Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Guest Pager User’s Manual Contents 1. Components ......................................................... 3 2. Instructions ......................................................... 3 2.1 Installation .......................................................... 3 2.2 Operations .......................................................... 3 2.3 Before Use .......................................................... 4 3. Caution .......................................................... 4 4. Transmitter Instruction .......................................................... 5 4.1 Keypad Description .......................................................... 5 4.2 Paging Instruction .......................................................... 5 4.3 Preference .......................................................... 10 4.4 Other Features .......................................................... 17 5. Description of Coaster .......................................................... 20 6. Description of Staff Pager .......................................................... 21 6.1 Menu .......................................................... 21 6.2 Button Configuration .......................................................... 22 6.3 Functional Description .......................................................... 23 7. Care & Maintenance ................................................... .............. 24 2 1. Components 2. Instructions ※ Actual product might be different from the picture below. Transmitter Transmitter Antenna A/C Adaptor Coaster Coaster Base Coaster A/C Adaptor User’s Manual Staff Pager (optional) - Connect Antenna in to Transmitter.- Connect Transmitter A/C Adaptor in to Transmitter- Connect Transmitter A/C Adaptor in to power outlet . - Connect Coaster A/C Adaptor in to Coaster Base.- Connect Coaster A/C Adaptor in to power outlet.- Stack Coasters on top of Coaster Base. - Add AAA battery in to Staff Pager.- Coaster and Staff Pager will work once registered to the Transmitter. - Coaster cannot be programmed or paged unless pager is removed from the Coaster Base. - All the key functions can be used by adding an external USB keyboard on to the Transmitter. - Staff name and/or message input must be via USB keyboard. - Transmitter A/C Adaptor must be connected in order to use USB keyboard and must click space button on the transmitter to start. - SPACE & DEL key can be use as an up/down key from the Menu List. - Number key or Long key can be used from the Menu List for quick move. - Capable of handling up to 999 Coasters & Staff Pagers. ※Note : To save data, information can not be saved in “Low Battery” condition . We highly recommend that the A/C Adaptor is connected while the Transmitter is in use. 3 2.1 Installation 2.2 Operations - Follow the “Instructions” on page 3 to set up the e quipments. - If coaster is not registered please refer to page 11,1-6 “Pager Registration”. - Registration of Staff Pager is the same as Coaster but must use PIN #900 – #999 in order to add staff n ame. - To register staff name on the staff pager, refer t o page 12, 1-8 “Staff Name”. - To save canned message, refer to page 12, 1-10 “Canned Message Setting” - Once registration is done, refer to page 5, 4.2 “Paging Instruction” 4 3. Caution 3-1 . Safety Caution Use products safely to prevent any unexpected accid ents in advance. • Do not disassemble, repair, or modify. • Avoid direct heat.• Be sure to connect antenna before connecting to po wer. • Do not plug or unplug with wet hands.• Do not use if cord or plug appears to be damaged. * Connect to a properly grounded outlet only. • Only use provided adaptor.• Avoid humid and dusty area. * Place Transmitter on a solid surface and treat it carefully. • Avoid strong magnetic field.• USB connector on the transmitter is for USB Keyboa rd only. Warning Caution 2.3 Before Use ⑪ ⑩ ⑨ ⑧ ⑦ ⑥ ⑤ ④③ ⑫ ② ① ① : Antenna : Wireless transmission/reception antenna② : LCD Display : Displays menu, status & input key③ : CLEAR : Clears screen/back to previous menu④ : STAFF : Check registered staff⑤ : CALL : Paging ⑥ : ENTER : Complete menu selections and settings⑦ : INPUT : Select or input messages to page⑧ : READ : View call, message call, wait list & registered list ⑨ : MENU : Menu Entry⑩ : DEL : Deletes the last entered character ( use as down arrow key on the menu list) ⑪ : SPACE : Use as hyphen in group calling ( use as up arrow key on the menu list) ⑫ : Number Keypad : Input numbers 4. Transmitter Instruction 4.1 Keypad Description 4.2 Paging Instruction 1. Individual Calls 1-1. General Call - calling one Coaster and/or Staff Pager ex) calling coaster #7 Enter all calls from the main screen Main Screen ※ It will automatically go back to main screen if no input has been made from the menu or the sub-menu screen for 5 minutes. Number of Wait CountEstimated Wait TimeCurrent Time 5 1-2. Sending Message (Staff Pager) - using a canned message in the Transmitter ex) calling Staff Pager #910 by using canned message #3 or - text message ex) calling Staff Pager #910 by inputting new mess age via USB keyboard keyboard input or ※ Staff Pager must be registered between 900 to 999 in order to assign names. ※ USB keyboard must be connected to the Transmitter in order to input characters. ※ To use USB keyboard press key on the Transmitter before typing. 1-3. Call All Pagers - calling all registered Coasters and Staff Pagers a t once. - can be used in emergency ex) calling all registered pagers ※ All registered Coasters & Staff Pagers receives ca lls. ※ All calls including message can be sent by pressin g 0 and follow step 1-2 (Sending Message). ※ use user password (default 1111). 6 2. Group Calls 2-1. General Group Call (Coaster & Staff Pager) - calling consecutive numbers at once ex) calling Coaster #2 thru #7 2-2. Group Message Call (Staff Pager) - calling consecutive number of Staff Pagers by entering same messages. ex) calling Staff Pager #900 thru #910 by using canned message #2…
Text truncated - open the document above for the full version.
Hoseo Telnet Co., Ltd.. 680-3 Deungchon-3dong, Kangseo-gu, Seoul, Korea Tel: +82-2-2659-7345, Fax: +82-2-3669-0937 EMCCert DR. RAŠEK GmbH Date: March 30, 2012 Stoernhofer Berg 15 91364 Unterleinleiter GERMANY This authorization is valid until further written notice from the applicant. Sincerely Yours, Mr. C. H. Kim / Director Hoseo Telnet Co., Ltd. Tel : 82-2-2659-7345 Fax : 82-2-3662-0937 E-Mail: [email protected]
Hoseo Telnet Co., Ltd.. 680-3 Deungchon-3dong, Kangseo-gu, Seoul, Korea Tel: +82-2-2659-7345, Fax: +82-2-3669-0937 Date: March 30, 2012 FCC Laboratory 7435 Oakland Mills Road Columbia, MD 21046 Attention : Application Examiner / Reviewing Engineer Subject : Request for confidentiality per Section 0.457(d) and 0.459 of FCC Rules Applicant : HOSEOTELNET CO., LTD. FCC ID : R2SSMT1000 To whom it may concern, Request is hereby submitted, HOSEOTELNET CO., LTD., to withhold from public review certain portions of the application for equipment certification for the referenced FCC identifier. In particular, the following sections of the application and report are requested to be kept confidential: Schematics / Block Diagram / Operational Description / Parts List Rationale for request for confidentiality: HOSEOTELNET CO., LTD., has invested considerable time and materials in research and development to produce the referenced product. Disclosure of the confidential portions of this application to competitors would give them competitive advantage in developing similar products. If you have questions or need further information, please contact the undersigned. Sincerely Yours, Mr. C. H. Kim / Director HOSEOTELNET CO., LTD. Tel : 82-2-2659-7345 Fax : 82-2-3662-0937 E-Mail: [email protected]
Hoseo Telnet Co., Ltd.. 680-3 Deungchon-3dong, Kangseo-gu, Seoul, Korea Tel: +82-2-2659-7345, Fax: +82-2-3669-0937 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Attention: Application Examiner / Review Engineer Subject: DoC procedure attestation Reference: FCC ID: R2SSMT1000 Date: May 3, 2012 To The Commission, Hereby we attest that the device will be subject to a DoC procedure prior to marketing in the USA, as the device is a computer peripheral. Sincerely Yours, Mr. C. H. Kim / Director HOSEOTELNET CO., LTD. Tel : 82-2-2659-7345 Fax : 82-2-3662-0937 E-Mail: [email protected]
Page 1 of 4 Report No. : E124R-003 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) Page 2 of 4 Report No. : E124R-003 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) Page 3 of 4 Report No. : E124R-003 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) Page 4 of 4 Report No. : E124R-003 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904)
Page 1 of 1 Report No. : E124R-003 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) IDENTIFICATION LABEL: PROPOSED FCC ID LABEL The FCC ID shall be permanently affixed to the bottom side of the equipment FCC ID AREA This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operations. Made in Korea FCC ID : R2SSMT1000
Page 1 of 8 Report No. : E124R-003 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) Page 2 of 8 Report No. : E124R-003 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) Page 3 of 8 Report No. : E124R-003 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) Page 4 of 8 Report No. : E124R-003 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) Page 5 of 8 Report No. : E124R-003 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) Page 6 of 8 Report No. : E124R-003 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) Page 7 of 8 Report No. : E124R-003 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) Page 8 of 8 Report No. : E124R-003 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904)
Page 1 of 32 Report No. : E124R-003 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) ELECTROMAGNETIC EMISSION COMPLIANCE REPORT Test Report No. : E124R-003 AGR No. : A122A-153 Applicant : HOSEOTELNET CO., LTD. Address : 680-3 Deungchon-3dong, Kangseo-gu, Seoul, Korea Manufacturer : HOSEOTELNET CO., LTD. Address : 680-3 Deungchon-3dong, Kangseo-gu, Seoul, Korea Type of Equipment : Transmitter FCC ID. : R2SSMT1000 Model Name : SMT1000 Serial number : N/A Total page of Report : 31 pages (including this page) Date of Incoming : March 08, 2012 Date of issue : April 03, 2012 SUMMARY The equipment complies with the regulation; FCC Part 90 Subpart I. This test report only contains the result of a single test of the sample supplied for the examination. It is not a generally valid assessment of the features of the respective products of the mass-production. Prepared by: Reviewed by: Ki-Hong, Nam / Senior Engineer Y. K. Kwon / Exe. Managing Director ONETECH Corp. ONETECH Corp. Page 2 of 32 Report No. : E124R-003 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) CONTENTS PAGE 1. VERIFICATION OF COMPLIANCE.......................................................................................................................5 2. TEST SUMMARY......................................................................................................................................................6 2.1 TEST ITEMS AND RESULTS........................................................................................................................................6 2.2 ADDITIONS, DEVIATIONS, EXCLUSIONS FROM STANDARDS.......................................................................................6 2.3 RELATED SUBMITTAL(S) / GRANT(S).......................................................................................................................6 2.4 PURPOSE OF THE TEST.............................................................................................................................................6 2.5 TEST METHODOLOGY.............................................................................................................................................6 2.6 TEST FACILITY........................................................................................................................................................6 3. GENERAL INFORMATION.....................................................................................................................................7 3.1 PRODUCT DESCRIPTION..........................................................................................................................................7 3.2 ALTERNATIVE TYPE(S)/MODEL(S); ALSO COVERED BY THIS TEST REPORT...............................................................7 4. SYSTEM TEST CONFIGURATION.........................................................................................................................8 4.1 JUSTIFICATION........................................................................................................................................................8 4.2 PERIPHERAL EQUIPMENT........................................................................................................................................8 4.3 MODE OF OPERATION DURING THE TEST.................................................................................................................8 4.4 EQUIPMENT MODIFICATIONS..................................................................................................................................8 4.5 CONFIGURATION OF TEST SYSTEM..........................................................................................................................8 4.6 ANTENNA REQUIREMENT........................................................................................................................................9 5. PRELIMINARY TEST...............................................................................................................................................9 5.1 AC POWER LINE CONDUCTED EMISSIONS TESTS.....................................................................................................9 5.2 RADIATED EMISSIONS TESTS...................................................................................................................................9 6. RF POWER OUTPUT AT ANTENNA TERMINAL..............................................................................................10 6.1 OPERATING ENVIRONMENT...................................................................................................................................10 6.2 TEST SET-UP..........................................................................................................................................................10 6.3 TEST EQUIPMENT USED..........................................................................................................................................10 6.4 TEST DATA.............................................................................................................................................................11 7. OCCUPIED BANDWIDTH AND EMISSION MASK............................................................................................13 7.1 OPERATING ENVIRONMENT…
Text truncated - open the document above for the full version.
Page 1 of 4 Report No. : E124R-003 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) Conducted Emission Test Page 2 of 4 Report No. : E124R-003 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) Radiated Emission Test Page 3 of 4 Report No. : E124R-003 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) Page 4 of 4 Report No. : E124R-003 It should not be reproduced except in full, without the written approval of ONETECH. EMC-003 (Rev.2) HEAD OFFICE : 301-14 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMC Testing Dept : 307-51 Daessangnyeong-ri, Chowol-eup, Gwangju-si, Gyeonggi-do 464-862 Korea (TEL: 82-31-765-8289, FAX: 82-31-766-2904) RF Test
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 1 | 90 | 464.6 MHz - 464.75 MHz | 2.31 W | 8K54F1D | 0.7000000000 ppm |

Pager
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
RF Module
Equipment Class
PCB - PCS Licensed Transmitter
Telemetry Equipment
Equipment Class
PCB - PCS Licensed Transmitter
ReFLEX 2-Way Messaging Device
Equipment Class
PCT - PCS Licensed Transmitter worn on body