RAD002GSM 850/1900 Mobile Phone

TCT Mobile Limited
GSM 850/1900 Mobile Phone - FCC ID RAD002 - TCT Mobile Limited
Click to zoom

Application Details

Equipment Class
PCE - PCS Licensed Transmitter held to ear
Date of Grant
Nov 17, 2003
Application Purpose
Original Equipment
Date of Application
Nov 17, 2003
Equipment Note
GSM 850/1900 Mobile Phone
Frequency Range
1850.20000000 - 1909.80000000
Company
TCT Mobile Limited
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

English 3DS09782ABAA01 www.alcatel.com English ALCATEL BUSINESS SYSTEMS © 2003. All rights reserved. ALCATEL reserves the right, in customer's interest, to alter material or technical specifications without prior notice. BG3 _PCS_AUS_UM_27-08-03 27/08/03 17:44 Page 1 2 7. Directoriesp. 30 7.1Accessing your directoriesp. 30 7.2Creating a directory file p. 32 7.3Classifying a file in a family p. 33 7.4Available optionsp. 34 7.5Assigning a ring tone to a familyp. 36 7.6Temporary SIM cardp. 36 8. Messagesp. 37 8.1Accessing messagesp. 37 8.2Reading your messages p. 38 8.3Writing a messagep. 43 8.4Data entry system: predictive modep. 45 8.5Sending a messagep. 48 8.6Deleting your messagesp. 49 9. My setupp. 50 9.1Soundsp. 50 9.2Picturesp. 55 9.3Black/White background (Negat.Screen)p. 55 9.4Downloaded data (Downloaded)p. 56 9.5Zoomp. 57 9.6Numbersp. 57 10. Gamesp. 59 1 CONTENTS Safety and precautionsp. 4 Informationp. 9 1.Your telephonep. 11 1.1Keysp. 11 1.2Iconsp. 13 1.3Symbols used in the User Guidep. 14 2. Getting startedp. 15 2.1SIM Card and batteryp. 15 2.2Switching your phone onp. 18 2.3Switching your phone offp. 18 3. Callsp. 19 3.1Making a callp. 19 3.2Calling your voice mailp. 20 3.3Receiving a callp. 20 3.4Options available while callingp. 21 3.5Double line managementp. 24 4. Call memoryp. 25 5. MENUp. 26 6. Eventsp. 29 BG3 _PCS_AUS_UM_27-08-03 27/08/03 17:44 Page 1 4 SAFETY AND PRECAUTIONS We recommend that you read this chapter carefully before use. The manufacturer disclaims any liability for damage which may result as a consequence of improper use or use contrary to the instructions contained herein. •TRAFFIC SAFETY: Given recent studies, which show that using a mobile telephone while driving a vehicle constitutes a real risk, even when the hands-free kit is used (car kit, headset...), drivers are requested to refrain from using their mobile telephone when the vehicle is not parked. Your mobile phone when powered emits radiation which may interfere with the vehicle electronic systems such as anti-lock brakes (ABS, airbag). As a result, you should: -avoid placing the phone on the dashboard or within an airbag deployment area. -connect the phone to an external antenna or switch the phone off. The antenna should be mounted and located away from the driver and passengers or separated from them by a metal screen (e.g. the car roof). -check with the car manufacturer or your car dealer that the dashboard is adequately shielded from mobile phone RF energy. •CONDITIONS OF USE: Switch the phone off before boarding an aircraft to avoid prosecution. Switch the phone offwhen you are in health care facilities, except 3 11. Alarmsp. 63 11.1Wake upp. 63 11.2Appointmentsp. 64 11.3Birthdaysp. 64 11.4Optionsp. 64 12. Calculator/Converterp. 65 12.1Calculator p. 65 12.2Convertp. 66 13. Setupp. 68 13.1Services p. 68 13.2Clockp. 76 13.3Languagesp. 76 13.4Dictionaryp. 76 13.5Input modep. 77 13.6Displayp. 77 13.7Pickupp. 77 13.8Automatic power offp. 78 13.9Double line managementp. 78 13.10 Keypad lockp. 78 14.WAPp. 79 14.1Accessing WAP Servicesp. 79 14.2Available optionsp. 80 14.3Setting up your accessp. 82 14.4Launching WAPp. 84 15. Warrantyp. 85 16. Character setp. 88 17. Accessoriesp. 89 18.Troubleshootingp. 91 BG3 _PCS_AUS_UM_27-08-03 27/08/03 17:44 Page 3 6 • CHARGERS Mains powered chargers mains will operate within the temperature range: 0 to 40°C. The chargers designed for your mobile phone meet with the standard for safety of information technology equipment and office equipment use.They should be used for this purpose only. • RADIO WAVES: THIS MODEL PHONE MEETS THE GOVERNMENT’S REQUIREMENTS FOR EXPOSURE TO RADIO WAVES. Your mobile phone is a radio transmitter and receiver. It is designed and manufactured not to exceed the emission limits for exposure to radio-frequency (RF) energy. These limits are part of comprehensive guidelines and establish permitted levels of RF energy for the general population. The guidelines are based on standards that were developed by independent scientific organizations through periodic and thorough evaluation of scientific studies. The guidelines include a substantial safety margin designed to assure the safety of all persons, regardless of age and health. 5 in designated areas. As with many other types of equipment now in regular use, mobile telephones can interfere with other electrical or electronic devices, or equipment using radio frequency. When the phone is switched on, avoid placing it near a medical aid device, if you carry one, such as a pacemaker, one hearing aid or insulin pump. When using the phone you should hold it against the ear on the opposite side to the device, if any. Switch the phone off when you are near gas or flammable liquids. Strictly obey all signs and instructions posted in a fuel depot, gas station, or chemical plant, or in any potentially explosive atmosphere. Do not let small children use the phone without supervision. Do not attempt to open or repair it yourself. Use only Alcatel batteries, battery chargers, and accessories that are compatible with your phone model. (See Accessories List, chapter 17). Alcatel will not be held responsible if this is not respected. Do not allow your phone to be exposed to unfavourable environmental conditions (humidity, rain, infiltration of liquids, dust, sea air, etc). The manufacturer’s recommended operating temperature range is -10°C to + 55°C. Over 55°C the legibility of the phone’s display may be impaired, though this is temporary and not serious. •BATTERY: Before removing the battery from your phone, please make sure that the phone is switched off. Take precautions with the battery and do not attempt to open the battery (chemical substances may cause burns). Do not pierce, disassemble nor cause a short-circuit in a battery. Do not burn or dispose of a used battery in household waste or store it at temperatures above 60 °C. Batteries must be disposed of in accordance with locally applicable environm…

Text truncated - open the document above for the full version.

External Photos

CETECOM ICT Services GmbH Test report no..: 2_3404-01-01/03Issue Date: 2003-10-20Page 135 (154) Photographs of the equipment CETECOM ICT Services GmbH Test report no..: 2_3404-01-01/03Issue Date: 2003-10-20Page 136 (154) PHOTOGRAPH OF THE EQUIPMENT

Internal Photos

CETECOM ICT Services GmbH Test report no..: 2_3404-01-01/03Issue Date: 2003-10-20Page 138 (154) PHOTOGRAPH OF THE EQUIPMENT CETECOM ICT Services GmbH Test report no..: 2_3404-01-01/03Issue Date: 2003-10-20Page 139 (154) PHOTOGRAPH OF THE EQUIPMENT CETECOM ICT Services GmbH Test report no..: 2_3404-01-01/03Issue Date: 2003-10-20Page 140 (154) PHOTOGRAPH OF THE EQUIPMENT CETECOM ICT Services GmbH Test report no..: 2_3404-01-01/03Issue Date: 2003-10-20Page 141 (154) PHOTOGRAPH OF THE EQUIPMENT RF-board without shield

RF Exposure Info

TTI-P-G 158 Appendix for DASY Test-Report, Alcatel_ 6575_350: Calibration Data Appendix for the Report Dosimetric Assessment of the Alcatel One Touch 331a (FCC ID: RAD002) According to the FCC Requirements Calibration Data October 10, 2003 IMST GmbH Carl-Friedrich-Gauß-Str. 2 D-47475 Kamp-Lintfort Customer Alcatel Business Systems 32, avenue Kléber F-92707-Colombes Cedex This report shall not be reproduced except in full without the written approval of the testing laboratory.

RF Exposure Info

TTI-P-G 158 DASY Test-Report, Alcatel_6575_350a Page 1 of 42 Report Dosimetric Assessment of the Portable Device Alcatel One Touch 331a (FCC ID: RAD002) According to the FCC Requirements October 13, 2003 IMST GmbH Carl-Friedrich-Gauß-Str. 2 D-47475 Kamp-Lintfort Customer Alcatel Business Systems 32, avenue Kléber F-92707-Colombes Cedex The test results only relate to the items tested. This report shall not be reproduced except in full without the written approval of the testing laboratory. dasy_report_fcc_supplement_c _3.2.doc/16.06.2003/CH DASY Test-Report, Alcatel_6575_350a Page 2 of 42 dasy_report_fcc_supplement_c _3.2.doc/16.06.2003/CH H Executive Summary The One Touch 331a is a mobile phone (Portable Device) from Alcatel operating in the 800 MHz and 1900 MHz frequency range. The device has an integrated antenna. The system concepts used are the GSM 850 and PCS 1900 standards. The objective of the measurements done by IMST was the dosimetric assessment of one device in the GSM 850 and PCS 1900 standards. The examinations have been carried out with the dosimetric assessment system „DASY4“. The measurements were made according to the Supplement C to OET Bulletin 65 of the Federal Communications Commission (FCC) Guidelines [FCC 2001] for evaluating compliance of mobile and portable devices with FCC limits for human exposure (general population) to radiofrequency emissions. All measurements have been performed in accordance to the recommendations given by SPEAG. The Alcatel One Touch 331a mobile phone (FCC ID: RAD002) is in compliance with the Federal Communications Commission (FCC) Guidelines [FCC 2001] for uncontrolled exposure. The phone was tested in the Body Worn configuration with the following accessories and combinations: Belt clip and headset prepared by: ........................................... reviewed by: .............................................. André van den Bosch Dipl.-Ing. Christoph Hennes test engineer quality assurance engineer IMST GmbH Carl-Friedrich-Gauß-Straße 2 D-47475 Kamp-Lintfort Tel. +49- 2842-981 373 Fax +49- 2842-981 399 email: [email protected] DASY Test-Report, Alcatel_6575_350a Page 3 of 42 dasy_report_fcc_supplement_c _3.2.doc/16.06.2003/CH H Table of Contents 1 SUBJECT OF INVESTIGATION ................................................................................................................... 4 2 THE IEEE STANDARD C95.1 AND THE FCC EXPOSURE CRITERIA................................................. 4 2.1 DISTINCTION BETWEEN EXPOSED POPULATION, DURATION OF EXPOSURE AND FREQUENCIES...................... 4 2.2 DISTINCTION BETWEEN MAXIMUM PERMISSIBLE EXPOSURE AND SAR LIMITS................................................ 5 2.3 SAR LIMIT................................................................................................................................................... 5 3 THE FCC MEASUREMENT PROCEDURE ................................................................................................ 6 3.1 GENERAL REQUIREMENTS............................................................................................................................ 6 3.2 DEVICE OPERATING NEXT TO A PERSON’S EAR............................................................................................. 6 3.3 BODY-WORN AND OTHER CONFIGURATIONS................................................................................................. 9 4 THE MEASUREMENT SYSTEM ................................................................................................................ 10 4.1 PHANTOM.................................................................................................................................................. 12 4.2 PROBE....................................................................................................................................................... 12 4.3 MEASUREMENT PROCEDURE...................................................................................................................... 13 4.4 UNCERTAINTY ASSESSMENT........................................................................................................................ 14 5 SAR RESULTS ................................................................................................................................................ 15 6 EVALUATION ................................................................................................................................................ 18 7 APPENDIX ...................................................................................................................................................... 21 7.1 ADMINISTRATIVE DATA.............................................................................................................................. 21 7.2 DEVICE UNDER TEST AND TEST CONDITIONS.............................................................................................. 21 7.3 TISSUE RECIPES......................................................................................................................................... 22 7.4 MATERIAL PARAMETERS............................................................................................................................. 22 7.5 SIMPLIFIED PERFORMANCE CHECKING...................................................................................................... 23 7.6 ENVIRONMENT........................................................................................................................................... 29 7.7 TEST EQUIPMENT....................................................................................................................................... 29 7.8 CERTIFICATES OF CONFORMITY.................................................................................................................. 30 7.9 PICTURES OF THE DEVICE UNDER TEST.......................................................................…

Text truncated - open the document above for the full version.

RF Exposure Info

TTI-P-G 158 DASY Test-Report, Alcatel_6575_350_SAR Distribution Plots Page 1 of 28 Appendix for the Report Dosimetric Assessment of the Alcatel One Touch 331a (FCC ID: RAD002) According to the FCC Requirements SAR Distribution Plots October 10, 2003 IMST GmbH Carl-Friedrich-Gauß-Str. 2 D-47475 Kamp-Lintfort Customer Alcatel Business Systems 32, avenue KlÈber F-92707 Colombes Cedex The test results only relate to the items tested. This report shall not be reproduced except in full without the written approval of the testing laboratory. dasy_report_fcc_supplement_c _2.0.doc/25.09.2001 / CH DASY Test-Report, Alcatel_6575_350_SAR Distribution Plots Page 2 of 28 dasy_report_fcc_supplement_c _2.0.doc/25.09.2001/CH Table of Contents 1 SAR DISTRIBUTION PLOTS, GSM850........................................................................................................ 3 2 SAR DISTRIBUTION PLOTS, GSM 850 BODY WITH CLIP ................................................................... 9 3 SAR DISTRIBUTION PLOTS, GSM850 BODY WITH 1.5 CM DISTANCE TO THE PHANTOM .... 11 4 SAR DISTRIBUTION PLOTS, PCS 1900 HEAD........................................................................................ 13 5 SAR DISTRIBUTION PLOTS, PCS 1900 BODY WITH CLIP ................................................................. 17 6 SAR DISTRIBUTION PLOTS, PCS 1900 BODY WITH 1.5 CM DISTANCE TO THE PHANTOM... 19 7 SAR Z-AXIS SCANS (VALIDATION) ......................................................................................................... 21 8 SAR Z-AXIS SCANS (MEASUREMENTS) .................................................................................................25 DASY Test-Report, Alcatel_6575_350_SAR Distribution Plots Page 3 of 28 dasy_report_fcc_supplement_c _2.0.doc/25.09.2001/CH 1 SAR Distribution Plots, GSM850 Test Laboratory: IMST File Name: 331glm_1.da4 DUT: Alcatel ; Type: OT331a; Serial: 330587533874290 Communication System: GSM 850; Frequency: 836.6 MHz;Duty Cycle: 1:8 Medium: Head 835 MHz (σ = 0.89 mho/m, ε r = 42.1, ρ = 1000 kg/m 3 ) Phantom section: Left Section DASY4 Configuration: - Probe: ET3DV6 - SN1669; ConvF(6.8, 6.8, 6.8); Calibrated: 21.03.2003 - Sensor-Surface: 4mm (Mechanical And Optical Surface Detection) - Electronics: DAE3 Sn335; Calibrated: 05.05.2003 - Phantom: SAM TP:1059; Type: SAM; Serial: 1059 - Measurement SW: DASY4, V4.1 Build 47; Postprocessing SW: SEMCAD, V1.6 Build 115 cheek left/Area Scan (6x10x1): Measurement grid: dx=15mm, dy=15mm Reference Value = 29.3 V/m Power Drift = -0.09 dB Maximum value of SAR = 0.654 mW/g cheek left/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Peak SAR (extrapolated) = 1.25 W/kg SAR(1 g) = 0.674 mW/g; SAR(10 g) = 0.382 mW/g Reference Value = 29.3 V/m Power Drift = -0.09 dB Maximum value of SAR = 0.734 mW/g cheek left/Zoom Scan (7x7x7)/Cube 1: Measurement grid: dx=5mm, dy=5mm, dz=5mm Peak SAR (extrapolated) = 0.815 W/kg SAR(1 g) = 0.531 mW/g; SAR(10 g) = 0.35 mW/g Reference Value = 29.3 V/m Power Drift = -0.09 dB Maximum value of SAR = 0.59 mW/g Fig. 1: SAR distribution for GSM 850, channel 190, cheek position, left side of head. (October 06, 2003; Ambient Temperature: 20.8∞C; Liquid Temperature: 19.9∞C ). DASY Test-Report, Alcatel_6575_350_SAR Distribution Plots Page 4 of 28 dasy_report_fcc_supplement_c _2.0.doc/25.09.2001/CH Test Laboratory: IMST File Name: 331glm_2.da4 DUT: Alcatel ; Type: OT331a; Serial: 330587533874290 Communication System: GSM 850; Frequency: 836.6 MHz;Duty Cycle: 1:8 Medium: Head 835 MHz (σ = 0.89 mho/m, ε r = 42.1, ρ = 1000 kg/m 3 ) Phantom section: Left Section DASY4 Configuration: - Probe: ET3DV6 - SN1669; ConvF(6.8, 6.8, 6.8); Calibrated: 21.03.2003 - Sensor-Surface: 4mm (Mechanical And Optical Surface Detection) - Electronics: DAE3 Sn335; Calibrated: 05.05.2003 - Phantom: SAM TP:1059; Type: SAM; Serial: 1059 - Measurement SW: DASY4, V4.1 Build 47; Postprocessing SW: SEMCAD, V1.6 Build 115 tilted left/Area Scan (6x10x1): Measurement grid: dx=15mm, dy=15mm Reference Value = 24.6 V/m Power Drift = -0.02 dB Maximum value of SAR = 0.529 mW/g tilted left/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Peak SAR (extrapolated) = 0.862 W/kg SAR(1 g) = 0.503 mW/g; SAR(10 g) = 0.294 mW/g Reference Value = 24.6 V/m Power Drift = -0.02 dB Maximum value of SAR = 0.54 mW/g Fig. 2: SAR distribution for GSM 850, channel 190, tilted position, left side of head. (October 06, 2003; Ambient Temperature: 20.8∞C; Liquid Temperature: 19.9∞C ). DASY Test-Report, Alcatel_6575_350_SAR Distribution Plots Page 5 of 28 dasy_report_fcc_supplement_c _2.0.doc/25.09.2001/CH Test Laboratory: IMST File Name: 331grm_1.da4 DUT: Alcatel ; Type: OT331a; Serial: 330587533874290 Communication System: GSM 850; Frequency: 836.6 MHz;Duty Cycle: 1:8 Medium: Head 835 MHz (σ = 0.89 mho/m, ε r = 42.1, ρ = 1000 kg/m 3 ) Phantom section: Right Section DASY4 Configuration: - Probe: ET3DV6 - SN1669; ConvF(6.8, 6.8, 6.8); Calibrated: 21.03.2003 - Sensor-Surface: 4mm (Mechanical And Optical Surface Detection) - Electronics: DAE3 Sn335; Calibrated: 05.05.2003 - Phantom: SAM TP:1059; Type: SAM; Serial: 1059 - Measurement SW: DASY4, V4.1 Build 47; Postprocessing SW: SEMCAD, V1.6 Build 115 cheek right/Area Scan (6x10x1): Measurement grid: dx=15mm, dy=15mm Reference Value = 28.6 V/m Power Drift = -0.03 dB Maximum value of SAR = 0.751 mW/g cheek right/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Peak SAR (extrapolated) = 1.49 W/kg SAR(1 g) = 0.72 mW/g; SAR(10 g) = 0.396 mW/g Reference Value = 28.6 V/m Power Drift = -0.03 dB Maximum value of SAR = 0.797 mW/g Fig. 3: SAR distribution for GSM 850, channel 190, cheek position, right side of head, . (October 06, 2003; Ambient Temperature: 20.8∞C; Liquid Temperature: 19.9∞C ). DASY Test-Report, Alcatel_6575_350_SAR Distribution Plots Page 6 of 28 dasy_report_fcc_supplement_c _2.0.doc/25.09.2001/CH Test Laboratory: IMST File Name: 331grm_2.da4 DUT: Alcatel ; …

Text truncated - open the document above for the full version.

Test Report

CETECOM ICT Services GmbH Radio Satellite Communication Untertürkheimer Straße 6-10 . D-66117 SaarbrückenTelefon: +49 (0)681 598-9100Telefax: -9075 RSC11issue test report consist of 154 PagesPage 1 (154) BLUETOOTH TM is a trademark owned by Bluetooth SIG, Inc. and licensed to CETECOM Recognized by the Federal Communications Commission FCC–Identification Number: 90462 TCB ID: DE 0001 Accredited by the German Accreditation Council DAR–Registration Number TTI–P–G 166/98 Independent ETSI compliance test house ETSI Accredited Bluetooth™ Test Facility (BQTF) Test report no.: 2_3404-01-01/03 FCC Part 24/22/15 ONE Touch 331a FCC ID: RAD002 CETECOM – ICT Services GmbH Untertürkheimerstr. 6-10 66117 Saarbrücken, Germany Telephone: + 49 (0) 681 / 598-0 Fax: + 49 (0) 681 / 598-9075 CETECOM ICT Services GmbH Test report no..: 2_3404-01-01/03Issue Date: 2003-10-20Page 2 (154) Table of Contents 1 General information 1.1 Notes 1.2 Testing laboratory 1.3 Details of applicant 1.4 Application details 1.5 Test item 1.6 Test standards 2 Technical test 2.1 Summary of test results 2.2 Test report 1 General information 1.1 Notes The test results of this test report relate exclusively to the test item specified in 1.5. The CETECOM ICT Services GmbH does not assume responsibility for any conclusions and generalizations drawn from the test results with regard to other specimens or samples of the type of the equipment represented by the test item. The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report requires the prior written approval of the CETECOM ICT Services GmbH. 1.2Testing laboratory CETECOM ICT Services GmbH Untertürkheimer Straße 6 - 10 66117 Saarbrücken Germany Telefone: + 49 681 598 - 9100 Telefax : + 49 681 598 - 9075 E-mail: [email protected] Internet: www.cetecom-ict.de Accredited testing laboratory The Test laboratory (area of testing) is accredited according to DIN EN ISO/IEC 17025. DAR registration number: TTI-P-G-166/98 Listed by: Federal Communications Commission (FCC) Identification/Registration No : 90462 Accredited Bluetooth TM Test Facility (BQTF) BLUETOOTH TM is a trademark owned by Bluetooth SIG, Inc. and licensed to CETECOM CETECOM ICT Services GmbH Test report no..: 2_3404-01-01/03Issue Date: 2003-10-20Page 3 (154) 1.3Details of applicant Name : ALCATEL BUSINESS SYSTEMS Street : 32 avenue Kleber City : 92707 Colombes Country : France Telephone : +33 1 55 66 32 20 Telefax : + 33 1 55 66 64 02 Contact : Mr. Jean Fleuriot Telephone : +33 1 55 66 32 20 E-mail: [email protected] 1.4Application details Date of receipt of application : 2003-10-16 Date of receipt of test item : 2003-10-16 Date of test : 2003-10-16 to 2003-10-17 1.5Test item Type of equipment : Dual Band GSM Mobile Phone (PCS 850/1900 MHz) Type designation:One Touch 331a Manufacturer:Applicant Street: City: Country: Serial number:IMEI : 330587.53.387429.0 Additional informations: : Frequency:1850.2 – 1909.8 MHz