FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. ZTE Corporation/
  3. Q78-ZTEC335

Q78-ZTEC335800MHz CDMA2000 1X Mobile Phone

ZTE Corporation
800MHz CDMA2000 1X Mobile Phone - FCC ID Q78-ZTEC335 - ZTE Corporation
Click to zoom

Application Details

Equipment Class
TNE - Licensed Non-Broadcast Transmitter Held to Ear
Date of Grant
Nov 06, 2007
Application Purpose
Original Equipment
Date of Application
Nov 06, 2007
Equipment Note
800MHz CDMA2000 1X Mobile Phone
Frequency Range
824.70000000 - 848.31000000
Company
ZTE Corporation
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

C335 CDMA 1X Digital Mobile Phone User Manual Copyright © 2007 by ZTE Corporation All rights reserved. No part of this publication may be excerpted, reproduced, translated or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without the prior written permission of ZTE Corporation. The manual is published by ZTE Corporation. We reserve the right to make modifications on print errors or update specifications without prior notice. Version: Release 1.0 Date: Sep 2007 Manual number:0000000000 i Content 1 General Information ....................................................... 1 1.1 Welcome.................................................................................... 1 1.2 Security ..................................................................................... 1 1.3 Safety Warnings .............................................................. 2 1.4 Limit Warranty .......................................................................... 6 1.5 Limitation of Liability............................................................... 7 2 Know Your Phone............................................................ 8 2.1 Keypad ...................................................................................... 8 2.2 Instruction of Interface Icon .................................................... 11 2.3 Technical Parameters............................................................... 11 2.4 Battery..................................................................................... 12 2.4.1 Remove and Installation of Battery ................................. 12 2.4.2 Charging the Battery........................................................ 13 2.5 Connecting to the Network ..................................................... 15 2.5.1 UIM Card ........................................................................ 15 2.5.2 Insertion and Extraction of UIM Card ............................. 15 2.5.3 Power on/off Phone ......................................................... 16 2.5.4 PIN Code......................................................................... 16 2.5.5 Connecting the Network .................................................. 17 ii 3 Basic Operations............................................................ 18 3.1 Making a Call.......................................................................... 18 3.2 Answering a Call ..................................................................... 20 3.2.1 Setting Any Key Answer ................................................. 20 3.2.2 Incoming Call Silence ..................................................... 20 3.3 In Conversation ....................................................................... 21 3.3.1 Silence in Conversation ................................................... 21 3.3.2 Adjusting Volume in Conversation .................................. 21 3.3.3 Selecting Options in Conversation .................................. 21 3.4 Menu Functions...................................................................... 21 4 Names ............................................................................. 23 4.1 Finding Records ...................................................................... 23 4.2 Adding New Record................................................................ 24 4.3 Viewing Records ..................................................................... 26 4.4 Erasing Records ...................................................................... 27 4.4.1 Erasing a Record.............................................................. 27 4.4.2 Erasing All Contacts ........................................................ 27 4.5 Editing Records....................................................................... 28 4.6 Setting Speed Dial................................................................... 28 4.7 Viewing and Making Speed Dial............................................. 29 4.8 Editing Group.......................................................................... 29 4.9 Memory Status ........................................................................ 30 iii 5 Messages......................................................................... 31 5.1 Sending a New Message ......................................................... 31 5.2 Receiving Incoming Call while Editing Message ................... 32 5.3 Reading Message .................................................................... 32 5.4 Viewing OutBox ..................................................................... 33 5.5 Reading Voice Mail................................................................. 33 5.6 Sending Templates Messages .................................................. 34 5.7 Setting Message Groups.......................................................... 34 5.8 Erasing Messages .................................................................... 35 5.8.1 Erasing a Message ........................................................... 35 5.8.2 Erasing All Messages ...................................................... 35 5.9 Message Settings..................................................................... 36 5.9.1 Msg Priority..................................................................... 36 5.9.2 Delivery Acknowledging ................................................. 36 5.9.3 Save Sent Message .......................................................... 36 5.9.4 Automatically Erasing Inbox ........................................... 37 5.9.5 Save Position ................................................................... 37 5.9.6 Memory Status................................................................. 37 6 Call History.................................................................... 39 6.1 Viewing Recent Calls .............................................................. 39 6.2 Erasing Recent Calls List ..........…

Text truncated - open the document above for the full version.

