................................................................................................1-8 Chapter2SystemArchitecture................................................................. 2-1 2.1HardwareArchitecture........................................................................................2-1 2.2SoftwareArchitecture.........................................................................................2-2 Chapter3TechnicalSpecifications.......................................................... 3-1 3.1PhysicalSpecification......................................................................................... 3-1 3.2RadioPerformanceSpecifications....................................................................... 3-2 Chapter4HardwareInstallation................................................................ 4-1 4.1Overview........................................................................................................... 4-1 4.2InstallinganRSU82............................................................................................ 4-1 4.3CablesInstallation.............................................................................................. 4-2 4.3.1InstallingPowerCables............................................................................ 4-2 4.3.2InstallingaMonitoringCable..................................................................... 4-3 4.3.3InstallinganAntennaFeeder.....................................................................4-4 4.3.4InstallinganSFPHigh-SpeedCable..........................................................4-6 Chapter5InternationalAuthentication....................................................5-1 Figures.............................................................................................................I Tables............................................................................................................III Index...............................................................................................................V Glossary.......................................................................................................VII I SJ-20111021104623-005|2012-12-20(R1.5)ZTEProprietaryandConfidential II SJ-20111021104623-005|2012-12-20(R1.5)ZTEProprietaryandConfidential AboutThisManual Warning! Changesormodificationstothisunitnotexpresslyapprovedbythepartyresponsiblefor compliancecouldvoidtheuser’sauthoritytooperatetheequipment. Purpose ThismanualprovidesinformationabouttheRSU82,includingtheproductintroduction, systemprinciple,technicalspecifications,andhardwareinstallation. IntendedAudience Thismanualisapplicabletoallpersonnelwhoworkwi…

Text truncated - open the document above for the full version.

Users Manual

PersonalHealthandSafetyInformation ZTECORPORATION NO.55,Hi-techRoadSouth,ShenZhen,P.R.China Postcode:518057 Tel:+86-755-26771900 Fax:+86-755-26770801 URL:http://ensupport.zte.com.cn E-mail:[email protected] LEGALINFORMATION Copyright©2011ZTECORPORATION. Thecontentsofthisdocumentareprotectedbycopyrightlawsandinternationaltreaties.Anyreproductionor distributionofthisdocumentoranyportionofthisdocument,inanyformbyanymeans,withoutthepriorwritten consentofZTECORPORATIONisprohibited.Additionally,thecontentsofthisdocumentareprotectedby contractualconfidentialityobligations. Allcompany,brandandproductnamesaretradeorservicemarks,orregisteredtradeorservicemarks,ofZTE CORPORATIONoroftheirrespectiveowners. Thisdocumentisprovided“asis”,andallexpress,implied,orstatutorywarranties,representationsorconditions aredisclaimed,includingwithoutlimitationanyimpliedwarrantyofmerchantability,fitnessforaparticularpurpose, titleornon-infringement.ZTECORPORATIONanditslicensorsshallnotbeliablefordamagesresultingfromthe useoforrelianceontheinformationcontainedherein. ZTECORPORATIONoritslicensorsmayhavecurrentorpendingintellectualpropertyrightsorapplications coveringthesubjectmatterofthisdocument.ExceptasexpresslyprovidedinanywrittenlicensebetweenZTE CORPORATIONanditslicensee,theuserofthisdocumentshallnotacquireanylicensetothesubjectmatter herein. ZTECORPORATIONreservestherighttoupgradeormaketechnicalchangetothisproductwithoutfurthernotice. UsersmayvisitZTEtechnicalsupportwebsitehttp://ensupport.zte.com.cntoinquirerelatedinformation. TheultimaterighttointerpretthisproductresidesinZTECORPORATION. RevisionHistory RevisionNo.RevisionDateRevisionReason R1.02011–01–06FirstEdition SerialNumber:SJ-20101118085446-001 PublishingDate:2011–01–06(R1.0) Contents Preface.............................................................................................................I Chapter1HazardSymbols........................................................................1-1 1.1HazardSymbolsillustrations...............................................................................1-1 Chapter2GeneralSafetyPrecautions..................................................... 2-1 Chapter3ElectricShockHazards............................................................ 3-1 Chapter4EnergyHazards......................................................................... 4-1 Chapter5FireHazard................................................................................ 5-1 5.1GeneralFirePrecautions....................................................................................5-1 Chapter6HeatHazards.............................................................................6-1 Chapter7MechanicalHazards..................................................................7-1 Chapter8LaserHazards........................................................................... 8-1 Chapter9RFExposureHazards...............................................................9-1 9.1RFSafetyforInstallationandMaintenancePersonnel..........................................9-1 Chapter10OtherHazards....................................................................... 10-1 10.1HoistingHeavyObjects................................................................................... 10-1 10.1.1GeneralInformation.............................................................................. 10-1 10.1.2CraneandRiggingOperations.............................................................. 10-1 10.2WorkingatHeight........................................................................................... 10-2 10.3Batteries........................................................................................................ 10-2 Glossary..........................................................................................................I I II Preface Purpose Thisdocumentdescribesthepersonalhealthandsafetyinformationthatapplieswhen workingwithZTEsystemproducts.Theinstructionscontainedhereinaremandatoryto ensurepersonalsafetywhenworkingwithZTEsystemproducts. Note: Theinformationcontainedhereinmustbereadcarefullybeforeworkingtominimizethe riskofpersonalinjury.Foranypersonalsafetyquestions,askyoursupervisororcontact yourlocalZTEofficeforadvice. TargetGroup ThisdocumentisdesignedforthosewhoworkorsupervisewithZTEproductsin engineering,installation,commissioning,andmaintenance.Allthesepersonsshould fullyunderstandthesafetyinstructionsandothersafetyinformationcontainedhereinto minimizepersonalinjuries. Scope TheinformationcontainedhereinappliestoallZTEproducts.Usersmustclearly understandthepotentialriskswhenworkingwithZTEproducts,andknowwhichpartof thisdocumentcanbeusedtodealwiththeserisks. LocalLawsandRegulations AnyworkrelatingtoZTEsystemproductsissubjecttolocallawsandregulations.Ifthere arenoapplicablelocallawsorregulations,theinformationcontainedhereinshouldbe followed. EducationalRequirements AccordingtothesafetyinstructionsinZTEusermanualsorotherdocuments,all personnelwhoworkwithZTEproductsmusthavethenecessaryeducation,training,and competencerequiredtoworkcorrectly.Forcertainwork,specialtrainingorcertification mayberequired,forexample,ZTEcertification. FirstAid Firstaidkitsmustbestoredindesignatedplacesinbuildingsandvehicles,withtheir locationsprominentlymarked.Asuitablenumberofpeopleshouldbetrainedasfirst aiders.Thenamesoftrainedfirstaidersmustbeprominentlyshown. I II Chapter1 HazardSymbols ThischapterdescribesthehazardsymbolsusedinZTEmanuals.Hazardsymbolsare classifiedintothreelevels,danger,warning,andcaution,whichareusedtoindicate differenthazards. TableofContents HazardSymbolsillustrations...................................................................................... 1-1 1.1HazardSymbolsillustrations Table1-1listsandexplainshazardsymbols. Table1-1HazardSymbols HazardSymbolMeaning HazardSymbol:Generalsafetyprecautions. Danger:Indicatesanimminenthazardthat,ifnot avoided,couldresultindeathorseriousinjury. Warning:Indicatesahazardthat,ifnotavoided, couldresulti…

Text truncated - open the document above for the full version.

Cover Letter(s)

SU82S8500 ZTE Corporation ZTE Plaza, Hi-Tech, Industrial Park, Nanshan District, Shenzhen, Guangdong, P.R. China FCC Confidential Authorization Date: 2012-12-11 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Confidentiality Request regarding application for certification of FCC ID: Q78-R Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: • Detailed Circuit Schematics --- (Long term)  Block Diagram--- (Long term)  Part list--- (Long term)  Tune-up procedure--- (Long term) The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely Yours, Signature: Typed or Printed Name: Zhihui,Wang Title: Certification Director Company Name: ZTE Corporation

Cover Letter(s)

RSU82S8500 1211 e-mail:[email protected] Phone: +86-755-26777740 COMPANY LETTERHEAD Date (//2012) BABT TCB Balfour House, Churchfield Road, Walton-on-Thames, Surrey, KT12 2TD Dear Sir or Madam, We, ZTE Corporation. ZTE Plaza, Keji Road South, Hi-Tech Industrial Park, NanShan District, 518057 Shenzhen, P.R.CHINA hereby authorize TUV-SUD China Shenzhen Branch 6/F, H Hall, Century Craftwork Culture Square, No. 4001 Fuqiang Road, Futian District, Shenzhen 518048 P. R. China Louis Lin Phone: +86-755-88286998 e-mail: [email protected] to act as our agent in all matters relating to applications for equipment authorization, including the signing of all documents relating to these matters. We also hereby certify that neither we nor any party to this application are subject to denial of U.S. Federal benefits, which include FCC benefits, pursuant to section 5301 of Anti-Drug Abuse Act of 1988, U.S.C. 862 because of conviction for possession or distribution of controlled substance. This authorization is application to following FCC ID application: FCC ID: Q78- Sincerely, For and Behalf of: ZTE Corporation. Royce Wang Manager ZTE

Cover Letter(s)

COMPANY LETTERHEAD Date (12/12/2012) BABT TCB Balfour House, Churchfield Road, Walton-on-Thames, Surrey, KT12 2TD Dear Sir or Madam, We, ZTE Corporation ZTE Plaza, Hi-Tech, Industrial Park, Nanshan District, Shenzhen, Guangdong, P.R. China hereby declared Macro Radio Remote Unit, ZXSDR RSU82 S8500’s RF parameters can been altered through software, but no third parties except manufacture ZTE can modify, configure, or load different software, or make configuration setting to operate the device or host hardware radio frequency parameters(frequency range, modulation type, maximum output power or other radio parameters) in any other way granted( or expected to be granted), also this device is not capable of operating in any other way than granted. So manufacture ZTE elect ZXSDR RSU82 S8500 (FCC ID: Q780-RSU82S8500) as non SDRs (Software Defined Radio) in FCC certification. Sincerely, For and Behalf of: ZTE Corporation Typed or Printed Name: Zhihui,Wang Title: Certification Director

External Photos

内部公开Internal Use Only▲ <以上所有信息均为中兴通讯股份有限公司所有,不得外传> All Rights reserved, No Spreading abroad without Permission of ZTE 第1页 内部公开Internal Use Only▲ <以上所有信息均为中兴通讯股份有限公司所有,不得外传> All Rights reserved, No Spreading abroad without Permission of ZTE 第2页

ID Label/Location Info

内部公开Internal Use Only▲ <以上所有信息均为中兴通讯股份有限公司所有,不得外传> All Rights reserved, No Spreading abroad without Permission of ZTE 第1页

Internal Photos

内部公开Internal Use Only▲ <以上所有信息均为中兴通讯股份有限公司所有,不得外传> All Rights reserved, No Spreading abroad without Permission of ZTE 第1页 内部公开Internal Use Only▲ <以上所有信息均为中兴通讯股份有限公司所有,不得外传> All Rights reserved, No Spreading abroad without Permission of ZTE 第2页 内部公开Internal Use Only▲ <以上所有信息均为中兴通讯股份有限公司所有,不得外传> All Rights reserved, No Spreading abroad without Permission of ZTE 第3页 内部公开Internal Use Only▲ <以上所有信息均为中兴通讯股份有限公司所有,不得外传> All Rights reserved, No Spreading abroad without Permission of ZTE 第4页

Test Report

ZTE Corporation FCC ID: Q78-RSU82S8500 Report #FCC-2011-085 FCC PART 22 TYPE APPROVAL Report 1 of 198 FCC MEASUREMENT AND TEST REPORT For ZTE Corporation ZTE Plaza, Hi-tech Park, Nanshan District, Shenzhen, Guangdong, China 518057 FCC ID: Q78- RSU82S8500 Nov 15, 2012 This Report Concerns: Original Report Equipment Type: RSU Macro Radio Remote Unit Test Engineer: Bloom Report No.: FCC-2011-085 Test Date: Sep 25 – Nov 10, 2012 Reviewed By: Xie Yuming Prepared By: ZTE Corporation. ZTE Plaza, Hi-tech Park, Nanshan District, Shenzhen, Guangdong, China 518057, P.R.China Tel: +86-755-26770000 Fax: +86-755-26771999 Note: The test report is specially limited to the above company and this particular sample only. It may not be duplicated without prior written consent of ZTE Corporation. This report must not be used by the client to claim product certification ,approval ,or endorsement by any agency of the US Government. ZTE Corporation FCC ID: Q78-RSU82S8500 Report #FCC-2011-085 FCC PART 22 TYPE APPROVAL Report 2 of 198 TABLE OF CONTENTS TABLE OF CONTENTS .................................................................................................................................................... 2 1 GENERAL INFORMATION ....................................................................................................................................... 7 Product Description for Equipment Under Test (EUT) .......................................................................................... 7 Objective ...................................................................................................................................................................... 8 Related Submittal(s)/Grant(s) ................................................................................................................................... 8 Test Methodology ....................................................................................................................................................... 8 Test Facility .................................................................................................................................................................. 8 2 SYSTEM TEST CONFIGURATION ......................................................................................................................... 9 Description of Test Configuration ............................................................................................................................. 9 3 CDMA OF TEST RESULTS .................................................................................................................................... 10 3.1 TRANSMITTER OUTPUT POWER ........................................................................................................................ 11 Applicable Standard:FCC §2.1046 §22.913 ...................................................................................................... 11 Test Equipment List and Details ............................................................................................................................. 11 Test Procedure .......................................................................................................................................................... 11 Environmental Conditions ....................................................................................................................................... 11 Test Result: Pass ...................................................................................................................................................... 12 Test Mode: Transmitting CDMA ............................................................................................................................. 12 Test Data: ................................................................................................................................................................... 12 3.2 RF EXPOSURE ......................................................................................................................................................... 20 Applicable standard: FCC §2.1091 §1.1037 ........................................................................................................ 20 Limit ............................................................................................................................................................................ 20 Test Data .................................................................................................................................................................... 20 Test Result: pass .......................................................................................................................................................... 20 3.3 MODULATION CHARACTERISTIC........................................................................................................................ 21 Applicable Standard: FCC §2.1047 .................................................................................................................... 21 Test Equipment List and Details ............................................................................................................................. 21 Test Procedure .......................................................................................................................................................... 21 Test Data Environmental Conditions ..................................................................................................................... 21 Test Result: Pass ...................................................................................................................................................... 21 Test Mode: Transmitting CDMA ............................................................................................................................. 21 Test Data: ..................…

Text truncated - open the document above for the full version.

