Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 Certification Exhibit FCC ID: R7PCGR1S2 FCC Rule Part: 15.247 ACS Project Number: 12-0230 Manufacturer: Landis+Gyr Technology, Inc. Model: BLT5 Manual PROPRIETARY INFORMATION NOTICE: THIS DOCUMENT CONTAINS TRADE SECRETS AND CONFIDENTIAL INFORMATION OFLANDIS+GYRAND SHALL NOT BE DUPLICATED IN WHOLE OR IN PART OR USED OR DISCLOSED FOR ANY PURPOSE OTHER THAN THAT APPROVED BYLANDIS+GYR. Assembly Instructions, Kit, BLT5 Transceiver, MCC, 97-1828 Revision History ECORevisionDateAuthorComments ECO-051889 AA8/20/2012Robert JohnsonInitial Release ECO-052962 AB4/10/2014Robert JohnsonModifcation to initial Release, added FCC statement Assembly Instructions, Kit, BLT5, MCC97-1828 Rev ABPage2of4 PROPRIETARY INFORMATION NOTICE: THIS DOCUMENT CONTAINS TRADE SECRETS AND CONFIDENTIAL INFORMATION OFLANDIS+GYRAND SHALL NOT BE DUPLICATED IN WHOLE OR IN PART OR USED OR DISCLOSED FOR ANY PURPOSE OTHER THAN THAT APPROVED BYLANDIS+GYR. CONTENTS 1INTRODUCTION ..................................................................................................................................................................3 2REMOVING THE EXISTING BLT3 TRANSCEIVER FROM THE MCC’S ENCLOSER...........................................3 3RE-INSTALLING THE UPDATED LAN/WAN BRACKET ASSEMBLY CONTAINING THE UPDATED BLT5 TRANSCEIVER UNIT INTO THE MCC ENCLOSER ..........................................................................................3 4.FINAL INSTALLATION ......................................................................................................................................................4 5.FCC................................................................................................................................................................4 Assembly Instructions, Kit, BLT5, MCC97-1828 Rev ABPage3of4 PROPRIETARY INFORMATION NOTICE: THIS DOCUMENT CONTAINS TRADE SECRETS AND CONFIDENTIAL INFORMATION OFLANDIS+GYRAND SHALL NOT BE DUPLICATED IN WHOLE OR IN PART OR USED OR DISCLOSED FOR ANY PURPOSE OTHER THAN THAT APPROVED BYLANDIS+GYR. 1Introduction 1.1 All MCCs updated in the field requiring replacement of their original BLT3 transceiver to the newly designed BLT5 transceiver must also be retro-fitted per the guidelines specified in this procedure. The MCC field update consists of removing the original BLT3 transceiver, and replacing it with the newly redesigned BLT5 transceiver. After the new BLT5 transceiver has been installed you will also need to install a new FCC label, part number 23-1401. The new FCC label should be placed on the MCC’s exterior where it will be highly visible. The new FCC, BLT5 Retrofit label can be found in the MCC retro-fit kit, designated as follows: Kit, BLT5 Transceiver, MCC kit, Landis part number 45-1828. The bill of materials is listed below. Kit, BLT5 Transceiver, MCC Part number 45-1828 item_numberitem_namequantity 23-1127LABEL,BLANK,UTILITY ID1 90-1002 BAG, 9"X12"X.004 CLEAR POLY BAG WITH ZIPPER2 97-1828Assembly Instructions, Kit, BLT5 Transceiver, MCC1 23-1401 Label, FCC, BLT5 Retrofit 1 26-1828 T/A, BLT5 Transceiver, MCC 0 1 1 2. Removing the existing BLT3 transceiver from the MCC’s enclosure 2.1 Refer to Landis document part number : 97-2350, MPI, REPACKAGED ASSEMBLY INSTRUCTION, section 3.0 through section 3.8 for details on how to remove the exisiting BLT3 transceiver module. 2.2. To remove the existing, original BLT3 transceiver, disconnect the antenna cables P/N: 19-0014, LAN/WAN Radio Power Cable assembly P/N 19-2351, and the LAN Data cables P/N: 19-2352. 2.3. Losen the LAN/WAN assembly backet’s machine-screw Hex-nuts. The stated Hex-nuts are used to hold down the LAN/WAN assembly to the inside of the MCC enclosure, then remove the LAN/WAN assembly from the MCC enclosure.Once the LAN/WAN assembly has been pulled from the MCC inclosure, losen the hex-nuts used to hold down the original BLT3 transceiver assembly to the LAN/WAN assembly mouting bracket, pull the BLT3 transciever for the LAN/WAN mounting bracket assembly, and replace the orignal BLT3 transceiver will the newly redesigned BLT5 transceiver assembly. 3. Re-installing the updated LAN/WAN bracket assembly containing the updated BLT5 transceiver unit into the MCC encloser 3.1 Once you have re-fitted the BLT5 transceiver on the LAN/WAN mounting bracket assembly, re- torque the mounting Hex-nuts used to hold the BLT5 assembly to the LAN/WAN mounting bracket, then, re-install the LAN/WAN mounting bracket assembly inside the MCC enclosure, and re-torque the LAN/WAN mounting bracket’s Hex-nuts. The stated Hex-nuts are used to mount the LAN/WAN bracket assembly down to the inside of the MCC enclosure. 3.2 On completion of re-installing the LAN/WAN bracket assembly containing the newly added BLT5 transceiver you can re-connect the antenna cables P/N: 19-0014, LAN/WAN Radio Power Cable assembly P/N 19-2351, and the LAN Data cable P/N: 19-2352, Assembly Instructions, Kit, BLT5, MCC97-1828 Rev ABPage4of4 PROPRIETARY INFORMATION NOTICE: THIS DOCUMENT CONTAINS TRADE SECRETS AND CONFIDENTIAL INFORMATION OFLANDIS+GYRAND SHALL NOT BE DUPLICATED IN WHOLE OR IN PART OR USED OR DISCLOSED FOR ANY PURPOSE OTHER THAN THAT APPROVED BYLANDIS+GYR. 4. Final Installation 4.1 From your MCC retro fit kit contained in a 9”x 12” zip lock bag, remove the newFCC, BLT5 Retrofit label, part number23-1401. Nextremove the label’s non-stick backing paper to expose the adhesive side of the lablel then stick the new FCC labelon the outside of the MCC’s enclosure. The label should be placed on the enclosure’s painted exterior bottom where it will be highly visible. 4.1 The MCC may be returned to service. 5. FCC This product shall comply with the FCC requirements listed in United States CFR Title 47, Part 15.109, 15.209 and15.247. The FCC tests should be performed with the meter module in the configuration s close to the typical field configuration as po…
Text truncated - open the document above for the full version.
30000 Mill Creek Avenue, Suite 100 | Alpharetta, GA 30022 Tel: +1 678 258 1637 | Fax: +1 678 258 1681 Date: June 16, 2014 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Rd. Columbia, MD 21046 Dear Sir or Madam: I hereby appoint Sam Wismer at Advanced Compliance Solutions, Inc. to act as our agent in the preparation of an application for equipment authorization of FCC ID:R7PCGR1S2to the FCC Rules and Regulations. I certify that all exhibits contained within this filing properly describe the device or system for which authorization is sought. I further certify that appropriate arrangements have been made to assure that production units of this equipment bearing the name and FCC IDENTIFIER listed in this application will continue to comply with the Commission's requirements. I further certify by signature below that no party (per 47 CFR 1.2002(b)) to the application is subject to a denial of Federal benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). This appointment also includes the authority to complete FCC Form 731 on our behalf and sign the application as an authorized agent. Sincerely, Name: Richard Timko Title: Quality Engineer
30000 Mill Creek Avenue, Suite 100 | Alpharetta, GA 30022 Tel: +1 678 258 1637 | Fax: +1 678 258 1681 CONFIDENTIALITY REQUEST Federal Communications CommissionDate: June 16, 2014 Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Gentlemen: Landis+Gyr Technology, Inc. respectfully requests confidentiality of certain materials provided with the submission of the “BLT5”under FCC ID:R7PCGR1S2in accordance with FCC Regulations 0.459. The confidentiality request applies to the System Block Diagram, Schematics, and Theory of Operation contained in this filing. 12-0230 – Schematics.pdf 12-0230 – System Block Diagram.pdf 12-0230 – Theory of Operation.pdf The “BLT5”has been developed at considerable effort and expense by Landis+Gyr Technology, Inc. These items are considered as Trade Secrets and therefore public access to the proprietary material could possibly result in duplication of equipment that could severely damage the company's business advantage. I appreciate your assistance in this matter. Sincerely, Name: Richard Timko Title: Quality Engineer June 16, 2014
5015 B. U. Bowman Dr. Buford, GA 30518 June 9, 2014 ACS TCB 5015 B.U. Bowman Drive Buford, GA 30518 Re: FCC ID: R7PCGR1S2 To Whom It May Concern: The following application is submitted on behalf of our client, Landis+Gyr Technology, Inc., for evaluation of their model BLT5 for certification under FCC Part 15.247. The BLT5 receives and transmits packets of data in half-duplex operation on the CellNet wireless LAN using the 900 MHz radio frequency band. The BLT5 receives packets from endpoints on one of two antenna inputs at a frequency of 917.58 MHz and outputs the packet data serially to the processor using an RS232 interface. The BLT5 was tested in full to the requirements of the aforementioned rules and was found to be in compliance. Sincerely, Sam Wismer Vice President, Technology Advanced Compliance Solutions, Inc.
30000 Mill Creek Avenue, Suite 100 | Alpharetta, GA 30022 Tel: +1 678 258 1637 | Fax: +1 678 258 1681 To:File From:Richard Timko Subject:BLT5, FCC ID: R7PCGR1S2 Limited Modular Approval RequestMay 13. 2014 Scope FCC Public NoticeDA 00-1407released June 26, 2000 communicated guidelines for products requesting modular approval. In particular, eight requirements were enumerated along with a request that each of the 8 be explained for any product requesting such approval. It is the purpose of this document to respond to those eight guidelines in regard to the Landis+Gyr product: BLT5. Modular Approval Requirements 1.1 RF Shielding The Landis+Gyr BLT5 module is self-shielding and is not dependent on any component or characteristic of the device into which it is embedded. Shielding is accomplished through a combination of metallic self-shielding components, copper planes, guards, and vias in the PCB. The result is a design that has been proven to be neither sensitive to outside influence nor capable of introducing interference into outside components. 1.2Buffered Modulation / Data Inputs The Landis+Gyr BLT5 module does not have external modulation or data inputs. Rather, the RF sections are driven by an on-board microprocessor which directly controls the RF data lines and operates so as to not allow excessive modulation. 1.3Power Supply Regulation The Landis+Gyr BLT5 module uses linear, low-dropout regulators to provide all the electronics with a supply that is fixed, even when the input voltage is varied. 1.4Antenna Requirement The Landis+Gyr BLT5 module utilizes external antennas which are connected by non-unique OSX-type connectors. Therefore, Limited Modular Approval is applicable. 1.5Stand-Alone Testing All testing on the Landis+Gyr BLT5 module was conducted standalone. No shields or enclosures were used, other than those fully integrated into the modules themselves. No ferrites were used on data or power lines during testing. These devices are DC powered, and exceed applicable conducted emission requirements. 1.6Labeling As indicated, each module will have its own FCC ID label. In addition, devices into which they are placed will have labels indicating that this module is contained within. Exact text will be as specified in the FCC Public Notice. 1.7Specific Rules and Operating Requirements The Landis+Gyr BLT5 module complies with all pertinent rules for its section. 1.8RF Exposure Requirements The Landis+Gyr BLT5 module complies with all exposure requirements. As a component used in the Utility industry, this product is not intended for use near human operators. 1.9In Reference to 15.212(b) The Landis+Gyr BLT5 module is always professionally installed and is not sold to the general public. It is always installed into controlled or non-accessible areas such as antenna towers and utility poles. This module undergoes continuous, rigorous testing to ensure that full compliance is always maintained. Sincerely, Title: Quality Engineer
5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 Certification Exhibit FCC ID: R7PCGR1S2 FCC Rule Part: 15.247 ACS Project Number: 12-0230 Manufacturer: Landis+Gyr Technology, Inc. Model: BLT5 Label Information 1 23 4 A B C D D 1 2 3 4 C A B 1.00 2.00 R.05 .10 .10 AA23-1401 LANDIS+GYR CONFIDENTIAL INFORMATION: THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO LANDIS + GYR FAMILY OF COMPANIES.(WHICH INCLUDES THE COMPANIES FORMERLY KNOWN AS HUNT AND CELLNET) ANY USE OR DISCLOSURE WITHOUT WRITTEN PERMISSION IS PROHIBITED. UNLESS OTHERWISE SPECIFIED: DIMENSIONS ARE IN INCHES [MM] DIMENSIONS ARE AFTER FINISH IS APPLIED ANGLE TOLERANCE DOES NOT APPLY TO IMPLIED 90 ANGLES TOLERANCES ON: DECIMAL FRACTION ANGLES 1PL .1 1/64 1 2PL .02 3PL .005 MUST BE FREE FROM FLASH AND BURRS. BREAK ALL SHARP EDGES. () DENOTES REFERENCE ONLY. REVISION: DRAWING NO. 1 OF 1 08/21/12 R. ADAMKIEWICZ-SOCHACKI THIRD ANGLE PROJECTION SHEET:DATED:DRAWN BY: B 08/21/12 D. FINCANNON SIZE: DATED:APPROVED BY: LABEL, FCC, BLT5 RETROFIT TITLE:DO NOT SCALE DRAWING NOTES: 1. MATERIAL: - .002" THICK WHITE POLYESTER (3M #7908FL OR 3M #MZ0058) WITH 3M #350 TYPE ADHESIVE WITH PROTECTIVE BACKING. - APPLY LAMINATE (.003" MATTE CLEAR POLYESTER, 3M #7735FL, OR CHANGMAO #OPATM/CL38) TO FACE OF LABEL AND OVER ALL PRINTING. 2. THIS LABEL SHALL BE IN ACCORDANCE WITH DOCUMENTS NUMBER 95-1062. SURFACES SHALL BE CONSIDERED "CLASS E" SURFACES UNLESS OTHERWISE SPECIFIED. 3. THIS LABEL SHALL BE IN ACCORDANCE WITH DOCUMENT NUMBER 95-1067 (LABEL SPECIFICATION). ARIAL 5PT, BLACK ARIAL 8PT, BLACK APPLY ADHESIVE TO OPPOSITE SIDE
5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 Certification Exhibit FCC ID: R7PCGR1S2 FCC Rule Part: 15.247 ACS Project Number: 12-0230 Manufacturer: Landis+Gyr Technology, Inc. Model: BLT5 Internal Photos Model: BLT5FCC ID: R7PCGR1S2 ACS Project: 12-0230Advanced Compliance SolutionsPage 2 Figure 1: Internal Photo – PCB Top Figure 2: Internal Photo – PCB Bottom
5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 Certification Exhibit FCC ID: R7PCGR1S2 FCC Rule Part: 15.247 ACS Project Number: 12-0230 Manufacturer: Landis+Gyr Technology, Inc. Model: BLT5 RF Exposure Model: BLT5FCC ID: R7PCGR1S2 ACS Project: 12-0230Advanced Compliance SolutionsPage 2 General Information: Applicant:Landis+Gyr Technology, Inc. Device Category:Mobile Environment:General Population/Uncontrolled Exposure Technical Information: Antenna Type: Omni-directional feed point Antenna Gain: 3dBi Maximum Transmitter Conducted Power: 25.43 dBm, 349.14 mW Maximum System EIRP: 28.43 dBm, 696.63 mW Exposure Conditions: Greater than 20 centimeters MPE Calculation The Power Density (mW/cm 2 ) is calculated as follows: S = 2 4R PG Where: S = power density (in appropriate units, e.g. mW/cm2) P = power input to the antenna (in appropriate units, e.g., mW) G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna (appropriate units, e.g., cm) MPE Calculator for Mobile Equipment Limits for General Population/Uncontrolled Exposure* 917.5825.430.61349.1431.995 200.139 Power Density (mW/cm^2) Distance (cm) Transmit Frequency (MHz) Radio Power (dBm) Power Density Limit (mW/Cm2) Radio Power (mW) Antenna Gain (dBi) Antenna Gain (mW eq.) Installation Guidelines The installation manual should contain text similar to the following advising how to install the equipment to maintain compliance with the FCC RF exposure requirements: RF Exposure In accordance with FCC requirements of human exposure to radio frequency fields, the radiating element shall be installed such that a minimum separation distance of 20 centimeters will be maintained. Conclusion This device complies with the MPE requirements by providing adequate separation between the device, any radiating structure and the general population.
5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 Certification Test Report FCC ID: R7PCGR1S2 FCC Rule Part: 15.247 ACS Report Number: 12-0230.W03.1A Manufacturer: Landis+Gyr Technology, Inc. Model: BLT5 Test Begin Date: May 29, 2012 Test End Date: October 29, 2013 Report Issue Date: June 16, 2014 FOR THE SCOPE OF ACCREDITATION UNDER LAB Code 200612-0 This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Reviewed by: Kirby Munroe Director, Wireless Certifications ACS, Inc. This test report shall not be reproduced except in full. This report may be reproduced in part with prior written consent of ACS, Inc. The results contained in this report are representative of the sample(s) submitted for evaluation. This report contains 19 pages 5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 TABLE OF CONTENTS 1GENERAL ............................................................................................................................................ 3 1.1PURPOSE.......................................................................................................................................... 3 1.2GENERAL......................................................................................................................................... 3 1.3TESTMETHODOLOGY ANDCONSIDERATIONS................................................................................. 3 2TEST FACILITIES.............................................................................................................................. 4 2.1LOCATION....................................................................................................................................... 4 2.2LABORATORYACCREDITATIONS/RECOGNITIONS/CERTIFICATIONS................................................ 4 2.3RADIATEDEMISSIONSTESTSITEDESCRIPTION.............................................................................. 5 2.3.1Semi-Anechoic Chamber Test Site .......................................................................................... 5 2.3.2Open Area Tests Site (OATS) ................................................................................................. 6 2.4CONDUCTEDEMISSIONSTESTSITEDESCRIPTION........................................................................... 7 3APPLICABLE STANDARD REFERENCES.................................................................................... 7 4LIST OF TEST EQUIPMENT............................................................................................................ 8 5SUPPORT EQUIPMENT .................................................................................................................... 9 6EQUIPMENT UNDER TEST SETUP BLOCK DIAGRAM ........................................................... 9 7SUMMARY OF TESTS ......................................................................................................................10 7.1ANTENNAREQUIREMENT–FCC:SECTION15.203 ........................................................................10 7.2POWERLINECONDUCTEDEMISSIONS–FCC:SECTION15.207,IC:RSS-GEN7.2.4......................10 7.2.1Measurement Procedure........................................................................................................10 7.2.2Measurement Results .............................................................................................................10 7.36DB/99%BANDWIDTH–FCC:SECTION15.247(A)(2),IC:RSS-210A8.2(A)..............................12 7.3.1Measurement Procedure........................................................................................................12 7.3.2Measurement Results .............................................................................................................12 7.4FUNDAMENTALEMISSIONOUTPUTPOWER–FCC:SECTION15.247(B)(3),IC:RSS-210A8.4(4).13 7.4.1Measurement Procedure........................................................................................................13 7.4.2Measurement Results .............................................................................................................13 7.5EMISSIONLEVELS–FCC:SECTION15.247(D),15.205IC:RSS-2102.2,A8.5 ..............................14 7.5.1Emissions into Non-restricted Frequency Bands...................................................................14 7.5.1.1Measurement Procedure ................................................................................................................... 14 7.5.1.2Measurement Results ....................................................................................................................... 14 7.5.2Emissions into Restricted Frequency Bands..........................................................................16 7.5.2.1Measurement Procedure ................................................................................................................... 16 7.5.2.2Measurement Results ....................................................................................................................... 16 7.5.2.3Sample Calculation: ......................................................................................................................... 17 7.6MAXIMUMPOWERSPECTRALDENSITY IN THEFUNDAMENTALEMISSION–FCC:SECTION 15.247(E)IC:RSS-210A8.2(B) .................................................................................................................18 7.6.1Measurement Procedure........................................................................................................18 7.6.2Measurement Results .............................................................................................................18 8CONCLUSION ....................................................................................................................................19 Model: BLT5F…
Text truncated - open the document above for the full version.
5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 Certification Exhibit FCC ID: R7PCGR1S2 FCC Rule Part: 15.247 ACS Project Number: 12-0230 Manufacturer: Landis+Gyr Technology, Inc. Model: BLT5 Test Setup Photos Model: BLT5FCC ID: R7PCGR1S2 ACS Project: 12-0230Advanced Compliance SolutionsPage 2 Figure 1: Radiated Emissions – XPOS Figure 2: Radiated Emissions – XPOS Model: BLT5FCC ID: R7PCGR1S2 ACS Project: 12-0230Advanced Compliance SolutionsPage 3 Figure 3: Radiated Emissions – YPOS Figure 4: Radiated Emissions – YPOS Model: BLT5FCC ID: R7PCGR1S2 ACS Project: 12-0230Advanced Compliance SolutionsPage 4 Figure 5: Radiated Emissions – ZPOS Figure 6: Radiated Emissions – ZPOS Model: BLT5FCC ID: R7PCGR1S2 ACS Project: 12-0230Advanced Compliance SolutionsPage 5 Figure 7: Conducted Emissions Figure 8: Conducted Emissions
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 917.58 MHz - 917.58 MHz | 350.00 mW |

S2 EIC WiFi Chip
Equipment Class
DTS - Digital Transmission System
Series-6 Gen-2 MCM0
Equipment Class
DTS - Digital Transmission System
Electricity Meter Module
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Series 5 mPCIe Module
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
LTE-M Cellular Communication Module
Equipment Class
DTS - Digital Transmission System