Cover Letter(s)

Add Tel86-755-2677000086-755-2677999 Postcode518057 http// www.zte.com.cn [email protected] Date: 2007-10-30 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Confidentiality Request regarding application for certification of FCC ID: (Q78-ZTEC335) . Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: (Internal Photos, BOM, Technical Specification, Schematics, Block Diagram, Circuit Description, Turn up procedure) The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely Yours, Signature: Typed or Printed Name: Royce Wang Title: Product Certification Director Company Name: ZTE Corporation

Cover Letter(s)

DECLARATION We, ZTE Corporation declare Our company’s project ZTE C336 Is same as ZTE Corporation’s project ZTE C335 Except Hardware: ID Software: ZTC335MRT01 The above-mentioned statements of our company are totally true. If false, we will bear corresponding liability. Company Address: A105, #889, Bibo Rd, Zhangjiang Hi-Tech Park, Shanghai,China Telephone: 86-21-68895196 Fax: 021-50801070 2007-10-31

External Photos

ZTE Corporation FCC ID: Q78-ZTEC335 Page 41 of 46 EXHIBIT C - EUT PHOTOGRAPHS EUT Front View ZTE Corporation FCC ID: Q78-ZTEC335 Page 42 of 46 EUT Rear View

ID Label/Location Info

ZTE Corporation FCC ID: Q78-ZTEC335 Page 38 of 46 EXHIBIT A - FCC ID LABEL INFORMATION Proposed FCC ID Label Proposed Label Location on EUT FCC ID: Q78-ZTEC335

Internal Photos

ZTE Corporation FCC ID: Q78-ZTEC335 Page 43 of 46 EUT Battery off View ZTE Corporation FCC ID: Q78-ZTEC335 Page 44 of 46 EUT Cover off View ZTE Corporation FCC ID: Q78-ZTEC335 Page 45 of 46 EUT Internal View

RF Exposure Info

No.SAR07-061 Page 3 of 10 Contents 1. GENERAL CONDITIONS 2. ADMINISTRATIVE DATA 2.1. Identification of the Responsible Testing Laboratory 2.2. Identification of the Responsible Testing Location(s) 2.3. Organization Item 2.4. Identification of Applicant 2.5. Identification of Manufacture 3. EQUIPMENT UNDER TEST (EUT) 3.1. Identification of the Equipment under Test 3.2. Identification of all used Test Sample of the Equipment under Test This Test Report consists of the following Annexes: Annex A: Accreditation Certificate Annex B: Sample Photographs No.SAR07-061 Page 4 of 10 1.GENERAL CONDITIONS 1.1 This report only refers to the item that has undergone the test. 1.2 This report standalone dose not constitute or imply by its own an approval of the product by the certification Bodies or competent Authorities. 1.3 This document is only valid if complete; no partial reproduction can be made without written approval of Shenzhen Electronic Product Quality Testing Center. 1.4 This report cannot be used partially or in full for publicity and/or promotional purposes without previous written approval of Shenzhen Electronic Product Quality Testing Center and the Accreditation Bodies, if it applies. 2. Administrative Date 2.1. Identification of the Responsible Testing Laboratory Company Name: ShenZhen Electronic Product Quality Testing Center Department: Testing Department Address: Electronic Testing Building, ShaHe Road, NanShan District, ShenZhen, P. R. China Telephone: +86-755-26628676 Fax: +86-755-26627238 Responsible Test Lab Managers: Mr. Wu Li’an 2.2. Identification of the Responsible Testing Location(s) Company Name: ShenZhen Electronic Product Quality Testing Center Address: Electronic Testing Building, ShaHe Road, NanShan District, ShenZhen, P. R. China 2.3. Organization Item S.E.T Report No.: SAR07-061 S.E.T Project Leader: Mr. Li Sixiong S.E.T Responsible for accreditation scope: Mr. Wu Li’an Start of Testing: 2007-10-22 End of Testing: 2007-10-31 2.4. Identification of Applicant Company Name: ZTE CORPORATION Address: ZTE Plaza, Keji Road South, Hi-Tech Industrial Park,Nanshan District,Shenzhen, Guangdong, 518057, P.R.China Contact person: Dang.yingchun Telephone: +86-029-88723843 Fax: +86-029-88723529 2.5. Identification of Manufacture Company Name: ZTE CORPORATION Address: ZTE Plaza, Keji Road South, Hi-Tech Industrial Park,Nanshan District,Shenzhen, Guangdong, 518057, P.R.China Contact person: Dang.yingchun Telephone: +86-029-88723843 Fax: +86-029-88723529 Notes: This data is based on the information by the applicant. No.SAR07-061 Page 6 of 10 3. Equipment Under Test (EUT) 3.1. Identification of the Equipment under Test Brand Name: ZTE 中兴 Ty pe Na me: ZTEC335 Marking Name: ZTEC335 Test frequency CDMA 800MHz Development Stage Identical Prototype Accessories Charger Battery type Li3706T42P3h383857 Battery specification 670 mAh 3.7V Antenna type Build inside Operation mode Call established Modulation mode CDMA General description: Max. Power(ERP) <33dBm for CDMA 800MHz Band NOTE: 1. The EUT is a model of CDMA Mobile Station (“MS” for short in this report) operating in Cellular 800MHz band. 2. The report is issued as an appendix to test report SAR07-061 issued by Shenzhen Electronic Product Quality Testing Center on Oct 31th, 2007. 3. Product Description or Discrepancy between C335 and C336: The Appearance and the color of the models are different, the others are the sameness. The difference doesn’t influence the SAR performance. 4. Please refer to Appendix C for the photographs of the EUT. For a more detailed features description about the EUT, please refer to User’s Manual. 3.2. Identification of all used Test Sample of the Equipment under Test EUT Code ESN Hardware Version Software Version / / CH2B ZTC335MRT01 ANNEX A of ShenZhen Electronic Product Quality Testing Center CONFORMANCE TEST REPORT FOR HUMAN EXPOSURE TO ELECTROMAGNETIC FIELDS SAR07-061 ZTE CORPORATION CDMA 1x Digital Mobile Phone Accreditation Certificate This Annex consists of 2 pages Date of Report: 2007-10-31 No.SAR07-061 Page 8 of 10 No.SAR07-061 ANNEX B of ShenZhen Electronic Product Quality Testing Center CONFORMANCE TEST REPORT FOR HUMAN EXPOSURE TO ELECTROMAGNETIC FIELDS SAR07-061 ZTE CORPORATION CDMA 1x Digital Mobile Phone Type Name: ZTEC335 Hardware Version: CH2B Software Version: ZTC335MRT01 Sample Photographs This Annex consists of 2 pages Date of Report: 2007-10-31 No.SAR07-061 Page 10 of 10 1. Photograph of the Equipment under Test 1.1. Appearance

RF Exposure Info

No.SAR07-060 Page 3 of 55 Contents 1. GENERAL CONDITIONS 2. ADMINISTRATIVE DATA 2.1. Identification of the Responsible Testing Laboratory 2.2. Identification of the Responsible Testing Location(s) 2.3. Organization Item 2.4. Identification of Applicant 2.5. Identification of Manufacture 3. EQUIPMENT UNDER TEST (EUT) 3.1. Identification of the Equipment under Test 3.2. Identification of all used Test Sample of the Equipment under Test 4. OPERATIONAL CONDITIONS DURING TEST 4.1. Schematic Test Configuration 4.2. SAR Measurement System 5. CHARACTERISTICS OF THE TEST 5.1. Applicable Limit Regulations 5.2. Applicable Measurement Standards 6. LABORATORY ENVIRONMENT 7. 3G MEASUREMENT PROCEDURES 8. TEST RESULTS 8.1. Dielectric Performance 8.2. Summary of Measurement Results 8.3. Conclusion 9. MEASUREMENT UNCERTAINTY 10. MAIN TEST INSTRUMENTS This Test Report consists of the following Annexes: Annex A: Accreditation Certificate Annex B: Test Layout Annex C: Sample Photographs Annex D: Graph Test Results Annex E: System Performance Check Data No.SAR07-060 Page 4 of 55 1.GENERAL CONDITIONS 1.1 This report only refers to the item that has undergone the test. 1.2 This report standalone dose not constitute or imply by its own an approval of the product by the certification Bodies or competent Authorities. 1.3 This document is only valid if complete; no partial reproduction can be made without written approval of Shenzhen Electronic Product Quality Testing Center. 1.4 This report cannot be used partially or in full for publicity and/or promotional purposes without previous written approval of Shenzhen Electronic Product Quality Testing Center and the Accreditation Bodies, if it applies. No.SAR07-060 Page 5 of 55 2. Administrative Date 2.1. Identification of the Responsible Testing Laboratory Company Name: ShenZhen Electronic Product Quality Testing Center Department: Testing Department Address: Electronic Testing Building, ShaHe Road, NanShan District, ShenZhen, P. R. China Telephone: +86-755-26628676 Fax: +86-755-26627238 Responsible Test Lab Managers: Mr. Wu Li’an 2.2. Identification of the Responsible Testing Location(s) Company Name: ShenZhen Electronic Product Quality Testing Center Address: Electronic Testing Building, ShaHe Road, NanShan District, ShenZhen, P. R. China 2.3. Organization Item S.E.T Report No.: SAR07-060 S.E.T Project Leader: Mr. Li Sixiong S.E.T Responsible for accreditation scope: Mr. Wu Li’an Start of Testing: 2007-10-22 End of Testing: 2007-10-31 2.4. Identification of Applicant Company Name: ZTE CORPORATION Address: ZTE Plaza, Keji Road South, Hi-Tech Industrial Park,Nanshan District,Shenzhen, Guangdong, 518057, P.R.China Contact person: Dang.yingchun Telephone: +86-029-88723843 Fax: +86-029-88723529 2.5. Identification of Manufacture Company Name: ZTE CORPORATION Address: ZTE Plaza, Keji Road South, Hi-Tech Industrial Park,Nanshan District,Shenzhen, Guangdong, 518057, P.R.China Contact person: Dang.yingchun Telephone: +86-029-88723843 Fax: +86-029-88723529 Notes: This data is based on the information by the applicant. No.SAR07-060 Page 6 of 55 3. Equipment Under Test (EUT) 3.1. Identification of the Equipment under Test Brand Name: ZTE 中兴 Ty pe Na me : ZTEC336 Marking Name: ZTEC336 Test frequency CDMA 800MHz Development Stage Identical Prototype Accessories Charger Battery type Li3706T42P3h383857 Battery specification 670 mAh 3.7V Antenna type Build inside Operation mode Call established Modulation mode CDMA General description: Max. Power(ERP) <33dBm for CDMA 800MHz Band NOTE: 1. The EUT is a model of CDMA Mobile Station (“MS” for short in this report) operating in Cellular 800MHz band. 2. Please refer to Appendix C for the photographs of the EUT. For a more detailed features description about the EUT, please refer to User’s Manual. 3.2. Identification of all used Test Sample of the Equipment under Test EUT Code ESN Hardware Version Software Version / / CH2B ZTC335MRT01 No.SAR07-060 Page 7 of 55 4 OPERATIONAL CONDITIONS DURING TEST 4.1 Schematic Test Configuration During SAR test, EUT is in Traffic Mode (Channel Allocated) at Normal Voltage Condition. A communication link is set up with a System Simulator (SS) by air link, and a call is established. The TCH is allocated to 9, 384 and 758 respectively in the case of CDMA 800 MHz. The EUT is commanded to operate at maximum transmitting power. The EUT shall use its internal transmitter. The antenna(s), battery and accessories shall be those specified by the manufacturer. The EUT battery must be fully charged and checked periodically during the test to ascertain uniform power output. If a wireless link is used, the antenna connected to the output of the base station simulator shall be placed at least 50 cm away from the handset. The signal transmitted by the simulator to the antenna feeding point shall be lower than the output power level of the handset by at least 35 dB. 4.2 SAR Measurement System The SAR measurement system being used is the IndexSAR SARA2 system, which consists of a Figure1. SAR Lab Test Measurement Set-up Mitsubishi RV-E2 6-axis robot arm and controller, IndexSAR probe and amplifier and SAM phantom No.SAR07-060 Page 8 of 55 Head Shape. The system is controlled remotely from a PC, which contains the software to control the robot and data acquisition equipment. The software also displays the data obtained from test scans. In operation, the system first does an area (2D) scan at a fixed depth within the liquid from the inside wall of the phantom. When the maximum SAR point has been found, the system will then carry out a 3D scan centred at that point to determine volume averaged SAR level. 4.2.1 Robot system specification The robot is used to articulate the probe to programmed positions inside the phantom head to obtain the SAR readings from the DUT. 4.2.2 Probe and amplifier specification IXP-050 Indexsar isotropic immersible SAR probe The probes are constructed using three orthogonal dipole sensors arranged on…

Text truncated - open the document above for the full version.

Test Report

FCC PART 22 TYPE APPROVALS EMI MEASUREMENT AND TEST REPORT For ZTE Corporation ZTE Plaza, Hi-tech Park, Nanshan District, Shenzhen, Guangdong, China 518057 FCC ID: Q78-ZTEC335 Model: ZTE C335 This Report Concerns: Original Report Product Type: 800 MHz CDMA2000 1X Mobile Phone Test Engineer: Jeff Zhang GuanBin Report No.: B0711017 Report Date: 2007-10-30 Reviewed By: David Gong Lab Manager Prepared By: ZTE Corporation Reliability Testing Center ZTE Plaza,Keji Road South,Hi-Tech Industrial Park, NanShan District, Shenzhen,Guangdong,518057,P.R. of China Tel: +86-755-26770345 Fax: +86-755-26770347 ZTE Corporation FCC ID: Q78-ZTEC335 Page 2 of 46 TABLE OF CONTENTS GENERAL INFORMATION.......................................................................................................................................4 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .....................................................................................4 EUT PHOTO.................................................................................................................................................................4 OBJECTIVE...................................................................................................................................................................4 RELATED SUBMITTAL(S)/GRANT(S).............................................................................................................................4 TEST METHODOLOGY..................................................................................................................................................5 TEST FACILITY.............................................................................................................................................................5 SYSTEM TEST CONFIGURATION ..........................................................................................................................6 JUSTIFICATION.............................................................................................................................................................6 EQUIPMENT MODIFICATIONS.......................................................................................................................................6 LOCAL SUPPORT EQUIPMENT LIST AND DETAILS........................................................................................................6 TEST SETUP BLOCK DIAGRAM.....................................................................................................................................6 SUMMARY OF TEST RESULTS ...............................................................................................................................7 §2.1047 - MODULATION CHARACTERISTIC .......................................................................................................8 APPLICABLE STANDARD..............................................................................................................................................8 §2.1053 - SPURIOUS RADIATED EMISSIONS........................................................................................................9 APPLICABLE STANDARD..............................................................................................................................................9 TEST PROCEDURE........................................................................................................................................................9 TEST EQUIPMENT LIST AND DETAILS...........................................................................................................................9 ENVIRONMENTAL CONDITIONS..................................................................................................................................10 TEST RESULT.............................................................................................................................................................10 §2.1046, §22.913(A) – RF OUTPUT POWER ...........................................................................................................13 APPLICABLE STANDARD............................................................................................................................................13 TEST PROCEDURE......................................................................................................................................................13 TEST EQUIPMENT LIST AND DETAILS.........................................................................................................................13 ENVIRONMENTAL CONDITIONS..................................................................................................................................13 TEST RESULTS...........................................................................................................................................................14 §2.1049, §22.917, §22.905 - OCCUPIED BANDWIDTH .........................................................................................21 APPLICABLE STANDARD............................................................................................................................................21 TEST PROCEDURE......................................................................................................................................................21 TEST EQUIPMENT LIST AND DETAILS.........................................................................................................................21 ENVIRONMENTAL CONDITIONS..................................................................................................................................21 TEST RESULTS...........................................................................................................................................................21 §2.1051, §22.917 - SPURIOUS EMISSIONS AT ANTENNA TERMINALS...............................…

Text truncated - open the document above for the full version.

Test Setup Photos

ZTE Corporation FCC ID: Q78-ZTEC335 Page 39 of 46 EXHIBIT B - TEST SETUP PHOTOGRAPHS Radiated Setup (Below 1 GHz) ZTE Corporation FCC ID: Q78-ZTEC335 Page 40 of 46 Radiated Setup (Above1 GHz)

Contact Information

Applicant

Cary Kong(Product Certification Manager)
[email protected]0086-755-26777740Fax: 0086-755-26770347

Test Firm

ZRT EMC Shenzhen LaboratoryBright Xie
[email protected]86-755-26771609Fax: 86-755-26770347

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
122H824.7 MHz - 848.31 MHz294.00 mW1M25F9W2.5000000000 ppm
Confidentiality
Long Term
Grant Notes
Output power listed is Conducted, SAR compliance for body-worn operations is restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device and the user�s body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are: Part 22 - Head: 1.59 W/kg, Body-worn: 0.444 W/kg.

Other Applications from ZTE Corporation

Home Gateway - FCC ID Q78-E1320 - ZTE Corporation
Q78-E1320

Home Gateway

Oct 06, 2022

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Home Gateway - FCC ID Q78-E3330 - ZTE Corporation
Q78-E3330

Home Gateway

Sep 21, 2022

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
RichMedia Box - FCC ID Q78-ZXV10B866V2 - ZTE Corporation
Q78-ZXV10B866V2

RichMedia Box

May 23, 2021

Equipment Class

DTS - Digital Transmission System
Home Gateway - FCC ID Q78-ZXHNH298Q - ZTE Corporation
Q78-ZXHNH298Q

Home Gateway

Apr 22, 2021

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Home Gateway - FCC ID Q78-ZXHNH196Q - ZTE Corporation
Q78-ZXHNH196Q

Home Gateway

Apr 19, 2021

Equipment Class

NII - Unlicensed National Information Infrastructure TX