Test Report

ZTE Corporation FCC ID: Q78-RSU82S8500 Report #FCC-2011-085 FCC PART 22 TYPE APPROVAL Report 100 4.7 BAND EDGES Applicable Standard: FCC §2.1051 According to §2.1051, the power of any emission outside of the authorized operating frequency ranges must be attenuated below the transmitting power (p) by a factor of at least 43 + 10 log (p) dB. The limit (dBm) should < P –(43+10log(P)) = -13dBm. Test Equipment List and Details Manufacturer Description Model Serial Number Calibration Date Calibration Due Date Agilent MXA Series Spectrum Analyzer N9020A MY48011941 2011-4-8 2012-4-7 Atten 40dB Attenuator ATSI150-4-40 11300100204204 2011-7-11 2012-7-11 Forstar Forstar RF Cable 002 1034 2011-4-8 2012-4-7 *statement of traceability: ZTE Corporation Reliability Testing Center attest that all calibration have been performed per the NVLAP requirements , traceable to NIST. Test Procedure The RF output of the transmitter was connected to the input of the spectrum analyzer through sufficient attenuation. The center of the spectrum analyzer was set to block edge frequency. Test Data Environmental Conditions Temperature: 20 °C Relative Humidity: 53% ATM Pressure: 1009mbar ZTE Corporation FCC ID: Q78-RSU82S8500 Report #FCC-2011-085 FCC PART 22 TYPE APPROVAL Report 101 Test Result: Pass Test Mode: Transmitting UMTS Test Data For four carriers Frequency channel Max bandedge Emission (dBm) Limit (dBm) 871.6/876.6/881.6/886.6 -25.090 -13.00 876.4/881.4/886.4/891.4 -26.703 -13.00 ZTE Corporation FCC ID: Q78-RSU82S8500 Report #FCC-2011-085 FCC PART 22 TYPE APPROVAL Report 102 For three carriers Frequency channel Max bandedge Emission (dBm) Limit (dBm) 871.6/876.6/881.6 -25.067 -13.00 876.4/881.4/886.4 -26.906 -13.00 ZTE Corporation FCC ID: Q78-RSU82S8500 Report #FCC-2011-085 FCC PART 22 TYPE APPROVAL Report 103 ZTE Corporation FCC ID: Q78-RSU82S8500 Report #FCC-2011-085 FCC PART 22 TYPE APPROVAL Report 104 For two carriers Frequency channel Max bandedge Emission (dBm) Limit (dBm) 871.6/876.6 -25.298 -13.00 886.4/891.4 -25.664 -13.00 ZTE Corporation FCC ID: Q78-RSU82S8500 Report #FCC-2011-085 FCC PART 22 TYPE APPROVAL Report 105 For One carrier Frequency channel Max bandedge Emission (dBm) Limit (dBm) 871.6 -27.871 -13.00 891.4 -27.417 -13.00 ZTE Corporation FCC ID: Q78-RSU82S8500 Report #FCC-2011-085 FCC PART 22 TYPE APPROVAL Report 106 ZTE Corporation FCC ID: Q78-RSU82S8500 Report #FCC-2011-085 FCC PART 22 TYPE APPROVAL Report 107 4.8 FREQUENCY STABILITY Applicable Standard: FCC § 2.1055, § 22.355 Requirements: FCC § 2.1055 (a)(d), The frequency stability shall be sufficient to ensure that the fundamental emissions stay within the authorized bands of operation. Test Equipment List and Details Manufacturer Description Model Serial Number Calibration Date Calibration Due Date GZ-ESPEC Temperature Chamber EW0470 06113028 2011-1-26 2012-1-26 Agilent MXA Series Spectrum Analyzer N9020A MY48011941 2011-4-8 2012-4-7 Atten 40dB Attenuator ATSI150-4-40 11300100204204 2011-7-11 2012-7-11 Forstar Forstar RF Cable 002 1034 2011-4-8 2012-4-7 *statement of traceability: ZTE Corporation Reliability Testing Center attest that all calibration have been performed per the NVLAP requirements, traceable to NIST. Test Procedure Frequency Stability vs. Temperature: The equipment under test was connected to an external DC power supply and the RF output was connected to a Spectrum Analyzer via feed-through attenuators. The EUT was placed inside the temperature chamber. The DC leads and RF output cable exited the chamber through an opening made for the purpose. After the temperature stabilized for approximately 150 minutes, the frequency output was recorded from the counter. Frequency Stability vs. Voltage: An external variable DC power supply Source. The voltage was set to 115% of the nominal value and was then decreased until the transmitter light no longer illuminated; i.e., the end point. The output frequency was recorded for each voltage. Environmental Conditions ZTE Corporation FCC ID: Q78-RSU82S8500 Report #FCC-2011-085 FCC PART 22 TYPE APPROVAL Report 108 Normal condition: 25° C Relative Humidity: 54% ATM Pressure: 1011 mbar Test Result: Pass Test Mode: Transmitting UMTS Test Data Frequency Stability Versus Temperature Frequency Stability vs Temperature Temperature (°C) Power Supplied (V dc) Frequency Measure Error ( Hz) Error ( ppm) Limit ( ppm) Result B(871.6MHz) -40 -48 3.8 0.0044 0.02 PASS -30 -48 -2.6 -0.0029 0.02 PASS -20 -48 -4.4 -0.0051 0.02 PASS -10 -48 2.8 0.0032 0.02 PASS 0 -48 -3.6 -0.0041 0.02 PASS 10 -48 3.3 0.0038 0.02 PASS 20 -48 3.3 0.0038 0.02 PASS 30 -48 2.8 0.0032 0.02 PASS 40 -48 -1.7 -0.0019 0.02 PASS 50 -48 -4.4 -0.0051 0.02 PASS 55 -48 4.2 0.0048 0.02 PASS M(881.4MHz) -40 -48 3.3 0.0037 0.02 PASS -30 -48 3.3 0.0037 0.02 PASS -20 -48 -2.9 -0.0033 0.02 PASS ZTE Corporation FCC ID: Q78-RSU82S8500 Report #FCC-2011-085 FCC PART 22 TYPE APPROVAL Report 109 -10 -48 4.4 0.0049 0.02 PASS 0 -48 -2.6 -0.0029 0.02 PASS 10 -48 4.6 0.0052 0.02 PASS 20 -48 -2.7 -0.0031 0.02 PASS 30 -48 -3.8 -0.0043 0.02 PASS 40 -48 -3.2 -0.0036 0.02 PASS 50 -48 4.4 0.0049 0.02 PASS 55 -48 4.5 0.0051 0.02 PASS T(891.4MHz) -40 -48 -4.6 -0.0052 0.02 PASS -30 -48 -4.9 -0.0055 0.02 PASS -20 -48 3.2 0.0036 0.02 PASS -10 -48 3.2 0.0036 0.02 PASS 0 -48 2.5 0.0028 0.02 PASS 10 -48 2.9 0.0033 0.02 PASS 20 -48 -2.3 -0.0026 0.02 PASS 30 -48 -2.7 -0.0030 0.02 PASS 40 -48 3.5 0.0039 0.02 PASS 50 -48 4.3 0.0048 0.02 PASS 55 -48 3.2 0.0036 0.02 PASS Frequency Stability Versus Voltage Frequency Stability vs. Voltage VoltageV dc Temperature °C Frequency Measure Error Hz Error ppm Limit ppm Result B(871.6MHz) 40 20 2.6 0.0029 0.02 PASS 44 20 2.7 0.0031 0.02 PASS 47 20 -2.4 -0.0028 0.02 PASS 50 20 -3.9 -0.0045 0.02 PASS 53 20 -4.1 -0.0047 0.02 PASS 56 20 -3.7 -0.0043 0.02 PASS 57 20 -1.7 -0.0019 0.02 PASS M(881.4MHz) 2.4 0.0028 40 20 3.4 0.0039 0.02 PASS ZTE Corporation FCC ID: Q78-RSU82S8500 Report #FCC-2011-085 FCC PART 22 TYPE APPROVAL Report 110 44 20 2…

Text truncated - open the document above for the full version.

Test Setup Photos

内部公开Internal Use Only▲ <以上所有信息均为中兴通讯股份有限公司所有,不得外传> All Rights reserved, No Spreading abroad without Permission of ZTE 第1页

Contact Information

Applicant

Cary Kong(Product Certification Manager)
[email protected]0086-755-26777740Fax: 0086-755-26770347

Test Firm

ZRT EMC Shenzhen LaboratoryBright Xie
[email protected]86-755-26771609Fax: 86-755-26770347

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
1922H869 MHz - 894 MHz79.07 W6M39F9W0.02 ppm
Confidentiality
Long Term
Grant Notes
Output Power listed is conducted. The transmitter has provision for multi carrier and dual mode of operation. The first 4 powers listed are for 4, 3, 2 & 1 carrier CDMA. The 5th to 8th power listed is for 4, 3, 2 & 1 carrier UMTS. The 9th to 20th power listed is for 6, 5, 4, 3, 2 & 1 carrier GSM. The 21st power listed is for 2 GSM + 2 UMTS carrier. The 22nd power listed is for 4 GSM + 1 UMTS carrier. The antenna(s) used for this transmitter must be fixed mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s) including antenna collocating requirements of 1.1307.

Other Applications from ZTE Corporation

Home Gateway - FCC ID Q78-E1320 - ZTE Corporation
Q78-E1320

Home Gateway

Oct 06, 2022

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Home Gateway - FCC ID Q78-E3330 - ZTE Corporation
Q78-E3330

Home Gateway

Sep 21, 2022

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
RichMedia Box - FCC ID Q78-ZXV10B866V2 - ZTE Corporation
Q78-ZXV10B866V2

RichMedia Box

May 23, 2021

Equipment Class

DTS - Digital Transmission System
Home Gateway - FCC ID Q78-ZXHNH298Q - ZTE Corporation
Q78-ZXHNH298Q

Home Gateway

Apr 22, 2021

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Home Gateway - FCC ID Q78-ZXHNH196Q - ZTE Corporation
Q78-ZXHNH196Q

Home Gateway

Apr 19, 2021

Equipment Class

NII - Unlicensed National Information Infrastructure TX