and 824.2 – 848.8 MHz Type of modulation:300KGXW Number of channels :300 (PCS1900) and 125 (PCS850) Antenna:Integral antenna Power supply:3,7V DC NiMH Output power GSM 850:cond.: 32.70 dBm Peak , ERP: 28.8 dBm (Burst); EIRP: 30.9 dBm (Burst) Output power GSM 1900 :cond : 30.0 dBm Peak , ERP: 29.8 dBm (Burst); EIRP: 31.9 dBm (Burst) Type of equipment:Temperature range : -30°C - +60°C FCC – ID: RAD002 IC : - Hardware:01 Software:00 1.6Test standards: FCC Part 24, 22 FCC Part 15 CETECOM ICT Services GmbH Test report no..: 2_3404-01-01/03Issue Date: 2003-10-20Page 4 (154) 2 Technical test For Part 24/22 we use the substitution method ( TIA/EIA 603). Measurements were performed with vertical and horizontal polarisation and max hold function. Maximum peaks were found at vertical setting. This is valid for GSM 850 and for GSM 1900. All measurements in this report are done in GSM mode. 2.1 Technical details We had some accessories for the mobile to test according to FCC part15. - Charger SR Leader 220V 3DS 09371AAAA - Charger SR ASTEC 220V 3DS 09371AAAA - Charger SR Leader 110V 3DS 09371AGAA - Charger SR ASTEC 110V 3DS 09371AGAA - Travel charger 220 / 110V 3DS08217AAAA - Headset Leemax 3DS 07855AAAA - Headset Merry 3DS 07855AAAA - Headset Innovi 3DS 07855AAAA - SMS Keyboard 3DS 07237AAAA - Cigar lighter charger 3DS 07848AAAA - Handsfree Car Kit Primax MP86 So we made different setups for testing - Setup1: Mobile with charger SR Leader 220V and keyboard - Setup2: Mobile with charger SR ASTEC 220V and headset Merry - Setup3: Mobile with Travel charger and headset Innovi - Setup4: Mobile with charger SR Leader 110V and headset Leemax - Setup5: Mobile with charger SR ASTEC 110V and keyboard - Setup 6: Mobile with cigar lighter charger and headset Leemax - Setup7: Mobile with car kit Primax We did the radiated measurements above 30 MHz for GSM 850 and GSM 1900 with Setup1. Magnetic measurements were made with each setup, AC conducted measurements were made with setup1 to setup5. CETECOM ICT Services GmbH Test report no..: 2_3404-01-01/03Issue Date: 2003-10-20Page 5 (154) 2.2Summary of test results No deviations from the technical specification(s) were ascertained in the course of the tests performed. FINAL VERDICT: PASS Technical responsibility for area of testing : 2003-10-20RSC 8414 Ames H. DateSectionNameSignature Technical responsibility for area of testing : 2003-10-20RSC8412Hausknecht D. DateSectionNameSignature CETECOM ICT Services GmbH Test report no..: 2_3404-01-01/03Issue Date: 2003-10-20Page 6 (154) 2.3Test report TEST REPORT Test report no. : 2_3404-01-01/03 CETECOM ICT Services GmbH Test report no..: 2_3404-01-01/03Issue Date: 2003-10-20Page 7 (154) TEST REPORT REFERENCE PARAMETER TO BE MEASURED PAGE Part 24 PCS 19009 POWER OUTPUT SUBCLAUSE § 24.2329 FREQUENCY STABILITY SUBCLAUSE § 24.23511 AFC FREQ ERROR vs. VOLTAGE12 AFC FREQ ERROR vs. TEMPERATURE12 EMISSIONS LIMITS §24.23814 CONDUCTED SPURIOUS EMISSIONS27 BLOCK EDGE COMPLIANCE FOR BLOCK A AND C…

Text truncated - open the document above for the full version.

Test Setup Photos

CETECOM ICT Services GmbH Test report no..: 2_3404-01-01/03Issue Date: 2003-10-20Page 132 (154) TEST SETUP Radiated emissions CETECOM ICT Services GmbH Test report no..: 2_3404-01-01/03Issue Date: 2003-10-20Page 133 (154) TEST SETUP Radiated emissions CETECOM ICT Services GmbH Test report no..: 2_3404-01-01/03Issue Date: 2003-10-20Page 134 (154) Test site Conducted emissions

Contact Information

Applicant

Zhizhou Gong
[email protected]+86(0)2151798260Fax: +86(0)2161460600

Test Firm

Cetecom ICT Services GmbHRalf Hoehn
[email protected]49-681-598-8455Fax: 49-681-598-8475

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
224E1.85 GHz - 1.91 GHz1.56 W300KGXW44 Hz
Confidentiality
Long Term
Grant Notes
Power listed is ERP for part 22 and EIRP for part 24. This filing is only applicable for GSM 850/1900 operations. SAR compliance for body-worn operating configurations is limited to the specific configuration tested for filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic and a minimum distance of 15 mm to the body. End-users must be provided with the appropriate information for satisfying RF exposure compliance. Highest reported SAR values are: Part 24 - Head: 0,264 W/kg, Body: 0.564 W/kg; Part 22 - Head: 0.674 W/kg, Body: 0.682 W/kg.

Other Applications from TCT Mobile Limited

HSUPA/HSDPA/UMTS tribands / GSM quadbands/LTE 6-band mobile phone - FCC ID RAD558 - TCT Mobile Limited
RAD558

HSUPA/HSDPA/UMTS tribands / GSM quadbands/LTE 6-band mobile phone

Nov 15, 2015

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
CDMA 1X BC0/BC1/BC10 mobile phone - FCC ID RAD556 - TCT Mobile Limited
RAD556

CDMA 1X BC0/BC1/BC10 mobile phone

Sep 08, 2015

Equipment Class

PCE - PCS Licensed Transmitter held to ear
GSM Quadband / UMTS Triband mobile phone - FCC ID RAD552 - TCT Mobile Limited
RAD552

GSM Quadband / UMTS Triband mobile phone

Jun 20, 2015

Equipment Class

PCE - PCS Licensed Transmitter held to ear
HSDPA/HSUPA/HSPA+/UMTS quad band /GSM quad band/LTE 4 band mobile phone - FCC ID RAD550 - TCT Mobile Limited
RAD550

HSDPA/HSUPA/HSPA+/UMTS quad band /GSM quad band/LTE 4 band mobile phone

Jun 06, 2015

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
WCDMA tri band / GSM quad band Moblie phone with BT, Wi-Fi functionality. - FCC ID RAD549 - TCT Mobile Limited
RAD549

WCDMA tri band / GSM quad band Moblie phone with BT, Wi-Fi functionality.

May 13, 2015

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter