QRKHI469112SARS MP9112 134 kHz Proximity Reader

SAMSys Technologies, Inc.
SARS MP9112 134 kHz Proximity Reader - FCC ID QRKHI469112 - SAMSys Technologies, Inc.
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Apr 29, 2003
Application Purpose
Original Equipment
Date of Application
Apr 29, 2003
Equipment Note
SARS MP9112 134 kHz Proximity Reader
Frequency Range
0.13450000 - 0.13450000
Company
SAMSys Technologies, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Owner’s Manual SARS MP9112 134 KHz Proximity Reader Owner’s Manual SARS MP9112 134 KHz Proximity Reader SAMSys SARS MP9112 134 KHz Proximity Reader Owner’s Manual Second Edition (April 2003) © Copyright 2003 SAMSys Technologies, Inc. All Rights Reserved. Disclaimer and Limitation of Liability The content of this manual is for information use only and is subject to change without notice. SAMSys assumes no responsibility or liability for any errors or inaccuracies that may appear in this publication. No part of this manual may be reproduced in any form or by any means, electronic, mechanical, recording, or otherwise, without the prior written permission of SAMSys. SAMSys products are not designed, intended, authorized or warranted to be suitable for life support applications or any other life critical applications which could involve potential risk of death, personal injury, property damage, or environmental damage. About SAMSys SAMSys is the world leader in the design and supply of radio frequency identification (RFID) hardware solutions for high volume pallet and reusable container tracking applications in global logistics management, materials handling, and supply chain industries. SAMSys is a public company listed on the Canadian Venture Exchange under the symbol SMY. SAMSys Technologies, Inc. 44 East Beaver Creek Rd., Unit 11 Richmond Hill, Ontario L4B 1G8 Canada Phone: (905) 707-0404 Toll Free: (877) 463-6546 Fax: (905) 707-9944 E-mail: [email protected] Web: www.samsys.com Part Number: HI469-112-OM-V2 Federal Communications Commission (FCC) Notice This device was tested and found to comply with the limits set forth in Part 15 of the FCC Rules. Operation is subject to the following conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received including interference that may cause undesired operation. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This device generates, uses, and can radiate radio frequency energy. If not installed and used in accordance with the instruction manual, the product may cause harmful interference to radio communications. Operation of this product in a residential area is likely to cause harmful interference, in which case, the user is required to correct the interference at their own expense. The authority to operate this product is conditioned by the requirements that no modifications be made to the equipment unless the changes or modifications are expressly approved by SAMSys Technologies. Trademarks SAMSys is a trademark of SAMSys Technologies, Inc. HyperTerminal is a registered trademark of Hilgraeve, Inc. Other company, product or service names appearing in this manual may be trademarks or service marks of their respective owners. SARS MP9112 Owner’s Manual i Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Unpacking the Reader . . . . . . . . . . . . . . . . . . . . . . . 2 About the SARS MP9112 . . . . . . . . . . . . . . . . . . . . 3 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Physical Description . . . . . . . . . . . . . . . . . . . . . . . . 5 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Reader Installation . . . . . . . . . . . . . . . . . . . . . . . . . . 9 RS-232 Communication Setup . . . . . . . . . . . . . . . . 10 RS-485 Communication Setup . . . . . . . . . . . . . . . . 11 Digital (TTL) Input/Output Setup . . . . . . . . . . . . . . 12 External Antenna Installation . . . . . . . . . . . . . . . . . 13 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Reader Power Up . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Reading Tags . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Operation with the ICCM . . . . . . . . . . . . . . . . . . . . 20 Operation with a Terminal Emulation Program . . . 20 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 General Troubleshooting . . . . . . . . . . . . . . . . . . . . . 22 Contact Us . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Reader Specifications . . . . . . . . . . . . . . . . . . . . . . . 27 Environmental Specifications . . . . . . . . . . . . . . . . . 27 Power Supply Specifications . . . . . . . . . . . . . . . . . . 28 Digital I/O Connector Specifications . . . . . . . . . . . . 28 RS-232 Connector Specifications . . . . . . . . . . . . . . 29 RS-485 Connector Specifications . . . . . . . . . . . . . . 30 SARS MP9112 Owner’s Manual ii Figures Reader and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . 2 SARS Reader Network . . . . . . . . . . . . . . . . . . . . . . . . . 4 Reader Board and Enclosure . . . . . . . . . . . . . . . . . . . . . 5 Reader LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . 6 Reader End-Panel Connectors . . . . . . . . . . . . . . . . . . . . 7 Horizontal Surface Installation . . . . . . . . . . . . . . . . . . . 9 RS-485 Cable Installation . . . . . . . . . . . . . . . . . . . . . . . 12 External Antenna Installation . . . . . . . . . . . . . . . . . . . . 13 External Antenna Jumpers on MP9112 Reader Board . 15 LED Indicators - Reader Operational . . . . . . . . . . . . . . 19 LED Indicators - Tag Successfully Read . . . . . . . . . . . . 19 Digital I/O Connector . . . . . . . . . . . . . . . . . . . . . . . . . . 28 RS-232 Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 RS-485 Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 1 1 Introduction This chapter provides a general description of the SARS MP9112. Topics discussed in this ch…

Text truncated - open the document above for the full version.

Cover Letter(s)

. . . . . . . . www.samsys.com 2525 Meridian Parkway, Ste 60 Durham, North Carolina USA 27713 Phone: (919) 281-1541 Toll Free:(877) 367-4342 Fax: (919) 281-1551 44 E. Beaver Creek Rd., Unit 11 Richmond Hill, Ontario Canada L4B 1G8 Phone: (905) 707-0404 Toll Free:(888) 483-6646 Fax: (905) 707-9944 SAMSys Technologies, Inc. April 2, 2003 TUV Rheinland of North America, Inc. 762 Park Avenue Youngsville, NC 27596 Dear Sir or Madam: Please be advised that SAMSys Technologies Incorporated authorizes TUV compliance Laboratories to act on our behalf. We certify that SAMSys Technologies, Incorporated is not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse ACT of 1988, U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002(b), to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you for your attention to this matter. Clifton D. Morgan Product Support Manager SAMSys Technologies, Inc [email protected] 919-281-1559

Test Report

Report Number: 5071sam1 Page 1 of 45 EUT: SARS MP9112 Model: HI469-112 33_EME/I 01/29/2001 FCC ID: QRKHI469112 Emissions Test Report EUT Name: SARS MP9112 EUT Model: HI469-112 FCC Title 47, Part 15, SubpartC, RSS-210 Issue 5 Prepared for: Clifton Morgan Samsys Technologies 2525 Meridian Parkway, Suite 60 Durham, NC 27713 Tel: 919-281-1559 Fax: 919-281-1551 Prepared by: Flextronics Compliance Laboratories 762 Park Avenue Youngsville, NC 27596 Tel: (919) 554-0901 Fax: (919) 556-2043 http://www.flextronics.com/ Report/Issue Date: 15 April 2003 Report Number: 5071sam1 Statement of Compliance Report Number: 5071sam1 Page 2 of 45 EUT: SARS MP9112 Model: HI469-112 33_EME/I 01/29/2001 FCC ID: QRKHI469112 Manufacturer: Samsys Technologies 2525 Meridian Parkway, Suite 60 Durham, NC 27713 919-281-1559 Requester / Applicant: Clifton Morgan Name of Equipment: SARS MP9112 Model No. HI469-112 Type of Equipment: Intentional Radiator Application of Regulations: FCC Title 47, Part 15, SubpartC, RSS-210 Issue 5 Test Dates: 29 October, 2002 to 29 October, 2002 Guidance Documents: Emissions: FCC 47 CFR Part 15, RSS-210 Issue 5 Test Methods: Emissions: ANSI C63.4:1992 The electromagnetic compatibility test and documented data described in this report has been performed and recorded by Flextronics Compliance Laboratories, in accordance with the standards and procedures listed herein. As the responsible authorized agent of the EMC laboratory, I hereby declare that a sample of one, of the equipment described above, has been shown to be compliant with the EMC requirements of the stated regulations and standards based on these results. If any special accessories and/or modifications were required for compliance, they are listed in the Executive Summary of this report. This report must not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. This report contains data that are not covered by NVLAP accreditation. This report shall not be reproduced except in full, without the written authorization of the laboratory. 15 April 2003 Steve O'Steen Date Operations Manager NVLAP Signatory Table of Contents Report Number: 5071sam1 Page 3 of 45 EUT: SARS MP9112 Model: HI469-112 33_EME/I 01/29/2001 FCC ID: QRKHI469112 1 EXECUTIVE SUMMARY.......................................................................................................4 1.1 SCOPE.................................................................................................................................4 1.2 PURPOSE.............................................................................................................................4 1.3 SUMMARY OF TEST RESULTS................................................................................................4 1.4 SPECIAL ACCESSORIES.........................................................................................................4 1.5 EQUIPMENT MODIFICATIONS................................................................................................4 2 LABORATORY INFORMATION...........................................................................................4 2.1 ACCREDITATIONS & ENDORSEMENTS...................................................................................4 2.2 TEST FACILITIES..................................................................................................................5 2.3 MEASUREMENT UNCERTAINTY.............................................................................................6 2.4 CALIBRATION TRACEABILITY...............................................................................................7 3 PRODUCT INFORMATION...................................................................................................7 3.1 PRODUCT DESCRIPTION......................................................................................................14 3.2 EQUIPMENT CONFIGURATION.............................................................................................14 3.3 OPERATION MODE.............................................................................................................15 4 EMISSIONS...........................................................................................................................15 4.1 RADIATED EMISSIONS........................................................................................................15 4.2 CONDUCTED EMISSIONS.....................................................................................................27 5 TEST EQUIPMENT USE LIST.............................................................................................37 6 EMC TEST PLAN..................................................................................................................38 Flextronics Compliance Laboratories Scope 762 Park Ave., Youngsville, NC 27596 Tel: (919) 554-0901, Fax: (919) 556-2043 Report Number: 5071sam1 Page 4 of 45 EUT: SARS MP9112 Model: HI469-112 33_EME/I 01/29/2001 FCC ID: QRKHI469112 1 Executive Summary 1.1 Scope This report is intended to document the status of conformance with the requirements of the FCC Title 47, Part 15, SubpartC, RSS-210 Issue 5 based on the results of testing performed on 29 October, 2002 through 29 October, 2002 on the SARS MP9112 Model No. HI469-112 manufactured by Samsys Technologies. This report only applies to the specific samples tested under the stated test conditions. It is the responsibility of the manufacturer to assure that additional production units of this model are manufactured with identical or EMI equivalent electrical and mechanical components. This report is further intended to document changes and modifications to the EUT throughout its life cycle. All documentation will be included as a supplement. 1.2 Purpose Testing was performed to evaluate the EMC performance of the EUT in accordance with the applicable requirements, procedures, and criteria defined in the application of regulations and ap…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Clifton D Morgan(Product Support Manager)
[email protected]919-281-1559Fax: 919-281-1551

Technical Contact

Samsys Technologies, Inc.Marv Baker
[email protected]919-281-1559

2525 Meridian Parkway · Durham, North Carolina · United States

Non-Technical Contact

Samsys Technologies, Inc.Ian Chalmers
[email protected]919-281-1559

Test Firm

TUV Rheinland of North AmericaMichael Moranha
[email protected]919-554-0901Fax: 919-554-3542

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.1345 MHz - 0.1345 MHz-
Confidentiality
Long Term

Other Applications from SAMSys Technologies, Inc.

MP9320 2.8 UHF 4-PORT RFID READER - FCC ID QRKH1469320 - SAMSys Technologies, Inc.
QRKH1469320

MP9320 2.8 UHF 4-PORT RFID READER

Jun 29, 2005

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
RFID Transmitter - FCC ID QRKHI469310 - SAMSys Technologies, Inc.
QRKHI469310

RFID Transmitter

Feb 08, 2005

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
UHF Long Range Reader - FCC ID QRKHI469320 - SAMSys Technologies, Inc.
QRKHI469320

UHF Long Range Reader

Aug 21, 2003

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
High Frequency RFID Proximity Reader - FCC ID QRKHI469210 - SAMSys Technologies, Inc.
QRKHI469210

High Frequency RFID Proximity Reader

Jun 11, 2003

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
SARS MP9111 125 kHz Proximity Reader - FCC ID QRKHI469111 - SAMSys Technologies, Inc.
QRKHI469111

SARS MP9111 125 kHz Proximity Reader

Apr 28, 2003

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz