Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
3M Resident Monitoring 7170 W. Donges Bay Road Toll Free: 800-606-0661 Mequon, WI 35092 Office: 414-358-8200 Fax: 414-358-8100 www.3m.com/residentmonitoring Copyright 2012 all rights reserved This document contains information that is proprietary to Attenti Ltd. No part of this publication may be reproduced in any form whatsoever without prior written approval by Attenti. Pull Cord USER MANUAL 3M Resident Monitoring Pull Cord User Manual Page: 2 of 9 TABLE OF CONTENTS 1 Foreword............................................................................................................................................................ 3 1.1 Pull Cord with RFID Device - State machine Drawing: ........................................................................... 4 1.2 Pull Cord with RFID Device - Indications: ............................................................................................... 5 1.3 Pull Cord without RFID Device (emulating PC 830) - State machine Drawing: ...................................... 6 1.4 Pull Cord without RFID Device (emulating PC 830) - Indications: .......................................................... 7 1.5 Activating the Pull Cord: .......................................................................................................................... 8 1.6 Activating a Panic Alert: .......................................................................................................................... 8 1.7 Deactivating a Panic Alert: ...................................................................................................................... 8 1.8 Deactivating the Pull Cord: ...................................................................................................................... 8 1.9 Cleaning Instructions ............................................................................................................................... 8 2 FCC Notices ...................................................................................................................................................... 9 3M Resident Monitoring Pull Cord User Manual Page: 3 of 9 1 FOREWORD The Pull Cord is a small wall-mounted device, to be installed at bedside and in the bathroom of nursing homes and assisted living homes. Once pulled, the Pull Cord Device shall transmit panic messages once every 20 seconds until it is reset by a nurse using NTT device with RFID tag. The Pull cord shall include RFID reader circuit to support handshake with the Nurse Tag Transmitter (NTT). When the staff members present/taps the NTT on the pull cord, the Pull cord will detect the tag and will send NTT ID to the system. The first time that the PC-GHWHFWVWKH177LWVKDOOVHQGD³Staff assistance enters ́PHVVDJHWRWKHV\VWHP,IWKHVDPH177LV detected a second time, the PC-VKDOOVHQGD³Staff assistance left ́PHVVDJH to the system. In case the nurse did not tap the NTT on leave, the PC-ZLOOVHQG³$XWR-OHIW ́PHVVDJHDIWHUPLQThe PC-840 save up to 10 NTT ID, for each NTT the PC-VHQG³Staff assistance enters ́DQG³Staff assistance left ́PHVVDJHDQGKDYH sepDUDWHWLPHUIRU³DXWR-OHIW ́PHVVDJH Once pulled, the PC-840 shall close a Normally Open (N/O) output or open a Normally Closed (N/C) output that will used to turn on/off a corridor indication light. While the Pull Cord is ON, it shall transmit a status message, once every hour, to indicate that it is still functioning and to report its power supply state. A button, on the PC-840, shall be used for perform resident wellness check-in, while an DGGLWLRQDOVZLWFKZLOOEHXVHGIRUDQXUVHUHTXHVWIRUKHOS ³&RGH%OXH ́ :KHQ³&RGH%OXH ́LVDFWLYDWHGWKH3XOO FRUGVKDOOWXUQRQWKHFRUULGRUOLJKWDQGZKHQWKH³&RGH%OXH ́LVGHDFWLYDWHGGHYLFHVKDOOWXUQRIIFRUULGRUOLJKW The pull cord has three main variants: 1. With RFID reader- Pull Cord 840 2. Without RFID reader (emulating PC 830) 3. Without RFID with external power option (emulating PC 830) 3M Resident Monitoring Pull Cord User Manual Page: 4 of 9 1.1 Pull Cord with RFID Device - State machine Drawing: 3M Resident Monitoring Pull Cord User Manual Page: 5 of 9 1.2 Pull Cord with RFID Device - Indications: LED Indication External power Battery Alarm Nurse present Swipe Steady Green OK OK No « « Orange (flash every 2 sec.) Missing OK No « « Orange (flash every 10 sec.) 'RQ¶W&DUH Low No « « Steady Red OK OK Yes « « Red (flash every 10 sec.) Missing 'RQ¶W&DUH Yes « « Green (flash 3 times fast) 'RQ¶W&DUH 'RQ¶WCare No « Yes Red (flash 3 times fast) 'RQ¶W&DUH 'RQ¶W&DUH Yes « Yes Green (slow flashing) 'RQ¶W&DUH 'RQ¶W&DUH No Yes « Red (slow flashing) 'RQ¶W&DUH 'RQ¶W&DUH Yes Yes « x Steady Green = OK x Orange = Power Trouble x Red = Alarm x Fast flashing = Swipe confirmation x Slow flashing = Nurse present Activity Button and Nurse Presence LED Functionality 1) When switch pressed Once± Long Red LED blink (1 Second) 2) When switch pressed twice ± Logs Red LED blink (1 Second) The buzzer shall beep shortly one-time when RFID reader successful read NTT RFID tag and send ³1XUVH3UHVHQFH ́PHVVDJH. The buzzer shall beep shortly two time when read NTT RFID tag and send ³1XUVHOHIW ́PHVVDJH 3M Resident Monitoring Pull Cord User Manual Page: 6 of 9 1.3 Pull Cord without RFID Device (emulating PC 830) - State machine Drawing: 3M Resident Monitoring Pull Cord User Manual Page: 7 of 9 1.4 Pull Cord without RFID Device (emulating PC 830) - Indications: AC Power Battery Alarm Code Blue LED Indication OK OK No No LED Off Missing OK No No LED Off OK OK Yes No Steady Red Missing OK Yes No Flashing Red (every 20 sec.) OK OK No Yes Steady Red Missing OK No Yes Flashing Red (every 20 sec.) OK OK Yes Yes Steady Red Missing OK Yes Yes Flashing Red (every 20 sec.) OK Low No No On startup 5 Red Flashes of 100 mSec Missing Low No No On startup 5 Red Flashes of 100 mSec OK Low Yes No Alarm Start with 5 Red Flashed of 100 mSec and then Stea…
Text truncated - open the document above for the full version.
3M Resident Monitoring 2 Habarzel St., +972 3 767 1900 Office P.O. Box 13236 +972 3 767 1901 Fax Tel-Aviv 61131, Israel www.3m.com/residentmonitoring 19.04.2012 The PC-840 / PC-840-2 - Block Diagram
3M Resident Monitoring 2 Habarzel St., +972 3 767 1900 Office P.O. Box 13236 +972 3 767 1901 Fax Tel-Aviv 61131, Israel www.3m.com/residentmonitoring 19.04.2012 FCC Confidentiality Form Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Gentlemen, This letter is to comply with Section 0.457(d)(2)(i) and 0.459 pertaining to confidential material. HomeFree would like the following documents regarding this submission for FCC ID: QUX-PC-840-2 to be kept confidential. • Permanent Confidentiality: Schematics • Short-term Confidentiality (180 days): Installation Manual The above material contains trade secrets or technical data, which would customarily be guarded from competitors. We do not want this document to be accessible to the general public. Sincerely, Shai Avigdori Director, Quality Assurance
3M Resident Monitoring 2 Habarzel St., +972 3 767 1900 Office P.O. Box 13236 +972 3 767 1901 Fax Tel-Aviv 61131, Israel www.3m.com/residentmonitoring 19.04.2012 Letter for FCC’s Drug Compliance Statement EMCCert DR. RAŠEK Boelwiese 5 91320 Ebermannstadt Germany Tel.: +49-9194-9331 Fax: +49-9194-7964-84 E-mail: [email protected] URL: http://www.emcc.de We the undersigned, hereby certify that, in the case of individual applicant, he or she is not subject to a denial of federal benefits pursuant to section 5301 of the Anti- Drug Abuse Act of 1988, 21 USC 853a or in the case of non-individual applicant (e.g. corporation, partnership or other unincorporated association), no party to the applicant is subject to a denial of federal benefit pursuant to that action. Sincerely, Sincerely yours, Shai Avigdori Director, Quality Assurance
3M Resident Monitoring 2 Habarzel St., +972 3 767 1900 Office P.O. Box 13236 +972 3 767 1901 Fax Tel-Aviv 61131, Israel www.3m.com/residentmonitoring 12.08.12 External Pictures PC-840-2
3M Resident Monitoring 2 Habarzel St., +972 3 767 1900 Office P.O. Box 13236 +972 3 767 1901 Fax Tel-Aviv 61131, Israel www.3m.com/residentmonitoring 13.09.2012 PC-840-2 – Label
3M Resident Monitoring 2 Habarzel St., +972 3 767 1900 Office P.O. Box 13236 +972 3 767 1901 Fax Tel-Aviv 61131, Israel www.3m.com/residentmonitoring 19.04.2012 Label Location QUX-PC-840-2
3M Resident Monitoring 2 Habarzel St., +972 3 767 1900 Office P.O. Box 13236 +972 3 767 1901 Fax Tel-Aviv 61131, Israel www.3m.com/residentmonitoring 12.08.12 Internal Pictures PC-840-2
3M Resident Monitoring 2 Habarzel St., +972 3 767 1900 Office P.O. Box 13236 +972 3 767 1901 Fax Tel-Aviv 61131, Israel www.3m.com/residentmonitoring 12.08.2012 PC–840-2 Pull Cord Operational Description The Pull Cord Station is a small, wall-mounted device, installed at the bedside or in the lavatories of care centers. If a Resident needs assistance, the Pull Cord Station can be activated to alert care center staff members. The Pull Cord Station can be connected to a variety of triggers and alert devices. The device comprises a printed circuit board (PCB) that includes a RF transceiver module with an integral antenna, RFID reader with RFID antenna and a microcontroller that controls its operation. The PC-840-2 has one RF channel (318MHz or 433MHz) over which it communicates with its monitoring system. The PC-840-2 has RFID reader to read 13.56MHz RFID tags included in NTT. The unit is powered by an external power 12- 24 VDC and an internal 3.6V Lithium battery. When external power is off device continue work whit internal battery but in this case RDIF reader does not work. Once installed and activated the device transmit once every hour supervision signal, including data (e.g. battery ok) in order to indicate that the transmitter is functionally. The total duration of transmissions does not exceed more than one second per hour: 1 transmissions per Hour X 6 mSec (max.) = 0.006 seconds The PC – 840 transmit alarm message in case when the pull cord mechanism is pulled down or external push cord button is pressed. In this mode device transmit RF message once every approximately 18-22 seconds. This will go on until device will pull up by a nurse or Stuff.
Test Report E115120.04 3M Resident Monitoring Ltd. Page 1 of 63 DATE: 12 September 2012 I.T.L. (PRODUCT TESTING) LTD. FCC Radio Test Report for 3M Resident Monitoring Ltd. Equipment under test: Pull Cord Station PC-840-2 Written by: ____________________________ A. Ruta / D. Shidlowsky Documentation Approved by: ________________________________ A. Sharabi, Test Engineer Approved by: ____________________________ Raz, EMC Laboratory Manager This report must not be reproduced, except in full, without the written permission of I.T.L. (Product Testing) Ltd. This report relates only to items tested. Test Report E115120.04 3M Resident Monitoring Ltd. Page 2 of 63 Measurement/Technical Report for 3M Resident Monitoring Ltd. Pull Cord Station PC-840-2 FCC ID: QUX-PC-840-2 IC: 4306B-PC8402 This report concerns: Original Grant: x Class I change: Class II change: Equipment type: Part 15 Security/Remote Control Transceiver 47CFR15 Sections 15.225l; 15.231 (a-d) Measurement procedure used is ANSI C63.4-2003. Application for Certification: prepared by: Shai Avigdori 3M Resident Monitoring Ltd. 2 Habarzel St. Tel-Aviv, 61131 Israel Tel: +972-3- 767-1700 Fax: +972-3- 767-1701 e-mail: [email protected] Test Report E115120.04 3M Resident Monitoring Ltd. Page 3 of 63 TABLE OF CONTENTS 1. GENERAL INFORMATION ------------------------------------------------------------------------------- 5 1.1 Administrative Information ................................................................................. 5 1.2 List of Accreditations ......................................................................................... 6 1.3 Product Description ........................................................................................... 7 1.4 Test Methodology .............................................................................................. 7 1.5 Test Facility ....................................................................................................... 7 1.6 Measurement Uncertainty ................................................................................. 7 2. SYSTEM TEST CONFIGURATION --------------------------------------------------------------------- 8 2.1 Justification ........................................................................................................ 8 2.2 Special Accessories .......................................................................................... 8 2.3 Equipment Modifications ................................................................................... 8 2.4 Configuration of Tested System ........................................................................ 8 3. CONDUCTED AND RADIATED MEASUREMENT TEST SET-UP PHOTOS ---------------- 9 4. CONDUCTED EMISSION FROM AC MAINS, 13.56 MHZ TRANSMITTER OPERATING ------------------------------------------------------------------------------------------------- 11 4.1 Test Specification ............................................................................................ 11 4.2 Test Procedure ................................................................................................ 11 4.3 Test Results..................................................................................................... 11 4.4 Conducted Emission From AC Mains, 13.56 MHz Transmitter, Test Equipment Used .............................................................................................. 16 5. FIELD STRENGTH OF FUNDAMENTAL, 13.56 MHZ TRANSMITTER ---------------------- 17 5.1 Test Specification ............................................................................................ 17 5.2 Test Procedure ................................................................................................ 17 5.3 Test Results..................................................................................................... 17 5.4 Field Strength of Fundamental 13.56 MHz Transmitter, Test Equipment Used ................................................................................................................ 20 6. SPURIOUS RADIATED EMISSION, 9 KHZ – 30 MHZ, 13.56 MHZ --------------------------- 21 6.1 Test Specification ............................................................................................ 21 6.2 Test Procedure ................................................................................................ 21 6.3 Test Results..................................................................................................... 21 6.4 Spurious radiated Emission 9 kHz – 30 MHz, 13.56 MHz Transmitter, Test Equipment Used .............................................................................................. 22 7. SPURIOUS RADIATED EMISSION 30 – 1000 MHZ, 13.56 MHZ TRANSMITTER -------- 23 7.1 Test Specification ............................................................................................ 23 7.2 Test Procedure ................................................................................................ 23 7.3 Test Results..................................................................................................... 23 7.4 Spurious Radiated Emission 30 – 1000 MHz, 13.56 MHz Transmitter, Test Equipment Used .............................................................................................. 25 7.5 Field Strength Calculation ............................................................................... 25 8. FREQUENCY TOLERANCE 13.56 MHZ TRANSMITTER --------------------------------------- 26 8.1 Test Specification ............................................................................................ 26 8.2 Test Procedure ................................................................................................ 26 8.3 Test Results..................................................................................................... 26 8.4 Frequency Tolerance 13.56 MHz Transmitter, Test Equipment Used ............ 27 9. CONDUCTED EMISSI…
Text truncated - open the document above for the full version.
3M Resident Monitoring 2 Habarzel St., +972 3 767 1900 Office P.O. Box 13236 +972 3 767 1901 Fax Tel-Aviv 61131, Israel www.3m.com/residentmonitoring 19.04.2012 PC-840 Test Setup Photographs
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 13.56 MHz - 13.56 MHz | - |

Pull Cord Station
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
Universal Receiver
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
Nurse Tracking Tag
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Nurse Tracking Tag
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Wrist Watch Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter