Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
5.8GHz ASIC Analog Multi Hand CID MODEL : Revision : 01 Revision Date : 2007/JUN/01 Written By S.K. Kim First Issued 2007/JUN/01 Page : 1/24 ` USER’S MANUAL MODEL : 5.8GHz CORDLESS PHONE 35290, 35291, 35292, 35293, MB5290, MB5291, MB5292, MB5293 5.8GHz ASIC Analog Multi Hand CID MODEL : Revision : 01 Revision Date : 2007/JUN/01 Written By S.K. Kim First Issued 2007/JUN/01 Page : 2/24 TABLE OF CONTENTS 1. FCC INFORMATION--------------------------------------------------------------------------------------- 3 2. FUNCTIONAL SUMMARY ------------------------------------------------------------------------------10 2.1. Scope........................................................................................................................10 2.2. Features.....................................................................................................................10 3.USER INTERFACE DESCRIPTION-------------------------------------------------------------------14 3.1. Initial factory settings...................................................................................................14 3.2. Default settings............................................................................................................14 3.3. Ringing and Tones........................................................................................................14 3.4. Display.........................................................................................................................16 3.5. Operational description.................................................................................................18 5.8GHz ASIC Analog Multi Hand CID MODEL : Revision : 01 Revision Date : 2007/JUN/01 Written By S.K. Kim First Issued 2007/JUN/01 Page : 3/24 1. FCC INFORMATION READ THIS BEFORE INSTALLATION Your telephone conforms to federal regulations, and you can connect it to most telephone lines, However, each device you connect to the phone line draws power from the phone line. We refer to this power draw as the device’s ringer equivalence number, or REN. The REN is shown on the label of your phone If you are using more than one phone or other devices on the line, add up all the RENS. If the total is more than five, your phone might not ring in rural areas, a total REN of three might impair ringer operation. FCC STATEMENT This telephone complies with part 68 of FCC Rules. You must, upon request, provide the FCC Registration Number and the REN to your phone company. These numbers are located on the label of your phone. Note: You must not connect your phone to any of the followings: • Coin-operated system • Patty-line systems • Most electronic key phone systems Your telephone operates on standard radio frequencies, as allocated by the FCC. Even though the access protection code prevents unauthorized use of your phone line, it is possible for other radio units operating on similar frequencies within a certain area to unintentionally intercept your conversations and/or cause interference. This lack of privacy can occur with any cordless phone. 1) This equipment complies with Part 68 of the FCC rules and the requirements adopted by the ACTA. On the bottom of this equipment is a label that contains, among other information, a product identifier in the format US:47GW400B35293-4. If requested, this number must be provided to the telephone company. 2) An applicable certification jacks Universal Service Order Codes (USOC) for the equipment is provided RJ11C in the packaging with each piece of approved terminal equipment. 3) A plug and jack used to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC Part 68 rules and requirements adopted by the ACTA. A compliant telephone cord and modular plug is provided with this product. It is designed to be connected to a compatible modular jack that is also compliant. See installation instructions for details. 5.8GHz ASIC Analog Multi Hand CID MODEL : Revision : 01 Revision Date : 2007/JUN/01 Written By S.K. Kim First Issued 2007/JUN/01 Page : 4/24 4) The REN is used to determine the number of devices that may be connected to a telephone line. Excessive RENs on a telephone line may result in the devices not ringing in response to an incoming call. In most but not all areas, the sum of RENs should not exceed five (5.0). To be certain of the number of devices that may be connected to a line, as determined by the total RENs, contact the local telephone company. For products approved after July 23, 2001, the REN for this product is part of the product identifier that has the format US:47GW400B35293-4. The digits represented by 0.0B are the REN without a decimal point. For earlier products, the REN is separately shown on the label. 5) If this equipment 35293-4 causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. But if advance notice isn't practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary. 6) The telephone company may make changes in its facilities, equipment, operations or procedures that could affect the operation of the equipment. If this happens the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service. 7) Should you experience trouble with this equipment, please contact Unical Enterprices Inc. (626)965-5588 for repair or warranty information. If the equipment is causing harm to the telephone network, the telephone company may request that you disconnect the equipment until the problem is resolved. 8) Please follow instructions for repairing if any (e.g. battery replacement section); otherwise do not alternate or repair any parts of device except specified. 9) Connection to party line service is subject to state tariffs. C…
Text truncated - open the document above for the full version.
INTERTEK TESTING SERVICES External Photos FCC ID: QVF0701 external photos - 1 of 2 INTERTEK TESTING SERVICES External Photos FCC ID: QVF0701 external photos - 2 of 2
f o r m a t O F F USE ONLY WITH CLASS 2 POWER SOURCE TEL LINE 9V DC 300mA I N F O R M A T I O N T E C H N O L O G Y E Q U I P M E N T C M C M x x x x x x x U S 9V DC 150mA GHzGHz V. MAIL cordless phone T h i s d e v i c e c o m p l i e s w i t h P a r t 1 5 o f t h e F C C R u l e s . O p e r a t i o n i s s u b j e c t t o t h e f o l l o w i n g t w o c o n d i t i o n s : ( 1 ) t h i s d e v i c e m a y n o t c a u s e h a r m f u l i n t e r f e r e n c e , a n d ( 2 ) t h i s d e v i c e m u s t a c c e p t a n y i n t e r f e r e n c e r e c e i v e d , i n c l u d i n g i n t e r f e r e n c e t h a t m a y c a u s e u n d e s i r e d o p e r a t i o n . P r i v a c y o f c o m m u n i c a t i o n s m a y n o t b e e n s u r e d w h e n u s i n g t h i s p h o n e . Complies with 47 CFR Part 68 requirements USOC JACK: RJ11C REN: 0.2B HAC FCC ID: QVF0701 REGIS TRATION NUMBER: US: 47GXXXXXXXXXXXXX MADE IN CHINA MODEL No: 35293-4 S/N 7070000000 FCC ID: QVF0701 CLASS 2 ONLY 4 8 . 8 m m 19.5 mm 3 2 . 1 m m 23.3 mm 31.0 mm 1 8 . 6 m m
INTERTEK TESTING SERVICES Internal photos FCC ID: QVF0701 internal photos - 1 of 3 Base Unit assembly Base Unit Main PCB comp side INTERTEK TESTING SERVICES Internal photos FCC ID: QVF0701 internal photos - 2 of 3 Base Unit Main PCB solder side Base Unit Oscillator PCB comp side INTERTEK TESTING SERVICES Internal photos FCC ID: QVF0701 internal photos - 3 of 3 Base Unit Oscillator PCB solder side
- The evaluation data of the report will be kept for 3 years from the date of issuance. - This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com I-Tel Corporation Application For Certification 5.8GHz/2.4GHz 40 Channel Analog Modulation Cordless Phone with Caller ID - Base Unit (FCC ID: QVF0701) 07142321 KL/ ac August 1, 2007 INTERTEK TESTING SERVICES FCC ID: QVF0701 i LIST OF EXHIBITS INTRODUCTION EXHIBIT 1: General Description EXHIBIT 2: System Test Configuration EXHIBIT 3: Emission Results EXHIBIT 4: Equipment Photographs EXHIBIT 5: Product Labelling EXHIBIT 6: Technical Specifications EXHIBIT 7: Instruction Manual EXHIBIT 8: Security Code Information EXHIBIT 9: Confidentiality Request INTERTEK TESTING SERVICES FCC ID: QVF0701 ii MEASUREMENT/TECHNICAL REPORT I-Tel Corporation - MODEL: 35293-4, 35290, 35291, 35292, MB5293, MB5290, MB5291, MB5292 FCC ID: QVF0701 This report concerns (check one:) Original Grant X Class II Change Equipment Type : DXT - Cordless Telephone Deferred grant requested per 47 CFR 0.457(d)(1)(ii)? Yes No X If yes, defer until : date Company Name agrees to notify the Commission by: date of the intended date of announcement of the product so that the grant can be issued on that date. Transition Rules Request per 15.37 ? Yes No X If no, assumed Part 15, Subpart C for intentional radiator - the new 47 CFR [05-04-07 Edition] Provision. Report prepared by: Lam Chun Cheong, Kenneth Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Phone : 852-2173-8474 Fax: 852-2741-1693 INTERTEK TESTING SERVICES FCC ID: QVF0701 iii Table of Contents 1.0 General Description................................................................................................. 2 1.1 Product Description ................................................................................................. 2 1.2 Related Submittal(s) Grants .................................................................................... 3 1.3 Test Methodology.................................................................................................... 3 1.4 Test Facility............................................................................................................. 3 2.0 System Test Configuration...................................................................................... 5 2.1 Justification ............................................................................................................. 5 2.2 EUT Exercising Software......................................................................................... 5 2.3 Support Equipment List and Description .................................................................. 6 2.4 Measurement Uncertainty ....................................................................................... 7 2.5 Equipment Modification ........................................................................................... 7 3.0 Emission Results..................................................................................................... 9 3.1 Field Strength Calculation...................................................................................... 10 3.2 Radiated Emission Configuration Photograph - Base Unit...................................... 11 3.3 Radiated Emission Data - Base Unit ...................................................................... 12 3.4 Radiated Emission on the Bandedge..................................................................... 15 3.5 Line Conducted Configuration Photograph - Base Unit .......................................... 16 3.6 Line Conducted Emission Data - Base Unit ........................................................... 17 4.0 Equipment Photographs........................................................................................ 20 5.0 Product Labelling................................................................................................... 22 6.0 Technical Specifications........................................................................................ 24 7.0 Instruction Manaual............................................................................................... 26 8.0 Security Code Information.................................................................................... 28 9.0 Confidentiality Request......................................................................................... 30 INTERTEK TESTING SERVICES FCC ID: QVF0701 iv List of attached file Exhibit type File Description filename Cover Letter Confidentiality Request request.pdf Test Report Test Report report.pdf Operation Description Technical Description descri.pdf Test Setup Photo Radiated & Conducted Emission config photos.doc Test Report Emission Plot emission.pdf Test Report Conducted Emission Test Result conduct.pdf External Photo External Photo external photos.doc Internal Photo Internal Photo internal pho…
Text truncated - open the document above for the full version.
INTERTEK TESTING SERVICES Radiated Emission on the Bandedge Plots FCC ID: QVF0701 emission - 1 of 1 Plot B1A
Report No.: 07142321 Talk Mode Ctrl No.: N/A PAGE 1 Report No.:07142321 Scan Settings (1 Range) |--------- Frequencies -----------||----------- Receiver Settings ------------| Start Stop Step IF BW Detector M-Time Atten Preamp OpRge 150k 30M 5k 10k PK+AV 10ms AUTO LN OFF 60dB Final Measurement: x QP / + AV Meas Time: 1 s Subranges: 16 Acc Margin: 20dB Transducer No. Start Stop Name 2 1 9k 30M EW0700 12 9k 30M EW0090 0 10 20 30 40 50 60 70 80 90 dBuV 100 0.15 MHz 30 110 F15Q F15A Report No.: 07142321 Talk Mode Ctrl No.: N/A Report No.:07142321 Scan Settings (1 Range) |--------- Frequencies -----------||----------- Receiver Settings ------------| Start Stop Step IF BW Detector M-Time Atten Preamp OpRge 150k 30M 5k 10k PK+AV 10ms AUTO LN OFF 60dB Final Measurement Results: no Results
INTERTEK TESTING SERVICES The Worst Case Configuration Photographs FCC ID: QVF0701 config photos (radiated emission – base unit) - 1 of 1 Radiated Emission – Base Unit Front View Rear View INTERTEK TESTING SERVICES The Worst Case Configuration Photographs FCC ID: QVF0701 config photos (conducted emission) - 1 of 2 Conducted Emission Front View Right Side View INTERTEK TESTING SERVICES The Worst Case Configuration Photographs FCC ID: QVF0701 config photos (conducted emission) - 2 of 2 Conducted Emission Left Side View
Flat D, 5/F., Garment Centre, · Kowloon, · Hong Kong
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 5.73 GHz - 5.73 GHz | - |

5.8GHz/2.4GHz Analog Cordless Phone w/CID-Handset
Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
5.8 GHz FHSS Cordless Phone
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
900MHz / 5.8GHz CORDLESS PHONE HANDSET
Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
BASE STATION
Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
2.4GHz/5.8GHz 40 Channel Analog Cordless Phone
Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified