FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. TCT Mobile Limited/
  3. RAD131

RAD131GSM850 / PCS1900 Dual Band Mobile Phone

TCT Mobile Limited
GSM850 / PCS1900 Dual Band Mobile Phone - FCC ID RAD131 - TCT Mobile Limited
Click to zoom

Application Details

Equipment Class
PCE - PCS Licensed Transmitter held to ear
Date of Grant
Mar 20, 2010
Application Purpose
Original Equipment
Date of Application
Mar 18, 2010
Equipment Note
GSM850 / PCS1900 Dual Band Mobile Phone
Frequency Range
1850.20000000 - 1909.80000000
Company
TCT Mobile Limited
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1 You r telephone............ OT-105AOT-208A 1.1 Keys ( 1)(2) N av igation key Confirman opti on (pr ess the middle of the key) Manualswit ch lights ( 1) (longkeypressin main s cre en) Acc ess fa voritecontact(s) (2) (lon g keypressin main screen) Sendcall Accessto ca ll log (Idlescreen) A ct iva te Fakecall (l ong pr ess) P oweron/offthe handset (longpr ess) End call Returnto idle Left softkey Rightsoftkey Dialthe voicemailnumber(longkeypress) In edit mode - Shortkeypress:acc ess the languagelist - Longkeypress: enterze ro I n Edit mode: - Shortkeypress:change inputmethods - Longkeypress: accessthe Sy mbolstabl e Fro m main screen - Shortkeypress:# - Longkeypress: activate/deactivate the vibr ato r In edit mode: - Shortkeypress:(space) - Longkeypress: add a word Fro m Idle scre en (witha SIM card) - Shortpress:dial ‘5’ - Longpress:switchon/off the torch 8.4 Alarm Your cellphonehas a bui lt-inalarmclockwi th a sno oze fea ture. 8.5 Calculator Hold do wn thekey to get the deci ma l po int. Confirmwiththe / key or the le ft soft key. 8.6 Converter Unit con verterand Currency converter. 8.7 Fa ke Call Protect yourselffromannoyingsituationswiththe “Fake Call”. In this meun,you can set “Caller' s name”, “Call time” and “Ring tone”. Whenthe timerreac hes,the cel lphonewillringanddis playlike rec eivi ng a rea l cellphonecall. Presskey, pretendansweringa call, the sc reenwill displayjust lik e havean ongoing call. Presskey, pretendreje ct the call, the call will terminateautomatically. 8.8 To rch To lightin darkness,youmayac tivate“Tor ch” by belowopera tio ns: Long presskey to ac tivatethe Torchlig ht; sho rt presskey or Longpresskey to dea ctivateit. 1. 2 Main screen icons Batte ry ch arge level. ( 2)(3) Vib ra tio n alert: yource llphonevibrates,but ne itherrings nor beepsexceptfor the alarms. H ea dset co nne ct ed (3) . Cal l forwa rdi ng activated: yo ur ca lls are fo rwa rded. A larm clo ck pr ogrammed. Voi ce mail message arrived. FM radio is on ( 3) . U nansweredcalls ( 3) . Roaming. L evel of ne twork reception. ( 2)(3) Silence mode: yourcellphoneneither rings,beepsnor vibratesexceptfor the alarms. Mes sage unrea d. Keypad locke d. S topwatch is active ( 3) . Rin gton e ale rt. Vib ra tio n and ringtonealer t ( 3) . 9 Games (1) ..... ........... Yo ur Al catelcellphonemayincludesomegames. 9.1 Game se tt ings It allowsyouto managesettings,in whichyoumayset ba ckground audioand vibratio n alert. 10 FM Radio (2) ...... ...... (2) Yo ur cel lphoneis equippedwi th an FM ra dio (3) with RDSfunctionali ty. Yo u can use the application as a traditionalFM radiowit h automatic tuningand savedchannels or wit h parallel visua l informationrela ted to the radioprog ramon the display,if you tuneto stations thatoffer VisualRadioservice.Youcanliste n to it whilerunningother app lications. 11 My shortcuts.. (1)(2) Ac cessthe sho rtcutsal re ady programmed.To programnewshortcuts: select“Add” if youwantto createa quickaccessto functions, Numbers,Channellist, etc. 3 Calls .............................. 3.1 Makinga call D ial the desirednumberthenpre ss thekey to placethe call. If you makea mi stake,you can dele te the incorrectdigitsby pressingthe rightsoftkey. To hangup the call, pressthekey. Makingan emerg ency call I f yourcel lpho ne is covered by the network,dial emergencynumber and pressthekey to makean emergencyca ll. Thisworks even withouta SIM ca rd and withouttypingthe PIN code or unlockingthe k eypad. 3 .2 Calling yo ur voicemail ( 1) T o acce ss yourvoicemail , holddownthekey. 3.3 Receivinga call When you receivean incoming call, pressthekey to talk and t hen hangup usingthekey. 3.4 Availablefunctionsduring the call Du ring a call, you ca n use yourdirectory,shortmessages, etc. without los ing you r co rrespondent. 12 Profiles.................... With this menu,you ma y per sonalizeringtonesfo r di fferenteventsand environments. 13 Services........................ Contactyo ur networkoperatorto chec k serviceavailability. 14 Latin input mode ........ To writemessages,thereare twowrit ing methods: - Normal: this modeall ow s you to type a textby choosinga letteror a sequenceof characters associatedwitha key . Pressthe key several timesuntilthe desired letteris highlighted.Whenyou rel easethe key the highlightcharacteris inse rtedinto the text. - Predictivewithth e Zi mode:this mo de speedsup the writingof yourtext.Writethe wordby pressinga key betweenand . Pre ss the key onceand the wordwill be modifiedea ch time you pressa key . As you go on, the wordwill kee p changing . Example: For “Tomorrow”, pre ss on the followingkeys: ,,= Too ->-> tomorrow -ke y in edit mode Shortkeypress:ac cessthe languagelist Long keyp ress: enterze ro 4 Call re gister .......... 4 .1 Unan swered In this meun,yo u can find the unansweredca lls list. 4.2 Outgo ing ca lls I n this meun,yo u can find the outgoingcalls list. 4 .3 Answered calls I n this menu,you ca n find the answeredcal ls list. 4.4 My nu mbers Typ e in or modifyyourcellphonenumberor the numberto access y ou r voi cemailandconfirmby pressing /. Yourcellphone numberis usuallywritten on yourSIM car d. 4.5 Billing Y ou can accessdifferent ite ms withthis option:Amount,Duration. 4.6 Call settings You can accessa numberof it emswiththisoption:Caller ID, Call waiting,Callfo rwa rd, Answer mode,Callbarring... 4.7 Call control (1) The menuservesyouthe dualpurposesof costmonitoringand controllingduringa cal l by thesett ingsof “By cost” and“By dura tion”. 12 ( 1) Dependingon yournetworkoperator. (2) OT-1 05Aonly. (3) OT-2 08Aonly. 3 456 5 Direct ory ..... .... ....... 5.1 Con su lt ing your dire ctory To accessthedirecto ryfromthe mainscreen,pressthe/key and selecttheic on fr om the menu. 5.2 Addin g a cont act Se lectthe directoryin whichyouwishto cre ate a file , pre ss the “Options” softkey,se lec t “Add con tact” then /. 6 Messages..... .... ....... 6.1 Create SM S Fr om th e mainmenusel ect “Messages” to createtextmessage. You cantypea message , andyou'rea…

Text truncated - open the document above for the full version.

External Photos

RAD131 External photo

ID Label/Location Info

RAD131 EUT Label Location

Internal Photos

RAD131 Internal photo

RF Exposure Info

No.2010SAR00016 Page 1 of 94 ©Copyright. All rights reserved by TMC Beijing. SAR TEST REPORT No. 2010SAR00016 For TCT Mobile Limited GSM850/PCS1900 dual band Mobile Phone U10 B&W US OT-105A With Hardware Version: Proto Software Version: V613 FCCID: RAD131 Issued Date: 2010-03-12 No. DAT-P-114/01-01 Note: The test results in this test report relate only to the devices specified in this report. This report shall not be reproduced except in full without the written approval of TMC Beijing. Test Laboratory: TMC Beijing, Telecommunication Metrology Center of MIIT No. 52, Huayuan Bei Road, Haidian District, Beijing, P. R. China 100191. Tel:+86(0)10-62304633-2079, Fax:+86(0)10-62304793 Email:[email protected]. www.emcite.com No.2010SAR00016 Page 2 of 94 TABLE OF CONTENT 1 TEST LABORATORY..................................................................................................................3 1.1 TESTING LOCATION........................................................................................................................................ 3 1.2 TESTING ENVIRONMENT................................................................................................................................. 3 1.3 PROJECT DATA............................................................................................................................................... 3 1.4 SIGNATURE..................................................................................................................................................... 3 2 CLIENT INFORMATION..............................................................................................................4 2.1 APPLICANT INFORMATION.............................................................................................................................. 4 2.2 MANUFACTURER INFORMATION..................................................................................................................... 4 3 EQUIPMENT UNDER TEST (EUT) AND ANCILLARY EQUIPMENT (AE) ................................5 3.1 ABOUT EUT ................................................................................................................................................... 5 3.2 INTERNAL IDENTIFICATION OF EUT USED DURING THE TEST.......................................................................... 5 3.3 INTERNAL IDENTIFICATION OF AE USED DURING THE TEST............................................................................. 5 4 CHARACTERISTICS OF THE TEST ..........................................................................................5 4.1 APPLICABLE LIMIT REGULATIONS.................................................................................................................. 5 4.2 APPLICABLE MEASUREMENT STANDARDS...................................................................................................... 5 5 OPERATIONAL CONDITIONS DURING TEST ..........................................................................6 5.1 SCHEMATIC TEST CONFIGURATION................................................................................................................. 6 5.2 SAR MEASUREMENT SET-UP.......................................................................................................................... 6 5.3 DASY4 E-FIELD PROBE SYSTEM..................................................................................................................... 7 5.4 E-FIELD PROBE CALIBRATION........................................................................................................................ 8 5.5 OTHER TEST EQUIPMENT...............................................................................................................................9 5.6 EQUIVALENT TISSUES................................................................................................................................... 10 5.7 SYSTEM SPECIFICATIONS.............................................................................................................................. 10 6 LABORATORY ENVIRONMENT .............................................................................................. 11 7 CONDUCTED OUTPUT POWER MEASUREMENT................................................................. 11 7.1 SUMMARY.................................................................................................................................................... 11 7.2 CONDUCTED POWER.................................................................................................................................... 11 8 TEST RESULTS ........................................................................................................................12 8.1 DIELECTRIC PERFORMANCE......................................................................................................................... 12 8.2 SYSTEM VALIDATION.................................................................................................................................... 12 8.3 SUMMARY OF MEASUREMENT RESULTS....................................................................................................... 13 8.4 CONCLUSION................................................................................................................................................ 15 9 MEASUREMENT UNCERTAINTY ............................................................................................15 10 MAIN TEST INSTRUMENTS ..................................................................................................17 ANNEX A MEASUREMENT PROCESS....................................................................................18 ANNEX B TEST LAYOUT .........................................................................................................19 ANNEX C GRAPH RESULTS...................................................................................................…

Text truncated - open the document above for the full version.

RF Exposure Info

No.2010SAR00016 Page 76 of 94 No.2010SAR00016 Page 77 of 94 ANNEX F DIPOLE CALIBRATION CERTIFICATE 835 MHz Dipole Calibration Certificate No.2010SAR00016 Page 78 of 94 No.2010SAR00016 Page 79 of 94 No.2010SAR00016 Page 80 of 94 No.2010SAR00016 Page 81 of 94 No.2010SAR00016 Page 82 of 94 No.2010SAR00016 Page 83 of 94 No.2010SAR00016 Page 84 of 94 No.2010SAR00016 Page 85 of 94 No.2010SAR00016 Page 86 of 94 1900 MHz Dipole Calibration Certificate No.2010SAR00016 Page 87 of 94 No.2010SAR00016 Page 88 of 94 No.2010SAR00016 Page 89 of 94 No.2010SAR00016 Page 90 of 94 No.2010SAR00016 Page 91 of 94 No.2010SAR00016 Page 92 of 94 No.2010SAR00016 Page 93 of 94 No.2010SAR00016 Page 94 of 94

RF Exposure Info

Appendix A: SPEAG’s new calibration certifications Appendix B: SPEAG’s Evaluation report

Test Report

No.2010TAR052 Page1 of 50 ©Copyright. All rights reserved by TMC Beijing. TEST REPORT No. 2010TAR052 for TCT Mobile Limited GSM850/PCS1900 dualband Mobile Phone Model Name: U10 B&W US Marketing Name : OT-105A FCC ID: RAD131 with Hardware Version: Proto Software Version: V613 Issued Date: Mar 3 rd , 2010 Note: The test results in this test report relate only to the devices specified in this report. This report shall not be reproduced except in full without the written approval of TMC Beijing. Test Laboratory: DAR accreditation (DIN EN ISO/IEC 17025): No. DAT-P-114/01-01 FCC 2.948 Listed: No.733176 IC O.A.T.S listed: No.6629A-1 TMC Beijing, Telecommunication Metrology Center of Ministry of Industry and Information Technology No. 52, Huayuan Bei Road, Haidian District, Beijing, P. R. China 100083. Tel:+86(0)10-62303288-2105, Fax:+86(0)10-62304793 Email:[email protected]. www.emcite.com No.2010TAR052 Page2 of 50 ©Copyright. All rights reserved by TMC Beijing. CONTENTS 1. TEST LABORATORY .............................................................................................................. 3 1.1. TESTING LOCATION .......................................................................................................... 3 1.2. TESTING ENVIRONMENT .................................................................................................. 3 1.3. PROJECT DATA .................................................................................................................. 3 1.4. SIGNATURE ........................................................................................................................ 3 2. CLIENT INFORMATION .......................................................................................................... 4 2.1. APPLICANT INFORMATION............................................................................................... 4 2.2. MANUFACTURER INFORMATION ..................................................................................... 4 3. EQUIPMENT UNDER TEST (EUT) AND ANCILLARY EQUIPMENT (AE) ............................ 5 3.1. ABOUT EUT ........................................................................................................................ 5 3.2. INTERNAL IDENTIFICATION OF EUT USED DURING THE TEST ................................... 5 3.3. INTERNAL IDENTIFICATION OF AE USED DURING THE TEST ...................................... 5 3.4. GENERAL DESCRIPTION .................................................................................................. 6 4. REFERENCE DOCUMENTS .................................................................................................. 6 4.1. REFERENCE DOCUMENTS FOR TESTING ...................................................................... 6 5. LABORATORY ENVIRONMENT ............................................................................................ 7 6. SUMMARY OF TEST RESULTS ............................................................................................. 8 7. TEST EQUIPMENTS UTILIZED .............................................................................................. 8 ANNEX A: MEASUREMENT RESULTS ........................................................................................ 9 A.1 OUTPUT POWER ............................................................................................................... 9 A.2 EMISSION LIMT ............................................................................................................... 12 A.3 CONDUCTED EMISSION ................................................................................................. 26 A.4 FREQUENCY STABILITY ................................................................................................. 28 A.5 OCCUPIED BANDWIDTH ................................................................................................ 30 A.6 EMISSION BANDWIDTH .................................................................................................. 34 A.7 BAND EDGE COMPLIANCE ............................................................................................ 38 A.8 CONDUCTED SPURIOUS EMISSION ............................................................................. 40 No.2010TAR052 Page3 of 50 ©Copyright. All rights reserved by TMC Beijing. 1. Test Laboratory 1.1. Testing Location Company Name: TMC Beijing, Telecommunication Metrology Center of MIIT Address: No 52, Huayuan beilu, Haidian District, Beijing,P.R.China Postal Code: 100083 Telephone: 00861062303288 Fax: 00861062304793 1.2. Testing Environment Normal Temperature: 15-35°C Relative Humidity: 20-75% 1.3. Project data Testing Start Date: Feb 10 th , 2010 Testing End Date: Feb 23 th , 2010 1.4. Signature Zi Xiaogang (Prepared this test report) Sun Xiangqian (Reviewed this test report) Lu Bingsong Deputy Director of the laboratory (Approved this test report) No.2010TAR052 Page4 of 50 ©Copyright. All rights reserved by TMC Beijing. 2. Client Information 2.1. Applicant Information Company Name: TCT Mobile Limited Address /Post: 4F, South Building, No.2966, JinKe Road, Zhangjiang High-Tech Park City: Shanghai Postal Code: 201203 Country: P.R.China Telephone: 0086 2161460890 Fax: 0086 2161460602 2.2. Manufacturer Information Company Name: TCT Mobile Limited Address /Post: 4F, South Building, No.2966, JinKe Road, Zhangjiang High-Tech Park City: Shanghai Postal Code: 201203 Country: P.R.China Telephone: 0086 2161460890 Fax: 0086 2161460602 No.2010TAR052 Page5 of 50 ©Copyright. All rights reserved by TMC Beijing. 3. Equipment Under Test (EUT) and Ancillary Equipment (AE) 3.1. About EUT Description GSM850/PCS1900 dualband Mobile Phone Model Name U10 B&W US Marketing Name OT-105A Brand ALCATEL FCC ID RAD131 Frequency GSM 850MHz; PCS 1900MHz Antenna Internal Power supply Battery or Charger (AC Adaptor) Output power 28.65 dBm maximum ERP measured for GSM850 Extreme vol. Limits 3.5VDC to 4.2VDC (nominal: 3.7VDC) …

Text truncated - open the document above for the full version.

Test Setup Photos

RAD131 FCC test setup photo 1. Radiated Spurious Emission 2. Conducted Emission

Contact Information

Applicant

Zhizhou Gong
[email protected]+86(0)2151798260Fax: +86(0)2161460600

Technical Contact

Telecommunications Metrology Center of MIITXue Zhen
[email protected]

100191 No 52, Huayuanbei Road, · Beijing · China

Test Firm

TMC-Telecommunication Metrology Center of M.I.I.TChongwen Song
[email protected]0086-10-62303288Fax: 0086-10-62304793

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
224E1.85 GHz - 1.91 GHz230.00 mW300KGXW0.1 ppm
Confidentiality
Long Term
Grant Notes
Power Output is ERP for Part 22 and EIRP for Part 24. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and which provide at least 1.5 cm separation between the device and the users body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance. The highest reported SAR values are: Part 22: Head: 1.10 W/kg; Body-worn 0.74 W/kg; Part 24: Head: 0.67 W/kg; Body-worn 0.44 W/kg.

Other Applications from TCT Mobile Limited

HSUPA/HSDPA/UMTS tribands / GSM quadbands/LTE 6-band mobile phone - FCC ID RAD558 - TCT Mobile Limited
RAD558

HSUPA/HSDPA/UMTS tribands / GSM quadbands/LTE 6-band mobile phone

Nov 15, 2015

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
CDMA 1X BC0/BC1/BC10 mobile phone - FCC ID RAD556 - TCT Mobile Limited
RAD556

CDMA 1X BC0/BC1/BC10 mobile phone

Sep 08, 2015

Equipment Class

PCE - PCS Licensed Transmitter held to ear
GSM Quadband / UMTS Triband mobile phone - FCC ID RAD552 - TCT Mobile Limited
RAD552

GSM Quadband / UMTS Triband mobile phone

Jun 20, 2015

Equipment Class

PCE - PCS Licensed Transmitter held to ear
HSDPA/HSUPA/HSPA+/UMTS quad band /GSM quad band/LTE 4 band mobile phone - FCC ID RAD550 - TCT Mobile Limited
RAD550

HSDPA/HSUPA/HSPA+/UMTS quad band /GSM quad band/LTE 4 band mobile phone

Jun 06, 2015

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
WCDMA tri band / GSM quad band Moblie phone with BT, Wi-Fi functionality. - FCC ID RAD549 - TCT Mobile Limited
RAD549

WCDMA tri band / GSM quad band Moblie phone with BT, Wi-Fi functionality.

May 13, 2015

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter