FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Nike, Inc./
  3. QYUHRM2400

QYUHRM2400SMA011

Nike, Inc.
SMA011 - FCC ID QYUHRM2400 - Nike, Inc.
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Jul 29, 2003
Application Purpose
Original Equipment
Date of Application
Jul 29, 2003
Equipment Note
SMA011
Frequency Range
916.50000000 - 916.50000000
Company
Nike, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗
↗

Cover Letter(s)

↗
↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

RF Exposure Info

↗

Test Report

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Exhibit K: User Manual 1 FCC ID: QYUHRM2400 1 INDEX English . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 21 Français . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 241 Español . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 261 Português . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 81 Italiano . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 101 Deutsch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 02 121 Nederlands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 141 Dansk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142 161 Svenska . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 62 181 Service Centers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182 2 Information is PowerBy measuring intensity ( heart rate) and duration ( time) you can avoid over training,help prevent injury, and maximize yourchances of achieving your goals.triax c10 features • ECG accurate heart rate data• Digital Transmission• 100 lap memory• Programmable HR training zone• View button for quick access to key info• 5 segment interval timer • Data: timing information, time in zone, average heart rate for each lap / run,interval information. • Time / Day / Date / Alarms HR transmitterThe Heart-Rate transmitter readsheart-rate information when worn directly against the skin and within a few meters of the watch. The HR transmitter is ergonomicallydesigned to fit comfortably during alltypes of exercise. ATTENTION: Anyone beginning an exercise regimen for the first time(especially users of pacemakers or other implanted devices) should consulta physician or health professional before using the heart-rate transmitter. 3 ContentsQuick Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 TIME modeSet Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Set Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 RUN modeUsing the Chronograph . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Setting Heart Rate Zone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Customizing Primary Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Setting “My View” Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 INTERVAL modeSetting Training Intervals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 DATA modeReview Saved Runs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Heart Rate Intensity Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Linking the HR Transmitter to the Watch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 FCC Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 CE Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Service Centers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 This document with updates is available online at www.nike.com /timing Printed on Wood Free Paper 4 Quick Start Follow steps through to position the heart-rate transmitter and go for a run. 3 1 2 4 Push tab up through slotin HR transmitter. Press down tab until flush. Attach other side of HR transmitteraround chest. Position on rib cagejust below the breast plate. The transmitter should be worn directly against skin and snug enough to stay in placeduring workout. Generously wet both grooved areas on the back of the HR transmitter to ensure a strong connection between your pulseand the transmitter. 5 Scroll to …

Text truncated - open the document above for the full version.

Users Manual

Exhibit K: User Manual 2 FCC ID: QYUHRM2400 1 INDEX English . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 23 Français . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 445 Español . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 667 Português . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 89 Italiano . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 111 Deutsch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 12 133 Nederlands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 155 Dansk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156 177 Svenska . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 78 201 Service Centers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202 2 Information is PowerBy measuring intensity ( heart rate / pace) and duration ( time) you can avoid over training,help prevent injury, and maximize yourchances of achieving your goals.triax cv10 features • Accurate heart-rate and pace data• Digital transmission• 100 lap memory• Programmable training zones• View button for quick access to key info• Automatic lap measurement• Data: timing information, time in zone, average pace and average heart rate for each lap / run. • Time / Day / Date / Alarms HR transmitterThe Heart-Rate transmitter reads heart-rateinformation when worn directly against the skin and within a few meters of the watch. The HR transmitter is ergonomically designedto fit comfortably during all types of exercise. SDM podThe SDM (Speed Distance Monitor) podmeasures foot acceleration/deceleration 100 times per second. When properly calibrated, the pod accurately calculatesspeed and distance even if stride length and running pace changes. ATTENTION: Anyone beginning an exercise regimen for the first time (especially users of pacemakers or other implanted devices)should consult a physician or health professional before using the Triax cv10. 3 ContentsQuick Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 TIME modeSet Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Set Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 RUN modeCalibrate the SDM Pod . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Using the Chronograph . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Setting Training Zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Setting Auto-Lap Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Setting “My View” Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 DATA modeReview Saved Runs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Heart Rate Intensity Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Running Pace Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Linking the Digital Components to the Watch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 FCC Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 CE Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Service Centers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 This document with updates is available online at www.nike.com /timing Printed on Wood Free Paper 4 Quick Start Follow steps through to position the HR transmitter and SDM pod and go for a run. 3 1 2 4 3 1 2 4 Push tab up throughslot in HR transmitter. Pr…

Text truncated - open the document above for the full version.

Cover Letter(s)

Exhibit A: Cover Letter From Agent FCC ID: QYUHRM2400 NORTHWEST EMC, INC. 22975 NW Evergreen Parkway, Suite 400 Hillsboro, OR 97124 July 22, 2003 Dear Application Examiner: On behalf of Nike, Northwest EMC Inc is submitting this application for the certification of Nike’s SMA011 transmitter, FCC ID: QYUHRM2400. It operates 916.5 MHz (center frequency) utilizing On-Off-Keying (OOK) modulation. The transmitter is contained in a chest strap and is intended to be used with a watch receiver (that has FCC authorization) to display real time heart rate data on the watch during exercise. When the strap is worn on the chest and powered on, it transmits the users current heart rate in beats per minute to the watch, about 1 meter away. The transmitter contains an integral antenna that is etched onto the circuit board. This satisfies the requirements of 47 CFR 15.203. The Northwest EMC technical report is supplied in support of this antenna. The technical reports and exhibits demonstrate compliance with FCC rules 47 CFR 15.249. To facilitate the review process, an index of exhibits has been provided. Your efforts in reviewing this application are greatly appreciated. Best regards, Greg Kiemel, Director of Engineering Northwest EMC, Inc.

Cover Letter(s)

Northwest EMC TCB Compliance Opinion Revision 1/3/03 NIKE0006 Information about the Applicant Company Name Nike Address 1 Bowerman Drive, Mia Hamm Building, Floor 2 City, State, Zip Beaverton, OR, 97005 Requested By Charlie Case Job Number SMA011 Digital Heart Rate Monitor Model Nike FCC ID QYUHRM2400 Agent Northwest EMC, Inc. Approval Type Certification Equipment Type Low power transmitter Rule Part 15.249 Overview This application is for the Nike SMA011 transmitter, FCC ID: QYUHRM2400. It operates 916.5 MHz (center frequency) utilizing On-Off-Keying (OOK) modulation. The transmitter is contained in a chest strap and is intended to be used with a watch receiver (that has FCC authorization) to display real time heart rate data on the watch during exercise. When the strap is worn on the chest and powered on, it transmits the users current heart rate in beats per minute to the watch, about 1 meter away. The transmitter contains an integral antenna that is etched onto the circuit board. This satisfies the requirements of 47 CFR 15.203. The Northwest EMC technical report is supplied in support of this antenna. Recommendation All items have been resolved and completed to my satisfaction; therefore I recommend this application for approval. July 29, 2003 _______________________________ ________________ Dean Ghizzone, President Date Findings and Resolution Item Resolution Northwest EMC TCB Compliance Opinion Revision 1/3/03 NIKE0006 Opinion Specification Requirements Description 2.1093 RF Exposure Opinion: The Equipment meets the intent specified by the requirements listed above. Discussion: The Applicant has submitted test results in the form of a test report. Reference: Exhibit H Specification Requirements Description 15.249 Field Strength of the Fundamental Opinion: The Equipment meets the intent specified by the requirements listed above. Discussion: The Applicant has submitted test results in the form of a test report. Reference: Exhibit M Specification Requirements Description 15.249 Spurious Emissions, Radiated Emissions Opinion: The Equipment meets the intent specified by the requirements listed above. Discussion: The Applicant has submitted test results in the form of a test report. Reference: Exhibit M

Cover Letter(s)

FCC ID: QYUHRM2400 Exhibit A Cover Letter From Agent Exhibit B FCC ID Label & Location Exhibit C External Photos Exhibit D Internal Photos Exhibit E Schematics Exhibit F Frequency Block Diagram Exhibit G Antenna Description Exhibit H RF Exposure Exhibit I Agent Authorization Letter Exhibit J Operational Description Exhibit K User Manual Exhibit L Request for Confidentiality Letter Exhibit M Technical Report Exhibit N Test Setup Photos

Cover Letter(s)

Exhibit L: Request for Confidentiality Letter FCC ID: QYUHRM2400

Cover Letter(s)

Exhibit I: Agent Authorization Letter FCC ID: QYUHRM2400

External Photos

Exhibit C: External Photos FCC ID: QYUHRM2400

ID Label/Location Info

Exhibit B: FCC ID Label & Location on Radio FCC ID: QYUHRM2400 FCC ID: QYUHRM2400 IC: 4571A-SMA011 O P E N 000 SMA011 made in china FCC ID Label and Location SMA011 Heart Rate Monitor

Internal Photos

Exhibit D: Internal Photos FCC ID: QYUHRM2400 Digital Heart Rate Monitor In ter nal Photos (Cir cuit Board) SMA011 Heart Rate Monitor Bottom View of Prin ted Cir cuit Board Top View of Prin ted Cir cuit Board

Operational Description

Exhibit G: Antenna Description FCC ID: QYUHRM2400 Nike Digital Heart Rate Monitor Antenna Info Antenna Description: "The only antenna that can be used with the device is an approximately one quarter wave monopole etched on the internal circuit board, thus satisfying the requirements of 15.203. This cannot be added to or modified without destroying the product. Antenna Images:

RF Exposure Info

Exhibit H: RF Exposure FCC ID: QYUHRM2400 RF Exposure Nike Digital Heart Rate Monitor Date: July 18,2003 Summary of RF Exposure This device is operated in a manner that ensures the public is not exposed to radio frequency energy levels in excess of the Commission's guidelines. This device is categorically excluded from routine environmental evaluation. This device operates in a body-worn configuration under 47 CFR 15.249, and is therefore excluded from SAR evaluation based upon 2.1093(c) and its low EIRP (< 1mW).

Test Setup Photos

Exhibit N: Test Setup Photos FCC ID: QYUHRM2400

Contact Information

Applicant

Catherine Morrison(Engineering Program Manager)
[email protected]503-532-7974Fax: 503-532-4646

Technical Contact

Northwest EMC, Inc.Greg Kiemel
[email protected]503-844-4066

22975 NW Evergreen Parkway · Hillsboro, Oregon · United States

Non-Technical Contact

Northwest EMC, Inc.Vicki Albertson
[email protected]503-844-4066

Test Firm

Northwest EMC, Inc.Greg Kiemel
[email protected]503-844-4066Fax: 503-844-3826

Technical Specifications

#Rule PartsFrequency RangePower Output
115C916.5 MHz - 916.5 MHz-
Confidentiality
Long Term

Other Applications from Nike, Inc.

Wireless Communication Device - FCC ID QYU-LE04 - Nike, Inc.
QYU-LE04

Wireless Communication Device

Nov 08, 2022

Equipment Class

DTS - Digital Transmission System
Nike + Sports Kit - FCC ID QYUESP11 - Nike, Inc.
QYUESP11

Nike + Sports Kit

Jun 10, 2012

Equipment Class

DTS - Digital Transmission System
Nike + Sports Kit - FCC ID QYUESP12 - Nike, Inc.
QYUESP12

Nike + Sports Kit

Jun 10, 2012

Equipment Class

DTS - Digital Transmission System
Nike+ FuelBand - FCC ID QYUM411 - Nike, Inc.
QYUM411

Nike+ FuelBand

Feb 01, 2012

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Nike + Sportband - FCC ID QYUFL500 - Nike, Inc.
QYUFL500

Nike + Sportband

Feb 19, 2008

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter