FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. ZTE Corporation/
  3. Q78-ZTEMF669

Q78-ZTEMF669HSPA+ USB Modem

ZTE Corporation
HSPA+ USB Modem - FCC ID Q78-ZTEMF669 - ZTE Corporation
Click to zoom

Application Details

Equipment Class
PCB - PCS Licensed Transmitter
Date of Grant
Feb 07, 2012
Application Purpose
Original Equipment
Date of Application
Feb 02, 2012
Equipment Note
HSPA+ USB Modem
Frequency Range
1852.40000000 - 1907.60000000
Company
ZTE Corporation
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

MF669 USB Modem Quick Guide ZTE CORPORATION NO. 55, Hi-tech Road South, ShenZhen, P.R.China Postcode: 518057 LEGAL INFORMATION Copyright © 2011 ZTE CORPORATION. All rights reserved. No part of this publication may be excerpted, reproduced, translated or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without the prior written permission of ZTE Corporation. The manual is published by ZTE Corporation. We reserve the right to make modifications on print errors or update specifications without prior notice. Version No. : R1.0 Confidential and Proprietary Information of ZTE CORPORATION 1 C h a p t e r 1 Introduction The ZTE USB modem is a multi-mode USB modem, working in HSPA+/HSPA/WCDMA/EDGE/GPRS/GSM networks. With USB interface connecting to a laptop or a desktop PC, it integrates the functionality of a modem and a mobile phone (SMS), and combines mobile communication with Internet perfectly. It supports data and SMS services through the mobile phone network, enabling you to communicate anytime and anywhere. Specification The following table shows the specification of your device. Interface Type USB 2.0 HIGH SPEED Systems supported Supports most types of laptop and desktop PC. Operating systems supported Windows XP(SP2 or later), Vista(32bit or 64bit), Windows 7 MAC 10.4 or later Functions SMS service, Data service, Applications management, support microSD card, etc. Network Standards HSPA+/HSPA/WCDMA/EDGE/GPRS/GSM Transmission speed (Max) HSUPA: 5.76 Mb/s UL HSPA+: 21.6 Mb/s DL Temperature Storage: -20 °C ~ +70 °C Operation:-10 °C ~ +60 °C Dimension 90 mm×27 mm×12.5 mm(without cap) Weight About 28 g microSD capacity Up to 32 G Notes: microSD is a trademark of SD Card Association. Getting to know your device The following figure shows the appearance of the MF669. It is only for your reference. The actual product may be different. MF669 Quick Guide 2 Confidential and Proprietary Information of ZTE CORPORATION 1. LED Indicator 2. Front Cover 3. USB Connector 4. SIM/USIM card slot 5. External Antenna Jack 6. microSD card slot Hardware Installation 1. Put finger on the bottom finger grip, and then lift the front cover of the modem to release and remove. Notes: Do not open the front cover rudely to avoid the damage of the front cover. 2. Insert the SIM/USIM card and microSD card. Insert the SIM/USIM card with the metal contact area facing downwards into the slot, and then insert the microSD card, shown as the following picture. MF669 Quick Guide Confidential and Proprietary Information of ZTE CORPORATION 3 Notes: The modem only supports microSD card. 3. Close the front cover as shown in the following picture. 4. Connect the Modem to your laptop or desktop PC. f Plug the USB connector into your computer’s USB port and make sure that it is tightly inserted. f The OS will automatically recognize the new hardware and start the installation wizard. Warning and Notice To the owner • Some electronic devices are susceptible to electromagnetic interference sent by modem if inadequately shielded, such as the electronic system of vehicles. Please consult the manufacturer of the device before using the modem if necessary. • Operating of laptop and desktop PCs and the modem may interfere with medical devices like hearing aids and pacemakers. Please always keep them more than 20 centimeters away from such medical devices when they are turned on. Turn the modem off if necessary. Consult a physician or the MF669 Quick Guide 4 Confidential and Proprietary Information of ZTE CORPORATION manufacturer of the medical device before using the modem. • Be aware of the usage limitation when using a modem at places such as oil warehouses or chemical factories, where there are explosive gases or explosive products being processed. Turn off your modem if required. • The use of electronic transmitting devices is forbidden in aircrafts, at petrol stations and in hospitals. Please observe and obey all warning signs and switch off your modem in these conditions. • Do not touch the inner antenna area if not necessary. Otherwise it will affect your modem’s performance. • Store the modem out of the reach of little children. The modem may cause injury if used as a toy. • Do not touch the metallic parts of the modem so as to avoid a burn, when the modem is working. Using your USB Modem • Please use original accessories or accessories that are authorized. Using any unauthorized accessories may affect your modem’s performance, and violate related national regulations about telecom terminals. • Avoid using the modem near or inside metallic structures or establishments that can emit electromagnetic waves. Otherwise it may influence signal reception. • The modem is not waterproof. Please keep it dry and store in a shady and cool place. • Do not use the modem immediately after a sudden temperature change. In such case, it will produce dew inside and outside the modem, so don’t use it until it becomes dry. • Handle the modem carefully. Do not drop, bend or strike it. Otherwise the modem will be damaged. • No dismantling by non-professionals and only qualified technicians can undertake repair work. • Operating temperature range of -10 °C ~ +60 °C and humidity range of 5% ~ 95% are recommended. Radio Frequency (RF) Energy This model device meets the government’s requirements for exposure to radio waves. This device is designed and manufactured not to exceed the emission limits for exposure to radio frequency (RF) energy set by the Federal Communications Commission of the U.S. Government: The exposure standard for wireless devices employs a unit of measurement known as the Specific Absorption Rate, or SAR. The SAR limit set by the FCC is 1.6 W/kg. *Tests for SAR are conducted using standard operating positions accepted by the FCC with the device transmitting at its highest certified power level in all tested frequency bands. Although the SAR is determined at the highest certified power le…

Text truncated - open the document above for the full version.

Cover Letter(s)

内部公开▲ 本文中的所有信息归中兴通讯股份有限公司所有,未经允许,不得外传 第 1 / 1 页 ZTE CORPORATION ZTE Plaza, Keji Road South, Hi-Tech Industrial Park,Nanshan District,Shenzhen, Guangdong, 518057, P.R.China Date: Oct.10,2011 To: Federal Communications Commission, Authorization & Evaluation Division, 7435 Oakland Mills Road, Columbia, MD 21046 And American Telecommunications Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 To Whom It May Concern: Tejet is authorized to act on our behalf, until otherwise notified, for applications to American Telecommunications Certification Body, Inc. (ATCB). We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b) to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you. Regards, Royce Wang ZTE CORPORATION Tel:0755-26770345 Fax:0755-26770347 E-Mail:[email protected]

Cover Letter(s)

内部公开▲ 本文中的所有信息归中兴通讯股份有限公司所有,未经允许,不得外传 第 1 / 1 页 ZTE CORPORATION ZTE Plaza, Keji Road South, Hi-Tech Industrial Park,Nanshan District,Shenzhen, Guangdong, 518057, P.R.China Date: Oct.10,2011 Federal Communications Commission Office of Engineering and Technology Equipment Authorization Division 7345 Oakland Mills Road Columbia, Maryland 21046 Subject: Permanent Confidentiality request for FCC ID: Q78-ZTEMF669 To Whom It May Concern, Pursuant to sections 0.457 and 0.459 of CFR 47, the applicant requests permanent confidential treatment of the following information accompanying this application: - Block Diagram - Schematics - Operational Description - BOM list/Tune-Up-Procedure The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. Yours Sincerely, Royce Wang ZTE CORPORATION Tel:0755-26770345 Fax:0755-26770347 E-Mail:[email protected]

ID Label/Location Info

FCC ID:Q78-ZTEMF669 IMEI :xxxxxxxxxxxxxxx

RF Exposure Info

Report No. 2011SAR220 Ver.4.0 Page 2 of 123 General Information Product Name HSPA+ USB Modem Model Name MF669 Applicant ZTE CORPORATION Manufacturer ZTE CORPORATION Reference Standard ANSI/IEEE C95.1-2005 SAFETY LEVELS WITH RESPECT TO HUMAN EXPOSURE TO RADIO FREQUENCY ELECTROMAGNETIC FIELDS. 3 KHZ TO 300 GHZ ANSI/IEEE C95.3-2002 RECOMMENDED PRACTICE FOR MEASUREMENTS AND COMPUTATIONS OF RADIO FREQUENCY ELECTROMAGNETIC FIELDS WITH RESPECT TO HUMAN EXPOSURE TOSUCH FIELDS. 100 KHZ-300 GHZ OET Bulletin 65-(Edition 97-01) Supplement C(edition01-01) Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields---Additional Supplement C (Edition 01-01)Information for Evaluating Compliance of Mobile and Portable Devices with FCC Limits for Human Exposure to Radiofrequency Emissions Test Results Pass Report No. 2011SAR220 Ver.4.0 Page 3 of 123 Change History Version Change Contents Author Date V1.0 First edition Yin xiaoming 2012-1-4 V2.0 a) Page 26-28 ,Update the output power. b) Page35,Add evaluating for SAR measurements with the maximum target value in Turn-up Procedure . Yin xiaoming 2012-1-13 V3.0 Page35, Change evaluating for SAR measurements with the maximum target value in Turn-up Procedure . Yin xiaoming 2012-2-1 V4.0 Page20, add judgment for second hotspot within 2dB. Page35, remove the table of evaluating for SAR with the maximum target value in Turn-up Procedure Yin xiaoming 2012-2-3 Report No. 2011SAR220 Ver.4.0 Page 4 of 123 CONTENTS: CHANGE HISTORY ............................................................................................................ 3 1. TEST LABORATORY ...................................................................................................... 6 1.1 TESTING LOCATION: ....................................................................................................................... 6 1.2 LABORATORY ENVIRONMENT ......................................................................................................... 6 1.3 TESTING DATE ................................................................................................................................ 6 2. CLIENT INFORMATION .................................................................................................. 7 2.1 APPLICANT INFORMATION .............................................................................................................. 7 2.2 MANUFACTURER INFORMATION ..................................................................................................... 7 3.EQUIPMENT UNDER TEST (EUT) AND ACCESSORY EQUIPMENT (AE) ............... 8 3.1 INFORMATION OF EUT ................................................................................................................... 8 3.2 INFORMATION OF AE ..................................................................................................................... 9 4. CHARACTERISTICS OF THE TEST ............................................................................ 11 4.1. APPLICABLE LIMIT REGULATIONS ............................................................................................... 11 4.2. APPLICABLE MEASUREMENT STANDARDS ................................................................................. 11 5.OPERATIONAL CONDITIONS DURING TEST .......................................................... 12 5.1 GENERAL DESCRIPTION OF TEST PROCEDURES .......................................................................... 12 5.2 GSM TEST CONFIGURATION ....................................................................................................... 12 5.3 WCDMA TEST CONFIGURATION ................................................................................................. 12 6. SAR MEASUREMENTS SYSTEM CONFIGURATION ................................................ 15 6.1 SAR MEASUREMENT SET-UP .................................................................................................... 15 6.2. DASY5 E-FIELD PROBE SYSTEM .............................................................................................. 16 6.2.1. Ex3DV3 Probe Specification ........................................................................................... 16 6.2.2. E-field Probe Calibration ................................................................................................. 17 6.3. OTHER TEST EQUIPMENT ........................................................................................................... 18 6.3.1. Device Holder for Transmitters ....................................................................................... 18 6.3.2. Phantom ............................................................................................................................. 19 6.4. SCANNING PROCEDURE .............................................................................................................. 19 6.5. DATA STORAGE AND EVALUATION .............................................................................................. 21 6.5.1. Data Storage ..................................................................................................................... 21 6.5.2. Data Evaluation by SEMCAD ......................................................................................... 21 6.6. SYSTEM CHECK ........................................................................................................................... 23 6.7. EQUIVALENT TISSUES ................................................................................................................. 24 7. CONDUCTED OUTPUT POWER MEASUREMENT .................................................... 26 7.1. SUMMARY ................................................................................................................................... 26 Report No. 2011SAR220 Ver.4.0 Page 5 of 123 7.2. CONDUCTED POWER RESULTS ...................................................…

Text truncated - open the document above for the full version.

