FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. ZTE Corporation/
  3. Q78-ZTEZTEWP658

Q78-ZTEZTEWP658GSM wireless phone

ZTE Corporation
GSM wireless phone - FCC ID Q78-ZTEZTEWP658 - ZTE Corporation
Click to zoom

Application Details

Equipment Class
PCB - PCS Licensed Transmitter
Date of Grant
Aug 30, 2012
Application Purpose
Original Equipment
Date of Application
Aug 29, 2012
Equipment Note
GSM wireless phone
Frequency Range
1850.20000000 - 1909.80000000
Company
ZTE Corporation
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

GSM Wireless Phone User Guide ZTE CORPORATION NO. 55, Hi-tech Road South, ShenZhen, P.R.China Postcode: 518057 Tel: (86) 755 26779999 URL: http://www.zte.com.cn E-mail: [email protected] Manual No. : 079584500000 LEGAL INFORMATION Copyright © 2010 ZTE CORPORATION. All rights reserved. No part of this publication may be excerpted, reproduced, translated or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without the prior written permission of ZTE Corporation. The manual is published by ZTE Corporation. We reserve the right to make modifications on print errors or update specifications without prior notice. Confidential and Proprietary Information of ZTE CORPORATION 1 C h a p t e r 1 Know Your Phone 6 10 LCD Screen 5 4 3 2 8 7 1 9 Confidential and Proprietary Information of ZTE CORPORATION 2 C h a p t e r 2 Key Instruction Key Description 1. MENU/SELECT • Enter main menu. • Select or confirm options in menus. 2. Number • Use these keys to enter numbers and characters. 3. # , * • Perform different functions under different conditions. 4.Scrolling • Press these keys to scroll cursor to the left, right, up or down when inputting characters or selecting items. • Default functions in standby mode are set in Settings menu. 5. EXT PWR • Lights up when the phone is connected to external power outlet. 6. NAMES/CLR/BACK • In standby mode, press this key to enter right-bottom submenu on the screen. • Press this key to erase character(s) while editing text. • Press this key to return to the previous page during menu navigation. 7.MESSAGE • This is the shortcut key to enter message menu in standby mode. 8. EXIT • End an active call or reject calls. • Power on/power off the phone. 9. CALL/REDIAL • Make a call or answer an incoming call. • In standby mode, press this key to enter recent calls list. 10.HANDS-FREE • If you are using the handset to call and want to transfer the call to the speakerphone, press this key and hang up the handset to put conversation on the speakerphone. • Press this key to end a hands-free call. Notes: In this manual, “press” a key means to press the key once, “hold” a key means to press the key for 2 or 3 seconds. Confidential and Proprietary Information of ZTE CORPORATION 3 C h a p t e r 3 Interface Icons Icon Description Icon Description Signal strength New message (blinks when memory is full) Silent Divert always Power indicator Alarm clock Keypad lock Confidential and Proprietary Information of ZTE CORPORATION 4 C h a p t e r 4 Installation 1. Handset Connect phone and handset via the phone cord. 2. External power adapter Plug the external power adapter to the external AC socket. 3. SIM card Always switch the phone off before removing or inserting SIM card. Open the bottom cover of the battery. Remove the battery, slide the SIM card into the SIM card slot. Make sure that the contact area of the card is facing down, and the beveled corner matches with the SIM card slot. Put in the battery and install the bottom cover. Confidential and Proprietary Information of ZTE CORPORATION 5 C h a p t e r 5 How to Power on/off ‹ To power on the phone, connect phone and external power outlet with the power adapter and then hold Exit key for about three seconds. ‹ To power off the phone, hold the Exit key till the phone is powered off. Notes: It is strongly recommended to connect the phone to external power outlet, and use internal battery to power your phone only when external power fails or is not available. The phone will charge the internal battery automatically when it is connected to external power outlet. Confidential and Proprietary Information of ZTE CORPORATION 6 C h a p t e r 6 How to Make a Call There are two methods for making a call. „ The first method: 1. Pick up the handset or press the HANDS-FREE key. 2. Enter the phone number, wait for several seconds to send the call automatically or press CALL/REDIAL key to make the call. Select recipient’s number from Phonebook, or press CALL/REDIAL key to select a number from the recent calls list, then press CALL/REDIAL key to make the call. „ The second method: Enter the number or select recipient’s number from Phonebook, or press CALL/REDIAL key to select a number from the recent calls list, then press CALL/REDIAL key to make the call. Notes: Add the international prefix, country code and area code (without the leading 0) before the number when making an international call. Confidential and Proprietary Information of ZTE CORPORATION 7 C h a p t e r 7 Voice Mail Before using voice mail, please contact service provider to confirm that the voicemail has been activated. The system automatically sends a message to your phone to inform you that there is a new voice mail. Read the message and then dial voice mailbox number to listen to your voice mail. To read or send your voice mail quickly, you set the voice mailbox number first. Pick up the handset or press HANDS-FREE key, and then hold “1” key to dial voice mailbox number. In standby mode, you can also hold “1” key directly to dial voice mailbox number. Confidential and Proprietary Information of ZTE CORPORATION 8 C h a p t e r 8 Message Select Short Message in Menu, and then select Accept. • Select New message to write message text, select Option to send or save the message. • Select Inbox to view messages received. • Select Outbox to view the Only Save or Send and Save messages. • Select Draftbox to view draft messages. • Select Voice mail to listen to your voice mail messages, or set the voice mailbox number. • Select Message settings to make some necessary short message settings. Confidential and Proprietary Information of ZTE CORPORATION 9 C h a p t e r 9 Phone Code Phone code could prevent your phone from unauthorized use. The default phone code is 1234. Change it to your own as soon as possible. If you change the default phone code to a new one, remember it or place it at secure place. Confidential and Proprietary Informatio…

Text truncated - open the document above for the full version.

Attestation Statements

Percsson communication Equipment Co.,Ltd The test report belongs to Percsson and clients confidential file,please safekeeping,Without my company and relevant customers approval,anybody not to foreign leakage。 The 1th page 5 pages in total PRS ANT R Percsson Communication Equipment Co.,Ltd Admit Antenna Contract Customer name:ZTE Customer project:ZTE WP658 Customer part number:0301000-000191 Frequency band:GSM850/PCS Model:HM-G2-TLT-B Manufacturer:Percsson Communication Equipment Co.,Ltd Contract Date:2012-8-10 The manufacturer column : maker verifier approver The customer column: confirmor verifier approver Percsson communication Equipment Co.,Ltd The test report belongs to Percsson and clients confidential file,please safekeeping,Without my company and relevant customers approval,anybody not to foreign leakage。 The 1th page 5 pages in total PRS ANT R 1.Product specifications Antenna Model HM-G2-TLT-B Main Electrical Specifications Frequency Rang (MHz) 824/896/1850/1990MHz VSWR 824≤3.0:896≤2.5;1850≤3.5:1990≤4.5 Impedance (Ω) 50Ω Polarization Vertical Polarization Main Structure Specifications Length 220MM Connector Type TNC Color black 2.Telephone Picture 3.Antenna appearance picture Percsson communication Equipment Co.,Ltd The test report belongs to Percsson and clients confidential file,please safekeeping,Without my company and relevant customers approval,anybody not to foreign leakage。 The 1th page 5 pages in total PRS ANT R 4.Antenna assembe picture 5.Electrical performance report 5.1VSWR Percsson communication Equipment Co.,Ltd The test report belongs to Percsson and clients confidential file,please safekeeping,Without my company and relevant customers approval,anybody not to foreign leakage。 The 1th page 5 pages in total PRS ANT R 5.2.TRP and TIS test results 5.2.1.GSM850 TRP Test GSM850 TRP Result 128 190 251 Frequency (MHz) 824.2 836.6 848.8 TRP(dBm) 30.39 30.41 30.36 NHPRP(dBm) 25.9 27.19 27.16 MAX(dBm) 31.53 33.35 32.87 Min(dBm) 12.98 14.33 16.47 5.2.2.GSM850 TIS Test GSM850 TIS Result 128 190 251 Frequency (MHz) 869.2 881.6 893.8 TIS(dBm) -108.18 -107.82 -107.87 NHPIS(dBm) -105.15 -105.65 -104.15 RSSIAve 38.68 40.02 38.57 MaxPosRSSI 39.74 41.72 39.79 MaxPosSens -109.24 -110.52 -108.79 MAX(dBm) -110.63 -111.96 -110.84 Min(dBm) -92.53 -91.83 -92.76 5.2.3.PCS TRP Result Test PCS TRP Result 512 661 810 Frequency (MHz) 1850.2 1880 1909.8 TRP(dBm) 28.89 28.66 28.55 NHPRP(dBm) 25.85 25.02 23.93 MAX(dBm) 35.79 35.49 34.8 Min(dBm) 16.63 -39.39 15.26 5.2.4.PCS TIS Result Test PCS TIS Result 512 661 810 Frequency (MHz) 1930.2 1960 1989.8 TIS(dBm) -107.5 -107.34 -107.56 NHPIS(dBm) -101.88 -102.25 -102.66 RSSIAve 39.1 38.54 39.16 MaxPosRSSI 45.83 44.48 45.4 MaxPosSens -112.73 -112.28 -112.8 MAX(dBm) -112.79 -112.99 -113.38 Min(dBm) -93.06 -91.36 -91.82 Percsson communication Equipment Co.,Ltd The test report belongs to Percsson and clients confidential file,please safekeeping,Without my company and relevant customers approval,anybody not to foreign leakage。 The 1th page 5 pages in total PRS ANT R unit scale size A4 mm Designer: Verifier: PERCSSON PRS ANT R Approver: ±1.0 ±0.50~5 5~10 10~50 50~ ±2.0 ±5.0 No mark tolerance ±0.5° ±0.05 Name of commodity: Rubber set of antenna Model:HM-G2-TLT-B Customer:DESAY modifier note sign Note: Antenna color black G2 bj Kirsite Kirsite B A Front Reverse 6.Engineering drawings

Cover Letter(s)

内部公开▲ 本文所有信息为中兴通讯股份有限公司内部信息,未经允许,不得外传 第1页,共1页 ZTE CORPORATION ZTE Plaza, Keji Road South, Hi-Tech Industrial Park, Nanshan District, Shenzhen, Guangdong, 518057, P.R.China Date: August 15, 2012 To: Federal Communications Commission, Authorization & Evaluation Division, 7435 Oakland Mills Road, Columbia, MD 21046 And American Telecommunications Certification Body, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 To Whom It May Concern: Shanghai Tejet Communications Technology Co.,Ltd. is authorized to act on our behalf, until otherwise notified, for applications to American Telecommunications Certification Body, Inc. (ATCB). We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b) to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you. Sincerely yours, Yanli Chen ZTE CORPORATION Tel: 0755-26770345 Fax: 0755-26770347 E-Mail: [email protected]

Cover Letter(s)

内部公开▲ 本文所有信息为中兴通讯股份有限公司内部信息,未经允许,不得外传 第1页,共1页 ZTE CORPORATION ZTE Plaza, Keji Road South, Hi-Tech Industrial Park, Nanshan District, Shenzhen, Guangdong, 518057, P.R.China Date: August 15, 2012 Federal Communications Commission Office of Engineering and Technology Equipment Authorization Division 7345 Oakland Mills Road Columbia, Maryland 21046 Subject: Permanent Confidentiality request for FCC ID: Q78-ZTEZTEWP658 To Whom It May Concern, Pursuant to sections 0.457 and 0.459 of CFR 47, the applicant requests permanent confidential treatment of the following information accompanying this application: - Block Diagram - Schematics - Operational Description - BOM list/Tune-Up-Procedure The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant and provide unjustified benefits to its competitors. Sincerely yours, Yanli Chen ZTE CORPORATION Tel: 0755-26770345 Fax: 0755-26770347 E-Mail: [email protected]

RF Exposure Info

Report No. 2012SAR294 Page 2 of 13 V2.0 Applicable Standard FCC RULES 47 CFR2.1091: Radiofrequency radiation exposure evaluation: mobile device OET65C-97-01: Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields Test Results Pass Report No. 2012SAR294 Page 3 of 13 V2.0 Change History Version Change Contents Author Date V1.0 First edition Yin xiaoming 2012-08-08 V2.0 Page 7,change the Tx frequency. Yin xiaoming 2012-08-23 Report No. 2012SAR294 Page 4 of 13 V2.0 CONTENTS: CHANGE HISTORY ............................................................................................................ 3 1. TEST LABORATORY ...................................................................................................... 5 1.1 TESTING LOCATION: ....................................................................................................................... 5 1.2 LABORATORY ENVIRONMENT ......................................................................................................... 5 1.3 TESTING DATE ................................................................................................................................ 5 2. CLIENT INFORMATION .................................................................................................. 6 2.1 APPLICANT INFORMATION .............................................................................................................. 6 2.2 MANUFACTURER INFORMATION ..................................................................................................... 6 3.EQUIPMENT UNDER TEST (EUT) AND ACCESSORY EQUIPMENT (AE) ............... 7 3.1 INFORMATION OF EUT ................................................................................................................... 7 3.2 INFORMATION OF AE ..................................................................................................................... 7 4. REFERENCE DOCUMENTS ....................................................................................... 8 4.1 REFERENCE DOCUMENTS FOR TESTING ............................................................... 8 4.2 RF EXPOSURE LIMIT ................................................................................................... 8 5. FRIIS FORMULA ......................................................................................................... 9 6. CLASSIFICATION ........................................................................................................ 9 7. TEST RESULTS ......................................................................................................... 10 ANNEX A: EUT PHOTOGRAPH ...................................................................................... 11 ANNEX B: TEST INSTRUMENTS .................................................................................... 13 ANNEX C: MEASUREMENT UNCERTAINTY ................................................................. 13 Report No. 2012SAR294 Page 5 of 13 V2.0 1. Test Laboratory 1.1 Testing Location: Company: Shanghai Tejet Communications Technology Co., Ltd Testing Center. Address: Room 6205-6208, Building 6, No.399 Cailun Rd. Zhangjiang Hi-Tech Park, Shanghai, China Post Code : 210203 Tel: +86-21-61650880 Fax: +86-21-61650881 Website: www.tejet.cn 1.2 Laboratory Environment Temperature 20°C~ 25 °C Relative humidity 20%~70% 1.3 Testing date Test Date: 2012-08-07 Report No. 2012SAR294 Page 6 of 13 V2.0 2. Client Information 2.1 Applicant information Company Name: ZTE Corporation Address: ZTE Plaza ,Keji Road South ,Hi-Tech Industrial Park ,Nanshan District, Shenzhen, Guangdong,518057,P.R.China Post Code : 518057 Country: China Tel: 021-68897541 Fax: 021-50801070 2.2 Manufacturer Information Company Name: ZTE Corporation Address: ZTE Plaza ,Keji Road South ,Hi-Tech Industrial Park ,Nanshan District, Shenzhen, Guangdong,518057,P.R.China Post Code : 518057 Country: China Tel: 021-68897541 Fax: 021-50801070 Report No. 2012SAR294 Page 7 of 13 V2.0 3.Equipment Under Test (EUT) and Accessory Equipment (AE) 3.1 Information of EUT Device type Portable device Product name GSM wireless phone Device operation configuration: IMEI or S/N 869444004476669 Operating mode(s): GSM850 GSM1900 Test modulation (GSM)GMSK Rated output power GSM 850:33dBm GSM1900: 30dBm Operating frequency range(s): Band Tx(MHz) GSM850 824.2~848.8 GSM1900 1850.2~1909.8 Power class GSM850: 4,test with power level 5 GSM1900: 1,test with power level 0 3.2 Information Of AE AE ID* Description AE1 Power supply AE2 Battery AE1 Model STC-A22O50C35-C Manufacture ZTE CORPORATION AE2 Model Ni3612T30P3S534416 Manufacture Capacitance ZTE CORPORATION 800mAh *AE ID: is used to identify the test sample in the lab internally. Report No. 2012SAR294 Page 8 of 13 V2.0 4. Reference Documents 4.1 Reference Documents for testing The following documents listed in this section are referred for testing. Reference Title Version OET65C Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields 1997-01 4.2 RF Exposure Limit According to OET65C: The criteria listed in the following table shall be used to evaluate the environmental impact of human exposure to radio-frequency (RF) radiation 。 Report No. 2012SAR294 Page 9 of 13 V2.0 5. Friis Formula Friis transmission formula : Pd = (Pout*G) *DutyFactor / (4*Pi*r 2 ) where Pd = power density in mW/cm 2 Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = distance between observation point and center of the radiator in cm Pd is the limit of MPE. If we know the maximum Gain of the antenna and the total power input to the antenna, through the calculation, we will know the MPE value at distance 20cm. Of GSM Duty Factor=1:8.3. 6. Classification The antennas of this product, under normal use condition, is at least 20cm away from the body of the user. So, this device is classified as Mobile Device. Report No. 2012SAR…

Text truncated - open the document above for the full version.

Test Report

No2012TAR410 Page1 of 58 TEST REPORT No. 2012TAR410 for ZTE CORPORATION GSM wireless phone Model Name: ZTE WP658 FCC ID: Q78-ZTEZTEWP658 with Hardware Version: fd9d Software Version: DS STD CH WP657+V1.0.0B02 Issued Date: Aug 17, 2012 Note: The test results in this test report relate only to the devices specified in this report. This report shall not be reproduced except in full without the written approval of TMC Beijing. Test Laboratory: DAR accreditation (DIN EN ISO/IEC 17025): No. DGA-PL-114/01-02 FCC 2.948 Listed: No.733176 IC O.A.T.S listed: No.6629B TMC Beijing, Telecommunication Metrology Center of Ministry of Industry and Information Technology 3/F Shou Xiang Technology Building, No.51 Xueyuan Road, Hai Dian District, Beijing, P. R. China,100191. Tel:+86(0)10-62304633-2604, Fax:+86(0)10-62304793, Email:[email protected], web: www.emcite.com No2012TAR410 Page2 of 58 CONTENTS 1. TEST LABORATORY ......................................................................................................................... 3 1.1. TESTING LOCATION .................................................................................................................... 3 1.2. TESTING ENVIRONMENT ........................................................................................................... 3 1.3. PROJECT DATA .............................................................................................................................. 3 1.4. SIGNATURE ..................................................................................................................................... 3 2. CLIENT INFORMATION ................................................................................................................... 4 2.1. APPLICANT INFORMATION ....................................................................................................... 4 2.2. MANUFACTURER INFORMATION ............................................................................................ 4 3. EQUIPMENT UNDER TEST (EUT) AND ANCILLARY EQUIPMENT (AE) ............................. 5 3.1. ABOUT EUT ..................................................................................................................................... 5 3.2. INTERNAL IDENTIFICATION OF EUT USED DURING THE TEST .................................... 5 3.3. INTERNAL IDENTIFICATION OF AE USED DURING THE TEST ....................................... 5 3.4. GENERAL DESCRIPTION ............................................................................................................ 6 4. REFERENCE DOCUMENTS ............................................................................................................. 7 4.1. REFERENCE DOCUMENTS FOR TESTING ............................................................................. 7 5. LABORATORY ENVIRONMENT ..................................................................................................... 8 6. SUMMARY OF TEST RESULTS ....................................................................................................... 9 7. TEST EQUIPMENTS UTILIZED .................................................................................................... 10 ANNEX A: MEASUREMENT RESULTS ................................................................................................. 11 A.1 OUTPUT POWER ............................................................................................................................11 A.2 EMISSION LIMT ............................................................................................................................ 17 A.3 CONDUCTED EMISSION ............................................................................................................. 23 A.4 FREQUENCY STABILITY ............................................................................................................ 26 A.5 OCCUPIED BANDWIDTH .............................................................................................................. 28 A.6 EMISSION BANDWIDTH................................................................................................................ 32 A.7 BAND EDGE COMPLIANCE .......................................................................................................... 36 A.8 CONDUCTED SPURIOUS EMISSION ........................................................................................... 38 No2012TAR410 Page3 of 58 1. Test Laboratory 1.1. Testing Location Company Name: TMC Beijing, Telecommunication Metrology Center of MIIT Address: 3/F Shou Xiang Technology Building, No.51 Xueyuan Road, Hai Dian District, Beijing, P. R. China Postal Code: 100191 Telephone: 00861062304633 Fax: 00861062304793 1.2. Testing Environment Normal Temperature: 15-35°C Relative Humidity: 20-75% 1.3. Project data Testing Start Date: Jul 31, 2012 Testing End Date: Aug 17, 2012 1.4. Signature Zi Xiaogang (Prepared this test report) Sun Xiangqian (Reviewed this test report) Lu Bingsong Deputy Director of the laboratory (Approved this test report) No2012TAR410 Page4 of 58 2. Client Information 2.1. Applicant Information Company Name: ZTE CORPORATION Address /Post: ZTE Plaza, Keji Road South, Hi-Tech Industrial Park, Nanshan District, Shenzhen, Guangdong, 518057, P.R.China City: Shenzhen Country: China Telephone: 0086-21-61460890 Fax: 0086-21-61460602 2.2. Manufacturer Information Company Name: ZTE CORPORATION Address /Post: ZTE Plaza, Keji Road South, Hi-Tech Industrial Park, Nanshan District, Shenzhen, Guangdong, 518057, P.R.China City: Shenzhen Country: China Telephone: 0086-21-61460890 Fax: 0086-21-61460602 No2012TAR410 Page5 of 58 3. Equipment Under Test (EUT) and Ancillary Equipment (AE) 3.1. About EUT Description GSM wireless phone Model Name ZTE WP658 FCC ID Q78-ZTEZTEWP658 Frequency GSM 850MHz; PCS 1900MHz Antenna Internal Power supply Battery or Charger (AC Adaptor) Output power 33.72 dBm maximum ERP measured for GSM850 Ex…

Text truncated - open the document above for the full version.

Test Setup Photos

2012A04672_RSE 12A04672_CE 2012A04672_RE

Contact Information

Applicant

Cary Kong(Product Certification Manager)
[email protected]0086-755-26777740Fax: 0086-755-26770347

Technical Contact

Shanghai Tejet Communications Technology Co., LtdDai Hua
[email protected]

China

Test Firm

TMC-Telecommunication Metrology Center of M.I.I.TChongwen Song
[email protected]0086-10-62303288Fax: 0086-10-62304793

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
224E1.85 GHz - 1.91 GHz743.00 mW300KGXW0.1 ppm
Confidentiality
Long Term
Grant Notes
Power Output is ERP for Part 22 and EIRP for Part 24. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from ZTE Corporation

Home Gateway - FCC ID Q78-E1320 - ZTE Corporation
Q78-E1320

Home Gateway

Oct 06, 2022

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Home Gateway - FCC ID Q78-E3330 - ZTE Corporation
Q78-E3330

Home Gateway

Sep 21, 2022

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
RichMedia Box - FCC ID Q78-ZXV10B866V2 - ZTE Corporation
Q78-ZXV10B866V2

RichMedia Box

May 23, 2021

Equipment Class

DTS - Digital Transmission System
Home Gateway - FCC ID Q78-ZXHNH298Q - ZTE Corporation
Q78-ZXHNH298Q

Home Gateway

Apr 22, 2021

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Home Gateway - FCC ID Q78-ZXHNH196Q - ZTE Corporation
Q78-ZXHNH196Q

Home Gateway

Apr 19, 2021

Equipment Class

NII - Unlicensed National Information Infrastructure TX