
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CAUTION: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
SAVERCAlL-1000 Motion Detector (HJ-MD100F)
External Photo Motion Detector
Label Information <Motion Detector : QUPHJ-MD100F> Label is attached on the rear of product The Label shown shall be permanently affixed at a conspicuous location on the device and be readily visible to the user at the time of purchase. FCC ID : QUPHJ-MD100F THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS; (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE. AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED. INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
Internal Photo Motion Detector Internal Photo Internal Photo
Operation Manual This product informs emergency situation to user using wired te lephone line when produce invader, fire occur- rence using wireless sensors and emergency situation using wire less remote controller (include necklace style remote controller). And also it is a stand-alone radio alarm sy stem that can drive out invaders. Sensor part Main frame part Telephone listener part Sensor (include remote controller) transmits data by protocol predefined at in-vader, door open, occurrence of fire or emergency situation occurrence to main frame us-ing RF Transmitter. -> Main frame examines whether fit to protocol that receive RF signal that sensors (include re-mote controller) sends a letter through RF Receiver of main frame and is predefined. If is sensor or remote controller that is registered in main frame, main frame calls by stored telephone number beforehand. (At this time, according to user option or state of main frame, wired siren can act.) -> If listener receives telephone that is made from main frame, recorded beforehand user's ad-dress or message is played and manufacturing guidance voice is played continuously. This time, listener can do manufacturing such as tapping, arming side conversation, siren on/off, change main frame working mode and etc. using DTMF that happen by that press telephone button.
55 44 33 22 11 D D C C B B A A SWITCH HYUN JOUNG SYSTEM/CHANGSUN YUN DIODE LED POWER PIR SENSOR LOW BAT OFF TEST POINT RF TXMICOM ON BUZZER THERMISTOR 2 B 1 3 Drain 2 1-GND E RE03B 2 Source HT7133 Top view C Frontview 1 TR 3 1 ELM742A(A36) 2-VIN 3 2 Ground 3-VOUT 4 3 5 1 RF_IN HJ-20021115 00 MOTION DETECTOR B 11 Tuesday, December 03, 2002 TitleSize Document Number Rev Date: Sheet of DATA OP_ON VCC LED SENSOR VCC SENSORBUZZER RF_POWER RF_POWER BUZZER SENSOR OP_ON LOW_BAT STROBEPDATA/LOW_BATCLOCKDATA RF_POWERRF_IN OP_ON STROBEPDATACLOCK LATCH LATCHPDATACLOCKSTROBE LATCH BUZZERLED ANT DATA TX_DATA Vref/THERMISTOR Vref/THERMISTOR RF_INVCC+3.3VVCC+6V RF_POWER LOW_BAT RF_IN VCC+6V VCC+3.3V VCC+6V VCC+6V VCC+3.3V VCC+3.3V VCC+3.3V VCC+6V VCC+6V VCC+6V VCC+3.3V VCC+3.3V VCC+3.3V VCC+3.3V VCC+3.3V TP2 1 C18 100n 1 C1 none U1 TK71730S 123 45 INGNDCONT N/B OUT C815p C4 220n C1015p C15 100n R17 120k R6 10k TP3 1 C11 100n R12 470Ohm 1 Q5HT7133 2 1 3 VIN GND VOUT C7none SW1 SW KEY-Y1011 1 3 2 RF_TX1FM 433.920MHz TX 12 3456789 ANT GND TX_LOCKTX_LATCHTX_DATAVCCGNDPLL_DATAPLL_CLK R13 100k R7 100 Ohm D21N5819 1 2 BAT1 CON1 12 C610n + C916V/22uF C121n Q3C3875 2 3 1 PZ1KPX-1205 21 1 TP6 1 R10 68k R18 0 Ohm C16 15p t TH1none 12 L2ANTENA R2none Q2none 2 3 1 TP1 1 R4 220k Q1none 2 1 3 1 R810k R15 220k + C1310uF/16V C5 100n D1 LED 12 C3 10n BAT2 CON1 12 + C14 10uF/16V 1 R14 560k +- U4 ELM742A( A36) 31 4 25 + C1716V/22uF U3 PIC16C711 123456789 101112131415161718 RA2/AN2RA3/AN3/VREFRA4/T0CK1MCLR/VPP VSSRB0/INTRB1RB2RB3 RB4 RB5RB6RB7 VDD OSC2/CLKOUT OSC1/CLKIN RA0/AN0RA1/AN1 R5 none R110k R9 220k C2 220n R16 220k R32M R192M 1 R20 150k R11 150k U2RE03B 1 2 3 DS G Y1 4.0M TP4 1 D3none 12 Q42SC4226 2 3 1 TP5 1 1
TEST REPORT Date : 2003-02-13 No. : BRF-0302002 Page 1 of 9 APPLICANT : Hyun Joung System Co., Ltd. No. 302, 2 nd ACE Techno Tower, 197-7, Guro-dong, Guro-gu, Seoul, Korea DATE OF SMAPLES RECEIVED : Dec. 06, 2002 TEST DURATION : Dec. 16, 2002 ∼ Feb. 7, 2003 DESCRIPTION OF SAMPLE (S) : A sample of product said to be : Product : Motion Detector Manufacturer : Hyun Joung System Co., Ltd. Model Number : HJ-MD100F Type of Modulation : FSK Frequency Range : 433.425MHz – 434.415MHz Tx Antenna Type : Integral No. of Units : 1Tx Rating : 6V DC (AA Alkaline x 4) – 3V Regulating Voltage Origin : Korea INVESTIGATIONS REQUESTED : Measurement to the relevant clauses of F.C.C. Rules and Regulations Part15 Subpart C – Intentional Radiator. TEST PROCEDURE ANSI C63.4-2000 RESULT / REMARK : Please see attached sheet(s). CONCLUSION : From the measurement data obtained, the tested sample was considered to have COMPLIED with the clause 15.231 for the Transmitter Section of Federal Communications Commission Rules, Clause 15.231 (a), (b) & (c). TEST REPORT Date : 2003-02-13 No. : BRF-0302002 Page 2 of 9 TEST EQUIPMENT AUDIT : 2003. 02. 13 2003. 02. 13 Testing by M.J. Byun Approval by C.A.Kwon TEST SUMMARY (1) Measurement of Emission of RF energy on the carrier frequency...................... Satisfactory Measurement of the out-of band emissions including harmonics........................ Satisfactory (2) Measurement of Emission Within Band Edges............................................... Satisfactory (3) Measurement of Radiated Emissions........................................................... Not Applicable (4) Measurement of Line-Conducted Voltage onto AC Power Line.......................... Not Applicable (5) FCC rule clause 15.231 (a), (b) and (c) subpart C– Intentional-radiator................. Satisfactory TEST DATA Please refer to the attached result sheets. TEST REPORT Date : 2003-02-13 No. : BRF-0302002 Page 3 of 9 INTENTIONAL RADIATOR (MOTION DETECTOR ) (1) Measurement of Radiated Interference TEST REFERENCE :FCC Rule Part 15 Section 15.231 (433.92MHz) TEST CONDITION : Normal TEST DATE : 2002. 12. 16 ∼ 12. 18 Emission of RF energy on the carrier frequency –433.92MHz Emission Frequency Reading (Peak Value) Polarization Antenna Factor & Cable Loss Amp Gain Average Factor Field Strength (at 3m) FCC Limit MHz dB() H-V dB dB dB dB(/m) dB(/m) 433.92 71.2 H 21.7 -27.3 -4.4 61.2 80.825 Calculation of the field strength limits by linear interpolation (F=433.92) Field strength limit of the fundamental frequency: Limit = (F-260)*(12500-3750)/(470-260) + 3750 = 10996.6/m = 80.825 dB/m Field strength limit of spurious emissions: Limit = (F-260)* (1250-375)/(470-260) + 375 = 1099.6/m = 60.825 dB/m Field strength of spurious emissions Emission Frequency Reading (Peak Value) Polarization Antenna Factor & Cable Loss Amp Gain Average Factor Field Strength (at 3m) FCC Limit MHz dB() H-V dB dB dB dB(/m) dB(/m) 867.82 14 V 30.6 -26.7 -4.4 13.5 60.825 *1301.76 < 10 31.7 -26.7 -4.4 < 10.6 54 1735.68 < 10 35.3 -26.6 -4.4 < 14.3 60.825 2169.6 < 10 36.6 -26.4 -4.4 < 15.8 60.825 2603.52 < 10 36.9 -26.4 -4.4 < 16.1 60.825 3037.44 < 10 37.6 -26.3 -4.4 < 16.0 60.825 3471.36 < 10 38.7 -26.3 -4.4 < 18.0 60.825 *3905.28 < 10 39.3 -26.2 -4.4 < 18.7 54 *4339.2 < 10 40.5 -26.2 -4.4 < 19.9 54 TEST REPORT Date : 2003-02-13 No. : BRF-0302002 Page 4 of 9 Remark: *-Denotes restricted band of operation. Measurement were made using a peak detector. Any emission less than 1000MHz and falling within the restricted bands of FCC Rules Part 15 Section 15.205 were not adjusted for averaging and the limit of FCC Rules Part15 Section 15.209 were applied. ========== SUMMARY========== Data is within limits Broad-band Antennas were used and both polarizations of emissions were measured. Polarizations at highest reading indicated as; H—Horizontal V--Vertical TEST REPORT Date : 2003-02-13 No. : BRF-0302002 Page 5 of 9 INTENTIONAL RADIATOR(MOTION DETECTOR) (2) Measurement of Emissions Within Band Edges. (Continued) TEST REFERENCE :FCC Rules Part 15 Section 15.231 (433.92MHz) TEST CONDITION : Normal TEST DATE : 2003. 2. 7 ∼ 2. 7 RESULTS AND NOTES The bandwidth of the emission shall be no wider than 0.25% of the center frequency for devices operating above 70MHz and below 900MHz. The bandwidth is determined at the points 20dB down from the modulated carrier. @433.92MHz 433.92 MHz x 0.0025 =1084.8 KHz 1084.8 KHz / 2 =542.4 KHz The bandwidth at 20dB down is 32.42kHz which is within the allowable limit of 542.4KHz at 433.92 MHz ========== SUMMARY========== ALL data is within limits TEST REPORT Date : 2003-02-13 No. : BRF-0302002 Page 6 of 9 UNINTENTIONAL RADIATOR (3) Measurement of Radiated Interference Not Applicable CONDUCTED LIMITS (4) Measurement of Line-Conducted Voltage onto AC Power Line Not Applicable (5) Transmission Requirement according to § 15.231(a)(1),(2),(3),(4) and Calculation of Duty cycle correction factor (Average factor) Results: Satisfactory The results of the transmission duration and duty cycle are shown in next page. The transmission duration was 59.92 ms and the duty cycle correction factor was computed to be –4.4 dB. The intentional radiator is restricted to the transmission of a control signal such as those used with alarm systems, door openers, remote switches, etc. Continuous transmissions, such as voice or video, and data transmissions are not permitted. According to §15.231(a)(1), A manually operated transmitter shall employ a switch that will automatically deactivate the transmitter within not more than 5 seconds of being released. (2), A transmitter activated automatically shall cease transmission within 5 seconds after activation. (3),Periodic transmissions at regular predetermined intervals are not permitted. However, polling or supervision transmissions to determine system integrity of transmitters used in security or safety applications are allowed if the periodic rate of transmission of not more than one second duratio…
Text truncated - open the document above for the full version.
Test Photo
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.425 MHz - 434.415 MHz | - |

Wireless Security System - Main Unit
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
Wireless Security System - Main Unit
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Fire Sensor
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Door/ Window Sensor
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Remote Controller
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter