R2SEFCTelemetry Equipment

HOSEOTELNET CO., LTD.
Telemetry Equipment - FCC ID R2SEFC - HOSEOTELNET CO., LTD.
Click to zoom

Application Details

Equipment Class
PCB - PCS Licensed Transmitter
Date of Grant
May 29, 2005
Application Purpose
Original Equipment
Date of Application
May 29, 2005
Equipment Note
Telemetry Equipment
Frequency Range
896.00000000 - 901.00000000
Company
HOSEOTELNET CO., LTD.
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

INSTALLATION GUIDE Welcome It is very important that you familiarize your- self with these installation instructions be- fore attempting to install your device. Basic knowledge of automotive electrical systems and functional components are needed in order to successfully install your FleetHawk device. If you are not a qualified automotive electrical technician or do not feel comfortable performing this installation, we strongly recommend that you work with a trusted automotive professional in your area to install FleetHawk according to your needs. The instructions provided are only a guide and do not necessarily apply to your particular vehicle. Component List n Installation Guide n FleetHawk Pro device n GPS/RF combination antenna, OR l GPS antenna, AND l Radio (RF) antenna n Installation Kit: l (1) In Line Fuse Holder l (2) 3 amp Fuses l (4) Butt Connectors l (2) Female Quick Disconnects l (1) Blade Style Connectors l (2) Mini Fuse Taps l (2) ATO Blade Type Fuse Taps l (4) Nylon Cable Ties n Extension Power cable (if purchased) n One of the following (if purchased): l Power cable (from device to accessory or cigarette lighter power outlet in ve- hicle) l Power cable with 16 loose wires for connectivity to systems for control and monitoring (advanced installation). l Power cable with 16 loose wires and two DB9 (serial) connectors for control, monitoring and connectivity to other intelligent hardware (advanced installa- tion). Cautions Only persons experienced with automotive electrical installations should attempt to hard- wire power to the FleetHawk device. Improper installation of electrical components and any resulting damage may impact your vehicle war- ranty. SkyTel will not be responsible or liable for any damage, injury or other loss suffered as a result of installations covered by these instructions. n Using pull ties, fastener screws, or Velcro, install or store the FleetHawk device inside the vehicle passenger cab or trunk. Do not install or store the device inside the en- gine compartment. n Exposure to excessive moisture or extreme heat can damage the FleetHawk device. The optimum operating temperature range for the device is -10º to 160º F. n All excess wiring should be neatly coiled and stored so that it is not crimped or rub- bing against other parts of the vehicle or interfering with use of the vehicle. n Any unused wires should be properly taped or capped so that they do not come into contact with one another or with other ve- hicular electrical sources. Power Sources for the FleetHawk Device 1 Constant Power: Locate a suitable 12- or 24-volt constant power source on the vehicle’s fuse block. Acceptable sources for power are: The vehicle’s battery; the fuse block; or wiring under the dash of the vehicle l The installation hardware kit shipped with your device includes an in line fuse holder that must be used to feed power to the device. A 3-amp fuse is also in- cluded but do not install the fuse until everything else has been installed, the cable is connected to the device, and you are ready to use the device. Installing the fuse should be your last step in completing the installation. l If you choose to get power from the fuse block on your vehicle, you can use a fuse tap and a female quick discon- nect. The fuse tap must be installed on the hot side of the fuse. To find the hot side of the fuse, remove the existing fuse from the fuse block and use a test light to probe the fuse socket. The side that lights the test probe is the hot side of the fuse where you should insert the fuse tap. l If you choose to get power directly from the battery or another wire on the ve- hicle be sure to use a suitable connector or splice method (such as soldering) to ensure a permanent connection. The device will not work without power. 2 Ground: Locate a suitable area to ground the device that is free from dirt and grease. Fasten the black wire from the cable to the ground source. Be sure the ground wire is securely fastened to the ground source. 3 Key On: Locate a “key on” power source using a test light. Connect the white wire marked with the number 1 (one) to the ‘key on’ power source. In most vehicles, there will be a number of sources for Constant Power, Ground, and Key On located under the dash. It is up to the installer to choose the best sources for their particular vehicle. It is impossible to cover wiring scenarios for all makes and models of vehicles in this installa- tion guide. If you have questions please contact a trusted automotive electrical professional to assist in the installation. Mounting the Antenna Depending on the type of antenna provided, locate a suitable place on your vehicle for the antenna to be installed. For optimal performance, both antennas should be mounted on the outside of the vehicle, on the windshield, roof, hood, or trunk. While you can mount the antennas elsewhere, performance may suffer as a result. n For the GPS/RF combination antenna, see the instruction sheet provided by the an- tenna manufacturer. n The GPS antenna will need an unobstructed sky view. n The RF antenna can be mounted in the inte- rior of the vehicle, if necessary. Make sure there is sufficient cabling to reach from the point of the antenna mount back to the where you have installed the FleetHawk device. Conceal any excess cable under the car- pet, trim, or dash where it will not be exposed to wear. Be careful not to crimp or kink the cable as this may damage the antenna or reduce its effectiveness. Component List, continued...Power Sources, continued... Customer Support email: [email protected] phone: 888-759-6818 8002028 1/05 © 2005 SkyTel Corp. SkyTel and FleetHawk are registered trademarks or service marks of SkyTel Corp. ���������� ������������������������������ ������������������������������������������ ���������������� ����������������� ��������������������������� ������������������������������ ��������������������� ������������������� ��������������������� �������…

Text truncated - open the document above for the full version.

Cover Letter(s)

Mike Kuo From: Y.G. Gwon [[email protected]] Sent: Thursday, May 26, 2005 5:55 PM To: Mike Kuo Subject: Fw: Hoseo Telnet Co., Ltd., FCC ID: R2SEFC, Assessment NO.: AN05T4730, Notice#1 6/1/2005 Hi Mike : How are you doing? Could you please confirm me current status for the subject project at your earliest convenience. Best regards, Y. G. Gwon ONETECH Corp. RF/EMC Team TEL: +82-31-765-8289 FAX: +82-31-766-2904 email: [email protected] ----- Original Message ----- From: Y.G. Gwon To: Mike Kuo Sent: Monday, May 23, 2005 5:05 PM Subject: Re: Hoseo Telnet Co., Ltd., FCC ID: R2SEFC, Assessment NO.: AN05T4730, Notice#1 Hi Mike : Did you have a nice weekend? I'd like to answer your kind comments as following. Could you please review those at your earliest convenience. Question #1: Please provide emission designator and necessary bandwidth information. For your information, necessary bandwidth can be justified by using 99% bandwidth measurement. [YK] The 99% Bandwidth is 7.25kHz, so I revised emission designator 7K25F1D in our test report. Enclose please find attached file. Question #2: User manual does not provide information to address RF exposure compliance. RF exposure statement must be included a required separation distance of 20 cm from the antenna to the body of user. Please provide revised user manual. [YK] Enclosed please find a file for revised user manual. Question #3: The radiated spurious emission limit is not correct for 43 + 10log(p). The correct limit should be -13dBm. Please make necessary correction on the test report. [YK] Thanks a lot. Enclosed pleas find a revised test report. Question #4: The reference standard called out in the test report for ANSI C63.4 should be ANSI C63.4: 2003. Please make necessary correction. [YK] Thanks a lot. Enclosed pleas find a revised test report. By the way, when was the effective date for ANSI C63.4/2003? Best regards, Y. G. Gwon ONETECH Corp. RF/EMC Team TEL: +82-31-765-8289 FAX: +82-31-766-2904 email: [email protected] ----- Original Message ----- From: "Mike Kuo" <[email protected]> To: <[email protected]> Sent: Wednesday, May 11, 2005 11:55 PM Subject: FW: Hoseo Telnet Co., Ltd., FCC ID: R2SEFC, Assessment NO.: AN05T4730, Notice#1 > > > > Best Regards > > Mike Kuo > Compliance Certification Services > 561F Monterey Road > Morgan Hill CA 95037 > Tel: (408)463-0885 x: 105 > Fax: (408)463-0888 > http://www.ccsemc.com > > > -----Original Message----- > From: Compliance Certification Services [mailto:[email protected]] > Sent: Wednesday, May 11, 2005 7:51 AM > To: Mike Kuo > Subject: Hoseo Telnet Co., Ltd., FCC ID: R2SEFC, Assessment NO.: > AN05T4730, Notice#1 > > Question #1: Please provide emission designator and necessary bandwidth > information. For your information, necessary bandwidth can be justified > by using 99% bandwidth measurement. > > Question #2: User manual does not provide information to address RF > exposure compliance. RF exposure statement must be included a required > separation distance of 20 cm from the antenna to the body of user. > Please provide revised user manual. > > Question #3: The radiated spurious emission limit is not correct for 43 > + 10log(p). The correct limit should be -13dBm. Please make necessary > correction on the test report. > > Question #4: The reference standard called out in the test report for > ANSI C63.4 should be ANSI C63.4: 2003. Please make necessary > correction. > > Best Regards > > Mike Kuo > > > > The items indicated above must be submitted before processing can > continue on the above referenced application. Failure to provide the > requested information within 30 days of the original e-mail date may > result in application dismissal and forfeiture of the filing fee. Also, > please note that partial responses increase processing time and should > not be submitted. Any questions about the content of this correspondence > should be directed to the e-mail address listed below the name of the > sender. 6/1/2005

Cover Letter(s)

ONETECH Corp. http://www.onetech.co.kr 505 SK APT Factory, 223-28 Sangdaewon 1-Dong, Jungwon-Gu, Seongnam-City, Kyunggi-Do 462-121, Korea [ Tel ] 82-31-746-8500, [ Fax ] 82-31-746-8700 ONETECH March 31, 2005 FCC Laboratory 7435 Oakland Mills Road Columbia, MD 21046 Attention: Application Examiner Reviewing Engineer Re: Request for confidentiality per Section 0.459 of FCC Rules Applicant: Hoseo Telnet Co., Ltd. FCC ID: R2SEFC To whom it may concern, Request is hereby submitted, on behalf of my client, Hoseo Telnet Co., Ltd., to withhold from public review certain portions of the application for equipment certification for the referenced FCC identifier. In particular, the following sections of the application and report are requested to be kept confidential: Schematics Block Diagram Operational Description Tune-Up Procedure Rationale for request for confidentiality: Hoseo Telnet Co., Ltd. has invested considerable time and materials in research and development to produce the referenced product. Disclosure of the confidential portions of this application to competitors would give them competitive advantage in developing similar products. If you have questions or need further information, please contact the undersigned. Sincerely, Y.K. Kwon / Director Onetech Corp. Email: [email protected]

External Photos

FCC ID. : R2SEFC File No. : E053R-083 It should not reproduced except in full, written approval of ONETECH. FCC-003 (Rev.0) HEAD OFFICE : #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea (TEL: +82-31-746-8500, FAX: +82-31-746-8700) EMC Testing Dept : 426-1 Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904) ONETECH Testing & Evaluation Lab. External Photos of Eagle 2 Model FCC ID. : R2SEFC File No. : E053R-083 It should not reproduced except in full, written approval of ONETECH. FCC-003 (Rev.0) HEAD OFFICE : #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea (TEL: +82-31-746-8500, FAX: +82-31-746-8700) EMC Testing Dept : 426-1 Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904) ONETECH Testing & Evaluation Lab. FCC ID. : R2SEFC File No. : E053R-083 It should not reproduced except in full, written approval of ONETECH. FCC-003 (Rev.0) HEAD OFFICE : #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea (TEL: +82-31-746-8500, FAX: +82-31-746-8700) EMC Testing Dept : 426-1 Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904) ONETECH Testing & Evaluation Lab. FCC ID. : R2SEFC File No. : E053R-083 It should not reproduced except in full, written approval of ONETECH. FCC-003 (Rev.0) HEAD OFFICE : #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea (TEL: +82-31-746-8500, FAX: +82-31-746-8700) EMC Testing Dept : 426-1 Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904) ONETECH Testing & Evaluation Lab. External Photos of Eagle 2 Model FCC ID. : R2SEFC File No. : E053R-083 It should not reproduced except in full, written approval of ONETECH. FCC-003 (Rev.0) HEAD OFFICE : #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea (TEL: +82-31-746-8500, FAX: +82-31-746-8700) EMC Testing Dept : 426-1 Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904) ONETECH Testing & Evaluation Lab. FCC ID. : R2SEFC File No. : E053R-083 It should not reproduced except in full, written approval of ONETECH. FCC-003 (Rev.0) HEAD OFFICE : #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea (TEL: +82-31-746-8500, FAX: +82-31-746-8700) EMC Testing Dept : 426-1 Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904) ONETECH Testing & Evaluation Lab.

ID Label/Location Info

FCC ID.: R2SEFC File No.: E053R-083 It should not reproduced except in full, written approval of ONETECH. FCC-003 (Rev.0) HEAD OFFICE : #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea (TEL: +82-31-746-8500, FAX: +82-31-746-8700) EMC Testing Dept : 426-1 Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904) ONETECH Testing & Evaluation Lab. IDENTIFICATION LABEL: PROPOSED FCC ID LABEL Due to the product size, only the FCC ID shall be permanently affixed to the rear side of the equipment and other information shall be placed in the instruction manual. FCC ID Location FCC ID : R2SEFC This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Internal Photos

FCC ID. : R2SEFC File No. : E053R-083 It should not reproduced except in full, written approval of ONETECH. FCC-003 (Rev.0) HEAD OFFICE : #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea (TEL: +82-31-746-8500, FAX: +82-31-746-8700) EMC Testing Dept : 426-1 Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904) ONETECH Testing & Evaluation Lab. Internal Photo of Eagle 2 Model FCC ID. : R2SEFC File No. : E053R-083 It should not reproduced except in full, written approval of ONETECH. FCC-003 (Rev.0) HEAD OFFICE : #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea (TEL: +82-31-746-8500, FAX: +82-31-746-8700) EMC Testing Dept : 426-1 Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904) ONETECH Testing & Evaluation Lab. FCC ID. : R2SEFC File No. : E053R-083 It should not reproduced except in full, written approval of ONETECH. FCC-003 (Rev.0) HEAD OFFICE : #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea (TEL: +82-31-746-8500, FAX: +82-31-746-8700) EMC Testing Dept : 426-1 Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904) ONETECH Testing & Evaluation Lab. FCC ID. : R2SEFC File No. : E053R-083 It should not reproduced except in full, written approval of ONETECH. FCC-003 (Rev.0) HEAD OFFICE : #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea (TEL: +82-31-746-8500, FAX: +82-31-746-8700) EMC Testing Dept : 426-1 Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904) ONETECH Testing & Evaluation Lab. FCC ID. : R2SEFC File No. : E053R-083 It should not reproduced except in full, written approval of ONETECH. FCC-003 (Rev.0) HEAD OFFICE : #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea (TEL: +82-31-746-8500, FAX: +82-31-746-8700) EMC Testing Dept : 426-1 Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904) ONETECH Testing & Evaluation Lab. FCC ID. : R2SEFC File No. : E053R-083 It should not reproduced except in full, written approval of ONETECH. FCC-003 (Rev.0) HEAD OFFICE : #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea (TEL: +82-31-746-8500, FAX: +82-31-746-8700) EMC Testing Dept : 426-1 Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904) ONETECH Testing & Evaluation Lab. FCC ID. : R2SEFC File No. : E053R-083 It should not reproduced except in full, written approval of ONETECH. FCC-003 (Rev.0) HEAD OFFICE : #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea (TEL: +82-31-746-8500, FAX: +82-31-746-8700) EMC Testing Dept : 426-1 Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904) ONETECH Testing & Evaluation Lab. FCC ID. : R2SEFC File No. : E053R-083 It should not reproduced except in full, written approval of ONETECH. FCC-003 (Rev.0) HEAD OFFICE : #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea (TEL: +82-31-746-8500, FAX: +82-31-746-8700) EMC Testing Dept : 426-1 Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904) ONETECH Testing & Evaluation Lab. FCC ID. : R2SEFC File No. : E053R-083 It should not reproduced except in full, written approval of ONETECH. FCC-003 (Rev.0) HEAD OFFICE : #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea (TEL: +82-31-746-8500, FAX: +82-31-746-8700) EMC Testing Dept : 426-1 Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904) ONETECH Testing & Evaluation Lab. FCC ID. : R2SEFC File No. : E053R-083 It should not reproduced except in full, written approval of ONETECH. FCC-003 (Rev.0) HEAD OFFICE : #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea (TEL: +82-31-746-8500, FAX: +82-31-746-8700) EMC Testing Dept : 426-1 Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904) ONETECH Testing & Evaluation Lab. FCC ID. : R2SEFC File No. : E053R-083 It should not reproduced except in full, written approval of ONETECH. FCC-003 (Rev.0) HEAD OFFICE : #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea (TEL: +82-31-746-8500, FAX: +82-31-746-8700) EMC Testing Dept : 426-1 Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904) ONETECH Testing & Evaluation Lab. FCC ID. : R2SEFC File No. : E053R-083 It should not reproduced except in full, written approval of ONETECH. FCC-003 (Rev.0) HEAD OFFICE : #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea (TEL: +82-31-746-8500, FAX: +82-31-746-8700) EMC Testing Dept : 426-1 Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904) ONETECH Testing & Evaluation Lab. FCC ID. : R2SEFC File No. : E053R-083 It should not reproduced except in full, written approval of ONETECH. FCC-003 (Rev.0) HEAD OFFICE : #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea (TEL: +82-31-746-8500, FAX: +82-31-746-8700) EMC Testing Dept : 426-1 Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904) ONETECH Testing & Eval…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 32 FCC ID. : R2SEFC File No. : E053R-083 It should not be reproduced except in full, without the written approval of ONETECH. EMC-007(Rev.0) HEAD OFFICE : #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Kyunggi-Do, 462-121, Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 426-1 Daessangryung-Ri, Chowol-Myun, Kwangju-Kun, Kyunggi-Do 464-860 Korea. (TEL: 82-31-765-8289 FAX: 82-31-766-2904) ONETECH Testing & Evaluation Lab. ELECTROMAGNETIC EMISSION C OMPLIANCE REPORT FOR PCS PRIVATE LAND MOBILE LICENSED DATA TRANSCEIVER Test report file number : E053R-083 Applicant : Hoseo Telnet Co., Ltd. Address : 157-033, 680 Deungcheon3-Dong, Kangseo-Gu, Seoul Korea Manufacturer : Hoseo Telnet Co., Ltd. Address : 157-033, 680 Deungcheon3-Dong, Kangseo-Gu, Seoul Korea Type of Equipment : Telemetry Equipment FCC ID. : R2SEFC Model Name : Eagle 2 Added Model Name : Condor 2 and Falcon 2 Serial number : None Total page of Report : 32 pages (including this page) Date of Incoming : March 15, 2005 Date of issue : March 31, 2005 SUMMARY The equipment complies with the regulation; FCC Part 24D and 90. This test report only contains the result of a single test of the sample supplied for the examination. It is not a generally valid assessment of the features of the respective products of the mass-production. Prepared by: Reviewed by: Y. M. Choi / Senior Engineer Y. K. Kwon/ Director RF/EMC Div. RF/EMC Div. ONETECH Corp. ONETECH Corp. Page 2 of 32 FCC ID. : R2SEFC File No. : E053R-083 It should not be reproduced except in full, without the written approval of ONETECH. EMC-007(Rev.0) HEAD OFFICE : #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Kyunggi-Do, 462-121, Korea (TEL: 82-31-746-8500 FAX: 82-31-746-8700) EMC Testing Dept : 426-1 Daessangryung-Ri, Chowol-Myun, Kwangju-Kun, Kyunggi-Do 464-860 Korea. (TEL: 82-31-765-8289 FAX: 82-31-766-2904) ONETECH Testing & Evaluation Lab. CONTENTS PAGE 1. VERIFICATION OF COMPLIANCE .............................................................................................4 2. TEST SUMMARY ..............................................................................................................................5 2.1 TEST ITEMS AND RESULTS..............................................................................................................................................5 2.2 ADDITIONS, DEVIATIONS, EXCLUSIONS FROM STANDARDS...........................................................................................5 2.3 RELATED SUBMITTAL(S) / GRANT(S)............................................................................................................................5 2.4 PURPOSE OF THE TEST...................................................................................................................................................5 2.5 TEST METHODOLOGY....................................................................................................................................................5 2.6 TEST FACILITY...............................................................................................................................................................5 3. GENERAL INFORMATION ............................................................................................................6 3.1 PRODUCT DESCRIPTION.................................................................................................................................................6 3.2 ALTERNATIVE TYPE(S)/MODEL(S); ALSO COVERED BY THIS TEST REPORT.................................................................7 4. EUT MODIFICATIONS ....................................................................................................................7 5. SYSTEM TEST CONFIGURATION ...............................................................................................7 5.1 JUSTIFICATION...............................................................................................................................................................7 5.3 PERIPHERAL EQUIPMENT...............................................................................................................................................7 5.4 MODE OF OPERATION DURING THE TEST.......................................................................................................................7 6. RF POWER OUTPUT AT ANTENNA TERMINAL .....................................................................8 6.1 OPERATING ENVIRONMENT...........................................................................................................................................8 6.2 TEST SET-UP...................................................................................................................................................................8 6.3 TEST EQUIPMENT USED..................................................................................................................................................8 6.4 TEST DATA......................................................................................................................................................................9 8. OCCUPIED BANDWIDTH, BANDWIDTH LIMITATION, EMISSION MASKS..................11 8.1 OPERATING ENVIRONMENT.........................................................................................................................................11 8.2 TEST SET-UP.................................................................................................................................................................11 8.3 TEST EQUIPMENT USED................................................................................................................................................11 8.4 TEST DATA......................................................................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID. : R2SEFC File No. : E053R-083 It should not reproduced except in full, written approval of ONETECH. FCC-003 (Rev.0) HEAD OFFICE : #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea (TEL: +82-31-746-8500, FAX: +82-31-746-8700) EMC Testing Dept : 426-1 Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904) ONETECH Testing & Evaluation Lab. Radiated Emission Test FCC ID. : R2SEFC File No. : E053R-083 It should not reproduced except in full, written approval of ONETECH. FCC-003 (Rev.0) HEAD OFFICE : #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea (TEL: +82-31-746-8500, FAX: +82-31-746-8700) EMC Testing Dept : 426-1 Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904) ONETECH Testing & Evaluation Lab. Radiated Emission Test

Contact Information

Applicant

KIM Chang Soo(Director)
[email protected]+82-2-2659-7345Fax: +82-2-3662-0937

Test Firm

ONETECH Corp.Gea-Won Lee
[email protected]82-31-765-8289Fax: 82-31-766-2904

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
29896 MHz - 901 MHz1.92 W7K25F1D1 ppm
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. Antenna gain including cable loss must not exceed 0 dBi , for purposes of 2.1043 and 2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and system installer must be provided with specific information required to satisfy RF exposure compliance.

Other Applications from HOSEOTELNET CO., LTD.

Pager - FCC ID R2SSMT1000 - HOSEOTELNET CO., LTD.
R2SSMT1000

Pager

May 01, 2012

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter
Pager - FCC ID R2SSMC200 - HOSEOTELNET CO., LTD.
R2SSMC200

Pager

Apr 23, 2012

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver
RF Module - FCC ID R2SATM300 - HOSEOTELNET CO., LTD.
R2SATM300

RF Module

May 25, 2006

Equipment Class

PCB - PCS Licensed Transmitter
ReFLEX 2-Way Messaging Device - FCC ID R2SHSD8000 - HOSEOTELNET CO., LTD.
R2SHSD8000

ReFLEX 2-Way Messaging Device

Jun 29, 2004

Equipment Class

PCT - PCS Licensed Transmitter worn on body