Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
ZXCLOUDiBOXCT220 QuickStartGuide ZTECORPORATION No.55,Hi-techRoadSouth,ShenZhen,P.R.China Postcode:518057 Tel:+86-755-26771900 Fax:+86-755-26770801 URL:http://support.zte.com.cn E-mail:[email protected] LEGALINFORMATION Copyright©2013ZTECORPORATION. Thecontentsofthisdocumentareprotectedbycopyrightlawsandinternationaltreaties.Anyreproductionor distributionofthisdocumentoranyportionofthisdocument,inanyformbyanymeans,withoutthepriorwritten consentofZTECORPORATIONisprohibited.Additionally,thecontentsofthisdocumentareprotectedby contractualconfidentialityobligations. Allcompany,brandandproductnamesaretradeorservicemarks,orregisteredtradeorservicemarks,ofZTE CORPORATIONoroftheirrespectiveowners. Thisdocumentisprovided“asis”,andallexpress,implied,orstatutorywarranties,representationsorconditions aredisclaimed,includingwithoutlimitationanyimpliedwarrantyofmerchantability,fitnessforaparticularpurpose, titleornon-infringement.ZTECORPORATIONanditslicensorsshallnotbeliablefordamagesresultingfromthe useoforrelianceontheinformationcontainedherein. ZTECORPORATIONoritslicensorsmayhavecurrentorpendingintellectualpropertyrightsorapplications coveringthesubjectmatterofthisdocument.ExceptasexpresslyprovidedinanywrittenlicensebetweenZTE CORPORATIONanditslicensee,theuserofthisdocumentshallnotacquireanylicensetothesubjectmatter herein. ZTECORPORATIONreservestherighttoupgradeormaketechnicalchangetothisproductwithoutfurthernotice. UsersmayvisitZTEtechnicalsupportwebsitehttp://ensupport.zte.com.cntoinquirerelatedinformation. TheultimaterighttointerpretthisproductresidesinZTECORPORATION. RevisionHistory RevisionNo.RevisionDateRevisionReason R1.22014-03-26Add“2.1,FCCStatement”. R1.12014-02-25Adds“Chapter1,BasicOperions”. R1.02013-03-05Firstedition SerialNumber:SJ-20131018122617-019 PublishingDate:2014-03-26(R1.2) SJ-20131018122617-019|2014-03-26(R1.2)ZTEProprietaryandConfidential AboutThisManual Purpose Thismanualdescribesbasicoperations,configurations,andsystemarchitectureofthe ZXCLOUDiBoxsystem. IntendedAudience Thismanualisintendedforcommonusers. WhatIsinThisManual Thismanualcontainsthefollowingchapters. Chapter1,Basic Operations Describesbasicoperationsonthecloudterminal. Chapter2,Introductionto theCloudTerminal Describesthefunctions,components,connections,configurations, power-on/power-offmethods,packaginglist,andRoHSofthecloud terminal. Conventions Thismanualusesthefollowingconventions. ItalicsVariablesincommands.Itmayalsorefertootherrelatedmanualsanddocuments. BoldMenus,menuoptions,functionnames,inputfields,optionbuttonnames,checkboxes, drop-downlists,dialogboxnames,windownames,parameters,andcommands. Constant width Textthatyoutype,programcodes,filenames,directorynames,andfunctionnames. []Optionalparameters. {}Mandatoryparameters. |Separatesindividualparametersinaseriesofparameters. Danger:indicatesanimminentlyhazardoussituation.Failuretocomplycanresultin deathorseriousinjury,equipmentdamage,orsitebreakdown. Warning:indicatesapotentiallyhazardoussituation.Failuretocomplycanresultin seriousinjury,equipmentdamage,orinterruptionofmajorservices. Caution:indicatesapotentiallyhazardoussituation.Failuretocomplycanresultin moderateinjury,equipmentdamage,orinterruptionofminorservices. Note:providesadditionalinformationaboutatopic. I SJ-20131018122617-019|2014-03-26(R1.2)ZTEProprietaryandConfidential II SJ-20131018122617-019|2014-03-26(R1.2)ZTEProprietaryandConfidential Chapter1 BasicOperations TableofContents LoggingIntotheOperatingSystemofaCloudTerminal............................................1-1 LoggingIntoaVirtualMachineorServer...................................................................1-2 ConfiguringaCloudTerminal.....................................................................................1-6 MonitoringtheNetworkandSystemUsage................................................................ 1-9 DiagnosingtheSystem.............................................................................................1-11 SwitchingtotheAdministrator.................................................................................. 1-12 RestartingorShuttingDowntheCloudTerminal,orPuttingtheCloudTerminalto Sleep........................................................................................................................ 1-14 1.1LoggingIntotheOperatingSystemofaCloud Terminal ThisproceduredescribeshowtologintotheoperatingsystemofaniBOXCT320cloud terminalandperformvariousoperations,forexample,browsingWebpages,logginginto avirtualmachine,settingthecloudterminal,anddiagnosingthesystem. Steps 1.PresstheiBoxpowerbuttontostartthesystem.TheiBOXdesktopisdisplayed,see Figure1-1. 1-1 SJ-20131018122617-019|2014-03-26(R1.2)ZTEProprietaryandConfidential ZXCLOUDiBOXCT220QuickStartGuide Figure1-1iBOXDesktop 2.(Optional)Double-clicktheicon.Thefilemanagerisstartedforfilebrowsing. 3.(Optional)Double-clickthe icon.ThebrowserisstartedforWebpagebrowsing. –EndofSteps– 1.2LoggingIntoaVirtualMachineorServer TheiBOXCT220enablesyoutologintoavirtualmachineorremotelyaccessaserver. lIfthesystemaccessprotocolissettotheSPICEorCitrixprotocol,youcanloginto theoperatingsystemofthevirtualmachinethroughacloudterminal.Youcanlogin toandaccessseveralvirtualmachines. lIfthesystemaccessprotocolissettotheRDPprotocol,youcanremotelyaccessa serverthroughacloudterminal. ThisprocedureusestheSPICEprotocolasanexampletodescribehowtologintoa virtualmachine. 1-2 SJ-20131018122617-019|2014-03-26(R1.2)ZTEProprietaryandConfidential Chapter1BasicOperations Steps 1.Clickthe icononthedesktop.TheSightersoftwareisstarted,seeFigure1-2. Figure1-2ZTESighterDialogBox 2.Clicktheicon.Thevirtualmachinelogindialogboxisdisplayed,seeFigure1-3. 1-3 SJ-20131018122617-019|2014-03-26(R1.2)ZTEProprietaryandConfidential ZXCLOUDiBOXCT220QuickStartGuide Figure1-3VirtualMachineLoginDialogBox 3.Entertheusernameandpassword.Foradescriptionoftheparameters,refertoTable 1-1. Table1-1ParameterDescriptionsfortheLoginDialogBox ParameterDescriptions UserNameEntertheusernametologintothevirtu…
Text truncated - open the document above for the full version.
RF_160, Issue 02 Declaration of Authorization We Name: ZTE Corporation Address: ZTE Plaza, Hi-tech Park, Nanshan District, City: Shenzhen, Guangdong Country: China Declare that: Name Representative of agent: Ms. Cathy Wang Agent Company name: Neutron Engineering, Inc. Address: No.3 Jinshagang 1 st Road, Shixia, Dalang Town City: Dongguan Country: China is authorized to apply for Certification of the following product(s), including the signing of 731 form: Product description: Cloud Terminal (microcomputer) Type designation: ZXCLOUD CT220 Trademark: ZTE 中兴; ZTE on our behalf. Date: 2013-11-14 City: Shenzhen Name: Royce Wang Function: Product Certification Manager Signature: . Notes: (1): Required for FCC application (2): For FCC it must be the Grantee Code “owner” or the authorized agent.
FCC, Request for non-disclosure Date: 10-AUG-09 RF_501, Issue 5 Page 1 of 1 Company Name: ZTE Corporation Address: ZTE Plaza, Hi-tech Park, Nanshan District, City: Shenzhen, Guangdong Country: China To: Telefication B.V., Dept. FCC TCB Edisonstraat 12A 6902 PK ZEVENAAR The Netherlands Subject: Request for confidentiality FCC ID: Q78-ZXCLDCT220 Reference number: ###### Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, applicant hereby requests Short-Term Confidential treatment of the following materials (note 1): Internal Photos User’s Manual Test Set-up Photos External Photos Justification: Planned Release Date STC: (notes 2, 3, 4, 5) Date: 2013-11-14 Name and signature of applicant: Royce Wang Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)! 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! 5) Request for extension or for release must be received by Telefication at least 7 days before date of actual marketing or before expiration of the STC period
CERTIFICATE OF COMPLIANCE Authorized under Declaration of Conformity according to 47 CFR, Part 2 and Part 15 of the FCC Rules. The product listed in follows was (were) tested in the Neutron EMC Laboratory to comply with the criteria limits Class B of conducted and radiated emissions of the Technical Standards FCC Part 15, Subpart B, established by the FCC, USA. Equipment Cloud Terminal (microcomputer) Model Name ZXCLOUD CT220 Brand Name ZTE 中兴, ZTE Applicant ZTE Corporation Address ZTE Plaza, Hi-Tech Park, Nanshan District, Shenzhen, Guangdong, P.R.China Standard(s) FCC Part 15, Subpart B: 2012 ANSI C63.4 -2009 Report(s) NEI-FCCE-1-1311C085 The test data, data evaluation, and equipment configuration contained in our test report(s) above was(were) obtained utilizing the test procedures, test instruments, test sites that has been accredited by the Authority of TAF according to the ISO-17025 quality assessment standard and technical standard(s). The test data contained in the referenced test report relate only to the EUT sample and item(s) tested. Andy Chiu Authorized Signatory Neutron Engineering Inc. B1, No.37, Lane 365, Yang Guang St., NeiHu District 114., Taipei, Taiwan TEL:+886-2-2657-3299 FAX:+886-2-2657-3331
Neutron Engineering Inc. Project No.: 1311C085 Page 2 of 11 Neutron Engineering Inc. Project No.: 1311C085 Page 3 of 11 Neutron Engineering Inc. Project No.: 1311C085 Page 4 of 11
ODEHOORFDWLRQ
Neutron Engineering Inc. Project No.: 1311C085 Page 5 of 11 Neutron Engineering Inc. Project No.: 1311C085 Page 6 of 11 Neutron Engineering Inc. Project No.: 1311C085 Page 7 of 11 Neutron Engineering Inc. Project No.: 1311C085 Page 8 of 11 Neutron Engineering Inc. Project No.: 1311C085 Page 9 of 11 Neutron Engineering Inc. Project No.: 1311C085 Page 10 of 11 Neutron Engineering Inc. Project No.: 1311C085 Page 11 of 11
Neutron Engineering Inc. FCC RF EXPOSURE REPORT FCC ID: Q78-ZXBOXCT220 Project No. : 1311C085 Equipment : Cloud Terminal (microcomputer) Model : ZXCLOUD CT220 Applicant : ZTE Corporation Address : ZTE Plaza, Hi-Tech Park, Nanshan District, Shenzhen, Guangdong, P.R. China According: : FCC Guidelines for Human Exposure IEEE C95.1 Neutron Engineering Inc. No.3, Jinshagang 1st Road, ShiXia, Dalang Town, Dong Guan, China. TEL : (0769) 8318-3000 FAX : (0769) 8319-6000 Neutron Engineering Inc. MPE CALCULATION METHOD: Calculation Method of RF Safety Distance: where: S = power density P = power input to the antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna Table for Filed Antenna Ant. Brand Model Name Antenna TypeConnector Gain (dBi) Note 1 N/A N/A Integral N/A 4.54 TX/RX Neutron Engineering Inc. TEST RESULTS EUT: Cloud Terminal (microcomputer) Model Name : ZXCLOUD CT220 Temperature: 25 °C Relative Humidity: 55 % Test Voltage AC 120V/60Hz Test Mode : TX B MODE Antenna Gain (dBi) Antenna Gain (numeric) Peak Output Power (dBm) Peak Output Power (mW) Power Density (S) (mW/cm 2 ) Limit of Power Density (S) (mW/cm 2 ) Te s t Result 4.54 2.8445 20.09 102.0939 0.057803001 Complies 4.54 2.8445 20.05 101.1579 0.057273061 Complies 4.54 2.8445 20.01 100.2305 0.056747981 Complies EUT: Cloud Terminal (microcomputer) Model Name : ZXCLOUD CT220 Temperature: 25 °C Relative Humidity: 55 % Test Voltage AC 120V/60Hz Test Mode : TX G MODE Antenna Gain (dBi) Antenna Gain (numeric) Peak Output Power (dBm) Peak Output Power (mW) Power Density (S) (mW/cm 2 ) Limit of Power Density (S) (mW/cm 2 ) Te s t Result 4.54 2.8445 24.54 284.4461 0.161046161 Complies 4.54 2.8445 24.67 293.0893 0.165939731 Complies 4.54 2.8445 24.62 289.7344 0.164040231 Complies Neutron Engineering Inc. EUT: Cloud Terminal (microcomputer) Model Name : ZXCLOUD CT220 Temperature: 25 °C Relative Humidity: 55 % Test Voltage AC 120V/60Hz Test Mode : TX N-20M MODE Antenna Gain (dBi) Antenna Gain (numeric) Peak Output Power (dBm) Peak Output Power (mW) Power Density (S) (mW/cm 2 ) Limit of Power Density (S) (mW/cm 2 ) Te s t Result 4.54 2.8445 20.63 115.6112 0.065456141 Complies 4.54 2.8445 24.45 278.6121 0.157743101 Complies 4.54 2.8445 24.43 277.3320 0.157018341 Complies EUT: Cloud Terminal (microcomputer) Model Name : ZXCLOUD CT220 Temperature: 25 °C Relative Humidity: 55 % Test Voltage AC 120V/60Hz Test Mode : TX N-40M MODE Antenna Gain (dBi) Antenna Gain (numeric) Peak Output Power (dBm) Peak Output Power (mW) Power Density (S) (mW/cm 2 ) Limit of Power Density (S) (mW/cm 2 ) Te s t Result 4.54 2.8445 18.82 76.2079 0.043146981 Complies 4.54 2.8445 24.29 268.5344 0.152037381 Complies 4.54 2.8445 20.27 106.4143 0.060249071 Complies Note: the calculation distance is 20cm.
Neutron Engineering Inc. Report No.: NEI-FCCP-1-1311C085 Page 1 of 106 FCC Radio Test Report FCC ID: Q78-ZXCLDCT220 This report concerns (check one): Original Grant Class II Change Issued Date : Mar. 19, 2014 Project No. : 1311C085 Equipment : Cloud Terminal (microcomputer) Model Name : ZXCLOUD CT220 Applicant : ZTE Corporation Address : ZTE Plaza, Hi-Tech Park, Nanshan District, Shenzhen, Guangdong, P.R.China Tested by: Neutron Engineering Inc. EMC Laboratory Date of Receipt: Nov. 11, 2013 Date of Test: Nov. 11, 2013 ~ Mar. 14, 2014 Testing Engineer : (David Mao) Technical Manager : (Leo Hung) Authorized Signatory: (Steven Lu) Neutron Engineering Inc. No.3,Jinshagang 1st Road, ShiXia, Dalang Town, Dong Guan, China. TEL: 0769-8318-3000 FAX: 0769-8319-6000 Neutron Engineering Inc. Report No.: NEI-FCCP-1-1311C085 Page 2 of 106 Declaration Neutron represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with the standards traceable to National Measurement Laboratory (NML) of R.O.C, or National Institute of Standards and Technology (NIST) of U.S.A. Neutron's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. Neutron shall have no liability for any declarations, inferences o r generalizations drawn by the client or others from Neutron issued reports. Neutron’s reports must not be used by the client to claim product endorsement by the authorities or any agency of the Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and Neutron-self, extracts from the test report shall not be reproduced except in full with Neutron’s authorized written approval. Neutron’s laboratory quality assurance procedures are in compliance with the ISO Guide 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Neutron Engineering Inc. Report No.: NEI-FCCP-1-1311C085 Page 3 of 106 Table of Contents Page 1 . CERTIFICATION 6 2 . SUMMARY OF TEST RESULTS 7 2.1 TEST FACILITY 8 2.2 MEASUREMENT UNCERTAINTY 8 3 . GENERAL INFORMATION 9 3.1 GENERAL DESCRIPTION OF EUT 9 3.2 DESCRIPTION OF TEST MODES 11 3.3 TABLE OF PARAMETERS OF TEXT SOFTWARE SETTING 12 3.4 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 13 3.5 DESCRIPTION OF SUPPORT UNITS 14 4 . EMC EMISSION TEST 15 4.1 CONDUCTED EMISSION MEASUREMENT 15 4.1.1 POWER LINE CONDUCTED EMISSION LIMITS 15 4.1.2 TEST PROCEDURE 15 4.1.3 DEVIATION FROM TEST STANDARD 15 4.1.4 TEST SETUP 16 4.1.5 EUT OPERATING CONDITIONS 16 4.1.6 EUT TEST CONDITIONS 16 4.1.7 TEST RESULTS 16 4.2 RADIATED EMISSION MEASUREMENT 19 4.2.1 RADIATED EMISSION LIMITS 19 4.2.2 TEST PROCEDURE 20 4.2.3 DEVIATION FROM TEST STANDARD 20 4.2.4 TEST SETUP 21 4.2.5 EUT OPERATING CONDITIONS 22 4.2.6 EUT TEST CONDITIONS 22 4.2.7 TEST RESULTS (9K~ 30MHZ) 23 4.2.8 TEST RESULTS (BETWEEN 30 – 1000 MHZ) 24 4.2.9 TEST RESULTS (ABOVE 1000 MHZ) 31 5 . BANDWIDTH TEST 60 5.1 APPLIED PROCEDURES 60 5.1.1 TEST PROCEDURE 60 5.1.2 DEVIATION FROM STANDARD 60 5.1.3 TEST SETUP 60 5.1.4 EUT OPERATION CONDITIONS 60 5.1.5 EUT TEST CONDITIONS 60 5.1.6 TEST RESULTS 61 Neutron Engineering Inc. Report No.: NEI-FCCP-1-1311C085 Page 4 of 106 Table of Contents Page 6 . MAXIMUM OUTPUT POWER TEST 69 6.1 APPLIED PROCEDURES / LIMIT 69 6.1.1 TEST PROCEDURE 69 6.1.2 DEVIATION FROM STANDARD 69 6.1.3 TEST SETUP 69 6.1.4 EUT OPERATION CONDITIONS 69 6.1.5 EUT TEST CONDITIONS 69 6.1.6 TEST RESULTS 70 7 . ANTENNA CONDUCTED SPURIOUS EMISSION 71 7.1 APPLIED PROCEDURES / LIMIT 71 7.1.1 TEST PROCEDURE 71 7.1.2 DEVIATION FROM STANDARD 71 7.1.3 TEST SETUP 71 7.1.4 EUT OPERATION CONDITIONS 71 7.1.5 EUT TEST CONDITIONS 71 7.1.6 TEST RESULTS 72 8 . POWER SPECTRAL DENSITY TEST 92 8.1 APPLIED PROCEDURES / LIMIT 92 8.1.1 TEST PROCEDURE 92 8.1.2 DEVIATION FROM STANDARD 92 8.1.3 TEST SETUP 92 8.1.4 EUT OPERATION CONDITIONS 92 8.1.5 EUT TEST CONDITIONS 92 8.1.6 TEST RESULTS 93 9 . MEASUREMENT INSTRUMENTS LIST 101 10 . EUT TEST PHOTO 103 Neutron Engineering Inc. Report No.: NEI-FCCP-1-1311C085 Page 5 of 106 REPORT ISSUED HISTORY Issued No. Description Issued Date NEI-FCCP-1-1311C085 Original Issue. Mar. 19, 2014 Neutron Engineering Inc. Report No.: NEI-FCCP-1-1311C085 Page 6 of 106 1. CERTIFICATION Equipment : Cloud Terminal (microcomputer) Brand Name : ZTE 中兴, ZTE Model Name : ZXCLOUD CT220 Applicant : ZTE Corporation Manufacture : ZTE Corporation Address : ZTE Plaza, Hi-Tech Park, Nanshan District, Shenzhen, Guangdong, P.R.China Factory : ZTE Corporation Address : ZTE Plaza, Hi-Tech Park, Nanshan District, Shenzhen, Guangdong, P.R.China Date of Test : Nov. 11, 2013 ~ Mar. 14, 2014 Test Item : ENGINEERING SAMPLE Standard(s) : FCC Part15, Subpart C(15.247) / ANSI C63.4-2009 The above equipment has been tested and found compliance with the requirement of the relative standards by Neutron Engineering Inc. EMC Laboratory. The test data, data evaluation, and equipment configuration contained in our test report (Ref No. NEI-FCCP-1-1311C085) were obtained utilizing the test procedures, test instruments, test sites that has been accredited by the Authority of TAF according to the ISO-17025 quality assessment standard and technical standard(s). Neutron Engineering Inc. Report No.: NEI-FCCP-1-1311C085 Page 7 of 106 2. SUMMARY OF TEST RESULTS Test procedures according to the technical standard(s): Applied Standard(s): FCC Part15 (15.247) , Subpart C Standard(s) Section FCC Test Item Judgment Remark 15.207 Conducted Emission PASS 15.247(d) Antenna conducted Spurious Emission PASS 15.247(a)(…
Text truncated - open the document above for the full version.
Neutron Engineering Inc. Report No.: NEI-FCCP-1-1311C085 Page 103 of 106 10. EUT TEST PHOTO Conducted Measurement Photos Neutron Engineering Inc. Report No.: NEI-FCCP-1-1311C085 Page 104 of 106 Radiated Measurement Photos 9K~30MHz Neutron Engineering Inc. Report No.: NEI-FCCP-1-1311C085 Page 105 of 106 Radiated Measurement Photos 30~1000MHz Neutron Engineering Inc. Report No.: NEI-FCCP-1-1311C085 Page 106 of 106 Radiated Measurement Photos Above 1000MHz
China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 290.00 mW |

Home Gateway
Equipment Class
NII - Unlicensed National Information Infrastructure TX
Home Gateway
Equipment Class
JBP - Part 15 Class B Computing Device Peripheral
RichMedia Box
Equipment Class
DTS - Digital Transmission System
Home Gateway
Equipment Class
NII - Unlicensed National Information Infrastructure TX
Home Gateway
Equipment Class
NII - Unlicensed National Information Infrastructure TX