Test Report

No.2012TAR006 Page1 of 52 ©Copyright. All rights reserved by TMC Beijing. TEST REPORT No. 2012TAR006 for ZTE CORPORATION HSPA+ USB Modem Model Name: MF669 FCC ID: Q78-ZTEMF669 with Hardware Version: dp3A Software Version: EN_ZTE_HDMF669V1.0.1B03 Issued Date: Dec 31, 2011 Note: The test results in this test report relate only to the devices specified in this report. This report shall not be reproduced except in full without the written approval of TMC Beijing. Test Laboratory: DAR accreditation (DIN EN ISO/IEC 17025): No. DAT-P-114/01-01 FCC 2.948 Listed: No.733176 IC O.A.T.S listed: No.6629A-1 TMC Beijing, Telecommunication Metrology Center of Ministry of Industry and Information Technology Shouxiang Science Building, No 51, Xueyuan Road, Haidian District, Beijing, P.R.China 100191 Tel:+86(0)10-62304633-2678, Fax:+86(0)10-62304793 Email:[email protected]. www.emcite.com No.2012TAR006 Page2 of 52 ©Copyright. All rights reserved by TMC Beijing. CONTENTS 1. TEST LABORATORY ......................................................................................................................... 3 1.1. TESTING LOCATION .................................................................................................................... 3 1.2. TESTING ENVIRONMENT ........................................................................................................... 3 1.3. PROJECT DATA .............................................................................................................................. 3 1.4. SIGNATURE ..................................................................................................................................... 3 2. CLIENT INFORMATION ................................................................................................................... 4 2.1. APPLICANT INFORMATION ....................................................................................................... 4 2.2. MANUFACTURER INFORMATION ............................................................................................ 4 3. EQUIPMENT UNDER TEST (EUT) AND ANCILLARY EQUIPMENT (AE) ............................. 5 3.1. ABOUT EUT ..................................................................................................................................... 5 3.2. INTERNAL IDENTIFICATION OF EUT USED DURING THE TEST .................................... 5 3.3. GENERAL DESCRIPTION ............................................................................................................ 5 4. REFERENCE DOCUMENTS ............................................................................................................. 6 4.1. REFERENCE DOCUMENTS FOR TESTING ............................................................................. 6 5. LABORATORY ENVIRONMENT ..................................................................................................... 7 6. SUMMARY OF TEST RESULTS ....................................................................................................... 8 7. TEST EQUIPMENTS UTILIZED ...................................................................................................... 9 ANNEX A: MEASUREMENT RESULTS ................................................................................................ 10 A.1 OUTPUT POWER (§22.913(A)/§24.232(B)) .......................................................................... 10 A.2 EMISSION LIMT (§2.1051/§22.917§24.238) ............................................................................. 14 A.3 FREQUENCY STABILITY (§2.1055/§24.235) .......................................................................... 20 A.4 OCCUPIED BANDWIDTH (§2.1049(H)(I)) ............................................................................... 22 A.5 EMISSION BANDWIDTH (§22.917(B)/§24.238(B)) ............................................................... 26 A.6 BAND EDGE COMPLIANCE (§22.917(B)/§24.238(B)) .......................................................... 30 A.7 CONDUCTED SPURIOUS EMISSION (§2.1057/§22.917/§24.238) ......................................... 32 No.2012TAR006 Page3 of 52 ©Copyright. All rights reserved by TMC Beijing. 1. Test Laboratory 1.1. Testing Location Company Name: TMC Beijing, Telecommunication Metrology Center of MIIT Address: Shouxiang Science Building, No 51, Xueyuan Road, Haidian District, Beijing, P.R.China Postal Code: 100191 Telephone: 00861062304633 Fax: 00861062304793 1.2. Testing Environment Normal Temperature: 15-35°C Relative Humidity: 20-75% 1.3. Project data Testing Start Date: Dec 22, 2011 Testing End Date: Dec 31, 2011 1.4. Signature Zi Xiaogang (Prepared this test report) Sun Xiangqian (Reviewed this test report) Lu Bingsong Deputy Director of the laboratory (Approved this test report) No.2012TAR006 Page4 of 52 ©Copyright. All rights reserved by TMC Beijing. 2. Client Information 2.1. Applicant Information Company Name: ZTE CORPORATION Address /Post: ZTE Plaza, Keji Road South, Hi-Tech Industrial Park, Nanshan District, Shenzhen, Guangdong, 518057, P.R.China City: Shenzhen Postal Code: 518057 Country: China Telephone: 0086 21 68895196 Fax: 0086 21 61460600 2.2. Manufacturer Information Company Name: ZTE CORPORATION Address /Post: ZTE Plaza, Keji Road South, Hi-Tech Industrial Park, Nanshan District, Shenzhen, Guangdong, 518057, P.R.China City: Shenzhen Postal Code: 518057 Country: China Telephone: 0086 21 68895196 Fax: 0086 21 61460600 No.2012TAR006 Page5 of 52 ©Copyright. All rights reserved by TMC Beijing. 3. Equipment Under Test (EUT) and Ancillary Equipment (AE) 3.1. About EUT Description HSPA+ USB Modem Model Name MF669 FCC ID Q78-ZTEMF669 Frequency GSM 850MHz; PCS 1900MHz;WCDMA Band II; WCDMA Band V; Antenna Internal Power supply Battery or Charger (AC Adaptor) Output power 22.82 dBm maximum EIRP measured for UMTS1900 Extreme vol. Limits 4.8VDC to 5.2VDC (nominal: 5.0VDC) Extreme temp. Tolerance -30°C to +50°C Note: Components list, …

Text truncated - open the document above for the full version.

Test Report

No.2012TAR005 Page1 of 74 TEST REPORT No. 2012TAR005 for ZTE CORPORATION HSPA+ USB Modem Model Name: MF669 FCC ID: Q78-ZTEMF669 with Hardware Version: dp3A Software Version: EN_ZTE_HDMF669V1.0.1B03 Issued Date: Feb 6, 2012 Note: The test results in this test report relate only to the devices specified in this report. This report shall not be reproduced except in full without the written approval of TMC Beijing. Test Laboratory: DAR accreditation (DIN EN ISO/IEC 17025): No. DGA-PL-114/01-02 FCC 2.948 Listed: No.733176 IC O.A.T.S listed: No.6629A-1 TMC Beijing, Telecommunication Metrology Center of Ministry of Industry and Information Technology 3/F Shou Xiang Technology Building, No.51 Xueyuan Road, Hai Dian District, Beijing, P. R. China,100191. Tel:+86(0)10-62304633-2604, Fax:+86(0)10-62304793, Email:[email protected], web: www.emcite.com No.2012TAR005 Page2 of 74 CONTENTS 1. TEST LABORATORY ......................................................................................................................... 3 1.1. TESTING LOCATION .................................................................................................................... 3 1.2. TESTING ENVIRONMENT ........................................................................................................... 3 1.3. PROJECT DATA .............................................................................................................................. 3 1.4. SIGNATURE ..................................................................................................................................... 3 2. CLIENT INFORMATION ................................................................................................................... 4 2.1. APPLICANT INFORMATION ....................................................................................................... 4 2.2. MANUFACTURER INFORMATION ............................................................................................ 4 3. EQUIPMENT UNDER TEST (EUT) AND ANCILLARY EQUIPMENT (AE) ............................. 5 3.1. ABOUT EUT ..................................................................................................................................... 5 3.2. INTERNAL IDENTIFICATION OF EUT USED DURING THE TEST .................................... 5 3.3. GENERAL DESCRIPTION ............................................................................................................ 5 4. REFERENCE DOCUMENTS ............................................................................................................. 6 4.1. REFERENCE DOCUMENTS FOR TESTING ............................................................................. 6 5. LABORATORY ENVIRONMENT ..................................................................................................... 7 6. SUMMARY OF TEST RESULTS ....................................................................................................... 8 7. TEST EQUIPMENTS UTILIZED ...................................................................................................... 9 ANNEX A: MEASUREMENT RESULTS ................................................................................................ 10 A.1 OUTPUT POWER (§22.913(A)/§24.232(C)) ............................................................................... 10 A.2 EMISSION LIMT (§2.1051/§22.917§24.238) ............................................................................. 16 A.3 FREQUENCY STABILITY (§2.1055/§24.235) ......................................................................... 22 A.4 OCCUPIED BANDWIDTH (§2.1049(H)(I)) ................................................................................. 24 A.5 EMISSION BANDWIDTH (§22.917(B)/§24.238(B)) .................................................................. 36 A.6 BAND EDGE COMPLIANCE (§22.917(B)/§24.238(B)) ............................................................. 48 A.7 CONDUCTED SPURIOUS EMISSION (§2.1057/§22.917/§24.238) ........................................... 54 No.2012TAR005 Page3 of 74 1. Test Laboratory 1.1. Testing Location Company Name: TMC Beijing, Telecommunication Metrology Center of MIIT Address: 3/F Shou Xiang Technology Building, No.51 Xueyuan Road, Hai Dian District, Beijing, P. R. China Postal Code: 100191 Telephone: 00861062304633 Fax: 00861062304793 1.2. Testing Environment Normal Temperature: 15-35°C Relative Humidity: 20-75% 1.3. Project data Testing Start Date: Dec 22, 2011 Testing End Date: Feb 6, 2012 1.4. Signature Zi Xiaogang (Prepared this test report) Sun Xiangqian (Reviewed this test report) Lu Bingsong Deputy Director of the laboratory (Approved this test report) No.2012TAR005 Page4 of 74 2. Client Information 2.1. Applicant Information Company Name: ZTE CORPORATION Address /Post: ZTE Plaza, Keji Road South, Hi-Tech Industrial Park, Nanshan District, Shenzhen, Guangdong, 518057, P.R.China City: Shenzhen Postal Code: 518057 Country: China Telephone: 0086 21 68895196 Fax: 0086 21 61460600 2.2. Manufacturer Information Company Name: ZTE CORPORATION Address /Post: ZTE Plaza, Keji Road South, Hi-Tech Industrial Park, Nanshan District, Shenzhen, Guangdong, 518057, P.R.China City: Shenzhen Postal Code: 518057 Country: China Telephone: 0086 21 68895196 Fax: 0086 21 61460600 No.2012TAR005 Page5 of 74 3. Equipment Under Test (EUT) and Ancillary Equipment (AE) 3.1. About EUT Description HSPA+ USB Modem Model Name MF669 FCC ID Q78-ZTEMF669 Frequency GSM 850MHz; PCS 1900MHz;WCDMA Band II; WCDMA Band V; Antenna Internal Power supply Battery or Charger (AC Adaptor) Output power 27.32 dBm maximum ERP measured for GSM850 Extreme vol. Limits 4.8VDC to 5.2VDC (nominal: 5.0VDC) Extreme temp. Tolerance -30°C to +50°C Note: Components list, please refer to documents of the manufacturer; it is also included in the original test record of Telecommunication Metrology Center of MIIT of People’s Republic of China. 3.2. Internal Identification of…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Cary Kong(Product Certification Manager)
[email protected]0086-755-26777740Fax: 0086-755-26770347

Technical Contact

Shanghai Tejet Communications TechnologyCo., Ltd.Xu Yafan
[email protected]+86-21-61650880

Room 6205-6208, Building 6, No.399 Cailun Rd. · Shanghai, · China

Test Firm

Shanghai Tejet Communications Technology Co., LtdYu Jinlong
[email protected]86-21-61650880Fax: 86-21-61650881

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
624E1.85 GHz - 1.91 GHz191.00 mW4M13F9W0.1 ppm
Confidentiality
Long Term
Grant Notes
Power Output is ERP for Part 22 and EIRP for Part 24. The SAR data in this filing is applicable to demonstrate compliance for the USB Dongle only as shown in this filing. End-users must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. The highest reported SAR value is: Body-worn 1.16 W/kg. This device contains GSM/WCDMA functions that are not operational in U.S. Territories. This filing is only applicable for 850 MHz Cell and 1900 MHz PCS operations.

Other Applications from ZTE Corporation

Home Gateway - FCC ID Q78-E1320 - ZTE Corporation
Q78-E1320

Home Gateway

Oct 06, 2022

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Home Gateway - FCC ID Q78-E3330 - ZTE Corporation
Q78-E3330

Home Gateway

Sep 21, 2022

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
RichMedia Box - FCC ID Q78-ZXV10B866V2 - ZTE Corporation
Q78-ZXV10B866V2

RichMedia Box

May 23, 2021

Equipment Class

DTS - Digital Transmission System
Home Gateway - FCC ID Q78-ZXHNH298Q - ZTE Corporation
Q78-ZXHNH298Q

Home Gateway

Apr 22, 2021

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Home Gateway - FCC ID Q78-ZXHNH196Q - ZTE Corporation
Q78-ZXHNH196Q

Home Gateway

Apr 19, 2021

Equipment Class

NII - Unlicensed National Information Infrastructure TX